HomeMy WebLinkAboutAPPROVED Polystick IR-XE FL#5259.1 (4.9)9/16/21, 8:10 AM
Florida Building Code Online
ink--.�►.,; lii ,. ;
- `—. L..�_.Ya. .`__mow . __ — ♦ — •..fir.
r 1
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Florida
,::� Product Approval
t �� USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL5259-R33
Revision
2020
Approved
POLYGLASS USA
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Maury Alpert
malpert@polyglass.com
-Po Iv/I�Ck I �-XEFL i. I ( q, q�
TECH REP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
QA REP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass, com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R33 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
4+1
9/16/21, 8:10 AM Florida Building Code Online
FM 4474 2011
FRSA/TRI, Sixth Edition 2018
TAS 103 2020
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
i
Method 1 Option D
04/07/2021
04/12/2021
04/14/2021
06/08/2021
L #
Model, Number or Name
Description
5259.1
Polyglass Roof Underlayments
Polyglass roof underlayments for use in FBC HVHZ jurisdictions.
(HVHZ)
s of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (HVHZ)_pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (HVHZ)_pdf
Created by Independent Third Party: Yes
5259.2
Polyglass Roof Underlayments
Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (NON-HVHZ)_pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular underlayment system for
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
E.33 (NON-HVHZ)_pdf
use in tile roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
Created by Independent Third Party: Yes
pressures. 2.) Refer to ER Section 5 for other limits
of use.
0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487. 1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
ns{' IFIV, Check a
Credit Card
Safe
6{{....-//n...:,4. 1ua:,,......./.../... ...... A*] iri noa:.7..vsu 10/ nano/ a.ao/ oa 1
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
to Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
4LUATICIN RFPAF
Polyglass USA, Inc. Evaluation Report 3m-PLYG-20-FBCER.A-R1
1111 West Newport Center Drive FL5259-R33 (HVHZ)
Deerfield Beach, FL 33442 Date of Issuance: 12/21/2020
(954) 233-1330 Revision 1: 04/07/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments, for use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
or
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen, P.E.
on 04/07/2021. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
©2019 NEMO ETC, LLC
NNEMO I etc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the
7th Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to
the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property Standard Year
RAS 115, TAS 110
Material standard ASTM D226 2009
TAS 110
Material standard ASTM D1970 2015
TAS 110
Material standard TAS 103 2020
TAS 110
Material standard ASTM D6163 2015
TAS 110
Material standard ASTM D6164 2011
TAS 110
Material standard ASTM D6222 2011
TAS 110
Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST 6049)
TAS 114(J)
11757.08.01-1
9/13/2001
ERD (TST 6049)
TAS 114(C)
P1740.01.07
1/4/2007
ERD (TST 6049)
ASTM D1623, TAS 103
P31030.11.09-1
11/30/2009
ERD(TST 6049)
TAS 117(B)/TAS 114(C)
P11030.11.09-2
