Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
f� e� Loa ' Short Form RECEIVED lob: 1688 Air Cales, LLC „ bate: Dec 09, 2021 AI l T 3y. Vicki Lynne Nisa FEB 0' 7 2022 Air CaIcs, LLC ix �fi hI� i. 7550 Hidden Hammock LR Vero Beach, FL32966 Ph3ne:772.800.8413 Email: viddlyme@aircalcs.com s Prpject Information For: MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Htg Clg Infiltration Outside db (°F) 41 90 Method Blower door Inside db (°F) 70 75 Shielding / stories 3 (partial) / 3 Design TD (°F) 29 15 Pressure /AVF 50 Pa / 3213 cfm Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 2 57 HEATING EQUIPMENT Make Carrier Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 11.4 kW 38898 Btuh 19 °F 1900 cfTn 0.046 cfm/Btuh 0.70 in H2O COOLING EQUIPMENT Make Carrier Trade CARRIER Cond 24APB660A00300 Coil FX4DNB061 L AHRI ref 201778739 Efficiency 13.0 EER. 16 SEER Sensible cooling 39900 Btuh Latentcooling 17100 Btuh Total cooling 57000 Btuh Actual airflow 1900 cfrn Airflowfactor 0.044 cfmA3tuh Static pressure 0.70 in H2O Load sensible heat ratio 0.81 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIgAVF (cfm) Flex Space 364 6995 5728 319 255 Hallway 144 0 0 0 0 Foyer 174 6396 2952 292 131 Storage 43 1202 332 55 15 1 st Fir Laundry 80 2127 1852 97 82 Dining Room 215 4959 4948 226 220 Ocean Room 378 9561 14315 436 636 Kitchen 322 2522 5733 115 255 2nd Fir Laundry 97 1338 1541 61 69 A/C 1 16 0 0 0 0 Bed 4 199 2920 3128 133 139 Bath 4 62 781 915 36 41 Pwdr Rm 60 . 1269 874 58 9 2nd Fir Hall 166 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Et1, W t 1 wrightsoft® 2021-Deo 1012:5639 �''+�•-- wR•� ��.a• �ma•> RightSute®Uriversal202121.0.10R5U27054 Pagel .-ocunerds\WrigKsoft HVACk816 Watersorg Waynp Caic= MJ8 Frort Door faces: W s 5 !,MIL ru crcv q ea U U I U U 2nd Flr Elev a 23 0 0 ' 0 0 Cabana 124 1556 426 e1 19 Stairs 2nd Flr ' 85 0 0 "0 0 1stFlrStairs 94 0 0 0 0 _. s AM 1 d 1 2668 41626 42744 1960 1900 Other equip loads ? 1249 663 Equip. @ 0.95 RSM 41410 Latent cooling 10123 Tr)TAl C 7RRR A')R7G r1 r;212 I I onn onn ins approved byACCA to meet all requirements of Manual J 8th Ed. _ -F' F- wrightsoft- { 2021-Dec-1012:5639 n MRaNIBMNWH.N.+q CnmronY Rlgtt SUWe lhiversal 202121-.0.10 RSU27054 Paget xCKoaxm trXWdgttsoft HVACW816 Watersorg WayrLp Calc= MJ8 Frort Door faces: W { Air Calcs LLC Load Short Form Job: 1688 Date: Dee 09, 2021 AN 2 By. fjVcki Lynne Nisa Air Calcs,1�'LC 5 4 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772�00.8413 Email: vicldlynrie@aircalcs.com For: MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Htg Clg Infiltration Outside db (°F) 41 90 Method Blower door Inside db (°F) 70 75 Shielding / stories 3 (partial) / 3 Design TD (°F) 29 15 Pressure /AVF 50 Pa / 3213 cfm Daily range - L Inside humidity (%) 30 50 Moisture difference (grAb) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Carrier Trade Trade CARRIER Model Cond 24APB636AO0300 AHRI ref Coil FX4DNF037L AHRI ref 201779971 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.0 kW Sensible cooling 23940 Btuh Heating output 23808 Btuh Latent cooling 10260 Btuh Temperature rise 19 °F Total cooling 34200 Btuh Actual airflow 1140 cfin Actual airflow 1140 cf n Air flow factor - 0.054 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (Cfm) CIgAVF (crm) Master Bedroom 391 6.331 7815 343. 389 M Hall 36 0 0 0 0 Hers 93 - 887 435 48 22 Master Bath 163 3307 3473 179 173 Wtr Clst 25 479 399 26 20 3rd Fir Stairs 95 911 733 49 37 Loft 112 2387 3263 129 163 Bath 3 69 948 1050 51 52 Bed 3 175 2865 2622 155 131 WIC 3 35 326 162 18 8 A/C 2 15 0 0 0 0 Bath 2 55 605 441 33 22 Bed 2 188 1571 2272 85 113 \Atir 7 7= 474 4 r;7 47 a byACCAto meet all requirements of Manual J 8th Ed. -�- wrightsoftm Righl-Sute@Uriversal202121.0.10RSU27054 ...oamertAWdgftwftWACW816WatersorgWayW Calc=W8 FrortDooriaoas: W 2021-Dec-1012:56:39 Page 3. y His 56 102 71 6 4 3rd Fir Elev 25 0 0 0 0 3rd Fir Hall 134 0 0 0 0 AM 2 d 1690 21040 22888 1140 n .'�? 1140 Other equip loads 777 413 Equip. @ 0.95 RSM 22229 Latent cooling , 5421 ' TOTALS 1690 21817 27651 1140 1140 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. f wrightsoft® I gMrt.N/ewnw WNn..y Ump� Right -Sate® LM.Isa1202121.0.10 RSU27054 .-oamerds\WriglisoftWAC\4816WatersorgWaynp Calc=MJ8 Frort Door faces: W 2021-Deo-1012:5639 Page 4 I& Air Calcs, LLC Build A/H 1 Air Cal 7550 Hidden Hammock LR Vero Beach, FL32966 Phoi For. Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28 °N Outdoor: Dry bulb (°F) Daily range (T) Wet bulb (T) Wind speed (mph) 1 Analysis LLC !.800.8413 Email: viddlyrre@aircalcs.com MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Indoor: Indoor temperature (T) Design TD (T) Relative humidity (%) Heating Cooling Moisture difference (gr/Ib) 41 90 Infiltration: - 15 ( L ) Method 77 Shielding / stories 15.0 7.5 Pressure /AVF Component Btuhtff Btuh % of load Walls 2.5 7360 17.2 Glazing 24.7 15181 35.4 Doors 0 0 0 Ceilings 1.5 207 0.5 Floors 3.1 5396 12.6 Infiltration 2.1 6557 15.3 Ducts 6926 16.2 Piping 0 0 Humidification 0 0 Ventilation 1249 2.9 Adjustments 0 Total 42875 100.0 Component Btuh/ft2 Btuh % of load Walls 1.5 4450 10.3 Glazing 27.9 17186 39.6 Doors 0 0 0 Ceilings 1.1 159 0.4 Floors 0 0 0 Infiltration 0.7 2067 4.8 Ducts 4632 . 10.7 Ventilation 663 1.5 Internal gains 14250 32.8 Blower 0 0 Adjustments 0 Total 1 1 43407 100.0 Latent Cooling Load =10123 Btuh Overall U-value = 0.189 Btuh/fF-°F Data entries checked. wriahtsc3ft® a .� ^ -�^��• -�� ^w PighFSdte® Universal 2021 21.0.10 RSU27054 !� oamentsUrightsoft WACW816 Watersorg Waynp 'Calc= MJ8 Front Door faces: W Glazinc Glazing Job: 1688 Dab;: Dec 09, 2021 By'.:�11 Vicki Lynne Nisa Heating Cooling 70 75 29 15 30 50 2.4 56.9 Blower door 3 (partial) / 3 50 Pa / 3213 d n Gains 2021-Deo•1012:5639 Page 1 t Air Calcs, LLC Buildingl nalysis A/H 2 Air Calcs, L�LC 4 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.00.8413 Email: viddlynna@aircalcs.com For. MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28 °N Outdoor: Heating Dry bulb (T) 41 Daily range (T) - Wet bulb (T) - Wind speed (mph) 15.0 Indoor: Indoor temperature (T) Design TD (T) Relative humidity (%) Cooling Moisture difference (grAb) 90 Infiltration: 15 (L ) Method 77 Shielding / stories 7.5 Pressure /AVF Component Btuh/ftz Btuh % of load Walls 2.3 3694 16.9 Glazing 24.4 6954 31.9 Doors 0 0 0 Ceilings 1.5 2504 11.5 Floors 1.4 152 0.7 Infiltration 2.1 4092 18.8 Ducts 3643 16.7 Piping 0 0 Humidification 0 0 Ventilation 777 3.6 Adjustments 0 Total 21817 100.0 Component Btuh/ft2 Btuh %of load Walls 1.5 2363 10.1 Glazing 30.2 8631 37.0 Doors 0 0 0 Ceilings 1.1 1920 8.2 Floors 0 0 0 Infiltration 0.7 1290 5.5 Ducts 2434 10A Ventilation 413 1.8 Internal gains 6250 26.8 Blower 0 0 Adjustments 0 Total 23301 100.0 Latent Cooling Load = 5421 Btuh Overall U-value = 0.277 Btuh/ftz-°F Data entries checked. C -- wr7gtr.tsoft® • •w•^••6inw^� Rigtf-Sute®Uriversa1202121.0.10RSU27054 14M ..oairnerds\WrigHsoftWACW816WatersorgWaynp Cald=MJ8 Front Door faces: W Glazing Glazing Ceilings Job: �11688 Date: Dec 09, 2021 By. tvicki Lynne Nisa Heating Cooling 70 75 29 15 30 50 2.4 56.9 Blower door 3 (partial) / 3 50 Pa / 3213 cfm Infiltration Gains 2021-Deo-1012:5639 . . Page 2 ti It Air Calcs LLC Componefit Constructions AN 2 :i - Air Calcs, LL( 7550 Hidden Hammock LR Vero Beads, FL32966 Phone: 772.800.t 13 Email: viddlyme@alrcalcs.com Job: 16£B Date: Des; 09, 2021 By,. Vicki Lynne Nisa Project• • For. MadoArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Inti, FL, US Indoor temperature (T) 70 75 Elevation: 26 ft Design TD (T) 29 15 Latitude: 28'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (T) 41 90 Infiltration: Daily range (T) - 15 (L ) Method Blower door Wet bulb (T) - 77 Shielding / stories 3 (partial) / 3 Wind speed (mph) 15.0 7.5 Pressure /AVF 50 Pa / 3213 cfrn .construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft, Bann'- F re- F Ban Bttnh' Ban Bang' Ban Walls Block R-9 Wall: Blk Wall. Stuc 6d. 8" Thk. R-9 Foam Fill. R-11 Foam ne 663 0.079 10.0 2.28 1510 1.46 966 Interior Ins. 1 /2" Gyp Bd se 165 0.079 10.0 2.28 376 1.46 240 sw 630 0.079 10.0 2.28 1435 1.46 918 - nw 164 0.079 10.0 2.28 373 1.46 239 all 1622 0.079 10.0 2.28 3694 1.46 2363 Partitions (none) Windows Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; ne 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang ne (4 ft window ht, 1 ft sep.); 8 ft head ht ne sw all Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; se 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (4 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; se 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang yw (5 ft window ht, 1 ft sep.); 8 ft head ht - all Impact: Impact; NFRC rated (SHGC=0.21); foreground = green grass se (0.23); 6 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.31); 50% blinds 45°, medium; nw 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.30); foreground = green grass nw (0.23); 9 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings Attic, Metal Roof, R-22 Roof Deck Ins, 5/8" Gyp Bd Int Fnsh 8 0.780 0 22.6 181 27.5 220 20 0.780 0 22.6 452 27.5 550 21 0.780 0 22.6 483 27.5 587 8 0.780 0 22.6 181 21.6 173 57 0.780 0 22.6 1297 26.7 1531 16 0.780 0 22.6 362 16.8 269 20 0.780 0 22.6 452 22.9 458 20 0.780 0 22.6 452 22.9 458 40 0.780 0 22.6 905 22.9 916 48 0.670 0 19.4 933 12.3 591 44 0.780 0 22.6 999 29.1 1285 80 1.060 0 30.7 2459 38.9 3110 1690 0.386 23.0 1.48 2504 1.14 1920 f}h wrightsoft- I 2021-Deo-1012:56:40 14M. Right-Sdte® Urtversa12021 21.0.10 RSU27054 .