HomeMy WebLinkAboutAPPROVED Revised plan NO 1H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
MAX. WIDTH:
MIN. DEPTH:
14'
SHAPE:
FILL FROM EXCAVATION:
TILE:FILTER:
PUMP HP:
LIGHTS:
TRNFORM:
MAIN DRAIN:
SKIMMER:
RETURNS:
VALVED VAC LINE:
DISCHARGE LINE:
CHLORINATOR:
HANDRAIL:
DIVING BOARD:
HEATER:
VACUUM HEAD:
VACUUM HOSE:
LEAF SKIMMER:
SHEER DESCENT
REMOVE EXISITING CONCRETE:
OVERFLOW LINE
ELECTRICAL:
POOL PATIO:
EXISTING PATIO:
DECK DRAIN:
POOL CAPACITY:
TURN-OVER RATE:
TERMITE TREAT:BARRIER:
MAX. LENGTH:23'8"
3'6"MAX. DEPTH:5'6"
CUST
HAUL
ELEVATION:TBD
INTERIOR FINISH:GEM CS200
POOL SPA
POOL 1 COLOR LED SPA NA
POOL SPA
POOL 2 SPA NA
1
POOL 3 SPA NA
JETS:POOL NA SPA NA
INCL FILL LINE:NA
TO GROUND
AQUA PURE SALT SYSTEM
INCL LADDER:NA
NA SLIDE:NA
N/A
INCL
INCL
INCL
POLE:
BRUSH:
TEST KIT:
INCL
INCL
INCL
NA
INCL
SCREEN ENCLOSURE:
ED’S ELECTRIC
CONCRETE / FLOCRETE
INCL
6-HRS.
INCL
NA
MAX. WATER VELOCITY:
MIN. SKIMMER FLOW:
SURFACE AREA OF POOL:
SPECIFICATIONS
NA
100 WATT NA
LEAVE AS IS
PUMP MAKE PER FBC 4501.20
1.65 FLO PRO V.S.
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
GENERAL NOTES:
1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND
WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS.
2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL
WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE
CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS)
COMPRESSIVE STRENGTH.
3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F.,
OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING
CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN.
4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40.
5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F.
APPROVAL.
6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES.
7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES.
SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES.
PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR.
8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS
NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER
DISPOSAL SYSTEM.
9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF
THE SUCTION LINE
10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A
MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE.
11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA"
HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL
CODE- LATEST EDITION.
12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL,
LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS,
DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED
TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER
THAN #8 COPPER.
13. NO OVERHEAD OPEN WIRE OVER POOL WATER.
14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED
3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED.
15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT
SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY
LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY.
16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO
PREVENT UNDERMINING.
17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT
SYSTEMS (SPECIES SELECTION BY OTHERS).
AARON H. ALLEN PE, FL REG. NO. 86620 FL
A. ALLEN ENGINEERING LLC, CA NO. 33042
2367 7TH STREET, LA VERNE, CA 91750
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODES
8,583 GALLONS
SPA CAPACITY:NA
25 GPM
255
PERIMETER OF POOL: 63
SEAL:
BUILDER/JOB NAME:
PERMIT NO.:
DATE DRAWN:
TBD
4/2/2021
DRAWN BY:
CHECKED BY:
APPROVED BY:
FIELDS
ADDRESS:2115 TROWBRIDGE RD
JORDAN VANDUZER
AARON H. ALLEN
SCALE:¼” = 1'
CITY:FORT PIERCE FL 34945
JOB INFORMATION
NA
SECTION THRU POOL 1
AScale: NTS
WALL THICKNESS REQ.4
AScale: NTS
TYP. WALL SECTION & WELL PT.5
AScale: NTS
POOL DRAIN TYP.6
AScale: NTS
EQUIPOTENTIAL BOND GRID 7
AScale: NTS
WATER BONDING 8
AScale: NTS
ELECTRICAL SCHEMATIC 7
CScale: NTS
HANDRAIL BONDING 7
BScale: NTS
W.L.
#8 SOLID COPPER BOND
WIRE W/ APPR. CLAMPS
(SEE NOTE 3)
8 GAUGE SOLID COPPER WIRE
SOIL
18" MIN.
