Certification for Design Load Compliance
Project Name: M o rr r n t e-s c) c1 c-9-
Project Address: 1-04- 6 N�fiSI<s 1s1�..�
Permit #:
Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
* This certification must be completed, signed, and sealed by the design professional of record.
* Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1.
2.
3.
4.
5.
DESIGN CODE: Florida $• - Wn: Code 2010 Edition with 20 r Supplements using ASCE 7-10
Structure Designed as (check one): Z Enclosed _Partially Enclosed Open
Risk Category: _I II III IV
Design Wind Velocity 16b mph _
Mean Roof Height 15 ft
Exposure Category: B C ✓ D
ASD LRFD End Zone Width: 3, 9 ft
Roof Pitch: (o :12 Parapet:
_ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: q2.o Zone 2: 73.1 Zone 3:103. 1 Zone 4: N 9. 8` Zone 5: G1. Garage: ` & J
7. Design Loads: Floor: dos PSF Roof/Dead: 2-5 PSF Roof/Live: 30 Balcony: &0 PSF
Dock: -- PSF Deck: bO PSF Stairs: q o PSF Fence: " PSF Railings: PSF
8. Were Shear Walls Considered For Structure? ')( Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? )( Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: Soo PSF Soil Test Reports Submitted? < _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
Signature, Date, and Seal
SLCCDV Form # 020-12 Revised 3/15/12 (JS)
& l SSs
Print Name Cert # & Co. Cert Auth.