11/30/2009
ERD (TST 6049)
ASTM D4977 / TAS 103
P11030.11.09-3
11/30/2009
ERD (TST 6049)
ASTM D3970, D4798
P37300.10.11
10/19/2011
ERD(TST 6049)
TA5103
P40390.08.12-1
8/6/2012
ERD (TST 6049)
ASTM D1623, TAS 103
P40390.08.12-2
8/7/2012
ERD (TST 6049)
ASTM D1623, TAS 103
C41420.09.12-3
9/11/2012
ERD(TST 6049)
ASTM D6509
P37590.03.13-1-R1
2/5/2013
ERD (TST 6049)
TAS 114(J)
P39680.03.13
3/4/2013
ERD (TST 6049)
ASTM D6164
P37590.03.13-3A
3/6/2013
ERD (TST 6049)
ASTM D6164
P37590.07.13-1
7/2/2013
ERD (TST 6049)
ASTM D4601
P45940.09.13
9/4/2013
ERD (TST 6049)
ASTM D1623, TAS 103
P45270.05.14
5/12/2014
ERD (TST 6049)
ASTM D1623, TAS 103
6020.09.14-6
9/8/2014
ERD (TST 6049)
TAS 103
P44360.10.14-R1
10/7/2014
ERD (TST 6049)
ASTM D1970, D4798
P43290.10.14
10/17/2014
ERD (TST 6049)
TAS 114(J)
P39680.03.13
3/4/2013
ERD (TST 6049)
ASTM D1970, D4798
PLYG-SC10130.06.16-1
6/27/2016
ERD (TST 6049)
ASTM D1623, TAS 103
PLYG-SC10130.06.16-2
6/27/2016
ERD (TST 6049)
TAS 103
PLYG-SC10130.06.16-3
6/27/2016
ERD (TST 6049)
TAS 103 (tile slippage)
PLYG-sC13040.12.16
12/27/2016
ERD (TST 6049)
TAS 103 (tile slippage)
PLYG-SC12115.08.17
8/8/2017
ERD (T5T 6049)
TAS 103
PLYG-SC13035.08.17
10/31/2017
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18
3/29/2018
Eniinf
Examination
Reference
Date
NEMO (T5T 6049)
ASTM D1623, TAS 103
45-ICP-18-001.07.18-R1
7/23/2018
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A
1/24/2019
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C
5/20/2019
NEMO (TST 6049)
TAS 103
45-PLYG-18-004.10.19-G
10/8/2019
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.10.19-1
10/8/2019
NEMO (TST 6049)
TA5 103
4S-PLYG-18-004.10.19-L
10/9/2019
NEMO (TST 6049)
TAS 103
4S-PLYG-18-004.12.19-F
12/18/2019
NEMO (TST 6049)
TAS 103
4i-PLYG-I9-SSUDL-02.A
1/2/2020
NEMO (TST 6049)
ASTM D1970, D4798
4S-PLYG-18-004.01.20.H
1/14/2020
NEMO (TST 6049)
ASTM D1970,D4798
45-PLYG-18-004.01.20.K
1/14/2020
NEMO (TST 6049)
TAS 103 (tile slippage)
45-PLYG-18-004.01.20.A
1/16/2020
NEMO (TST 6049)
ASTM D6164
4S-PLYG-18-004.01.20.B
1/16/2020
NEMO (TST 6049)
TAS 103
PLYG-SC15855.05.20.A
5/29/2020
NEMO (TST 6049)
TAS 103
41-PLYG-20-SSUDL-01
7/6/2020
NEMO (TST 6049)
ASTM D6222
4q-PLYG-I9-SSMBB-0S.A
7/23/2020
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-I9-SSUDL-05.A
9/10/2020
NEMO (TST 6049)
ASTM D1970
4j-PLYG-20-SSUDL-05.A
9/30/2020
NEMO (T5T 6049)
TAS 103
4j-PLYG-20-SSUDL-05.0
9/30/2020
NEMO (TST 6049)
TAS 103
41-PLYG-20-SSUDL-i1.A
10/21/2020
NEMO (TST 6049)
ASTM D1970, D4798
45-PLYG-18-004.12.19.D
10/27/2020
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-SSLAP-01.A
12/15/2020
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-20-SSUDL-13.A
03/02/2021
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-SSUDL-03.A
03/04/2021
NEMO (TST 6049)
ASTM D1623, TAS 103
4j-PLYG-20-SSUDL-07.A
04/07/2021
UL (QUA9625)
Quality Control
Service Confirmation (FL)
09/13/2018
UL (QUA9625)
Quality Control
Service Confirmation (TX)
11/07/2019
UL (QUA9625)
Quality Control
Florida BCIS
Current
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization N32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 2 of 11
74.
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
C4.9
4.10
4.11
4.12
4.13
4.14
ONEMO I etc.
