HomeMy WebLinkAboutEnergy Efficiency Codei
r
FORM 405-10
�FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Morren Residence
Builder Name:
Street: Lot 868 Nettles Island
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL ,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1205.6 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1064.80 ft2
b. Frame - Wood, Exterior
R=13.0 140.80 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
k�. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1028.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1028.00 ft2
6• Conditioned floor area above grade (W) 1028
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(132.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 205.6
a. U-Factor. Sgl, U=0.29 132.25 ft2
SHGC: SHGC=0.30
b. U-Factor: NIA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
30.0 SEERA5.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
30.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1028.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1028.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.129 Total Proposed Modified Loads: 20.48
PASS
Total Standard Refer nce Loads: 27.48
I hereby certify that the plans and sp ificati0 s cov by
Review of the plans and
4Z ST.gT
this calculation are in compliance with the Florida E ergy
specifications covered by this
Code.
calculation indicates compliancert+C
",,.Af� cs
PREPARED BY: /� '"'��"'
with the Florida Energy Code.
Before construction is completed
rn„r% ;;•-;;•, �� O
�-
DATE: 5 71
this building will be inspected for
compliance with Section 553.908
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
COD
with the Florida Energy Code.
WE'1¢�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: s
DATE:
.F
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
5/13/20151:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software RECOP ell Yf
r
_- ENERGY
PERFORMANCE LEVEL
(EPL)
'
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 75
The lower the EnergyPerformance Index, the more efficient the home.
Lot 868 Nettles Island, Fort Pierce, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=5.0
1064.80 ft2
b. Frame - Wood, Exterior
R=13.0
140.80 ft2
. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
2 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5.. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
1028.00 ft2
6. Conditioned floor area (ft2)
1028 b. N/A
R=
ft2
7. Windows" Description
Area c. N/A
R=
ft2Z
a. U-Factor: Sgl, U=0.29
132.25 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R ft
6 205.6
SHGC: SHGC=0.30
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor. N/A
ft2 a. Central Unit
30.0 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
30.0
HSPF:9.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.300
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Electric
a. Slab -On -Grade Edge Insulation R=0.0 1028.00 ft2EF:
0.99
b. WA R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:/ -� ry,a ,,, _� �Date:
Address of New Home: A.,- sa n -4 L v a_
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
F9L�I� � CT
'
PROJECT
Title:
Morren Residence
Bedrooms: 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 1028
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units:
1
Worst Case: No
0
PlatBook:
Street: Lot 868 Nettles Island
Builder Name:
Permit Office:
St. Lucie County
Rotate Angle:
Cross Ventilation:
County: Sarasota
Jurisdiction:
Whole House Fan:
City, State, Zip: Fort Pierce ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design
Temp Heating Design Daily Temp
' Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1028 9046.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1028 9046.4 Yes 1
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 130 ft 0
1028 ft2
0 0 1
ROOF
Roof Gable Roof
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
#
Type
Materials Area Area Color
1
Hip
Metal 1114 f12 0 ft2 White
0.96
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1028 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 1028 ft2
0.11 Wood
5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software FILE ag
I
N
Exterior
Concrete Block - I
2
S
Exterior
Concrete Block - I
3
E
Exterior
Concrete Block - I
4
W
Exterior
Concrete Block - I
5
N
Exterior
Frame - Wood
6
E
Exterior
Frame - Wood
I1/ # Omt Door Type
1 W Wood
WALLS
Space
Cavity Width
R_value Ft In
Height
Ft In
Wall
J #
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Area
1
N
1
Metal
Single (Tinted)
Yes
0.29
0.3
12.0 ft2
2
N
1
Metal
Single (Tinted)
Yes
0.29
0.3
15.0 ft2
3
N
1
Metal
Single (Tinted)
Yes
0.29
0.3
4.0 ft2
4
S
2
Metal
Single (Tinted)
Yes
0.29
0.3
30.0 ft2
5
E
3
Metal
Single (Tinted)
Yes
0.29
0.3
15.0 ft2
6
E
3
Metal
Single (Tinted)
Yes
0.29
0.3
11.3 ft2
7
W
4
Metal
Single (Tinted)
Yes
0.29
0.3
45.0 ft2
I # Scope Method
1 Wholehouse Best Guess
INFILTRATION
SLA CFM 50 ELA EgLA
.0005 1348.2 74.02 139.2
HEATING SYSTEM
Area
Sheathing Framing
R-Value Eraction--Abso"rafle%
Solar
Below
299.2 ft2
0
0.75
0
176.0 ft2
0
0.75
0
299.2 ft2
0
0.75
0
290.4 ft2
0
0.75
0
88.0 ft2
0.23
0.75
0
52.8 ft2
0.23
0.75
0
Width Height Area
Ft In Ft In
3 7 21ft2
Overhang
Depth Separation Int Shade Screeni
1 ft 0 in 0 ft 0 in Drapes/blinds None
1 ft 0 in 0 ft 0 in Drapes/blinds None
1 ft 0 in Oft 0 in Drapes/blinds None
1 ft 0 in Oft 0 in Drapes/blinds None
1 ft 0 in Oft 0 in Drapes/blinds None
1 ft 0 in Oft 0 in Drapes/blinds None
1 ft 0 in Oft 0 in Drapes/blinds None
ACH ACH 50
.365 8.9421
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
None
HSPF: 9
30 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR
Block
Ducts
1
Central Unit
None
SEER: 15
30 kBtu/hr 900 cfm 0.75
1
sys#1
5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
FILE COPY
Page 3 of 5
.a
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Exterior
0.99 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
I �/ #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 205.6 ft
Attic
51.4 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
ng Jan
Feb
f X�MOct
ar
Apr
Apr
M l
May Jun n Ju
Aug
rj
Sep
[Heat
La
Oct
H Nov
Nov
H Dec
DecVenting
Jan
Feb
[X Mar
Jun Jul
Aug
Sep
lx�
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
5/13/20151:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 868 Nettles Island PERMIT #:
Fort Pierce, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
FE E-1 COPY
5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5