-oc merds\WrigNsoft HVACW816 Waterso Wa Page 1 rg ynp'CaIc=MJ8 FrortDoorfaces: W Floors 8" Thkns Concrete Hollow Core, R-19 Spray Foam Ins -Fk wrightsoft® ! PigFfSute® Universal 2021 21.0.10 RSU27054 oamerds�WrigtboftWACW816WatersorgWayrtp Calc=MJ8 Frort Door faces: W 107 0.049 19.0 1.42 0 12:56:40 Page 2 Air Calcs, LLC Compon;nt Constructions A/H 1 ; Air Calcs, Lc 7550 Hidden Hammock LR Vero Beach, FL32966 Phone: 772.600.8413 Email: vidk lyme@aircalcs.com For: Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28 °N Outdoor: Dry bulb (T) Daily range (T) Wet bulb (T) Wind speed (mph) MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Job: 1688 Date: 03ec 09, 2021 By: ✓icki Lynne Nisa Indoor: Heating Cooling Indoor temperature (T) 70 75 Design TD (T) 29 15 Relative humidity (%) 30 50 Heating Cooling Moisture difference (gr/Ib) 2.4 56.9 41 90 Infiltration: - 15 (L ) Method Blower door 77 Shielding / stories 3 (partial) / 3 15.0 7.5 Pressure /AVF 50 Pa / 3213 cfrn Construction descriptions Or Area U-value Insul R Htg HTM . Loss Clg HTM Gain fe BnnM F rr- F Bnn EhL^le Bnn RLAhW BM Walls Block R-9 Wall: Blk Wall. Stuc Ext. 8" Thk, R-9 Foam Fil, R-11 Foam n 25 0.079 10.0 2.28 57 1.46 36 Interior Ins. 1/2" Gyp Bd ne 689 0.079 10.0 2.28 1569 1.46 1004 Partitions Frm Wan. 1/2"Gyp Bd Ext. R-11 Cav Ins. 1/2"Gyp Bd Int Fnsh, 2'hKT Metal Fnn, 16" OC Stud se 298 0.079 10.0 2.28 679 1.46 435 sw 1133 0.079 10.0 2.28 2580 1.46 1650 nw 297 0.079 10.0 2.28 675 1.46 432 an 2442 0.079 10.0 2.28 5561 1.46 3557 541 0.115 11.0 3.33 1799 1.65 893 Windows Impact: Impact; NFRC rated (SHGC=0.30); 50% blinds 45°, medium; n 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang (10 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.28); 50% bends 45°, medium; ne 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang ne (4 ft window ht, 1 ft sep.); 8 ft head ht sw all Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; ne 50% outdoor insect screen; foreground = green grass (0.23); 2 ft overhang ne (4.7 ft window ht, 1 ft sep.); 8 ft head ht sw all Impact: Impact; NFRC rated (SHGC=0.20); 50% blinds 45°, medium; ne 50% outdoor insect screen; foreground =•green grass (0.23); 2 ft overhang ne (2 ft window ht, 1 ft sep.); 8 ft head ht ne - sw all Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; se 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (4 ft window lit, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.21); foreground = green grass se (0.23); 5 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht h - pwrightsoft® .• .a •U-,� ,, Flight-Srite@)Lkiiersal202l2l.O.lORSU27054 .-oamerds\WrightsoftWACW816WatersorgWayne'Calk=MJ8 FrortDoor faces: W 59 1.060 0 30.7 1819 19.0 1124 13 0.780 0 22.6 302 27.5' 367 21 0.780 0 22.6 467 27.5 569 11 0.780 0 22.6 241 21.6 231 45 .0.780 0 22.6 1010 26.1 1166 12 0.780 0 22.6 266 27.5 323 38 0.780 0 22.6 851 27.5 1035 24 0.780 0 22.6 532 22.6 530 73 0.780 0 22.6 1648 25.9 1888 7 0.800 0 23.2 155 23.6 157 5 0.800 0 23.2 116 23.6 118 16 0.800 0 23.2 371 23.6 377 10 0.800 01~ 23.2 232 16.0 160 38 0.800 0 23.2 874 21.6 812 16 0.780 0 22.6 362 16.8 269 48 0.670 0 19.4 933 13.1 627 2021-Deo-1012:56:40 i Page 3 sS Impact: Impact; NFRC rated (SHGC=0.21); foreground= green grass se 48 0.670 0 19.4 i1933 12.3 591 (0.23); 6 ft overhang (8 ft window ht,1 ft sep.); 8 ft hear]. ht r� Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds'45% medium; 50% outdoor insect screen; foreground = green grass 6-23); 2 ft overhang sw 21 0.780 0 22.6 ;479 21.8 462 (4.1 ft window ht, 1 ft sep.); 8 ft head ht j Impact: Impact; NFRC rated (SHGC=0.28); 50% blinds 45°, medium; sw 36 0.780 0 22.6 806 24.3 865 50% outdoor insect screen; foreground = green grass (( .23); 2 ft overhang >� (6.9 ft window ht, 1 ft sep.); 8 ft head ht { Impact: Impact; NFRC rated (SHGC=0.21); 50%outdoor insect screen; nw 48 0.670 0 19.4 ^933 17.6 843 foreground = green grass (0.23); 10 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.30); foreground = green grass nw 160 1.060 0 30.7 4918 38.9 6220 (0.23); 10 ft overhang (10 ft window ht, 1 ft sep.); 8 ft head ht Impact: Impact; NFRC rated (SHGC=0.21); foreground = green grass nw 24 0.670 0 19.4 466 26.7 641 (0.23); 10 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings Attic, Metal Roof, R-22 Roof Deck Ins, 5/8" Gyp Bd Int Fnsh 140 0.386 23.0 1.48 207 1.14 159 Floors 8" Thkns Concrete Hollow Core. R-19 Spray Foam Ins 53 0.049 19.0 0.71 37 0 0 618 0.049 19.0 0.71 439 0 0 all 671 0.049 19.0 0.71 476 0 0 On Grade Depth, Tile Flr Fnsh 171 0.989 0 28.7 4904 0 0 Part Floor, 8" Thkns Concrete Hollow Core, R-19 Spray Foam Ins. 4 0.119 1.0 3.45 15 0 0 Suspended Ceiling Bd ! 2021-Dec-1012:56:40 Wri�ghtsOft® PjgWSrite®Uriversal202121.0.10RSU27054 i Page oamerds\Wrighlsoft WACW816 Watersorg Wayirp Calc= MJS Fro t Doorfaoes: W Air Calcs, LLC aH;ctSur Air Calcs, LLC 7650 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.841 q1 Email: viddlM@aircalcs.com For: MarioArbucci, Coastal Construction and Desiggn, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db 41 OF Inside db 70 OF Design TD 29 OF Heating Summary Structure 34700 Btuh Duds 6926 Btuh Central vent (39 cfm) 1249 Btuh Outside air Humidification Piping Equipment load Infiltration Method Shielding / stories Pressure /AVF 0 Btuh 0 Btuh 42875 Btuh Blower door 3 (partial) / 3 50 Pa /13213 cf n Heating2668 Cooling2668 Area (ft2) Volume (fta) 27825 27825 . Airchanges/hour 0.44 0.26 Equiv AVF (cfm) 206 122 Heating Equipment Summary Make Carrier Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Calculations Job: 1688 Date: Dec 00 2021 By. Vicki 0ne Nisa Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 grAb Sensible Cooling Equipment Load Sizing Structure 38112 Btuh Duds 4632 Btuh Central vent (39 cfm) 663 Btuh Outside air Blower 0 Btuh Use manufacturers data n Rate/swinq multiplier 0.95 Equipment sensible load 41410 Btuh Latent Cooling Equipment Load Sizing Structure 5719 Btuh Ducts 2890 Btuh Central vent (39 cfm) 1514 Btuh Outside air Equipment latent load 10123 Btuh Equipment Total Load (Sen+Lat) 51533 Btuh Req. total capacity at 0.70 SHR 4.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 24APB660A00300 Coil FX4DNB061L AHRI ref 201778739 100 EFF Efficiency 13.0 EER,16 SEER 11.4 kW Sensible cooling 39900 Btuh 38898 Btuh Latentcooling 17100 Btuh 19 OF Total cooling 57000 Btuh 1900 cfm Actual airflow 1900 cfm 0.046 cfm/Btuh Airflowfactor 0.044 cfm/Btuh 0.70 in H2O Static pressure 0.70 in H2O Load sensible heat ratio 0.81 i pproVed byACCAto meet all requirements of Manual J 8th Ed. S -Fk- wrightsoft- 2021-13eo-1012:56.40 Right -Sate® Universal 2021 21.0.10 RSU27054 Page 1 Jc` ..Mc mentMrighlsoft WAC\4816 Watersorg Waynp C.alc= MJ8 Front Door faces: W Air Caics, LLC '�1 Project Summery A/H 2 Air Caics, LLC j 7550 Hidden Hammock LR Vero Bead, FL32966 Phone:772.800.8413 For: MarioArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db 41 °F Inside db 70 °F Design TD 29 °F Heating Summary Structure 17397 Btuh Duds 3643 Btuh Central vent (24 cfm) 777 Btuh Outside air Humidification Piping Equipment load Infiltration Method Shielding / stories Pressure /AVF 0 Btuh 0 Btuh 218177 Btuh Blower door 3 (partial) / 3 50 Pa 13213 cfm He ting ing Co 1690 Area (fF) 1690 Volume (fi3) 16898 16898 Air changes/hour 0.46 0.27 Equiv. AVF (cfm) 128 76 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Calculations 1 J Job: 1688- } Date: Dec 09, 2r1121 By. Vicki Lynr:a Nisa 1 Summer Design Conditions Outside db 90 °F Inside db 75 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 grAb Sensible Cooling Equipment Load Sizing Structure 20454 Btuh Duds 2434 Btuh Central vent (24 clim) 413 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Equipmen� sensible load 22229 Btuh Latent Cooling Equipment Load Sizing Structure 2945 Btuh Ducts 1534 Btuh Central vent (24 cfm) 943 Btuh Outside air Equipment latent load 5421 Btuh Equipment Total Load (Sen+Lat) 27651 Btuh Req. total capacity at 0.70 SHR 2.6 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 24APB636AO0300 Coil FX4DNF037L AHRI ref 201779971 100 EFF Efficiency 13.0 EER,16 SEER 7.0 kW Sensible cooling 23940 Btuh 23808 Btuh Latentcooling 10260 Btuh 19 °F Total cooling 34200 Btuh 1140 cfm Actual airflow 1140 cfm 0.054 cfm/Btuh Airflowfactor 0.050 cfm/Btuh 0.70 in H2O Static pressure 0.70 in H2O Load sensible heat ratio 0.81 oproved•;,byACCAto meet all requirements of Manual J 8th Ed. wrightsoft• 2021-Dec-10.12:56:40 r+� •�^ ^w^- Right-Sute@ Wversal202121.0.10RSU27054 Paget ._oaments\WrightsoftWAC14816WatersorgWaynp Caic=MJ8 Front Doorfaoes: W 5: Air Calcs, LLC Right-JO Worksheet AIH 1 Air Calm, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.81L 3 Email: vic ilyme@aircalcs.com 11 Job: 1688 Data: Dec 09, 2021 By: Vicki' ynne Nisa :1 1 Room name / / AM Flex S{�oe 2 Exposed wall 345.8 It 56.0 t ft 3 Room height ! 