(ENTIRE PERIMETER)
NOTES:
1. MINIMUM 18" FROM ENTIRE EDGE OF POOL PERIMETER BURIED 4" TO 6" DEEP
2. INSTALL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED)
3. #8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS ON EACH SIDE OF POOL (4 TOTAL)
DECK PER DETAIL A/5
ANSI-7/ANSI-15 8
EScale: NTS
POOL DRAIN CERTIFICATION 7
EScale: NTS
EQUIPMENT LAYOUT 7
GScale: NTS
UNDERWATER LIGHT 8
BScale: NTS
PUMP CURVES 7
HScale: NTS
SHORING REQUIREMENTS 3
AScale: NTS
SOIL
EQUIPMENT PAD
PB-2008
BONDING WIRE
TO GRID VARIESNOTE:
1. PB-2008 TO BE INSTALLED NEAR OR UNDER EQUIPMENT PAD
FROM POWER SUPPLY
POOL FINISH
APPROVED GROUND CLAMP
CONTINUOUS BOND WIRE
COMMON TO POOL STEEL,
RAILS & EQUIPMENT
1" LIGHT CONDUIT
WATER LEVEL
NICHELESS
UNDERWATER
LIGHT 18" MIN.EXIST. FTGN.
SOIL
3 ft.
6 ft.
9 ft.5 ft.4" WALL #3
REBAR @ 12"
O.C.E.W.ANGLE OF REPOSENOTES:
EXCAVATION INTO ANGLE OF REPOSE ALLOWED IF:
1. SHORING IS SUFFICIENT TO SECURE SOILS FROM EROSION/SETTLEMENT
2. NO UNDERMINING OCCURS UNLESS APPROVED BY ENGINEER
3. COMPACTION TEST PROVIDED AT C.O.
6" WALL #3
REBAR @ 12"
O.C.E.W.
8" WALL #3
REBAR @ 12"
O.C.E.W.
2"X4" @ 24" O.C.
½" PLYWOOD
NOTE:
1. SHORING TO BE INSTALLED WHEN POOL
SHELL IS CLOSER THAN 5 FT TO HOME,
OR EXCEEDS THE ONE TO ONE RATIO OF
THE ANGLE OF REPOSE EXIST. FTGN.
SOIL
< 5' OR 1:1
MAIN DRAIN
SKIMMER
COLOR LED
VACUUM LINE
SYMBOL LEGEND
DECO DRAIN
EXISTING FACILITY CHANNEL
DRAIN
ELEVATION MARKER
B BUBBLER
JANDY UPLIGHTUL
DOOR/WINDOW ALARM
BABY BARRIER
XX.X’
DECK PER DETAIL A/5
x0 ft.2 ft. 4.8 in.4 ft.8 ft.
REVISION DATE:EXTEND DECK AND FENCE (SEE CLOUD) 3/21/22
SWIMOUT CUT SECTION 8
HScale: NTS
20" MAX.
18"
8880 GLADES CUT OFF ROAD
PORT ST. LUCIE, FL 34986
CUSTOMER APPROVAL:
REVISION
NOTE:
1. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE
DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS.
TYP. FOOTER SECTION 2
BScale: NTS
NOTE:
1. WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE
#8 GROUND WIRE
DECK PER DETAIL A/5
FILTRATION PUMP
LOW SPEED
8"
CUT SECTIONTOP VIEW
8"
8"
Eq.VARIESNOTE:
1. STEEL REINFORCEMENT IN CONCRETE AGAINST EARTH SHALL HAVE A MINIMUM COVER OF 2"
Eq.Eq.
Eq.
4"
6"X6" TILE
INTERIOR
FINISH
CONCRETE
#3 @ 12" O.C.B.W.
TO PUMP
THREADED
PLUG
SECURED GRATE
TOOLS REQUIRED
FOR REMOVAL
GRAVEL
BED
NOTES:
1. REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN
& ATTACH AUX. PUMP LINE WHEN EMPTYING POOL
2. FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @
6" O.C.
3. SLOPE DECK ¼” PER FOOT 4"
COMPACTED SOIL
30" CLEARANCE IN
FRONT
OF SUBPANEL
F
P1
SALT
POOL BARRIER PER FRC 4501.17.1.8
BURIED POWER LINES
POOL BARRIER PER FBC 4501.17-41.1.17.3 AND
ANSI/NSPI-5-1995 NSF CERTIFIED TO ASTM F 2208-08
4. 2500 PSI FIBER REINFORCED
CONCRETE PUMPMIX
OVERPOUR
6 FPS FROM TRUNK
TO 8FPS SUCTION LINES,10FPS MAX RETURN
REC. PUMP = 1.65HP JANDY FLOPRO VARIABLE SPEED
LOW SPEED – 36 GPM MAX
HIGH SPEED = 98 GPM @ 38 TDH
3" BRANCH PIPE @ 98 GPM = 5.74 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" SUCTION PIPE @ 98 GPM = 7.48 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
2" PRESSURE PIPE @ 98 GPM = 9.77 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM
BACKWASH VALVE NO
APPROVED WITH THE 2020 FLORIDA BUILDING CODE
FOR RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7
2013 FOR SUCTION ENTRAPMENT AVOIDANCE
2.5" SUCTION LINE MAX 117 G.P.M.
