HomeMy WebLinkAboutFloor PlanNEW MIN R-19 BLOWN INSULATION ATTACH PT 2 x 4 TOP PLATE TO EXISTING HEADER BEAM — w/ 1/4" LAG SCREWS m 16" O,C, MIN EMBED 1 1/2" 1/2' DRYWALL OVER - 2 x 4 STUDS m 16" O.C. FRAME WALL w/ MiN. R-II INSULATION I EXISTING SLAB / FOUNDATION EXISTING ROOF T-I11 5HEATING (TO MATCH EXISTING) OVER PAPER BACKED OVER VAPOR BARRIER 114" TAPCON ANCHORS m 36" O.C, MAX. ( MAX. 6" FROM CORNERS ) 2 x 4 PT SILL PLATE w✓ SIMPSON SP4 6 EACH STUD TOP 4 BTM, FRAME 5PF WALL STUDS m 16 O.C. MAX. EXISTING FINISH ELEV. TYPICAL FRAME -IN FOR PORCH WALL SECTION NTS CONCRETE REPAIR FOR PLUMBING 1. REMOVE DELAMINATED OR OTHERWISE UNSOUND CONCRETE, FROM AREA TO BE PATCHED, SAW CUT AS NECESSARY TO PREPARE AFFECTED AREA. 2, DO NOT CUT REINFORCING STEEL, IF REINFORCING STEEL 15 REVEALED REMOVAL SHALL CONTINUE UNTiL 4" OF REINFORCING STEEL 15 REVEALED. 3. REMOVE CONCRETE AROUND REINFORCING STEEL APPROX. i" AROUND TO ALLOW NEW CONCRETE TO SURROUND REINFORCING STEEL. 4. COAT REINFORCING;. STEEL WITH SIKA ARMATEC 110 OR EQUAL. 5. EXISTING CONCRETE SHOULD BE PREPARED W/ A BONDING AGENT FOR PATCH, 6, POUR BACK REPAIR AREA WITH A CONCRETE MIX WITH A MIN F-C = 4000 PSI, MIX SHOULD INCLUDE A CORROSION INHIBITOR ADMIXTURE- 1. A FORM MAY BE USED TO ALLOW FOR A PROPER EDGE 4 PROPER DRYING IN PLACE OF PATCH. FRONT ELEVATION SCALE: 1/4" - 1'-0" FLOOR PLAN SCALE: 114' = 1'-0" REMODELING, ADDITION, ALTERATION, AND GENERAL NOTES CONSTRUCTION TO FOLLOW 2020 'ITH EDITION FLORIDA BUILDING CODE 4 ALL AMENDMENTS 1. Cortractor to verify all dimensions prior 5. Do not scale drawings, if there are written S. No egress from a bedroom or sleeping area to the commencement of construction, dimensions to take precedence. Dimensions has been compromised by this enclosure. 2. Determine the existence of any underground and construction details may vary due to tanks, drain fields, wiring, plumbing, piping, etc. substitution, field conditions, construction and stow for same during construction, technique: or other variables. 3. Verify adequacy of existing electrical service 6, These drawings are not intended to cover all and wiring capacity. Upgrade and sub -panel as conditions. Field decisions may need to be NOTICE: required. Relocate any tv, phone cable, made by Contractor. If this situation arises, please It is important that the Client and Contractor examine the thermostat, fans, chimes, outlets, switches, contact Engineer of Record, drawings and documentation In detail. It shall be the final smoke detectors, fixtures, etc. as may be Contractor shall allow for minor adjustments. responsibility of the Contractor to review and double check required, 1. Certain assumptions have been made using the the plans for accuracy arol compliance with regulatory agencies. It is customary 4. All woad members exposed to weather or to best Judgement and experience of the design a g y and ordinary not to include details contact concrete and/or masonry shall be team. No demolition has been undertaken by well within the knowledge of licensed Contractor. If pressure treated, necessary, further clarification of these plans should be p the designer to verPf the conditions and y achieved before