10A ft d 10A It heatbool 4 5 Room dimensions Room area 2668A ft' 1.0 x 363.8 ft 363.8 ftz Ty Construction U-value Or HTM Area (IF) Load Area (fly Load number (BtuhAt;--O (Btu or perimeter (>?) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross NuPS Heat Cool Gross NIPS Heat Cool 6 yJ Block R-9 Wall 0.079 n 2.28 1.46 84 25 57 36 0 0 0 0 �G Impact 1.060 n 30.74 18.99 59 0 1819 1124 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 800 689 1569 1004 208 187 427 273 Impact 0.780 ne 22.62 27.52 13 0 302 367 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 21 0 467 569 21 0 467 569 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 12 0 266 323 0 0 0 0 Impact 0.780 ne 22.62 27.52 38 0 851 1035 0 0 0 0 Impact 0.800 ne 2320 23.59 7 0 155 157 0 0 0 0 Impact 0.800 ne 23.20 23.59 5 0 116 118 0 0 0 0 Impact 0.800 ne 23.20 23.59 16 0 371 377 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 410 298 679 435 52 52 118 76 Impact 0.780 se 22.62 16.82 16 16 362 269 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 48 43 933 627 0 0 0 0 Impact 0.670 se 19A3 12.30 48 48 933 591 0 0 0 0 Block R-9 Wall 0.079 9,v 2.28 1.46 1234 1133 2580 1650 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.64 11 6 241 231 0 0 0 0 Impact 0.780 sw 22.62 21.79 21 12 479 462 0 0 0 0 Impact 0.780 sw 22.62 22.57 24 11 532 530 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 2427 36 12 806 865 0 0 0 0 Impact 0.800 9ev 23.20 15.95 10 10 232 160 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 529 297 675 432 192 144 329 210 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19A3 17.56 48 0 933 843 48 0 933 843 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rnv 30.74 38.88 160 0 4918 6220 0 0 0 0 Impact 0.670 nw 19A3 26.70 24 0 466 641 0 0 0 0 P Frrn Wall.12" Gyp B 0.115 3.33 1.65 541 541 1799 893 130 130 432 215 C Alm Metal Roof. R 0.386 1.48 1.14 140 140 207 159 15 15 22 17 F 8" Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Ciorxrete Ho 0.049 0.71 0.00 53 53 37 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 0.71 0.00 618 618 439 0 0 0 0 0 F On Grade Depth. Tile 0.989 28.68 0.00 1047 171 4904 0 364 56 1606 0 F Part Floor.8"Thkns 0.119 3.45 0.00 4 4 15 0 0 0 0 0 61 c) AED excursion 1678 1-40 Envelope losslgain 28143 21795 4335 ' 2162 12 a) Infiltration 6557 2067 970 306 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 5 1150 0 0 Appliances/other 13100 2500 Subtotal (lines 6 to 13) 34700 38112 5305 4968 Less e)demal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 526 139 14 Subtotal 34700 38112 5831 5107 15 Dud loads 20% 12% 6926 4632 20% 12% 1164 621 Total room load 41626 42744 6995 5728 Air required (dm) 1900 1900 319 255 to meet all requirements of Manual J 8th Ed. -Fj*- wrYghtsoft^ .CA Right -Suite® Uriversall 2021 21.0.10 RSU27054 ._ocrnerds\WrigttsoftWAC\4816WatersorgWaysp Calc=MJ8 Front Door faces: W 2021-Dea1012:56:40 Page 1 _ a ( Air Cans, LLC Right-JO Wcrksheet-- A/H 1 Air Calcs, LLC A 7550 Hidden Hammock Lrt-Vero Beach, FL32966 Phone: 772.800.8413, Email: vidcilyme@aircaics.com ij Job: 1688 Date: Dec 09, i';021 By: Vicki Lyr�',je Nisa 1 Room name Hallvkey Foyer ; 2 FVosedvvall 21.0 It 37.5 It 3 Room height t 10A It heat/000l 10.4 It heat/000l 4 5 Room dimensions Room area 1.0 x 144.1 ft 144.1 ft' 20.5 x 8.5 It 174.3 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft') Load number (BtuhRl;°F) (BtuhAtz) or perimeter (ft) (Btuh) or perimeter ((t) (Btuh) Heat Cod Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.8W ne 2320 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 88 40 92 59 Impact 0.780 se 2262 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 13.06 0 0 0 0 48 43 933 627 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 213 192 437 280 Impact 0.780 sv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.79 0 0 0 0 21 12 479 462 Impact 0.780 sH 2262 22.57 0 0 0 0 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 2262 2427 0 0 0 0 0 0 0 0 Impact 0.800 sry 2320 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 rw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 rhv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 rnw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 26.70 0 0 0 0 0 0 0 0 P Frm Wall.12" Gyp B 0.115 3.33 1.65 218 218 727 361 88 88 294 146 C Atbc. Metal Roof. R 0.386 1.48 1.14 0 0 0 0 31 31 46 35 F U' Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 - 0.71 0.00 0 0 0 0 0 0 0 0 F 8" ThknsCorxrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 28.68 0.00 144 21 602 0 174 38 1076 0 F Part Floor. B Thkns 0.119 3A5 0.00 0 0 0 0 0 0 0 0 6 c) AFD exarsion -9 -48 Envelope loss/gain 1329 352 3356 1560 12 a) Infiltration 0 0 647 204 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 1329 352 4003 2264 Less od malload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1329 -352 1328 368 14 Subtotal 0 0 5331 2632 15 Dud loads 20% 12% 0 0 20% 12% 106 4 320 Total room load 0 0 6396 2952 Air required (dm) 0 0 2921131 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -� wrigFrtsoll�" - `"""" Right-Suite@Uriversa1202121.0.10RSU27054 ...c rnents\Wrightsoft HVAC14816 Watersorg Waynp Calc= MJ8 Front Door toes: W 2021-Dea1012:56.40 Page 2 :a Air Caics, LLC Right-JO Worksheet A/H 1 ' Air Calks, LLC ' 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Err�,iil:%ncldlyrre@aircaics.com .j i Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne visa 1 Room name Storage 1stRrLaundry 2 E)q)osedvall 5.0 It 18.0 It 3 Room height ? 10A ft heat/cool 10A It tieat(cool 4 Room dimensions 5.0 x 8.5 It 8.0 x 10.0 It 5 Room area 42.5 ft2 80.0 it' Ty Construction U-value Or HTM Area Load Area Load number (Btuh/If7*) (Btuw or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 I- ( Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impart 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 9N 2.28 1.46 52 52 118 76 83 83 189 121 Impact 0.780 sN 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 -0 0 Impact 0.780 sw 22.62 2427 0 0 0 0 0 0 0 0 Impact 0.800 sw 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 104 80 182 117 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 r w 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 rrw 19A3 26.70 0 0 0 0 24 0 466 641 P Frm Wall. 12" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Aft. Metal Roof. R 0.386 1.48 1.14 8 8 11 9 12 12 18 14 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 - 0.71 0.00 0 0 0 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 28.68 0.00 43 5 143 0 80 18 516 0 F Part Floor,8"Thkns 0.119 3A5 0.00 0 0 0 0 0 0 0 0 6 c) AED exarsion -3 132 Envelope lose/gain 273 81 1372 1024 12 a) Infiltration 112 35 401 127 b) Roomventilation 0 0 0 0 13 Intemal gains. Occupants @ 230 0 0 ' 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 384 116 1773 1651 Less exemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 618 180 0 0 14 Subtotal 1002 296 1773 1651 15 Ductloads 20% 12% 200 36 20% 12% 3% 201 Total room load 1202 W2 2127 1852 Airregdred(dm) 55 15 97 82 Calculations approved byACCA -f;'f1-' wri917tso4ft.. Right SriteS Universal 2021 21.0.10 RSU27054 oameNslwngttsoftWAC44816WatersorgWaynp Calc=MJB FrontDoorfaces:W 2021-13e3-1012:56:40 Page 3 Air Calcs, LLC Right-JO Wo A/H 1 Air Calks, LLC 7550 Hidden Hammock Ln, Vero Bead, FL32966 Phone:772.800.8413 1 F Job: 1688 4 Date: Dec 09, 2021 By: Vicki Lynne Nis'.1 1 Room name 3 Dining Room Ocean Room 2 Exposed wall 28.3 It 42.0 It 3 Room height 10.8 It heaVcool 10.8 It head000l 4 5 Room dimensions - Room area 1.0 - x 214.9 ft 214.9 It' 1.0 x 378.3 it 378.3 ft2 Ty Construction U-value Or HTM Area Load Area Load number (BtuhAF-'F) (Btuhkft� or perimeter (I1) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross NA'IS Heat Cool Gross NIPIS Heat Cool 6 % fBlock R-9 Wall 0.079 n 2.28 