Loading...
HomeMy WebLinkAboutBoundary Survey Plot PlanNW CORNER I SECTION 25 1 3 CO N F of CO 00o o I 1? z Iri °' 1,0 0.32' N88' 4'06"W i 30.00' F- O J r SIRC 30.00' N CD v DO O ,~ cD O a_ L 41 = 0) N o M 0 Ln O O O z 5' W00? POST ,h°, 30.00, FIRC I I. 00 0 `° co I I 0 0 0 0 0 F (n 6 LEGEND: -OHE = OVERHEAD UTILITY LINES .• WUP = WOOD. UTILITY POLE ORB = OFFICIAL RECORD BOOK PG = PAGE SIRC = SET IRON ROD AND CAP #6376 FIRC = FOUND IRON ROD AND CAP. BECK SURVEYING. NGVD = NATIONAL GEODEDIC VERTICAL DATUM CONC. = CONCRETE � S88'02'19"E 346.10' S88"02'19"E 10' BUILDING SETBACK LOT 12 (REMAINING NORTH PORTION) VACANT 346.10' s m DRIVE VX5' CONIC. WELL PUMP PAD CONCRETE — — — — — — ;15225' — — — 32.0' — — — — o PORT o \ Y N N \ OO Q M ' 0 DO ON ad 8 L \ ILL] I 4- 0 ESIDENCE ' a \ l0 ROFF - 20.00' i 0 0 4.G \ \\ �s Z 41 46.0 Mi 124.69' 152.52' 38.7 � M �\ in o In DRAIN I \ \-0 In — nELD I _ Ln SEPTIC — — TANK of ail ml ml I I t10' BUILDING SETBACK N88"02'19"W 'se 346.10' BENCHMARK/REFERENCE POINT LOCATION SIX INCH NAIL DRIVEN IN WOOD UTILITY POLE l ELEVATION = 16.58. LOT 12 (REMAINING SOUTH PORTION) VACANT FIL6 Cory DRIVE — — 124.88' — WOOD do CONC. S88'02'19"E 346.10' LEGAL DESCRIPTION: The South 165 feet of the North 660 feet of Lot 12, Block 2, Section 25, Townsl1p 36 South, Range 40 East, Plat No. 1 Saint Lucie Gardens, according to the map or:plat, thereof, recorded in Plat Book 1, page 35, Public Records of St. Lucie County, Florida. LOT AREA: 57,063.60 Square. Feet; 1.31 Acres±. T STREET ADDRESS: Dyer Road, Port Saint Lucie, Florida. j� SURVEYORS' NOTES: 1. Bearings shown hereon are based on the West Section Line of Section 25 as platted and bears N 00'18'25" W. 2. Written dimensions take precedence over scaled dimensions and distances are not to be scaled for construction and/or design purposes. 3. All distances and bearings- are as field measured and are coincident with "PLAT" and description data unless otherwise noted. 4. This drawing is not valid without the signature and original SIRC raised seal of a Florida licensed Surveyor & Mapper. 5. This survey is based upon a description furnished by the ,s client,, there has been no extensive search . of the public records done by this office. N CERTIFIED TO: u7 Leslie D. Trudeau O St. Lucie Title Services, Inc. WFG National Title Insurance Company .J Q i ZQ W U N CERTIFICATION: In I hereby certify that the survey represented hereon was (p performed under my supervision and it complies with, the minimum technical standards, as set forth by the Florida Board of Surveyors & Mappers in Chapter 5J-17.050(10)(a)—(k) of the Florida Administrative Code, pursuant to Section 472.027, Florida Statutes, and further that there are no visible, above ground encroachments unless shown or noted. SIRC 's STEVEN D. MARSHALL s Date of Signature Professional Surveyor Mapper Florida Certificate No. 6-27-16 Final Survey. Go 8-12-15 Adjust elev. to NAVD & add FF. SDM.. 7-27-15 Legal & Certified to additions. SDM REVISIONS: 7-20-15 Add Road & Drainage Right—of—Wa BOUNDARY SURVEY/PLOT PLAN MARS -HALL Prepared on the order of: Surveying & Mapping Larry Seegott Y 321 Holly Avenue Field: SM/SB Job No.: 15-1529 Port aint Lucie, FL 34952 Drawn: SDM Date: 06/29/2015 Scale: 1" = 40' Sheet: 1 of 1