HomeMy WebLinkAboutHVAC Loads.r Morren Residence HVAC Load Calculations for Morrren Lot 868 Nettles Island Fort Pierce, Florida -`•41fF �. - ii Prepared By: Residential Energy Calc's Wednesday, May 13, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. FILEUMPY Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac Resi' ential & LightCommerclal HVAGLoads Elite Software Development; Inc. Residential Energy Calc's Mor[en Residence .Port Saint Lucie, FL 34983 = . „ :. Page 2, Pro ect Report LGeneralP_ro ect.lnformafion Project Title: Morren Residence Designed By: QEA Associates Project Date: Wednesday, May 13, 2015 Client Name: Morrren Client Address: Lot 868 Nettles Island Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's Desi n D,ata , MW Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer. 90 78 59% 50% 75 61 Check�Fi Oiles Total Building Supply CFM: 920 CFM Per Square ft.: 0.894 Square ft. of Room Area: 1,028 Square ft. Per Ton: 444 Volume (ft) of Cond. Space: 9,740 Bwldin jLoads�,' Total Heating Required Including Ventilation Air: 21,467 Btuh 21.467 MBH Total Sensible Gain: 20,955 Btuh 75 % Total Latent Gain: 6,820 Btuh 25 % Total Cooling Required Including Ventilation Air: 27,775 Btuh 2.31 Tons (Based On Sensible + Latent) Notes r ;.NUNN Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. FILE copy- C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM . P. Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, lnc: Residential Energy Calei ., Morren Residence, Port Saint Lucie, FL 34983 Pa a 3' Miscellaneous Report, System 1 Rfjeem Or Equivalent Outdoor Outdoors Outtloor ��Indoor* ndoorR zGrams "ut In Data s ° ;D ;Bulb ". * UVetBulbg Rel` Hum �'RelHum,u D Bulb,t giffetcnce •:i , .; : .., , Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 Duct Sizin huts Main Trunk Runouts Calculate: Yes Yes Use.Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. outside:Air:Data sa 4 Winter Summer Infiltration Specified: 0.450 AC/hr 0.230 AC/hr 73 CFM 37 CFM Infiltration Actual: 0.354 AC/hr 0.000 AC/hr Above Grade Volume: X 9,740 Cu.ft. X 9,740 Cu.ft. 3,453 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 58 CFM 0 CFM Total Building Ventilation: 45 CFM 45 CFM ---System 1-- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.450 AC/hr (73 CFM), Construction: Average Summer Infiltration Specified: 0.230 AC/hr (37 CFM), Construction: Average D,ucf Load.;Factor';Scenariosfor.�S' stem 1, � � .:; J " ` ` y �; Attic : f f �ut{{.:" r Duct#k:; Surfaces r Fromt No: "; T e. : Descn tiony> Loeation ry ` Ceil�n "� ` Area Leaka e, .Insulations >, . u ..[T MDD 1 Supply Attic 16B 0.12 6 278 No 1 Return Attic 16B 0.12 6 103 No copy C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac,,;Resi",enttaf&�Light�Commerc�al+H17AC Loads��� ;��� MorrenResidence�: PortaSa�nt?Lucie'Fl...ri,34983-��Fa��. �,,, r���� ,���;.,,_ ��rewrs �������� �. ��<.::,.. �.�._'��dn��.s.4;�����._:.�-.'��.•�'��.,;, ��,��,r. �,_,.+ .�,.Pa e:,,4� port Load Preview Report- - Net ft z Sen LaY Net Sen Htg Clg Act Duct Scope Ton lion Area Gain Gain Gain Loss CFM CFM CFM Size Building 2.31 ; 444' 1,028 � 20,955 : 6,820' 27,775 21,467 •. 261' 920; 920' System 1 2.31( 444 , 1 028 ` 20,955 � 6 820 ! 