1.46 84 25 57 36 0 0 0 0 Impact Block R-9 Wall 1.060 0.079 n ne 30.74 2.28 18.99 1.46 59 157 0 103 1819 235 1124 150 0 0 0 0 0 0 0 0 --( W Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 38 0 851 1035 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impart 0.800 ne 23.20 23.59 16 0 371 377 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 2262 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 286 253 575 368 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9w 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 9w 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.57 0 0 0 0 24 11 532 530 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 2427 0 0 0 0 0 0 0 0 Impact 0.800 sw 23.20 15.95 0 0 0 0 10 10 232 160 Block R-9 Wall 0.079 nkv 228 1.46 65 65 148 94 167 7 17 11 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 rw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 160 0 4918 6220 Impact 0.670 nw 19.43 26.70 0 0 0 0 0 0 0 0 P Frrn Wall.12" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Attic, Metal Roof. R 0.386 1.48 1.14 0 0 0 0 13 13 20 15 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThknsCcrxrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 28.68 0.00 0 0 0 0 0 0 0 0 F Part Floor,8"Thkns 0.119 3A5 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -111 1655 Envelope loss(gain 3479 2705 6294 8959 12 a) Infiltration 655 206 973 307 b) Roomventlation 0 0 0 0 13 Internal gains: 'Occupants @ 230 0 0 3 690 Applianceslother 1500 2400 Subtotal (lines 6to13) 4134 4411 7267 12355 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 704 408 14 Subtotal 4134 4411 7970 12763 15 Duct loads 20% 12% 825 536 20% 12% 1591 1551 Total room load T4959 4948 9561 14315 Air required (cfrn) 226 220 436 636 NCCAto meet all requirements of Manual J 81 -� wrYgF�tso Wit" . GA Right Sute® Universal 2021 21.0.10 RSU27054 .-oc rnerds\Wrightsoft WACk1816 Watersorg Waynp Calc= MJ8 Front Doorfaces: W 2021-Dec-1012:58:40 Page 4 1� Air Caics, LLC Right-JO Wcrksheet A/H 1 .I Air Cales, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 ,Email: viddlynne@aircalcs.com 1 'l Job: 1688 Date: Dec 09, 2021 By. Vicki Lynne Nisa 1 Room name v Mchen 2nd Fir Launriry 2 Exposedvdl ' 19.5 It 10.5 ft 3 Room height s 10.8 It heat/000l 10.0 ft '. heaftol 4 Room dimensions 19.5 x 16.5 It 1.0 x 96.5 ft 5 Room area 321.8 ft' 96.5 ft' Ty Construction U-value Or HTM Area (IF) Load Area (fF) Load number (Btuh/W-'F) (BtuhAl� or perimeter (ft) (Btuh) or perimeter (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 211 191 434 278 105 88 201 129 Impact 0.780 ne 22.62 27.52 13 0 302 367 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 12 0 266 323 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 7 0 155 157 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 5 0 116 118 Impact 0.8W ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 as 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 9N 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.760 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sN 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 2427 0 0 0 0 0 0 0 0 Impact 0.800 9N 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 rrw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 rry 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 r1w 19.43 17.56 0 0 0 0_ 0 0 0 0 Impact 1.060 rry 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 26.70 0 0 0 0 0 0 0 0 P Frrn Wall.1/1" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Attic Metal Roof. R 0.386 1.48 1.14 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F U' Thkns Concrete Ho 0.049 0.71 0.00 53 53 37 0 0 0 0 0 F 6' Thkns Concrete Ho 0.049 0.71 0.00 220 220 156 0 97 97 69 0 F On Grade Depth, Tile 0.989 28.68 0.00 0 0 0 0 0 0 0 0 F Part Floor. 8 Thkns 0.119 3.45 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -113 -28 Envelope losstgain 1084 689 651 542 12 a) Infiltration 452 142 225 71 b) Room ventilation 0 0 0 0 13 Internal gains: Oompants@ 230 2 460 0 0 Applianceslother 3200 500 Subtotal (lines 6 to 13) 1535 4491 876 1113 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 567 621 239 261 14 Subtotal 2102 5112 1115 1374 15 Dud loads 20% 12% 420 621 20% 12% 223 167 Total room load 2522 5733 1338 1541 Air required (dm) 115,255 61 69 -�- wrightsoft� . .4C..CA Right-Sute®Uriversa1202121.0.10RSU27054 oamerts\WdgtboftWACk4816 Watersorg WaysW Calc= W8 FrortDoorfaces: W 2021-De61012:56:40 Page 5 Air Calcs, LLC Right-JO Worl�aheet AM 9 ;l Air Calcs, LLC 7550 FGdden Hamrmc k Ln, Vero Beads, FL32966 Phone:772.800.8413 Em iil: vidtilyme@aircalcs.com tl Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Hisa w+ 1 Room name A/C 1 Bed 4 1 2 Eposedvall 1 0 ft 26.5 It 3 Room height 9.4 It heaticool 10.0 ft t!.V000l 4 Room dimensions 4.5 x 3.5 It 1.0 x 199.0 It 5 Room area 15.8 IF 199.0 tt2 Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuh/fF-°F) (Stuhffl or perimeter (ft) (Stuh) or perimeter (f) (Btuh) Heat Cool Gross NIPlS Heat Cool Gross NIPS Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 �-G Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 120 120 273 175 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 - 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 2.28 1.46 0 0 0 0 145 89 203 130 Impact 0.780 se 2262 16.82 0 0 0 0 8 8 181 135 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 48 48 933 591 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sv 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 svi 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sv 22.62 2427 0 0 0 0 0 0 0 0 Impact 0.800 sN 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nv 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rnv 30.74 38.6E 0 0 0 0 0 0 0 0 Impact 0.670 r%v 19.43 26.70 0 0 0 0 0 0 0 0 P Fnn Wall. 12" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Atfic, Metal Roof, R 0.386 1.48 1.14 0 0 0 0 0 0 0 0 F 8" ThknsCorxrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F 6' ThknsCorwete Ho 0.049 0.71 0.00 0 0 0 0 199 199 141 0 F On Grade Depth, Tile 0.989 28.68 0.00 0 0 0 0 0 0 0 0 F Part Floor. B Thkns 0.119 3A5 0.00 0 0 1 0 0 0 0 0 6 c) AED exarsion o -67 Envelope loss/gain 1 0 1731 963 12 a) Infiltration 0 0 568 179 b) Room ventilation 0 0 0 0 13 Interned gains: Occupants@ 230 0 0 ' 0 0 Applianoestother 0 1500 Subtotal (lines 6 to 13) 1 0 2299 2642 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1 0 _ 135 147 14 Subtotal 0 0 2434 2789 15 Ductloads 20% 12% 0 0 20% 12% 486 339 Total room load 0 0 2920 312E Airrequired(dm) 0 0 133 139 .�A Riga -Sate® Uriversal 2021 21.0.10 RSU27054 ocmerdslWrightsoftHVAC\4816WatersorgWaynp Calc=MJ8 Frort Door faces: W 2021-Dea1012:56:40 Page 6 Air Calcs, LLC Right-JO Worksiieet A/H 1 Air Calm, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: uckilyme@aircalcs.com ii j Job: 1688 Date: Dec 09, 2021 11 By: Vicki Lynne Nis(1 �I 1 Room name Bath PvdrRm 2 E)posed vall i 10.0 ft 15.5 ft I 3 Room height 10.0 ft heat/000l 10.0 It heattimol 4 Room dimensions 1.0 x 62.3 It 8.0 x 7.5 It 5 Room area 62.3 ft' 60.0 fe Ty Construction on U-value Or HTM Area Load Area Load number (Bhrhf -'F) (Btuh/lt= or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cod Gross NIP/S Heat Cool Gross NiP/S Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 50 42 96 61 75 75 171 109 Impact 0.780 se 22.62 16.82 8 8 181 135 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 9N 2.28 1.46 50 5o 114 73 80 69 158 101 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 21.64 0 0 0 0 11 6 241 231 Impact 0.780 9N 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 24.27 0 0 0 0 0 0 0 0 Impact 0.800 9N 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 ryw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 r%v 19.43 26.70 0 0 0 0 0 0 0 0 P Frrn Wall. 12" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C AmG Metal Roof, R 0.386 1.48 1.14 0 0 0 0 15 15 21 16 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns ConQete Ho 0.049 0.71 '0.00 0 0 0 0 0 0 0 0 F 8" ThknsCorxrete Ho 0.049 0.71 0.00 62 62 44 0 0 0 0 0 F On Grade Depth, Tile 0.989 28.68 0.00 0 - 0 0 0 0 0 0 0 F Part Fkxx, 8"Thkns 0.119 3.45 0.00 0 0 0 0 4 4 14 0 6 c) AED exarsion -21 86 Envelope loss/gain 435 248 605 544 12 a) Infiltration 214 68 332 105 b) Room ventilation 0 0 0 0 13 Internal gains: 'Occupants@ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 649 816 938 649 Less e)demal load 0 0 0 0 Less transfer 0 , 0 0 0 Redistribution 2 0 120 131 14 Subtotal 651 816 1058 779 15 Ductloads 20% 12°/o 130 99 20% 12% 211 95 Total room load 781 915 1 1269 1 874 Air required (dm) 36 41 58 39 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -f}t- wrightsatFC" 2021-Dea1012:56:40 Riga-Sute®Universal 2021 21.0.10 RSU27054 Pagel .