Loading...
HomeMy WebLinkAboutEnergy Efficiency Codei r FORM 405-10 �FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Morren Residence Builder Name: Street: Lot 868 Nettles Island Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1205.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1064.80 ft2 b. Frame - Wood, Exterior R=13.0 140.80 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 k�. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1028.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1028.00 ft2 6• Conditioned floor area above grade (W) 1028 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(132.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 205.6 a. U-Factor. Sgl, U=0.29 132.25 ft2 SHGC: SHGC=0.30 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEERA5.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 30.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1028.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1028.00 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.129 Total Proposed Modified Loads: 20.48 PASS Total Standard Refer nce Loads: 27.48 I hereby certify that the plans and sp ificati0 s cov by Review of the plans and 4Z ST.gT this calculation are in compliance with the Florida E ergy specifications covered by this Code. calculation indicates compliancert+C ",,.Af� cs PREPARED BY: /� '"'��"' with the Florida Energy Code. Before construction is completed rn„r% ;;•-;;•, �� O �- DATE: 5 71 this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� COD with the Florida Energy Code. WE'1¢� OWNER/AGENT: BUILDING OFFICIAL: DATE: s DATE: .F - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 5/13/20151:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software RECOP ell Yf r _- ENERGY PERFORMANCE LEVEL (EPL) ' DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 75 The lower the EnergyPerformance Index, the more efficient the home. Lot 868 Nettles Island, Fort Pierce, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1064.80 ft2 b. Frame - Wood, Exterior R=13.0 140.80 ft2 . Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area 5.. Is this a worst case? No a. Under Attic (Vented) R=30.0 1028.00 ft2 6. Conditioned floor area (ft2) 1028 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2Z a. U-Factor: Sgl, U=0.29 132.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft 6 205.6 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit 30.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 30.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Electric a. Slab -On -Grade Edge Insulation R=0.0 1028.00 ft2EF: 0.99 b. WA R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:/ -� ry,a ,,, _� �Date: Address of New Home: A.,- sa n -4 L v a_ City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software F9L�I� � CT ' PROJECT Title: Morren Residence Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1028 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No 0 PlatBook: Street: Lot 868 Nettles Island Builder Name: Permit Office: St. Lucie County Rotate Angle: Cross Ventilation: County: Sarasota Jurisdiction: Whole House Fan: City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp ' Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1028 9046.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1028 9046.4 Yes 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 130 ft 0 1028 ft2 0 0 1 ROOF Roof Gable Roof Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) # Type Materials Area Area Color 1 Hip Metal 1114 f12 0 ft2 White 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1028 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1028 ft2 0.11 Wood 5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software FILE ag I N Exterior Concrete Block - I 2 S Exterior Concrete Block - I 3 E Exterior Concrete Block - I 4 W Exterior Concrete Block - I 5 N Exterior Frame - Wood 6 E Exterior Frame - Wood I1/ # Omt Door Type 1 W Wood WALLS Space Cavity Width R_value Ft In Height Ft In Wall J # Ornt ID Frame Panes NFRC U-Factor SHGC Area 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 12.0 ft2 2 N 1 Metal Single (Tinted) Yes 0.29 0.3 15.0 ft2 3 N 1 Metal Single (Tinted) Yes 0.29 0.3 4.0 ft2 4 S 2 Metal Single (Tinted) Yes 0.29 0.3 30.0 ft2 5 E 3 Metal Single (Tinted) Yes 0.29 0.3 15.0 ft2 6 E 3 Metal Single (Tinted) Yes 0.29 0.3 11.3 ft2 7 W 4 Metal Single (Tinted) Yes 0.29 0.3 45.0 ft2 I # Scope Method 1 Wholehouse Best Guess INFILTRATION SLA CFM 50 ELA EgLA .0005 1348.2 74.02 139.2 HEATING SYSTEM Area Sheathing Framing R-Value Eraction--Abso"rafle% Solar Below 299.2 ft2 0 0.75 0 176.0 ft2 0 0.75 0 299.2 ft2 0 0.75 0 290.4 ft2 0 0.75 0 88.0 ft2 0.23 0.75 0 52.8 ft2 0.23 0.75 0 Width Height Area Ft In Ft In 3 7 21ft2 Overhang Depth Separation Int Shade Screeni 1 ft 0 in 0 ft 0 in Drapes/blinds None 1 ft 0 in 0 ft 0 in Drapes/blinds None 1 ft 0 in Oft 0 in Drapes/blinds None 1 ft 0 in Oft 0 in Drapes/blinds None 1 ft 0 in Oft 0 in Drapes/blinds None 1 ft 0 in Oft 0 in Drapes/blinds None 1 ft 0 in Oft 0 in Drapes/blinds None ACH ACH 50 .365 8.9421 # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 9 30 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 30 kBtu/hr 900 cfm 0.75 1 sys#1 5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software FILE COPY Page 3 of 5 .a HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.99 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # I �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 205.6 ft Attic 51.4 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: ng Jan Feb f X�MOct ar Apr Apr M l May Jun n Ju Aug rj Sep [Heat La Oct H Nov Nov H Dec DecVenting Jan Feb [X Mar Jun Jul Aug Sep lx� Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/13/20151:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 868 Nettles Island PERMIT #: Fort Pierce, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. FE E-1 COPY 5/13/2015 1:27 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5