signing the construction contract and construction teohlnicpLee employed in the obtaining a building permit, otherwise the Contractor assumes existing structure. The contractor shall verify responsibility for the construction in question. Methods of actual conditions prior to undertaking construction shall be determined by the Contractor. construction. ELECTRICAL NOTES I. ALL ELECTRICAL WORK SHALL BE DONE IN ACI�ORDANGE WiTH THE 2011 NATIONAL ELECTRIC CODE 4 CONFORM WiTH THE FBC 4 ALL LOCAL CODES, 2: ALL ELECTRIC COMPONENTS SHALL BE TIED TO EX15TING ELECTRIC 200 AMP 5ERVICE 4 PANEL SPARES 3: ENGINEER OF RECORD NOT RESPONSIBLE f - • `• � rli I Vol I I I I REMOVE EXISTING SCREENROOM I i i I I I I I PLUMBING RISER DIAGRAM ALL PLUMBING TO FOLLOW REQUIREMENTS OF THE FBC 2020 3"" VTR I I1�4° LAV 3" W.C. 2" TUB 3" 4"" C.O. 4 TO SEPTIC OR SEWER 2020 1TH EDITION FBC 4 AMENDMENTS BASIC WIND SPEED 160 MPH ULT - 3 SEC GUST RI5K CATEGORY 1.0 BUILDING: CATEGORY ENCLOSED EXPOSURE CATEGORY B WIND DESIGN PRESSURES WALL / DOOR / COMPONENTS - +34.3 / -39.8 PT2x4 TOP PLATE CONNECT NEW FRAME WALL w/ 1/4" LAG SCREWS TO WOOD OR 1/4" TAPCON ANCHC TO CONC, - 4" FR" ENDS 4 16"' O,C, i`"A; TG EXISTINC"s STRUG' 2x4SPFST m 16" O.C. FRAME WALL EXISTING FRAME CON5TRUC 2x4PT BILL PLATE FRAME WALL INFILL TO EXISTING: STRUCTURE ATTACHMENT DETAIL NTS RIGHT E�CYA I IVN SCALE: 1/4" = 1'-0" STRUCTURAL NOTES 1. ALL LUMBER IN CONTACT. WITH CONCRETE - OR MASONRY WILL BE PRESSURE TREATED. 2, ALL STANDARD LUMBER SHALL BE SPF 03, HEM FUR 03 OF STUD GRADE: WITH A MINIMUM FB = 1200 PSI OR BETTER 3. SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 4. UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURERS INSTRUCTIONS AMC) STANDARD PRACTICE. 5. UNLESS OTHERWISE NOTED FOR EXTERIOR -WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH BD RINGSHANK OR BETTER NAILS (IOD NAILS WHEN W SHEATHING IS USED) 6" O.C. EDGES AND S" O,C, ON FIELD, OR SCREWED WITH DRYWALL SCREWS 1V2 INCHES LONG AMC) 0.131 INCHES DIAMETER FOR,CH ENCLOSURE ALTERATION -LEVEL II ENCLOSE EXISTING COVERED PORCH PRODUCT APPROVAL SUBMITTAL AFFIDAVIT PRODUCT PROD. DESIGN PRODUCT MANUF, MC)DEL " APPROVAL PRESSURES SH WINDOW ALENCO 3753 FL FL 10788.1 +35 / -47.2 ALUM sH PSF " EASTERN SHUTTER METALS GALV. STEEL FL 11864 2 +/- 55 PSF SUPPLY 24 GAUGE •• A FLORIDA PRODUCT APPROVED HURRICANE SHUTTER OF EQUAL OR BETTER QUALITY MAY BE USED IN PLACE OF THIS SHUTTER. THE FLORIDA PRODUCT APPROVAL MUST BE PRESENTED FOR CONFIRMATION UPON INSPECTION. I HAVE REVIEWED THE ABOVE COMPONENTS AND CLADDING, AND HAVE APPROVED THEIR USE iN THE STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND RECEIVED FORCES SPECIFIED BY THE CURRE'J CODE PROVISIONS, FEB 26 2021 AS SiGNER 4 DATED BELOW. raermRdng DuPartment .St. Luclz County FDOH in St. Lucie County Environmental Health Septic Sygtem Appears Adequate For Proposed Construction jjj / 2IN16y This Approval Does Not Guarantee Perfo nance of the stem Reviewer: Y .� a aa�a l O w wM O �QAM� • C7 A � zo.�R � o Z o av w oo�a RNC7, F� r r' i f f • �r r r 1 f f e Copyright 2021 ROBERSON DESIGN GROUP rill rights reserved. REVISION DATE 2-21-21 JOB • 21025W DATE : 2/19/21 DRAWN BY SR SHEET 1 ®f 1