HomeMy WebLinkAboutHi-Tide - Cuda Gear - 12,000 Lbs. Permit Drawing - Freeland 12-16-21ENGINEERING REVIEW: BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITh WIND LOAD REQUIREMENTS OF THE 7TH EDITION (2020) FLORIDA BUILDING CODE, PER ASCE 7-16, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOCIAT/nN's ALUMINUM DESIGN MAN BEAMS AND MOUNTING BRAC INSTALLED PER HI -TIDE INSTRUCTION EXCEED ULTIMATE DESIGN WIND SPE 200 MPH (EXPOSURE CATEGORY C BOATS ARE TO BE REMOVED FROM I LIFTS PRIOR TO A MAJOR WIND EV PILINGS: PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB -SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH 2020 FBC. ALL PILINGS TO BE 8" MINIMUM DIAMETER 2.5 C. C. A PRESSURE TREATED WOOD, PRE -STRESSED CONCRETE OR COMPARABLE EQUIVALENT. ELECTRICAL REVIEW.- 3/4 HP ELECTRIC MOTOR 10.8 AMPS @ 115V EACH 5.4 AMPS @ 230V EACH QUANTITY: 2 TOTAL WATTS. 2484 oger Babe" p. Digitally signed by Roger M BABER DN: c=US, o=Sustainable Earth Engineers dba MCR Engineers, ou=A0141 OD0000017183ADA 33C00001860,cn=Roger M BABER Date: 2021.12.16 08:09:06 -05,00, NOTE TO EXAMINER: THIS CERTIFIED ENGINEERED DRAWING HAS BEEN PREPARED SPECIFICALLY FOR USE ONLY BY.• SUMMERLIN'S MARINE CONST. °°°°000a000000u°°°°0 o°° R m a 0000Oo O e " NO.4438�5 � STATE OF <v o o�sAl<ORI®����°° 00000 8 °pO N°ol00000 0"s ROGER BABER P.E. NO. 43855 CR PROFESSIONAL ENGINEERING 2430 NE DIXIE HWY ✓ENSEN BEACH, FL 34957 ING MOUNTING TABS MUM (2) 3/8" DIA. SS LAG TS FOR WOOD PILING OR CONCRETE ANCHORS FOR CRETE PILINGS PER PILING IUIRED.M/N/MUM (2) 3/8" SS CARRIAGE BOLT FOR H i 119CH/NG MOUNTING TAB TO LIFT REQUIRED PER PILING. MOUNTING TAB CONSTRUCTED FROM 1/4" X 2" ALUMINUM 6 0 6 1- T 6 F L A T B A R. 12,000 LB. CODA GEAR BOATLIFTS AND MARINE PRODUCTS BOAT LIFT (2020 FBC) �� L 4050 SELVITZ ROAD FORT PIERCE, FL J4981 R. HYDE SCALE: NTS DATE.• 1/4/21 REV: 1 1-800-544-0735 www.hi-tide.com DESCRIP770V