Loading...
HomeMy WebLinkAboutCertification For Design Load Compliancea+ Planning &Development Services Department a Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: M oar cn Project Address: Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida LL, Code 2010 Edition with 20 — Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: _I II _III IV Exposure Category: B C ✓ D 4. Design Wind Velocity 165 mph _ASD ✓ LRFD End Zone Width: 5.9 ft 5. Mean Roof Height 15 ft Roof Pitch: (o :12 ' Parapet: _XA___ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone l: 2- o Zone 2: 73.1 Zone,3:108. 1 Zone 4: tj 9 • T Zone 5: &1, Garages 7. Design Loads: Floor: &5 PSF Roof/Dead: 2- 5' PSF Roof/Live: 30 Balcony: &D PSF Dock: -- PSF Deck: 1O PSF Stairs: q o PSF Fence: PSF Railings: — PSF 8. Were Shear Walls Considered For Structure? 'X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: Soo PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide, adequate resistance to -the design fnrreS snecified: Signature, Date, and Seal SLCCDV Form # 020-12 Revised 3/15/12 (JS) Print Name Cert # & Co. Cert Auth. �il�q�} trt �nC.`1tG�in� Arjoc_ Soo Ave, oC Ck, ,f.o..S, S!•c. zGo V"q I 11 «( r— 3 31( t Company Name & Address FILE 6