HomeMy WebLinkAboutCARPORT DRAWINGS - 4 EL GRECOCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISION12SHEET NO:34PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
FLORIDA ALUMINUM
ENGINEERING, INC.
L
I
CENSET
H
OMASP.ARNETTPROFESSIONALENGI
N
E
ERFLORIDA This item has beenelectronically signed and sealedby T.P. Arnett, PE. using aDigital Signature with date andtime. Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified onany electronic copies.5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA BUSINESS REGISTRY LICENSE NO. 32807 CONTRACTOR: WYNNE BUILDING CORPDESIGN CRITERIA:WIND SPEED AND EXPOSURE HAVEBEEN DETERMINED USING THE ADVANCEDTECHNOLOGY COUNCIL'S WEBSITEAND GOOGLE EARTH.Applicable Codes, Regulations, and Standards1.The 7th Edition (2020) Florida Building Code, specifically Chapter16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood.2.AA ASM 35 and AA ADM1 Specifications for AluminumStructures, Part 1-A of the Aluminum Design Manual prepared byThe Aluminum Association. and the AAF Guide to AluminumConstruction in High Wind Areas.3.ASCE 7-16.Loading Criteria1.Live Load: 10 PSF per 7th Edition (2020) Florida Building Code,Appendix I Section 105.12.Dead Load: 1 PSF3.Wind Load:3.1.Building Occupancy Category, Section 1604.5 and Table1604.5: Risk Category 1.3.2.Ultimate Design Wind Speed: VULT = 150 MPH, NominalDesign Wind Speed: VASD = 116 MPH3.3.Exposure Category, Section 1609.4.3: Exposure B3.4.Screen Enclosure Section 2002.44.Building Category for Aluminum Structures, Section 2002.6:Category Type 1 - Patio Cover: Non-Habitable, UnconditionedRoof Type1.Roof Type: GABLE2.Roof Material: 3” x 12” 0.030” Town & Country Industries RiserPanel, Florida Product Approval Number FL 17638-R2Foundation DesignExisting concrete slab. No additional concrete footing or slab isrequired to resist the loads imposed upon the existing slab by theproposed construction if the existing slab is a minimum of 4” thickand in sound condition, free from structural cracking, spalling, orother deterioration.SpecificationsThe following specifications are applicable to this project:1.All work shall be in accordance with the 7th Edition (2020) FloridaBuilding Code, and any other applicable local codes and regulations.2.Aluminum extrusions shall be 6005 T5 Alloy. Due to quality controlissues, no manufacturer substitution is acceptable without thespecific written, signed and sealed authorization of FloridaAluminum Engineering, Inc.3.Fasteners are required to be corrosion resistant, minimum SAEGrade 2 or better zinc plated to ASTM B633, or coated stainless steelseries "300", or uncoated stainless steel series "400".4.Approved concrete screw anchors to be Simpson Titen-HD orequivalent.5.All Self Mating Beam Sections are to be stitched with either #14screws 6” from ends and 24” center to center or #12 screws 6" fromends and 12" center to center.6.Where concrete specifications are required, whether in the screenenclosure scope or not, by one or more regulatory agency, thefollowing specifications are applicable:a.Concrete shall conform to ASTM C94 for the followingcomponents:i.Portland Cement Type 1,- ASTM C 150ii.Aggregates - Large Aggregate 3/4” max - ASTM C 33iii.Air entraining +/- 1% - ASTM C 260iv.Water reducing agent - ASTM C 494v.Clean Potable watervi.Other admixtures not permittedb.Metal accessories shall conform to:i.Reinforcing Bars - ASTM A615, grade 60ii.Welded wire fabric - ASTM A185c.Concrete slump at discharge chute not less than 3” or morethan 5”. Water added after batching is not permitted.d.Prepare and place concrete per American Concrete InstituteManual of Standard Practice, Parts 1, 2, and 3 including hotweather recommendations.e.Moist cure or polyethylene curing permitted.f.Prior to placing concrete, treat the entire subsurface area fortermites in compliance with the FBC.g.Concrete shall be placed over a polyethylene vapor barrier.h.All aluminum components embedded within concrete shallbe coated with a bituminous paint or epoxy.7.All flashing and weatherproofing shall be provided by the contractor.8.Use of these plans acknowledges and accepts a limit of liability notto exceed design and engineering fee.A-1WYNN BUILDINGS CORP
4 EL GRECO
PORT ST LUCIE
FL 34952TP----12/20/21