-oamerds\WdgfboftWAC43816 WatersorU Way W Calc= MJ8 Frort DoorMoes: W r Air Calm, LLC Right-JO Worksheet AM 1 Air Calks, LLC r 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vidtil@aircalcs.mm Job: 1688 Data: Dec 09, 2021 By- Vicki Lynne Nisa I 1 S Room name ) 2nd Flr Hall 1st Flr Bev 2 Exposed well ( 9.5 It 10.0 ft i 3 Room height 10.0 It heat/cool 10A ft heat/cool I 4 5 Room dimensions Room area 1.0 x 166.0 ft 166.0 It'_ 5.0 x 5.0 ft 25.0 It= Ty Construction U-value Or HTM Area (ft� Load Area (M Load number (BtAft °F) (Btuh or perimeter (ft) (Btuh) or perimeter (IU (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 95 59 135 86 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9,v 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 9H 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 9H 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 2427 36 12 806 865 0 0 0 0 Impact 0.800 9w 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 rw 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 rw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 rw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.050 rw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 26.70 0 0 0 0 0 0 0 0 P Frm Wall. 1 R" Gyp B 0.115 3.33 1.65 0 0 0 0 104 104 346 172 C Attic, Metal Roof. R 0.386 1.48 1.14 5 5 7 5 0 0 0 0 F U' ThknsCorxtety Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8' Thkrts Concrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F U' ThknsCorwete Ho 0.049 0.71 0.00 36 36 26 0 0 0 0 0 F On Grade Depth. Tile 0.989 28.68 0.00 0 0 0 0 25 10 287 0 F Part Floor.8"Thkns 0.119 3.45 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 269 -4 Envelope lossIgain 974 1226 633 168 12 a) Infiltration 204 64 0 0 b) Room ventilation 0 0 0 0 13 Intamalgains: Occupants@ 230 0 0 0 0 Appliance -other 0 0 Subtotal (lines 6 to 13) 1178 1291 633 168 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1178 -1291 -633 -168 14 Subtotal 0 0 0 0 15 Duct loads 20% 12% 0 0 20% 12% 0 0 Total room load 0 0 0 0 Airrequired(dm) 0 0 0 0 -�- wri9FrrtsotFt" . RigaSuite® Universal 2021 21.0.16 RSU27054 .-oamerds\WrigttsoftHVACM816WatersorgWaynp Calc=MJ8 Front Door faces: W 2021-Dek;1012:56.40 Page 8 Air Cans, LLC Right-J® Worksheet A/H 1 Air Calks, LLC a 7550 Hidden Hammock Ln, Vero Bead FL32966 Phone:772.800.8413 Em 'T vickilyme@aircalcs.com a Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Pisa 1 Room name 2nd Fir Elev Cabana 2 3 Exaosedwell Room height 0 ft 10.0 It heaV000l 12.5 It 10A ft h�-at(.I 4 Room dimensions 5.0 x 4.5 ft 1.0 x 123.9 It 5 Room area 22.5 fV 123.9 ft2 Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuhfit2L--F) (Btuhlt� or perimeter (ft) (BWh) or perimeter (11) (Btuh) Heat Cod Gross NIPIS Heat Cool Gross NIPIS Heat Cool 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 2262 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 s+v 2.28 1.46 0 0 0 0 130 130 296 189 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 sv 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sv 22.62 24.27 0 0 0 0 0 0 0 0 Impact 0.800 sry 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 rnv 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 rnv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 rnv 19A3 17.56 0 0 0 0 0 0 0 0 Impact 1.060 rhv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 nw 19A3 26.70 0 0 0 0 0 0 0 0 P Fnn Wall. 1,7 Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Attic, Metal Roof. R 0.386 1.48 1.14 0 0 0 0 19 19 28 21 F 8' Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F U' Thkns Concrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 0.71 0.00 5 5 3 0 0 0 0 0 F On Grade Depth, Tile 0.989 28.68 0.00 0 0 0 0 124 13 359 0 F PartFloor.8 Thkns 0.119 3.45 0.00 0 0 0 0 0 0 0 0 s c) AED exarsion 0 -7 Envelope losslgain 3 0 682 203 12 a) Infiltration 0 0 279 88 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianoesrother 0 0 Subtotal (lines 6 to 13) 3 0 961 291 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -3 0 336 89 14 Subtotal 0 0 1297 380 15 Duct loads 20% 12% 0 0 20% 12% 259 46 Total room load 0 0 1556 426 Air required (dm) 0 0 71 19 wr➢gF��tsotFt� ' Right -Suite® Universal 2021 21.0.10 RSU27054 .-oamerds\WrightsoftHMACk816WatersorgWaynp Calc=MJ8 Front Door faces: W 2021-Dea1012:56:40 Page 9 Air Calks, LLC Right-JO Worksfieet AN 1 Air Calks, LLC 7550 Hidden Hammock Ln, Vero Beads, FL32966 Phone: 772.800.8413 Email: j,,MIyme@aircalcs.com u Job: 1688 Date: Dec 09, 2021 } By: Vicki Lynne Nis�a 1 Room name Stairs2ndFir i 1stFlrStairs 2 Exposed mall 13.0 It 11.0 It 3 Room height 10.0 It heall000l 10A It heaftol 4 5 Room dimensions Room area 13.0 x 6.5 It 84.5 ft2 11.0 x 8.5 It 93.5 ft Ty Construction number U-value (Btuhfit`�-q Or HTM (Btuh/ft-) Area or perimeter (ft) Load (Btuh) Area or perimeter (tt) Load (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 Block R-9 Wall 0.079 n 2.28 1.46 0 0 0 0 0 0 0 0 Impact 1.060 n 30.74 18.99 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 23.20 23.59 0 0 0 0 0 0 0 0 Impact 0.800 ne 2320 23.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.790 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 13.06 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 9N 2.28 1.46 130 130 296 189 114 114 260 167 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 21.79 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.57 0 0 0 0 0 0 0 0 Impact 0.780 sv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 24.27 0 0 0 0 0 0 0 0 Impact 0.800 9N 23.20 15.95 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 17.56 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 r1w 30.74 38.88 0 0 0 0 0 0 0 0 Impact 0.670 nw 19.43 26.70 0 0 0 0 0 0 0 0 P Frm Wall. 12" Gyp B 0.115 3.33 1.65 0 0 0 0 0 0 0 0 C Attic, Metal Roof, R 0.386 1.48 1.14 7 7 10 7 17 17 24 19 F 8" Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 - 0.71 0.00 0 0 0 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.71 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 - 28.68 0.00 0 0 0 0 94 11 315 0 F Part Floor.8"Thkns 0.119 - 3A5 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -7 -6 Envelope loss/gaim 306 190 600 179 12 a) Infiltration 279 88 245 77 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancesrottler 0 0 Subtotal (lines 6 to 13) 584 278 846 256 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -584 -278 -846 -256 14 Subtotal 0 0 0 0 151 Ductloads 120% 129/6 0 0 20% 121/6 0 0 Total room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -�- wrigF�tsoft�' 2021-Deo•1012:56:40 Right -Suite@ Universal 2021 21.0.10 RSU27054 Page 10 -oameNs\WrightsoftHVAGW816WatersorgWaynp Calc=MJ8 Front Door faces: W i Air Calcs, LLC Right-JO or s e---t A/H 2 i Air Calm, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vickilyr a@aircalcs.com Job: 1688 Date: Dec 09, 2021 By. Vicki Lynne Nisa 1 Room name j AAi 2 Master Bedroom 2 FVosed well 193.0 ft 36.0 ft 3 Room height 10.0 It d 12.0 ft heat/ocol 4 Room dimensions 1.0 x 390.9 It 5 Room area 1689.5 1t' 390.9 ft2 Ty Construction U-value Or HTM Area (ftF) Load Area Load number (BWhAtz°F) (BtuhAt2) or perimeter (ty (BWh) or perimeter (ft) (Btuh) Heat Cod Gross NIPIS Heat Cool Gross NIPS Heat Cod 6 Block R-9 Wall 0.079 n 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 n 0.00 0.00 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 713 663 1510 966 252 232 528 338 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 8 0 181 220 0 0 0 0 Impact 0.780 ne 22.62 27.52 20 0 452 550 20 0 452 550 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 21 0 483 587 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 249 165 376 240 0 0 0 0 Impact 0.780 se 22.62 16.82 16 16 362 269 0 0 0 0 Impact 0.780 se 22.62 22.89 20 9 452 458 0 0 0 0 Impact 0.670 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19.43 12.30 48 48 933 591 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 658 630 1435 918 0 0 0 0 Impact 0.780 9N 22.62 21.64 8 5 181 173 0 0 0 0 Impact 0.780 9H 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.0C 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.89 20 9 452 458 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 sw 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 288 164 373 239 180 100 228 146 Impact 0.780 rw 22.62 29.09 44 0 999 1285 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rrnr 30.74 38.88 80 0 2459 3110 80 0 2459 3110 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 rrw 0.00 0.00 0 0 0 0 0 0 0 0 P Frm Wall.12" Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic, Metal Roof. R 0.386 1 A8 1.14 1690 1690 2504 1920 391 391 579 444 F 8"ThknsConcrete Ho 0.049 1A2 0.00 107 107 152 0 15 15 21 0 F 8" Thkns Concrete Ho 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThknsCorwete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor.8"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exarsion 930 573 Envelope losslgain 13305 12914 4268 5162 12 a) Infiltration 4092 1290 927 292 b) Room ventilation 0 0 0 0 13 InWmalgains: Occupants@ 230 0 0 0 0 Appliances/other 6250 1500 Subtotal (lines 6 to 13) 17397 20454 5195 6954 Less exWmalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 40 30 14 Subtotal 17397 20454 5235 6983 15 Ductloads 121% 120/6 3643 2434 21% 12% 1096 831 Total room load 21040 22888 6331 7815 Air required (cfm) 1140 1140 343 389 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. AW 2021-Deo-1012:56:40 RigWSute®Uriversal2021 21.0.10 RSU27054 Page 11 .