27,775 21,467 261 !NMI 920 _ ! 10x17 Ventilation 742 1,868 ' 2,6101 1,385 ; Duct Latent ' 1,252 1252 Zone 1 � 1,028 20 213 : 3,700. 23,913 20,0821 261 NMI 920 ' 10x17 1-Living 279�_ 37241 0^-_ 3,724 5,689 74! 169 2-5 2-Master Bedroom � 169 . 3 014 ; 700 " 3,714 ' 2,1031 27 _ 137 2-5 3-Master Bath � 64 • 1,401 ; 600 ' 2,001 , 1,787T 23 64 1-5 4-Walk In Closet � 39, 294 ! 0 2941 1 241 , 16! 13 1-4 - 5-Bath 2 60 4601 0 460 ! 918 12 i 21 4 - J 1-121 6-Bedroom 2 _ _ _ 1,9411 251 109 1-6 7-IGtchen 121�- 4520' 1000". 5520! 3352� 44 206 ..2-6 8-Dining 175 4,406 Ss! Ss Ss Load FILE copy : 400' 4,806, C:\ ...1Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Res!• antral 8< Lrght Commercial HVACL 'd r5{ ' Elite Software Development, Residentral Energy Caic's f ` x " �� �r{ `'q `�}'; MorrenResidence Port.Sairit Lucie, FL- 34983 .. Y a e Duct Size Preview Room or Source Minimum Maximum Rough. Design SP Duct Duct Htg Clg I Act. Duct Duct Name Velocity Velocity Factor U100 Loss Velocity Length Flow Flow Flow Size System 1 Supply Runouts - ------ ---- ----- ----------- ---- - - - - -- -- - -- -- — --------- - Zone 1 1-Living _ Built -In 450 750 001 0.1 621.3 74 169 2-5 2-Master room Built -In 137 2-5 - 3-Master Bath Built. -In 450 750' 0 01 _ 0.1 �iT- 467 5 !1-5` 23: 64i 1 _. 4-Walk In Closet Built -In - 450 f T 750 0.01_ �- 0.1 -- y 153 16 13' 1-4 5-Bath 2 _------T- —� Built-in _ 450 750 0.01 01 I 239.91 -- 12;® 21 1-4 6-Bedroom 2 Built-in 450 750 001 " 01 ; 554.9 25 109 1-6 7-Kitchen Built -In 450 750{ 001 0.11 523.7 44', 206 2-6 8-Dining _. --- Built-in 450 _- 750 001 ...._ 01 510 5 - - 40I� 200 2-fi - .. Other Ducts in System 7 r. -- - ..... - Supply Main Trunk ; Built -In 650 900' 0.003 0.1 779 261 920 10x17 Summary System 1 - Heating Flow: 261 _..._ .._. .- -- ........_ .. .._ . _ ,_. _... _ _-....._.. _. Cooling Flow: 920 FILE COP C:1... Worren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Ahvac Residential & Light Commercial HVAC Loads Elite9oftwrare Development, Inc. ` dential ResiEnergy Calc's Morren Residence Port 8aint Lucie, FL 34983 Page 6 Total Building Summa Loads �C�,�ompone'nf " ` ' " `" -Area Sen La"t Sen Tofal ®escn _tion Quart .Loss.. Gain _ _Gain.'. IA-cb-o: Glazing -Single pane, operable window, clear, 117 3,540 0 _Gain 6,564 6,564 metal frame with break, u-value 1.08, SHGC 0.75 IA-cm-o: Glazing -Single pane, operable window, clear, 15.2 541 0 1,165 1,165 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 21 229 0 213 213 13A-5ocs: Wall -Block, board insulation only, R-5 board 938.8 3,287 0 1,796 1,796 insulation, open core, siding finish 12C-Osw: Part -Frame, R-13 insulation in 2 x 4 stud 127.6 174 0 174 174 cavity, no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1028.4 922 0 1,316 1,316 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 130 4,942 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 13,635 0 11,228 11,228 People: 8 1,600 1,840 3,440 Equipment: 2,100 2,700 4,800 Lighting: 0 0 0 Ductwork: 4,677 1,252 3,817 5,069 Infiltration: Winter CFM: 58, Summer CFM: 0 1,770 0 0 0 Ventilation: Winter CFM: 45, Summer CFM: 45 1,385 1,868 742 2,610 AED Excursion: 0 0 628 628 Total Building Load Totals: 21,467 6,820 20,955 27,775 Total Building Supply CFM: 920 CFM Per Square ft.: 0.894 Square ft. of Room Area: 1,028 Square ft. Per Ton: 444 Volume (ft3) of Cond. Space: 9,740 rP'.i4 r`14?