3" x 3" x 0.125"POSTINTERNAL/EXTERNAL3" x 3" x 1/8" EXTRUDEDPOST BASE W/ (2) 3/8"DIA. THRU BOLTS(2) 3/8" DIA. CONCRETESCREW ANCHORS(3" CONC. EMBED)3" x 3" POST TO CONCRETE CONNECTION DETAILSCALE: NTSBA-2EXISTINGBUILDINGFLASHING2" x 5" SMB#14 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.3" RISERPANEL1 1/2" x 2 1/8" x 1 1/2" x 0.125"ALUM RECEIVING CHANNELW/ (7) #12 x 3/4" SMS EACHSIDE OF BEAM & (4) 3/8" DIA.THRU BOLTS INTO THE POST2" x 8" SMBS-2A-2RISER PANEL TO POST CONNECTION @ 4TH WALL DETAILSCALE: NTS3" x 3" x 0.125"POST#14 SMS x 3/4" W/NEOPRENE FACEDWASHER @ 12" O.C.ALONG LENGTHOF ALL BEAMSRISER PANEL TO CORNER POST CONNECTIONSCALE: NTS#14 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.3" RISERPANEL2" x 5" SMB3" x 3" x 0.125"POST1 1/2" x 2 1/8" x 1 1/2" x 8" x 0.125" ALUMRECEIVING CHANNEL W/ (7)#14 x 3/4" SMS EACH SIDE OFBEAM & (4) 3/8" DIA. THRU BOLTSINTO POSTSA-22" x 8"SMB#14 x 3/4" SMS W/ NEOPRENEFACED WASHER @ 12" O.C.ALONG LENGTH OF ALLEND / CROSS BEAMSRISER PANEL TO CORNER POST CONNECTIONSCALE: NTS#14 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.3" RISERPANEL2" x 5" SMB3" x 3" x 0.125"POST1 1/2" x 2 1/8" x 1 1/2" x 5" x 0.125"ALUM RECEIVING CHANNEL W/ (4)#14 x 3/4" SMS EACH SIDE OFBEAM & (3) 3/8" DIA. THRU BOLTSINTO POSTS-1A-22" x 5"SMB#14 x 3/4" SMS W/ NEOPRENEFACED WASHER @ 12" O.C.ALONG LENGTH OF ALLEND / CROSS BEAMSCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISION12SHEET NO:34PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA BUSINESS REGISTRY LICENSE NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.ALUMINUM MEMBERS DIMENSIONSHOLLOW SECTIONS2 x 2: 2” x 2” x 0.046”2 x 3: 2” x 3” x 0.050”2 x 4: 2” x 4” x 0.050”2 x 5: 2” x 5” x 0.050”OPEN BACK SECTIONS1 x 2: 1” x 2” x 0.040”1 x 3: 1” x 3” x 0.045” SNAP SECTIONS2 x 2 Snap: 2” x 2” x 0.045”2 x 3 Snap: 2” x 3” x 0.050”2 x 4 Snap: 2” x 4” x 0.045”SELF MATING (SMB)2 x 4 SMB: 2” x 4” x 0.044” x 0.100”2 x 5 SMB: 2” x 5” x 0.050” x 0.100”2 x 6 SMB: 2” x 6” x 0.050” x 0.120”2 x 7 SMB: 2” x 7” x 0.057” x 0.120”2 x 8 SMB: 2” x 8” x 0.072” x 0.124”2 x 9 SMB: 2” x 9” x 0.072” x 0.124”2 x 10 SMB: 2” x 10” x 0.092” x 0.398”MINIMUM FASTENER EDGE DISTANCE: 1/2"MINIMUM FASTENER SPACING: 3/4"CONCRETE SCREW ANCHOR:SIMPSON TITEN HD OR EQUIVALENTSHEET METAL SCREWS (SMS):ITW / BUILDEX OR EQUIVALENTA-2-WYNN BUILDINGS CORP
4 EL GRECO
PORT ST LUCIE
FL 34952TP11/16/21---
INTERMEDIATE BEAM TO CROSS BEAM ATTACHMENTSCALE: NTS2" x 5" SMB1 1/2" x 2 1/8" x 1 1/2" x 0.125"BEAM DEPTH CHANNEL W/(4) #14 x 3/4" SMS INTOBEAM EACH SIDE &(4) #14 x 3/4" SMS INTOEND BEAM2" x 8" SMBCROSS BEAMS-4A-32" x 5" SMB1 1/2" x 2 1/8" x 1 1/2" x 0.125"BEAM DEPTH CHANNEL W/(4) #14 x 3/4" SMS INTOBEAM EACH SIDE &(4) #14 x 3/4" SMS INTOEND BEAMINTERMEDIATE BEAM TO END BEAM ATTACHMENTSCALE: NTS2" x 5" SMB1 1/2" x 2 1/8" x 1 1/2" x 0.0125"BEAM DEPTH CHANNEL W/(4) #14 x 3/4" SMS INTOBEAM EACH SIDE &(4) #14 x 3/4" SMS INTOEND BEAM2" x 5" SMBEND BEAMS-3A-33" x 3" x 0.125"POSTFLASHING#14 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.2" x 5" SMB3" RISERPANEL1 1/2" x 2 1/8" x 1 1/2" x 0.125"ALUM RECEIVING CHANNELW/ (4) #12 x 3/4" SMS EACHSIDE OF BEAM & (3) 3/8" DIA.THRU BOLTS INTO THE POST2" x 5"SMBEND BEAM#14 x 3/4" SMS W/ NEOPRENEFACED WASHER @ 12" O.C.ALONG LENGTH OF ALLEND / CROSS BEAMSS-5A-3RISER PANEL TO RIDGE BEAM CONNECTIONSCALE: NTS2" x 5"SMBEND BEAMKNEE BRACE CONNECTION DETAILSCALE: NTSS-7A-32" x SMBEDGE BEAM2" x 3" x 0.045"KNEE BRACE3" x 3" x 0.125"POST1 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO POST3" RISERPANEL12"12" MAXOVERHANG#12 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.12"#14 x 3/4" SMS W/ NEOPRENEFACED WASHER @ 12" O.C.ALONG LENGTH OF ALLEND / CROSS BEAMS1 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO BEAMKNEE BRACE CONNECTION DETAILSCALE: NTSS-6A-32" x SMBEDGE BEAM2" x 3" x 0.045"KNEE BRACE3" x 3" x 0.125"POST1 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO POST3" RISERPANEL12"12"2" x 3" x 0.045"KNEE BRACE1 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO POST#14 x 3/4" SMS W/NEOPRENE FACEDWASHER @ 4" O.C.COPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISION12SHEET NO:34PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA BUSINESS REGISTRY LICENSE NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.A-3-WYNN BUILDINGS CORP
4 EL GRECO
PORT ST LUCIE
FL 34952TP11/16/21---