HomeMy WebLinkAboutSullivan Shingle PA.pdfMIAMI-DARE COUNTY
M�IAM1•QADE PRODUCT CONTROL SECTION
15:1�Y 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eovleconomy
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD', Timberline® Natural Shadow', Timberline' NS, Timberline® American
Harvest®, Timberline® All, Timberline HDZ®, Timberline® CS and Fortitude® Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA,
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA #19-0312.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
-- /
NOA Na.: 21-1209.01
Miar�i•naoecouNTr Expiration Date: 02/21/27
Approval Date: 01/06/22
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Cate¢orv:
Roofing
Sub-Cateeory:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE
This approves GAF Timberline HD®, Timberline' Natural Shadow', Timberline' NS, Timberline American'
Harvest', Timberline' AH, Timberline HDZ®, Timberline' CS and Fortitude' Shingles as manufactured by GAF
as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
GAF Timberline HD'
13 '/a " x 39 3/s "
TAS 110
Fiberglass reinforced heavy weight asphalt roof
Manufacturing
shingle, with a laminate profile
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline' Natural
13 '/4" x 39 3/8.
TAS 110
Fiberglass reinforced heavy weight asphalt roof
Shadow' and Timberline' NS
shingle, with a laminate profile
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAR Timberline American
13 '/4 " x 39 3/8"
TAS 110
Fiberglass reinforced heavy weight asphalt roof
Harvesf'
shingle, with a laminate profile
Manufacturing
Locations #2, 4 , 6
GAF Timberline'AH
13 '/4"x 39 3/8"
TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing
shingle, with a laminate profile
Locations #2, 4, 6, 9
GAF Timberline HDZ'
13 '/4" x 39 3/8"
TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing
shingle, with a laminate profile
Locations #1, 2, 3, 4, 5, 6, 7, 8, 9,
10
GAF Fortitude'
13 '/4, x 39 3/8 "
TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing
shingle, with a laminate profile
Location #4
GAF Timberline' CS
13 1/4"x 39 3/s"
TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing
shingle, with a laminate profile
Location #9
NOA No.: 21-1209.01
Expiration Date: 02/21/27
Approval Date: O1/06/22
Page 2 of 6
MANUFACTURING LOCATION
1.
Tampa, FL
2.
Michigan City, IN
3.
Baltimore, MD
4.
Myerstown, PA
5.
Ennis, TX
6.
Tuscaloosa, AL
7.
Dallas, TX
8.
Shafter, CA
9.
Fontana, CA
10.
Minneapolis, MN
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, LLC
ASTM D3462
4788932264
12/13/19
ASTM D3462
4788717529
01/31/19
ASTM D3462
4787344101
07/25/16
TAS 107
4789225984
11/1/19
TAS 107
4788717529
01/31/19
TAS 107
01NK45803
04/13/94
TAS 107
06NK05159
08/09/06
TAS 107
04NK04273
02/20/04
TAS 107
05CA42840
11/11/05
TAS 107
02NK41811
11/11/02
TAS 107
03CA35209
10/17/03
TAS t07
04CA13850
08/30/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-912-02-01
12/17/18
TAS 100
GAF-044-02-01
01/13/04
TAS 100
GAF-098-02-01
11/08/05
TAS 100
GAF-101-02-01
11/09/05
TAS 100
GAF-116-02-02
03/23/06
TAS-100
ELK-083-02-01
10/16/02
ELK-084-02-01
10/15/02
ELK-085-02-01
10/ 14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
10/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
NOA No.: 21-1209.01
MIAMI•DADE COUNTY Expiration Date: 02/21/27
Approval Date: 01/06/22
Page 3 of 6
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing
facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below.
GgNlPAFPKR0MVE9D
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate
the installation of this system.
NOA No.: 21-1209.01
Expiration Date: 02/21/27
Approval Date: 01/06/22
Page 4 of 6
DETAIL A
COURSE LAYOUT
Exposure
NOA No.: 21-1209.01
Expiration Date: 02/21/27
Approval Date: 01/06/22
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
FOR GAF TIMBERLINE HD® TIMBERLINE® NATURAL SHADOW® AND TIMBERLINE® NS
39-3/8"
(Im)
— 14-112" - 17-112"
(3- A-05mm
6-112" - 9-1/2"
(166- 241-1
14-1 /2" -17-1 /2" —
�(368 -1 /2
6-112" - 9-1/2"
(1&5. 241mm�
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
Nail guide line
5-314" - 6-1 /4"
(146mm - 159mm)
from bottom of shingle
Self seal
adhesive
on back
OVERALL DL ENSIONS AND NAILING PATTERN
FOR TIMBERLINE HDrj TIMBERLINE® CS, TIMBERLINE®AH, AND FORTITUDE®
13-1/4"
(337 mm)
5-13��1�-8-114'
(148 mrn -159 mm)
For Man&ud Roofs
39-3/8" (1 m)
6-11?-9-tT(165rnm-241 r
XP-2-112' (13 man - 64 mm)
END OF THIS ACCEPTANCE
l-9-lrCtlbtbMM-Z41 mm
lj2' - 2-1a2' (13 mm - 64 mm;
— TARGET
MAIL ZONE
5-13/16" - 7-518"
(148 mm -194 mm)
NOA No.: 21-1209.01
Expiration Date: 02121/27
Approval Date: 01/06/22
Page 6 of 6