� .' . &•.x "1"�, 54 $'aN''! �` . ,L.'i'f '' �r rw,� "�. '�c. Total Heating Required Including Ventilation Air: 21,467 Btuh 21.467 MBH Total Sensible Gain: 20,955 Btuh 75 % Total Latent Gain: 6,820 Btuh 25 % Total Cooling Required Including Ventilation Air: 27,775 Btuh 2.31 Tons (Based On Sensible + Latent) " Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. FILE copy C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM R vac 'asential &Light Commercial HVAC Loads Elite Software Development ,lnc. MorremResPa nce PorESainial t Lucer9FL 34983 Y :, e 8 . Detailed Room Loads.- Roomm 1 - Living (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 15.5 ft. Zone Number: 1 Area: 279.0 sq.ft. Supply Air: 169 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.6 AC/hr Volume: 2,790.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 13 CFM Runout Air: 85 CFM Percent of Supply.: 8 % Runout Duct Size: 5 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 621 ft./min. Percent of Supply: 5 % Runout Air Velocity: 621 ft./min. Actual Winter Infil.: 16 CFM Actual Loss: 0.317 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -lJ- Htg Sen Clg L at Sen D,escri _,tion Quantit Value HTM Loss HTtM _Gain_. Gain S -Wall-13A-5ocs 18 X 10 150 0.125 3.5 525 1.9 0 287 E -Wall-13A-5ocs 15.5 X 10 143.8 0.125 3.5 503 1.9 0 275 S -GIs-1A-cb-o shgc-0.75 100%S 30 1.080 30.2 908 32.0 0 960 (2) E -GIs-1A-cm-o shgc-0.75 0%S (3) 11.2 1.270 35.6 399 91.2 0 1,026 UP-Ceil-1 6C-30 18 X 15.5 279 0.032 0.9 250 1.3 0 357 Floor-22A-ph 34 ft.. Per. 34 1.358 38.0 1,293 0.0 0 0 Subtotals for Structure: 3,878 0 2,905 Infil.: Win.: 15.8, Sum.: 0.0 335 1.451 486 0.000 0 0 Ductwork: 1,325 703 AED Excursion:_ 116 Room Totals: _ _ _ _. 5,689 0 3,724 FILE�� C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Residential & Light Commercial HVAC Loads 'Elite,SoftWare Development, Inc. Residential :Energy Calds Morren.Residence- Port Saint Lucie, FL34983 :. Ra e 9 , Detailed: Room.,Loads =Room` 2 -, Master Bedroom (Avera a Load Procedure)., tGeneral . Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. ' , System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 169.0 sq.ft. Supply Air: 137 CFM Ceiling Height: 8.8 ft. Supply Air Changes: 5.5 AC/hr Volume: 1,487.2 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 5 CFM Runout Air: 69 CFM Percent of Supply.: 3 % Runout Duct Size: 5 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 503 ft./min. Percent of Supply: 5 % Runout Air Velocity:. 503 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.209 in.wg./100 ft. Actual Summer Infil.: 0 CFM Iten : Area -U- Htg Sen Clg Lat Sen �Descri tion . Q_ uantit Valve H�TM Loss HTM Gain G_ ain E -Wall-13A-5ocs 13 X 8.8 99.4 0.125 3.5 348 1.9 0 190 E -GIs-1A-cb-o shgc-0.7516%S 15 1.080 30.2 454 79.0 0 1,185 UP-Ceil-16C-3013 X 13 169 0.032 0.9 151 1.3 0 216 Floor-22A-ph 13 ft..Per. 13 1.358 38.0 494 0.0 0 0 Subtotals for Structure: 1,447 0 1,591 Infil.: Win.: 5.4, Sum.: 0.0 114 1.451 166 0.000 0 0 Ductwork: 490 569 AED Excursion: 94 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: _ _ _ T_ 300 300 Room Totals: 2,103 700 3,014 FILL COF Y C:1... Worren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Residential Light Commercial HVAC Loads Residential Energy_. ales �� Elite;Software Development, Inc. Morren Resitlence Port Saint Lucie, FL 34983 Page e10 -Detailed Room Loads .