HomeMy WebLinkAboutAPPROVED NOA 18-0919.12058Membrane Type:
SBS/SBS Cold Applied
Deck Type 1:
Wood, Non -insulated
Deck Description:
Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(1):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and Sjyystem [,imitations shall apply,
Fire Barrier: � J/�-j
FireOui`" Fire Barrier Coating, VersaShielde Fire -Resistant Roof Deck Protection,
(optional) "'��
VersaShieldm Solo"' Fire -Resistant Slip Sheet, DensDeck'Roof Board,
SECUROCK* Gypsum -Fiber Roof Board, or SECUROCK Glass -Mat Roof Board,
Base sheet:
GAFGLAS" #80 Ultima' Base Sheet, GAYGLAV Strataven& Nailable Venting
Base Sheet, Ruberoid'" 20 Smooth, Ruberoid* HW Smooth or Ruberoid' HW 25
Smooth base sheet mechanically fastened to deck as described below:
Fastening
GAFGLASm Ply 4, Tri-Ply* Ply 4 Ply Sheet, GAFGLAS* FlexPly' 6, GAFGLAS°'
Option #1:
#75 Base Sheet, Tri-Ply' #75 Base Sheet or any of above base sheets attached to
deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"
o,c. at the lap staggered and in two rows 18" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure ,45 psf. See General Limitation #9)
Fastening
GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLASm FlexPly' 6, GAFGLAS,'
Option #2;
#75 Base Sheet, Tri-Ply' #75 Base Sheet or any of above base sheets attached to
deck with Drill-Tec' #12 Fastener or Drill-Tec' #14 Fastener and Drill-Tec" 3"
Steel Plate, Drill-Tcc' AccuTrae" Flat Plate or Drill-Tec' AccuTrac" Recessed
Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are
equally spaced approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure -43 psf. See General Limitation #9)
Fastening
Option #3:
GAFGLAS' FlexPlr 6, GAFGLAS" #75 Base Sheet Tri-Ply* #75 Base Sheet or
an of above base sheets attached to deck with ggroved annuli shank nails
-
and tin cans at a fastener spacing_ of 9" o.c. at the 4" lap stammered and in two rows
9" o.c. in the field.
Not for use with DensDgck or SEQII&OCK Fire Barrier
(Maximum Design Pressure -52.5 psf. See General Limitation #7)
Fastening GAFGLAS® #75 Base Sheet, Tri-Plym #75 Base Sheet or any of above base sheets
Option #4: attached to deck with Drill-Tec' # 12 Fastener or Drill-Tec' #14 Fastener and Drill-
Tec' 3" Steel Plate, Drill-Tec' AccuTrae Flat Plate or Drill-Tec' AccuTrac#
Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other
rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure -45 psj. See General Limitation #9)
Fastening GAFGLASm #80 Ultima' Base Sheet, Ruberoid" 20 Smooth, Ruberoid' Mop
Option #5: Smooth base sheet attached to deck approved annular ring shank nails and 3"
inverted Drill-Tec' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap
staggered in two rows 9" in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure -60 psf. See General Limitation #7)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: I t/01/18
Page 51 of 67
Fastening GAFGLAS* 075 Base Sheet, Tri-Ply* #75 Base Sheet or any of above base sheets
Option #6: attached to deck with Drill-Tec' # 12 Fastener or Drill -Tee' # 14 Fastener and Drill-
Tec' 3" Steel Plate, Drill-Tec' AccuTrac* Flat Plate or Drill-Tec' AccuTrac*
Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other
rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf. See General Limitation #7)
Ply Sheet; (Optional) One or more plies GAFGLAS* Ply 4, Tri-Ply* Ply 4 Ply Sheet,
GAFGLAS$ F1exPly- 6, GAFGLAS* #80 Ultima` Base Sheet, Ruberoid* Mop
Smooth, Ruberoid* Mop Smooth 1.5, Ruberoid* Mop Plus Smooth or Ruberoid* 20
Smooth sheet adhered in a full mogging of approved asphalt Aggisl ailhiq„lhg FYT
ran a and at a rate of 20-40 libs./sq.