TO FILTRATION PUMP
3" PLUMBING LINES
FROM SUMP W/ 3" TEE
3 FT. MIN.
6 FPS MAX
8 FPS MAX
WATERWAY MAIN DRAINS
MIN. 3' SEPARATION REQ.
NOTES:
1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B.
ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) -
COVERS MUST BE REPLACED EVERY 5 YEARS
2. APPROVED WITH THE 2020 FLORIDA BUILDING CODE FOR
RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7 2013 FOR
SUCTION ENTRAPMENT AVOIDANCE
52
P1 W
F
VS
43
B
KEY:
1. 2" RETURN LINE TO DECK JETS
2. 2" RETURN LINE TO POOL
3. 2" VACUUM LINE
4. 2" SKIMMER LINE
5. 2.5" MAIN DRAIN LINE
P1. 1.65HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT
STRAINER
F. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE
(MUST HOLD 35 PSI FOR 30 MINUTES MINIMUM)
W. 1.5" TO WASTE OR TO GROUND
V. VALVES (TYP)
B. PB-2008 WATER BONDING TO GRID (SEE DETAIL A/8)
S. JANDY “AQUA PURE 1400” SALT SYSTEM
1
EQ EQUIPMENT PAD
PER FBC
4501.22(9.2)
POOL EQUIPMENT ANCHORED PER
FLORIDA BUILDING CODE 2020 &R4501.22
NOTES:
1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE.
2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER.
4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B)
5. INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10'
AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL
6. POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE
POOL
7. PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS
PER HO-26 OF NFPA 70
S.P.S.T. TOGGLE
SWITCH
#8 SOLID CU GROUND WIRE
TO EXISTING PANEL
40 AMP POOL PANEL
W/(3) - #10 THHN CU WITHIN
1”
ELECTRICAL CONDUIT
VARIABLE SPEED PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITH-IN ½” CONDUIT
TIME CLOCK
W.P. DISCONNECT
W.P. DISCONNECT
SALT SYSTEM W/BUILT IN OVERLOAD
SWITCH W/3-#10 THHN CU WITH-IN ½”
CONDUIT
POOL LIGHTS SEE
SPECS FOR QUANT.
(GFI NOT REQUIRED)
PROPERT FENCE BY PRINCE
D/W ALARMS BY H/OSKIMMER
5'6" DEPTH
TILED BENCH EDGE
3'6" DEPTH
VAC LINE
TILED STEP EDGES
COLOR LED4 ft.18 ft. 9 in.5 ft.
47 ft. 7 in.5 ft.LEAVE LANAI AS IS23 ft.23 ft.DECK DRAIN
(2) JANDY BRAND DECK JETS
23'8"
0
FLOOR SLOPES
#3 STEEL @ 12" O/C E.W.
WATERLINE TILE
MAIN DRAIN
4’ EQ.
6"
5'6"
3.5'
4-½”
10" MIN.
STEP NOTES:
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 4000 PSI.
4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER
OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY
NOTES:
1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1
FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE
2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9
INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END
3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT
EXCEED 1 FOOT IN 3 FEET
4. WALLS SHALL NOT SLOPE > 11 DEGREES
5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL
12" MAX
12" MAX
12" MAX
3’
12" MAX
4' ALUMINUM RAIL FENCE BY PRINCE
DEVELOPMENT
3 ft. 6 in.6 ft. 6 in.15 ft.P348 PVC HANDRAIL-TAUPE
COLOR
VERIFY PLACEMENT IN FIELD 12 ft.1"1"
2" RETURN TO DECK JETS
2"
1" OVERFLOW LINE
3"
3"
2.5"
R 1.5"
1.5"
R
1.5"
2"
1"1.5"
x 4'6"R5'3"R 5'R6'R7'RR 5'R5'R10'3"10'10'10'3"1
1
'
6
"13'5 '9 "7'3'9"= DOOR AND WINDOW ALARMS BY HOMEOWNERx
EXTEND DECK 15'9"X23' ON LEFT
SIDE
EXTEND FENCING
xx