- Room 3 - Master Bath (Average Load Procedure) ,General _ Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 64 CFM Ceiling Height: 8.8 ft. Supply Air Changes: 6.8 AC/hr Volume: 563.2 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 64 CFM Percent of Supply.: 6 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 468 ft./min. Percent of Supply: 5 % Runout Air Velocity: 468 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.181 in.wg./100 ft. Actual Summer Infil.: 0 CFM JillItem Area -U- Htg Sen Clg Lat Sen JIM Description Quanti Value HTyM Loss HTM Gain Gain . N -Wall-13A-5ocs 8 X 8.8 64.4 0.125 3.5 225 1.9 0 123 E -Part-15'/15°-12C-Osw 8 X 8.8 70.4 0.091 1.4 96 1.4 0 96 N -GIs-1A-cb-o shgc-0.75 100%S 6 1.080 30.2 181 32.0 0 192 UP-Ceil-16C-30 8 X 8 64 0.032 0.9 57 1.3 0 82 Floor-22A-ph 16 ft..Per. 16 1.358 38.0 608 0.0 00 _ _ Subtotals for Structure: _ 1,167 _ 0 493 Infil.: Win.: 6.6, Sum.: 0.0 141 1.449 204 0.000 0 0 Ductwork: 416 265 AED Excursion: 44 Equipment: 600 600 Room Totals: 1,787 600 1,401 FILE ':'Orq C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM & Light Commercial HVAC Loads, Elite -Software DeVelopment, Inc. j�;RWhe'-Residential Residential Energy,daids ' j Morren Residence :Port Saint,Lude, FL 34983 Detailed,Room Loads - Room 4 - Walk In Closet (Avers a -Load Procedure) - General° Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 6.5 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 39.0 sq.ft. Supply Air: 13 CFM Ceiling Height: 8.8 ft. Supply Air Changes: 2.3 AC/hr Volume: 343.2 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 13 CFM Percent of Supply.: 21 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 153 ft./min. Percent of Supply: 5 % Runout Air Velocity: 153 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.028 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item`. Area -ll- ` Htg Sen Clg Lat Sen ;Des'I tion Quanti Value HTM Loss Hl'M Gain Gain E -Wall-13A-5ocs 6 X 8.8 52.8 0.125 3.5 185 1.9 0 101 N -Part-15°/15°-12C-Osw 6.5 X 8.8 57.2 0.091 1.4 78 1.4 0 78 UP-Ceil-16C-30 6.5 X 6 39 0.032 0.9 35 1.3 0 50 Floor-22A-ph 13 ft.. Per. 13 1.358 38.0 494 0.0 0 0 Subtotals for Structure: 792 0 229 Infil.: Win.: 5.2, Sum.: 0.0 110 1.455 160 0.000 0 0 Ductwork: 289 55 AED Excursion: 9 Room Totals: 1,241 0 294 F:LE C 0 F" C:\ ...1Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM F Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: munout Duct size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 5 Bafh 2 (AVer` 'e Loads• Room d . .?,r• x �occurrences: f Htg. & cig_ Systerrr Numbery° 10.0 Ift. 6.0"'ft. done Number: 60.0 sq.ft. Supply Air: 8.8 ft.Supply Air Changes: 528.0 cu.ft. �Req. Vent. Clg: 1 Actual Winter Vent.: 21 CFM Percent of Supply.: 4 in. Actual Summer Vent.: 240 ft./min. Percent of Supply: 240 ft./min. Actual Winter Infil.: 0.067 in.wg./100 ft. Actual Summer Infil.: N-Cls-1A-cb-o shgc-0.75 100% UP-Ceil-16C-30 10 X 6 Floor-22A-ph 6 ft..Per. Subtotals for Structure: Infil.: Win.: 2.5, Sum.: 0.0 Ductwork: A_ED Excursion: Room Totals: 6 1.080 30.2 60 0.032 0.9 6 1.358 38.0 53 1.458 � EIIte.Softwate Development, inc. 2st1"P Morren Residence', LOa PIrocedure) 1 21 CFM 2.4 AC/hr 0 CFM 2 CFM 10 % 1 CFM 5 % 2 CFM 0 CFM IVY 181 32.0 0 192 54 1.3 0 77 228 0.0 0 0 627 0 359 77 0.000 0 0 214 87 14 918 0 460 C:\ ...