-oameNs\WrigttsoftWAC14816 Watersorg Waynp Calc= W8 Front Door faces: W 4 a n v, N Air Calcs, LLC Right-JO Worksheets AM 2 Air Calks, LLC .a 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicldlyn a aircalcs.com Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name S y M Hall Hers 2 3 E)posed wall Room height 0 It I 9A it heat(cool 14.0 It 9.4 It heattocol i 4 5 Room dimensions Room area 1.0 x 36A ft 36.4 IF 1.0 x 92.8 It 92.8 IF I Ty Construction U-value Or HTM Area (ft) Load Area (q Load number (BUK42-9 (Btuh/M or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross NIPIS Heat Cool Gross NrPIS Heat Cool 6 Block R-9 Wall Impact 0.079 1.060 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact Impact 0.800 0.800 0.800 ne ne ne 0.00 000 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Block R-9 Wall Impact 0.079 0.780 se se 228 2262 1.46 16.82 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact Impact 0.670 0.670 se se 0.00 19.43 0.00 12.30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 132 132 300 192 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.8W sv 000 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 22.62 29.09 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact 1.060 1.060 nw nw 30.74 0.00 38.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact Fnn Wall. 1 Z Gyp B 0.670 0.115 nw 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P C Attic, Wtal Roof. R 0.386 1.48 1.14 36 36 54 41 93 93 137 105 F 8" ThknsConcrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F U' ThknsCowete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8r' Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Fim.B Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exa>rsion 1 -8 Envelopeloss/gain 54 41 437 289 12 a) Infiltration 0 0 282 89 b) Roomventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Appliances(other 0 0 Subtotal (lines6 to 13) 54 41 719 378 Less e)demal load 0 0 0 0 Less tansfer 0 0 0 0 Redistribution -54 -41 14 11 14 Subtotal 0 0 733 389 151 Duct loads 21% 12% 0 0 21% 12% 154 46 Total room load 0 0 887 AMAirrequired(dm) 0 0 48 22 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. "'� wrflgF�tsoTtd . . .4CCA Rtgtt-Suite® Universal 2021 21.0.10 RSU27054 -ownents\Wdgttsoff WACX4816 Watersorg Waynp Cato =MJ8 Front Door faces: W 2021-Dec-1012:56:40 Page 12 1 ii Air Calcs, LLC Right-J® Work41eet A/H 2 Air Calks, LLC 7550 Hidden Hammock LR Vero Beach, FL32966 Phone: 772.800.8413 Email: vic-lyme@aircalcs corn Vi Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisal s 1 Room name j Master Bath W r Clst 2 3 6gwsed Hell Room height 35.0 ft 9A It heat/000l 4.5 ft 9A ft heaticiol 4 5 Room dimensions Room area 1.0 x 163.3 It 163.3 IF 4.5 x 5.5 ft 24.8 it= Ty Construction U-value Or HTM Area (Il) Load Area Load number (Btuhf F,--q (Btuhlt� or perimeter (ft) (Btuh) or perimeter (f) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall Impact 0.079 1.060 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 75 75 171 110 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact Impact 0.780 0.780 ne ne 22.62 0.00 27.52 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact 0.800 0.800 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.670 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 146 146 332 212 42 34 78 50 Impact 0.780 sn 22.62 21.64 0 0 0 0 8 5 181 173 Impact 0.780 sv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 srr 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sN 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.780 9H 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 sw 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 108 64 146 93 0 0 0 0 Impact 0.780 nw 2262 29.09 44 0 999 1285 0 0 0 0 Impart 0.670 rev 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rwv 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Frm Wall. 12" Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C AIM Metal Rod. R 0.386 1.48 1.14 163 163 242 186 25 25 37 28 F 8" ThknsConcrete Ho 0.049 1.42 0.00 92 92 131 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThknsCorxrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F-' On Grade Depth. Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor. 8"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 490 70 Envelopeloss(gain 2020 2375 296 321 12 a) Infiltration 706 222 91 29 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/o1w 5W 0 Subtotal (lines 6 to 13) 2726 3098 386 350 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 6 9 7 14 Subtotal 2734 3104 396 357 15 DuctloadS 121% 12% 5731 369 21% 12°/a 83142 Total room load 3307 3473 479 399 Air required (dm) 179 173 26 20 a Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -F}i- wrigFstsolFt� 2021-Dec-1012:56:40 . �CCA "'" - " ` Right SUte® Universal 2021 21.0.10 RSU27054 Page 13 oamerds\Wdghtsoft WAC14816 Watersorg Waynp Calc= MJ8 Front Door faces: W i A3, 1 Air Calcs, LLC Right-M Worksheat A/H 2 Air Calks, LLC 7550 Hidden Hammock Lrt Vero Beads. FL32966 Phone: 772.800.8413 Email: viddinne@aircalcs.com Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa y r} 1 Room name { 3rd RrStairs ti Loft j 2 E)posed wall i 13.5 It 23.0 It 3 Room height 9.4 It heaU000l 9.4 It heaUcool 4 5 Room dimensions Room area 13.5 x 7.0 It 94.5 ftz 16.0 x 7.0 ft 112.0 ft2 Ty Construction U-value Or HTM Area (M Load Area (ft) Load number (BtuhR-'F) (Btuh/n or perimeter (ft) (Btuh) or perimeter (t) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 Block R-9 Wall Impact Black R-9 Wall 0.079 1.060 0.079 n n ne 0.00 0.00 2.28 0.00 0.00 1.46 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 66 46 104 67 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 20 9 452 458 Impact 0.670 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 127 127 289 185 150 130 297 190 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.89 0 0 0 0 20 9 452 458 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 sw 000 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nrw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 2262 .29.09 0 0 0 0 0 0 0 0 Impact 0.670 rw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rnv 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 n w 0.00 0.00 0 0 0 0 0 0 0 0 P Fnn Wall.1 Z Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic, Metal Roof. R 0.386 1.48 1.14 -95 95 140 107 112 112 166 127 F U' Thkns Concrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F 8"ThknsCorxreteHo 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8"ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor.8"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exeusion -12 -58 Envelopeloss/gain 429 280 1472 1241 12 a) Infiltration 272 86 464 146 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 250 1500 Subtotal (lines 6 to 13) 701 616 1936 2888 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 52 39 38 28 14 Subtotal 754 655 1973 2916 15 Ductloads 121%1 129/6 158 78 21% 12% 413 347 Total room load 911 733 2387 3263 Airrequired(dm) 491 37 129 163 s t � . Calculations approved WACCAto meet all requirements of Manual J 8th Ed. -�- wrYghtso4Tt� ' AC�A Right-Suite(S) Universal 2021 21.0.10 RSU27054 oemerds\WrighlsoftWACV4816WatersorgWaynp Calc=W8 Front Door faces: W 2021-Dec-1012:56:40 Page 14 4 Air Calcs, LLC Right-J® Worksheets A/H 2 Air Calm, LLC ;i 7550 Hidden Hammock Ln, Vero Beac4 FL32966 Phone: 772.800.8413 Email: vlckjlymeCaircalcs.com Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name V Bath 3 Bed 3 2 3 Exposed wall Room height 120 It 9A It heat/cool 26.5 ft i 9A It heat/000l 4 Room dimensions 12.5 x 5.5 ft 12.5 x 14.0 It 5 Room area 68.8 1F 175.0 ft2 Ty Construction U-value Or HTM Area (F) Load Area (ftF) Load number (Btuh/IF-°F) (B or perimeter ((t) (Btuh) or perimeter (tl) (BWh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall 0.079 n 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 n 0.00 0.00 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 