PRODucT DESCRIPTION:
Product
Material Standard
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
TAS 103 (partial)
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
TAS 103 (partial)
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate surface
Polystick MTS Plus
ASTM D1970
FL, NV, PA,
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
TX
membrane, glass fiber reinforced, surfaced with poly -film
surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m' polyester fabric surface
Polystick TU P
TAS 103
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a granular
surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, surfaced with a textured
film surface
S. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
/Certificate of Authorization #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 3 of 11
*NEMO I etc.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section:
TAS 110(S10),
TAS 110(S11),
RAS 133
TAS 110(5II)
RAS 130
RAS 115
RAS 118, 119 & 120
Underlayment
Asphalt
Clay and Concrete Tile
Metal
Slate or Slate-
Wood
Mechanical Attach
Adhesive -Set
Shingles
Type Shingles
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase
(Alternate to
(as Base Sheet,
as Base Sheet, (
(Alternate to
(Alternate to
(Alternate to
D226, Type II)
See 5.8)
See 5.8)
D226, Type II)
D226, Type II)
D226, Type II)
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Alternate to
(as Base Sheet,
as Base Sheet, (
(Alternate to
(Alternate to
(Alternate to
D226, Type II)
See 5.8)
See 5.8)
D226, Type II)
D226, Type II)
D226, Type II)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(See 5.6.1)
Elastoflex 56 G FR
No
Yes
No
No
No
No
Polyflex G
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex SA P FR
No
Yes
No
No
No
No
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes
Yes
No
Yes
(See 5.6.1)
Polystick TU P
No
Yes
No
No
No
Yes
Polystick TU Plus
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.6.1)
Polystick XFR
Yes
Yes
No
Yes
Yes
Yes
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE IA: ALLOWABLE UNDERLAYMENT /
TILE -ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product
Approval
Polystick TU Max, Polystick TU P or Polystick TU Plus
y y
DAP Foam "Touch 'n Seal
NOA 20-0309.05
Storm Bond Roof Tile Adhesive"
Polystick TU Max or Polystick TU Plus
Dupont "Tile Bond` Roof Tile
FL22525
Adhesive"
Elastoflex 56 G, Polyflex G, Polyflex SA P, Polystick TU Max, Polystick TU P
ICP Adhesives and Sealants
or Polystick TU Plus
"Polyset® AH-160"
NOA 17-0322.03
Polystick TU Max, Polystick TU P or Polystick TU Plus
ICP Adhesives and Sealants
NOA 18-0131.02
"Polyset® RTA-1"
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-RI
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 4 of 11
5.7
5.8
5.9
5.10
NNEMO I etc.
Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type
Primer
Material(s)
Polystick IR-Xe, Polystick MTS Plus,
Deck
ASTM D41
structural concrete
Polystick TU Max, Polystick TU P,
Polystick TU Plus, Polystick XFR,
self -adhering
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P
Polyflex SA P or Polyflex SA P FR
Elastoflex 56 G or Elastoflex S6 G
Deck
ASTM D41
structural concrete
FR
hot asphalt
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P
Polyflex G or Polyflex G FR
torch -applied
Deck
ASTM D41
structural concrete
Base Sheet
N/A
Elastobase, Elastobase P
Attachment Limitations:
Refer to Section 6
Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Mechanically attached
30
Polystick IR-Xe
Mechanically attached
90
Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick
XFR
Any type (per Table 1)
180
Elastoflex S6 G, Polyflex G or Polyflex SA P
Adhesive -set tile roof system
180
Elastoflex S6 G, Elastoflex S6 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or
Polyflex SA P FR
Mechanically attached
UNLIMITED
Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-Rl
Certificate of Authorization #32455 7'" EDITION (2020) FBC HVHZ EVALUATION FL5259-1133 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 5 of 11
NNEM01 etc.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3
6.3.1
Approved Assemblies:
Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Underlayment mechanically fastened to deck
Underlayment: One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles.
6.3.2 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.3 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E
Base Sheet:
Fastening:
Cap Ply:
Surfacing:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Elastoflex 56 G FR applied in hot asphalt or
Polyflex G FR torch -applied or
Polyflex SA P FR or Polystick TU P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 6 of 11
NNEMO I etc.
6.3.4 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o,c.
in a grid -pattern between the overlaps.
Cap Ply: Polystick IR-Xe self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
6.3.5 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch D.C. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.6 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 7 of 11
6.3.7 1 Deck Type 1: Wood, Non -Insulated NNEM0 I etc.
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.8 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.9 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E
Base Sheet:
Fastening:
Cap Ply:
Surfacing
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 8 of 11
NNEMO I etc.
6.3.10 I Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.11
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 2-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-inch o.c. at the lap -edges and 18-inch o.c. in two (2)
equally spaced, staggered center rows.
Cap Ply: Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied
and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
6.3.12 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Cap Ply: Polyflex SA P FR or Polystick TU P, self -adhering, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization #32455 7'" EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 9 of 11
NNEMO I etc.
6.3.13 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck,
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.14 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.15 1 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R1
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 10 of 11
6.3.16 1 Deck Type 1: Wood, Non -Insulated NNEMO I etc.
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates
Base Ply: (Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.17 1 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Underlayment: Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
6.3.18 1 Deck Type 3: Structural concrete, non -insulated
Deck Description: Min. 2,500 psi structural concrete
System Type F: Underlayment adhered
Primer: ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhering
Cap Ply: Polystick TU Max or Polystick TU Plus, self -adhering
Surfacing: FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and
Table 4 for tile stagging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS: I
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
QUALITY9.
UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC. Evaluation Report 3m-PLYG-20-FBCER.A-R3
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL5259-R33 (HVHZ)
Polyglass Roof Underlayments Revision 1: 04/07/2021
Page 11 of 11