\Morren Residence.rh9 3,7201-5, '11:41 AM Rhvac Residential & Light Commercial HVAC Loads 4 EliteSoftware Development; Inc. Residential ,Energy Calds Morren Residence' Port Saint Lucie, FL 3083 Pa a 13 Detailed Roomloads.- Room 6`- Bedroom 2 (Av6rage Load Procedure), Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 10.1 ft. Zone Number: 1 Area: 121.2 sq.ft. Supply Air: 109 CFM Ceiling Height: 8.8 ft. Supply Air Changes: 6.1 AC/hr Volume: 1,066.6 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 109 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in.- Actual Summer Vent.: 5 CFM Runout Air Velocity: 555 ft./min. Percent of Supply: 5 % Runout Air Velocity: 555 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: 0.197 in.wg./100 ft. Actual Summer Infil.: 0 CFM �71tem''� Area ` -11- Htg Sen Clg Lat Sen�: Description Quantit : Value . aiTM Loss . HTM Gain ,: Gain N -Wall-13A-5ocs 12 X 8.8 90.6 0.125 3.5 317 1.9 0 173 N -GIs-1A-cb-o shgc-0.75.100%S 15 1.080 30.2 454 32.0 0 480 U P-Ceil-1 6C-30 12 X 10.1 121.2 0.032 0.9 109 1.3 0 155 Floor-22A-ph 12 ft..Per. 12 1.358 38.0 456 0.0 0 0 Subtotals for Structure: 1,336 0 808 Infil.: Win.: 5.0, Sum.: 0.0 106 1.449 153 0.000 0 0 Ductwork: 452 452 AED Excursion: 74 People: 200 lat/per, 230 sen/per: 2 400 460 Equip_ment:_ _ 600 600_ Room Totals: _ _ _ _ 1,941 1,000 2,395 FILE )y C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Residential & Light Commercial HVAC Loads Elite.Software Development, Inc. ResidentraLEnergy Calc's , Morren Residence;. Pori Saint Lucie, FL M98$ Pane 14 Detailed Room Loads-.- Room 7­Kitchen (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 10.1 ft. Zone Number: 1 Area: 121.2 sq.ft. Supply Air: 206 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 10.2 AC/hr Volume: 1,212.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 8 CFM Runout Air: 103 CFM Percent of Supply.: 4 % Runout Duct Size: 6 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 524 ft./min. Percent of Supply: 5 % Runout Air Velocity: 524 ft./min. Actual Winter Infil.: 10 CFM Actual Loss: 0.176 in.wg./100 ft. Actual Summer Infil.: 0 CFM Ite'rn Area -U- Htg Sen CIg Lat Sere• R;escri tion Quantity Value H1TM Loss HTM Gain Gain. N -Wall-13A-5ocs 10.1 X 10 97 0.125 3.5 340 1.9 0 186 W -Wall-13A-5ocs 12 X 10 105 0.125 3.5 368 1.9 0 201 W -GIs-1A-cb-o shgc-0.75 16%S 15 1.080 30.2 454 79.0 0 1,185 N-GIs-IA-cm-o shgc-0.75 100%S 4 1.270 35.6 142 34.8 0 139 UP-Ceil-16C-30 12 X 10.1 121.2 0.032 0.9 109 1.3 0 155 Floor-22A-ph 22 ft..Per. _ 22 1.358 38.0 837 0.0 0 0 Subtotals for Structure: 2,250 0 1,866 Infil.: Win.: 10.4, Sum.: 0.0 221 1.452 321 0.000 0 0 Ductwork: 781 854 AED Excursion: 140 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: _ 600 1,200 Room Totals: 3,352 1,000 4,520 RE COP- C:1... 1Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Residential& Light>Commercial HVAC Loads Residential ;Energy Calc's ", Elite Software Development, Inc. Morien Residence: Port.Samt_ Lucie, 'FL' 34983 ` " , Pade 15 Detailed Room Loads - Room 8 - Dining (Average Load Procedure) ., �Geieral: _ , Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 1 Room. Width: 12.5 ft. Zone Number: 1 Area: 175.0 sq.ft. Supply Air: 200 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.9 AC/hr Volume: 1,750.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 7 CFM Runout Air: 100 CFM Percent of Supply.: 3 % Runout Duct Size: 6 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 510 ft./min. Percent of Supply: 5 % Runout Air Velocity: 510 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.167 in.wg./100 ft. Actual Summer Infil.: 0 CFM Iten " Area -U= Htg Sen Clg Lat Sen �Descrtiption, Quanti _ aloe _ HaTM Loss HTM Gain . .Gain,_ W -Wall-13A-5ocs 14 X 10 89 0.125 3.5 312 1.9 0 170 W-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 W -GIs-1A-cb-o shgc-0.75 16%S (2) 30 1.080 30.2 908 79.0 0 2,370 UP-Ceil-1 6C-30 14 X 12.5 175 0.032 0.9 157 1.3 0 224 Floor-22A-ph 14 ft.. Per. 14 1.358 38.0 532 0.0 _0 0 Subtotals for Structure: 2,138 0 2,977 Infil.: Win.: 6.6, Sum.: 0.0 140 1.450 203 0.000 0 0 Ductwork: 711 832 AED Excursion: 137 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 3,052 400 4,406 FIL"E C0m !. C:\ ...1Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM Rhvac Resi ential &Light Commercial HVAC Loads Elite Software Qevelopment, Inc: Residential Energy,Calc's -` Morren Residence PortSaint Lucie, FL �34983 °' Pa a 16: • System 1 .Room Load Summary T, i 5 kFh�r` „HtgMin Run" k "Run Clgx� Clg �4 Min -Act:: ��s`",Room M� ' , "Area Sens Htg Duct :' Duct Sens Lat Clg' Sys CFM ,f :°... ---Zone 1--- 1 Living 279 5,689 74 2-5 621 3,724 0 169 169 2 Master Bedroom 169 2,103 27 2-5 503 3,014 700 137 137 3 Master Bath 64 1,787 23 1-5 468 1,401 600 64 64 4 Walk In Closet 39 1,241 16 1-4 153 294 0 13 13 5 Bath 2 60 918 12 1-4 240 460 0 21 21 6 Bedroom 2 121 1,941 25 1-6 555 2,395 1,000 109 109 7 Kitchen 121 3,352 44 2-6 524 4,520 1,000 206 206 8 Dining --- 175 3,052 _ 40 _ _ 2-6 510 4,406 _ _ 400 200 200 Ventilation 1,385 742 1,868 Duct Latent 1,252 System 1 total 1,028 21,467 261 20,955 6,820 920 920 System 1 Main Trunk Size: 10x17 in. Velocity: 779 ft./min Loss per 100 ft.: 0.101 in.wg ,_.. ._.. .� .. ..... .. J e t fin: F.:,,ka { !':,m�i flk`°t�. ..mi. Fk, 4 Y ,. ., .. �'�"��>ae.15 .iE �` boni. . '�.. A::��'i<F•in:�.ie�;�`�`,HG7nYGa�4. �..�,.a.. .� 'eh, .: ...;:. Sensiblel ' Conlin %NOW ate}nt S lit b y' .. ., xBtuh .....- . . ,Btuh Net Required: 2.3.1 75% / 25% 20,955 6,820 27,775 Actual: 2.50 73% / 27% 21,900 8,100 30,000 i his` lad t k aFa 5 "n it f Jkz t A Heating System Cooling System Type: Two Speed Heat Pump Standard Air Conditioner Model: RXBH17A07J RPQL030JEZ Indoor Model: RHLLHM3617JA Brand: PRESTIGE SERIES PRESTIGE SERIES Description: HEAT PUMP HSPF 9.0 15 SEER Efficiency: Hi: 9 / Lo: 0 HSPF 15 SEER Sound: 0 0 Capacity: 30,000 Btuh 30,000 Btuh Sensible Capacity: n/a 21,900 Btuh Latent Capacity: n/a 8,100 Btuh FILE COPY C:\ ...\Morren Residence.rh9 Wednesday, May 13, 2015, 11:41 AM