117 117 268 171 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact _ 0.780 ne 0:00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne --_..0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 2.28 1.46 52 44 100 64 132 76 172 110 Impact 0.780 se 22.62 16.82 8 8 181 135 8 8 181 135 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.670 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 48 48 933 591 Block R-9 Wall 0.079 sw 2.28 1.46 61 61 139 89 0 0 0 0 Impact 0.780 sw 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sv 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 sry 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 22.62 29.09 0 0 0 0 0 0 -0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rrw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Fmn Wall.12" Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic, Wtal Roof. R 0.386 1.48 1.14 69 69 102 78 175 175 259 199 F 8' ThknsCorxrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F 8" Thkris Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor. B"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exausion -19 -47 'Envelopelossrgain 522 347 1813 1158 12 a) Infiltration 242 76 534 168 b) Roomventilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 0 0 Appliancesrother 500 1000 Subtotal (lines 6 to 13) 763 923 2347 2327 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 20 15 22 16 14 Subtotal 784 938 2369 2343 15 Ductloads 21% 12% 164 112 21% 12% 4961279 Total room load 948 1050 2865 2622 Air required (dim) 51 52 155 131 -w Ild wrigl �tsoit- ' . . 2021-Dea1012:56:40 "" "" ""'" "' Right -Suite® Universal 2021 21.0.10 RS027054 Page 15 .oamertsUrightsoftWAC14816WatersorgWaynQ CaIc=MJB FrortDoorfaces: W Air Calcs, LLC Right-M Worksheet AM 2 Air Calcs, LLC 1 ;a 7550 Hidden Hammock Ln, Vero Beads, FL32966 Phone:772.800.8413 Email: vidtilyme@aira3lcs.com Job: 1688 Data: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name WIC 3 - A/C 2 2 3 Exposed wall Room height 5.0 It ; 9A ft heall000l 0 It 9A It heaf/000l 4 5 Room dimensions Room area 5.0 x 7.0 It 35.0 ft' 5.0 x 3.0 ft 15.0 IF Ty Construction U-value Or HTM Area (fil Load Area (ft� Load number (BhihAf-°F) (Btuh/fl or perimeter (tt) (Btuh) or perimeter (11) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross NIPS Heat Cool 6 T_GBlock R-9 Wall Impact 0.079 1.060 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 47 47 107 68 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 _ 0 0 0 0 0 0 0 0 Impact 0.800 ne 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact Impact 0.670 0.670 se se 0.00 19.43 0.00 12.30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Block R-9 Wall Impact Impact 0.079 0.780 0.780 sN sN sw 2.28 22.62 0.00 1.46 21.64 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.780 sN 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact 0.780 0.780 sin sw 22.62 000 22.89 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.800 sw 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 nw 22.62 29.09 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 nw 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Impact Fnn Wall. 12" Gyp B 0.670 0.115 nw 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C Attic. Metal Roof. R 0.386 1.48 1.14 35 35 52 40 15 15 22 17 F 8" Thkns Concrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F 8"ThkrsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThkrsCorKrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Roor.8 Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exarsion -3 0 Envelope losslgain 159 105 22 17 12 a) Infiltration 101 32 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Ocarpants@' 230 0 0 0 0 Appliarmstother 0 0 Subtotal (lines 6 to 13) 260 137 22 17 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 10 8 -22 -17 14 Subtotal 270 145 0 0 15 Ductloads 21% 12% 57 17 21% 12% 0 0 Total room load 326 162 0 0 Air required (clm) 18 8 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �- wrYgFitsoR� 2021-Deo-1012:56:40 ACACk Right SriteO Uriversal 2021 21.0.10 RSU27054 Page 16 oamerds\WrigHsoftFNAC14616WatersorgWaynp Calc=MJ8 Front Door faces: W Air Calcs, LLC Right-JO Wo AM 2 -Air Cales, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name i Bath 2 Bed 2 2 3 Exposed well Room height 5.5 ft - 6 9A ft heat/cool 12.5 It 9A ft heat1cool t 4 Room dimensions 5.5 x 10.0 ft 12.5 x 15.0 ft 5 Room area 55.0 ft' 187.5 ft2 Ty Construction U-value Or HTM Area Load Area (ft) Load number (Btuhd-°F) (BtuhAt� or perimeter (ft) (Btuh) or perimeter (ty (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 Block R-9 Wall 0.079 n 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 n 0.00 0.00 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.079 ne 2.28 1.46 52 44 100 64 117 96 219 140 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 8 0 181 220 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impart 0.780 ne 22.62 27.52 0 0 0 0 21 0 483 587 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.670 se 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 se 19A3 12.30 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 sv 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 sw 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impart 0.780 nw 2262 29.09 0 0 0 0 0 0 0 0 Impact 0.670 rw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 r%v 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Frm Wall. 12' Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic, Metal Rod. R 0.386 1.48 1.14 55 55 82 63 188 188 278 213 F 8" ThknsConcrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F U' ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 8' Thkns Corwete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor. S'Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED exausion -8 -40 Envelope loWgain 362 339 979 900 12 a) Infiltration 111 35 252 79 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Applianoes(other 0 1000 Subtotal (lines 6 to 13) 473 374 1231 1980 Less e)demal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 27 21 68 51 14 Subtotal 500 394 1299 2031 15 Ductloads 21% 12% 105 47 21% 12% 272 242 Total room load 605 441 1571 2272 Air required (dm) 33 22 85 113 ( Calculations approved byACCikto meet all requirements of Manual-J 8th Ed. -F�- wrGgtitsolFE� 2021-Dec-1012:5640 . rt s" ""`"- " "^ Right -Suite® Universal 2021 21.0.10 RSU27054 Page 17 .-oamerds\Wrigh1wftWACIA816WatersorgWayrLp Calc=MJ8 Front Door faces: W t i Air Calcs, LLC Right-JO Worksheets AM 2 ' Air Calks, LLC 7550 Hidden Hammack Ln, Vero Beady FL32966 Phone: 772.800.8413 Email: vicldlym @ 3ircalcs.com Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name d WIC 2 His 2 3 Exposed wall Room height 5.5 ft E 9A It heat/000l 0 It 9A It heat/mol 4 5 Room dimensions Room area 5.5 x 4.5 It 24.8 1P 1.0 x 55.8 ft 55.8 IF Ty Construction U-value Or HTM Area (Its Load Area (n Load number (Btulvft;°F) (Btu or perimeter (Btuh) or perimeter (ty (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 lQJ �G Block R-9 Wall Impact Block R-9 Wall 0.079 1.060 0.079 n n ne 0.00 0.00 2.28 0.00 0.00 1.46 0 0 52 0 0 52 0 0 118 0 0 75 0 0 0 0 0 0 0 0 0 0 0 0 W 11 Impact Impact 0.780 0.780 ne ne 0.00 22.62 0.00 27.52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact Impact 0.780 0.780 ne ne 22.62 0.00 27.52 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0,800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impart 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 se 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 se 2262 16.82 0 0 0 0 0 0 0 0 Impact 0.780 se 22.62 22.89 0 0 0 0 0 0 0 0 Impact Impact 0.670 0.670 se se 0.00 19A3 0.00 12.30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blodk R-9 Wall Impact 0.079 0.780 9N sw 2.28 22.62 1.46 21.64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.780 9H 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9H 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9+v 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact 0.780 0.780 9H 9N 22.62 0.00 22.89 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.800 sw 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall Impact 0.079 0.780 rw nw 228 22.62 1.46 29.09 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact Impact 1.060 1.060 nw nw 30.74 0.00 38.