. memh n : One or more plies of Ruberoid* Mop Smooth, Ruberoid* Mop Smooth 1.5,
Ruberoid* Mop Plus Smooth, Ruberoid* Mori Granule FR. Ruberoid* Mop Granule,
Tri-Ply* SBS Granule Cap Sheet, Intec Flex PRF, , Ruberoid* Mop Plus Granule,
Ruberoid* 20 Smooth, Ruberoid* 30 Granule, Ruberoid* EnergyCap' 30 Granule
FR, Ruberoid* 30 Granule FR, Ruberoid* 30 Plus Granule FR, or Ruberoid* Mop
Pius Granule FR in adhered in a full mopping of approved as halt ! lied within the
EVT range and at a rate of 2040 lbs./sq.
Or
One or more plies of Ruberoid* Mop Smooth, Ruberoid' Mop Smooth 1.5,
Ruberoid* Mop Plus Smooth, Ruberoid* Mop Granule, Tri-Ply* SBS Granule Cap
Sheet, lntec Flex PRF, , Ruberoid* Mop Granule FR, Ruberoid* Mop Plus
Granule, Ruberoid* 20 Smooth, Ruberoid° 30 Granule, Ruberoid* EnergyCap"' 30
Granule FR, Ruberoid* 30 Granule FR, Ruberoid* 30 Pius Granule FR, or
Ruberoid' Mop Plus Granule FR adhered in MatrixTm 102 SBS Membrane Adhesive
at an application rate of 1-2 gal./sq.
Surfacing: O na on granular surfaced membranes; required for smooth membranes.
Chosen components most be applied according to manufacturer's application
Instructions, All coatings most be listed within a current NOA.
1. Gravel or slag applied at 400 lbs,isq. and 300 Ibsjsq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2. GAFGLAS* Mineral -Surfaced Cap Sheet, Tri-Ply", BUR Granule Cap Sheet
or GAFGLAS'EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs..:sq.
3. TOPCOAT* Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT* MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT* Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating,
Maximum Design
Pressure: See Fastening Options
NOA No.: 184919.12
Expiration Date: 11/06/23
Approval Date: 11/01/19
Page 52 of 67
ank
MIAMUM MIAMI-DADE COUNTY
EE ; PRODUCT CONTROL. SECTION
11905 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.mLmId1&&gvlecoaomv
GAF - ------- --- -----
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ),
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoid•Modified Bitumen Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision ar
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date maybe displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-1020.01 and consists of pages I through 67.
The submitted documentation was reviewed by Jorge L. Acebo.
M
NOA No.: IM919.12
Expiration Date: 11106123
Approval Date: 11/01/18
Page I of 67
ROOFING SYSTEM APPROVAL
Roofing
Sub -Category: Modified Bitumen
Material: APP/SBS
Deck erne: Wood
Maximum Design Pressure: 105 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE I
Test
Product
Product
Dimenslons
agidusation
D"Cription
GAFGLAS' Ply 4
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
0 meter) Wide
reinforced with fiberglass mat.
Tri-Ply' Ply 4 Ply Sheet
39.3T'
ASTM D2178
Smooth surfaced asphaltic ply sheet
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS'
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
FlexPly' 6
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS' #75 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base ply sheet
(I meter) Wide
reinforced with fiberglass mat.
Tri-Ply' 475 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS' #80 Ultima' Base
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
Sheet
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS' Stratavene
39.37"
ASTM D4897
Smooth surfaced asphaltic perforated
Perforated Venting Base Sheet
(I meter) Wide
venting base sheet reinforced with
fiberglass mat.
GAFGLAS' Stratavent'
39.37"
ASTM D4897
Smooth surfaced asphaltic nailable venting
Nailable Venting Base Sheet
(I meter) Wide
base sheet reinforced with fiberglass mat.
Bottom side surfaced with granules.