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.670 nrw 0.00 0.00 0 0 0 0 0 0 0 0 P Fnn Wall. 12" Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic. Metal Rod. R 0.386 1.48 1.14 25 25 37 28 56 56 83 63 F 6'ThknsConcrete Ho 0.049 1A2 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 8" ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth. Tile 0.989 - 0.00 0.00 0 0 0 0 0 0 0 0 F Part Fkxx.B"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED e)=rsion -3 -1 Envelopeloss/gain 154 101 83 62 12 a) Infiltration 111 35 0 0 b) Roomventilation 0 0 0 0 13 Interned gains: Occupants@ 230 0 0 0 0 Appliancesdother 0 0 Subtotal (lines 6 to 13) 265 136 83 62 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 2 1 14 Subtotal 265 136 85 64 15 Ductloads 1 21% 12% 56 16 21% irlol 18 8 Total room load 321 152 102 71 Air required (dm) 17 8 6 4 S t' ACCA b meet all -FW 2021-Dec-1012:56:40 """ "" ' "' Right -Skit-® Universal 2021 21.0.10 RSU27054 Page 18 .-oc meNs\WrigHsoitHMAC14816 Watersong Wayr p Calc= MJ8 FrortDoor faoes: W :y U j Air Calcs, PLC Right-J® Worksheet A/H 2 .i Air Calks, LLC y a) 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Email: v dkilymeQairlcs.com Job: 1688 Date: Dec 09, 2021 By: Vicki Lynne Nisa 1 Room name 3rd Fir Elev 3rd Rr Hall 2 3 Egosedvell Room height 0-ft f 9A It heaftol 0 ft 9;4 ft -- heat/cool 4 Room dimensions 5.5 x 4.5 It 1.0 x 133.5 ft 5 Room area 24.8 fY 133.5 ft2 Ty Construction U-value Or HTM Area (ft0 Load Area Load number (Btuh/ft;°n (B or perimeter (11) (Bhnh) or perimeter (tt) (Btuh) Heat Cod Gross NnPIS Heat Cool Gross NIPIS Heat Cool 6 %VBlock R-9 Wall 0.079 n 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 n 0.00 0.00 0 0 0 0 0 0 0 0 -1 W Block R-9 Wall 0.079 ne 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 22.62 27.52 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.800 ne 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall Impact 0.079 0.780 se se 228 22.62 1.46 16.82 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact 0.780 -se 22.62 22.89 0 0 0 0 0 0 0 0 Impact Impact 0.670 0.670 se se 0.00 19.43 0.00 12.30 0 0 0 0 0 0 0 0 0 0 0 ll 0 0 0 0 Block R-9 Wall 0.079 sw 2.28 1.46 0 0 0 0 0 0 0 0 Impact 0.780 9N 22.62 21.64 0 0 0 0 0 0 0 0 Impact 0.780 s+v 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9N 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 sw 0 00 0.00 0 0 0 0 0 0 0 0 Impact 0.780 9.v 22.62 22.89 0 0 0 0 0 0 0 0 Impact 0.780 sw 000 0.00 0 0 0 0 0 0 0 0 Impact 0.800 9N 0.00 0.00 0 0 0 0 0 0 0 0 Block R-9 Wall 0.079 nw 228 1.46 0 0 0 0 0 0 0 0 Impact 0.780 rw 22.62 29.09 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 Impact 1.060 rnv 30.74 38.88 0 0 0 0 0 0 0 0 Impact 1.060 r%v 0.00 0.00 0 0 0 0 0 0 0 0 Impact 0.670 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Fnn Wall.10 Gyp B 0.115 0.00 0.00 0 0 0 0 0 0 0 0 C Attic, Metal Roof. R 0.386 1.48 1.14 25 25 37 28 134 134 198 152 F 8" Thkns Concrete Ho 0.049 1.42 0.00 0 0 0 0 0 0 0 0 F 8" Thkns Concrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F 6"ThknsConcrete Ho 0.049 0.00 0.00 0 0 0 0 0 0 0 0 F On Grade Depth, Tile 0.989 - 0.00 0.00 0 0 0 0 0 0 0 0 F Part Floor.6"Thkns 0.119 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -3 Envelope lossIgain 37 28 198 149 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@' 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 37 28 198 149 Less Wemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -37 -28 -198 -149 14 Subtotal 0 0 0 0 15 Dudloads 21% 12% 0 0 21% 12% 0 0 Total room load 0 0 0 0 Airrequired(dm) 0 0 0 0 r 1 i Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -of*wrigF�tsc'vz- 2021-Dec-1012:56:40 A '" "' "" Right -Sate® Universal 2021 21.0.10 RSU27054 Page 19 oaments\WrightsoftWAC41816WatersongWaynp Calc=MJ8 Front Door faces: W �t Duct System Summary Air Calcs, LLC Y A/H 1 Air Calm, LLC y 7550 Hidden Hammock LR Vero Beads, FL32966 Phone: 772.800.8413 Email: viddlynne@airca For: MarioArbucci, Coastal Construction and Design, Inc . 4816 Watersong Way, Hutchinson Island, FL 34949 Job: 1688 Date: Dec 09, 2021 _ By. Vicki Lynne Nisa Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.70 in H2O 0.70 in H2O Supply / return available pressure 0.350 / 0.350 in H2O 0.350 / 0.350 in H2O Lowest friction rate 0.207 in/100ft 0.207 in/100ft Actual air flow 1900 cfm 1900 Cfm Total effective length (TEL) 338 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 1 st Rr La"ry-A h 2127 117 99 0.287 6.0 Ox 0 VIFX 64.1 180.0 st10 2nd Ar Landry C 1541 73 82 0.384 5.0 Ox 0 VIFx 27.3 155.0 SO 1 Bath C 915 43 49 0.399 4.0 Ox0 VIFx 15.5 160.0 sti1 Bea 4 c 3128 160 167 0.438 7.0 Ox 0 VIFx_ _ 20.0 140.0 st11 Cabana h 1556 85 23 0.270 6.0 Ox 0 VIFx 59.6 200.0 st10 Dining Room h 2480 136 132 0.207 7.0 Ox 0 VIFx 57.5 280.0 SO 5 Dirirg ROOrtrA h 2480 136 132 0.243 7.0 Ox 0 VIFX 42.5 245.0 St14 Flex Space h 3497 192 153 0.249 8.0 Ox 0 VIFx 66.6 215.0 st10 Flex Space -A h 3497 192 153 0.284 7.0 Ox 0 VI Fx 56.1 190.0 SO 0 Foyer h 3198 175 79 0.272 7.0 Ox 0 VIFx 32.1 225.0 st9 Foyer -A h 3198 175 79 0.366 7.0 Ox 0 VIFx 26.1 165.0 st6 latd,en c 2866 69 153 0.309 7.0 Ox 0 VIFx 26.5 200.0 St13 Kitchen -A c 2866 69 153 0.299 7.0 Ox0 VIFx 34.0 200.0 st13 Ocean Roora-A c 7157 262 382 0.208 10.0 OX 0 VIFX 57.0 280.0 St15 Ocean Roorn-C c 7157 262 382 0.243 10.0 OX 0 VI Fx 42.5 245.0 St14 Pwdr Rm h 1269 70 47 0.478 5.0 Ox 0 VIFx 6.5 140.0 st2 Storage h 1202 1 66 18 1 0.270 5.0 OX 0 1 VIFx 1 44.6 1 215.0 1 St10. .�. * wrightsoft® ^'�- RighlSdte@Universal 202121.0.10RSU27054 Yi+Ch ..:oainer6%Wridfi oft HVAN816Wiiirs6ig Wayne Calk="MJ8 'FrartDo6tfacei W '1 2021-Dec-1012:56:44 1, Page 1 i (Z U 3 CD in O CD O Na. OOO 7 (D (7)OoW O W V 00 O O O M. 7 O O O 3 O O O fu " 3 000 000 = x x x x 000 7 L (3 O sss �o x x x X d C G .� 2 7 7(• �OOOFS�I� W R� NCnA W � (D T � T T T T T T T T VV. V V V V V V V i1I ; (U N N CU N iU D1 2 CD N ;R m � J 4CO 2 R(O O WOWO O�(D CD WN O NCn NN O�W W(D CO W A 4 W W O --� W W (Jo (n W W W O Cn Cn Cn O (A)W f.T7 O CA) O N N N O, W W— N W? CO NACnAANWwAaoWAoo 0000000000000 -nN NIVfNNINININNNNNWLJ V -4-4v V-NA �� =3 (AD CDD(AO(AD(AO(AO' �. M �(.nw-4-CnooW v W wm0, 3 O Cn rnJJJJ�►'J JJJJJJ r�ivrv►�rv:r�r�ivNtvrvN =•!y "3 00000cl0000000 4.ftftftfto -t CD (30h.ft ftoo x x x x x x x x x x x x x �2 x O J J J J J J J J J J J J N N N N N N N N N N N N (n (n (n (n cn (n (n (n cn (n (n (n TI ���� S S� S S S S S •�• � CD N CD (D fD CD fD (D CD CD (D CD (D M (D (D M CD (D C �• CD �• N N N N �� ->• -� N C .Ni • J�2 Air Calcs, LLC Duct System Summary, Date: D cg09, 2021 A/H 2 Y By. Vicki Lynne Nisa r h Air Calks, LLC T f• i � J 7550 Hidden Hammock LR Vero Beads, FL32966 Phone: 772.800.8413 Email: viddlyrm@airc�)cs.com i For: ManoArbucci, Coastal Construction and Design, Inc 4816 Watersong Way, Hutchinson Island, FL 34949 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.70 in H2O 0 in H2O 0.70 in H2O 0.499 / 0.201 in H2O 0.237 in/100ft 1140 dm RM Cooling 0.70 in H2O 0 in H2O 0.70 in H2O 0.499 / 0.201 in H2O 0.237 in/100ft 1140 cfm Name Design (Btuh) Htg (cfm) Clg (ctm) Design FIR Diam (in) H x W (in) Duct Mats Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 3rd Flr Stairs h 911 59 44 0.237 5.0 Ox 0 VIFx 25.5 185.0 st5 Bath h 605 39 26 0.271 4.0 Ox0 VIFx 9.0 175.0 St5- Bath 3 c 1050 62 63 0.323 5.0 Ox0 VIFx 14.5 140.0 st4 Bed 2 c 2272 102 136 0.269 7.0 Ox 0 MFx 10.5 175.0 st5 Bed 3 h 2865 186 157 0.346 7.0 Ox 0 VIFx 14.0 130.0 st4 Hers h 887 58 26 0.254 5.0 Ox 0 VIFx 41.5 155.0 st16 His h 102 7 4 0.251 4.0 Ox 0 VIFx 28.5 170.0 st5 Loft c 3263 155 195 0.299 7.0 Ox 0 VIFx 17.0 150.0 st4 Master Bath h 3307 215 208 0.252 8.0 Ox0 VIFx 58.0 140.0 st16 Master Bedroom c 3907 206 234 0.272 8.0 Ox0 VIFx 43.0 140.0 SO Master Bedroom -A c 3907 206 234 0.258 8.0 Ox 0 VIFx 28.5 165.0 st16 WIC 2 h 321 21 9 0.241 4.0 Ox 0 VI Fx 26.5 180.0 st5 WIC h 326 21 10 0.280 4.0 Ox0 VIFx 13.0 165.0 st4 Wtr Clst h 479 31 24 0.256 4.0 Ox 0 VtFx 49.5 145.0 st16 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfni) (cim) ' - FIR (fprrl) (In) (in) Material Trunk st16 PeakAVF 715 - 725 - --0.252- 745 ZO 10 x 14 RectFbg st5 st5 PeakAVF 944 944 0.237 755 2.0 10 x 18 RectFbg st4 PeakAVF -424 �� •-424 0:280 636 - -2.0 8 x 12 RectFbg Boldrrtal/c values have been manually overridden wrightsoftm { 2021-17eo-1012:56:44 Y . Nght-Sute® Universal 2021 21.0.10 RSU27054 i Page 3 ._damerds\Wribh&ft VACk816WatersorgWdi4 CaIc=MJB Front65orf4i5eW Grille Htg Clg TEL Design Veoc Diam H x W Stud/Joist Duct Name Size (in) (Cfm) (Cfm) (ft) FR (fpn) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 476 497 85.0 0.237 .465 14.0 Ox 0 VIFx rt1 rb5 Ox 0 123 145 66.3 0.304 ' 542 7.0 Ox 0 VIFx rt1 rb1 Ox0 207 166 67.5 0.298 594 8.0 0x 0 MFx rt1 rb6 Ox 0 562 559 82.5 0.244 525 14.0 Ox 0 RtFg rt1 Name Trunk Type Htg (Cfm) Clg (Cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Dud Material Trunk rt1 PeakAVF 1368 1368 0.237 821 2.0 12 x 20 RectFbg Boldrrfalk values have been manually overridden 2021-Deo-1012:56:44 wright50Tt® Rgk-Sate® Liriversal.2021 21.0.10 RSU27054 # Page 4 ...00merds%WrigUsoftWAC43816WatersorUWaynp CaIc=W8 FrortDoorfaces: W