Ruberoid' HW 25 Smooth
39.37"
ASTM D6163
Smooth surfaced torch applied SBS base
(1 meter) Wide
or ply sheet reinforced with a fiberglass
mat.
Ruberoid' HW Smooth
39.37"
ASTM D6164
Smooth surfaced torch applied SBS base
(I meter) Wide
or ply sheet reinforced with a polyester
mat.
Ruberoid' HW Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoid' HW Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced heat.
(I meter) Wide
welded SBS cap sheet reinforced with a
Polyester mat.
Ruberoid' HW Plus Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid' HW Plus Granule
39.37"
ASTM D6164
Fire retardant granule surfaced torch
FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
eeou
NOA No.: 18.0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 2 of 67
Test
Product
Product
Dimensions
Specification
Desert R11
Ruberoid' EnergyCap " HW
l meter
ASTM D6164
Fire retardant granule surfaced heat -
Plus Granule FR
(39.37") Wide
welded SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT' EnergyCote'
Elastomeric Coating,
Ruberoid' Torch Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP base
(1 meter) Wide
or ply sheet reinforced with a polyester
mat.
Tri-Ply' APP Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP cap,
Membrane
(1 meter) Wide
base or ply sheet reinforced with a
Polyester mat.
Ruberoid' Torch Granule
39.37"
ASTM D6222
Granule, surfaced torch applied APP cap
(I meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply' APP Granule Cap
39.37"
ASTM D6222
Granule surfaced torch applied APP cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid' Torch Plus Granule
39.37"
ASTM D6222
Fire retardant granule surfaced torch
FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat.
Ruberoid' EnergyCap'
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Plus Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT' EnergyCote'"
Elastomeric Coating.
Ruberoid' EnergyCar
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Granule FR
(l meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT' EnergyCote,'
Elastomeric Coating.
Ruberoid' 20 Smooth
39.37"
ASTM D6163
SBS polymer -modified asphalt base or ply
(1 meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid' 30 Granule
39.37"
ASTM D6163
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid' 30 Granule FR
39.37"
ASTM D6163
Fire retardant granule surfaced mop
(1 meter) Wide
applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid' 30 Plus Granule FR
39.37"
ASTM D6163
Fire retardant granule surfaced mop
(1 meter) Wide
applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid' Mop Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply' SBS Granule Cap
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Intec Flex PRF
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoid' Mop Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base
(1 meter) Wide
sheet reinforced with a polyester mat.
NOA No.: 194919.12
Expiration Date: 11106l23
Approval Dste: 11/01/18
Page 3 of 67
Test
Product
odu t
Dimensions
Specification
Description
Ruberoid' Mop Smooth 1.5
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoidm Mop Plus Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoidm Mop Plus Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoidm Mop Plus Granule
39.37"
ASTM 136164
Fire retardant granule surfaced mop
FR
(I meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
Ruberoidm EnergyCap' Mop
39.37"
ASTM D6164
Fire retardant granule surfaced mop
Plus Granule FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT' EnergyCote'
Elastomeric Coating.
Ruberoid' Mop Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced mop
(I meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid® EnergyCap' 30
39.37"
ASTM D6163
Fire retardant granule surfaced mop
Granule FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
fiberglass mat. Cap sheet is factory coated
with TOPCOAT' EnergyCote'
Elastomeric Coating.
GAFGLAS' Mineral -Surfaced
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Cap Sheet
(l meter) Wide
reinforced with fiberglass mat.
Tri-Ply' BUR Granule Cap
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Sheet
(I meter) wide
reinforced with a fiberglass mat.
GAFGLASm EnergyCap'
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Mineral -Surfaced Cap Sheet
(I meter) Wide
reinforced with fiberglass mat. Cap sheet
is factory coated with TOPCOAT'
EnergyCote' Elastomeric Coating.
TOPCOAT' Membrane
1, 5 or 55 gallons
ASTM D6083
Water based elastomeric coating.
United Coatings' Roof Mate
1, 5 or 55
ASTM D6083
Water -based elastomeric coating
TCM Coating
Gallons
TOPCOAT' 5 or 55 gallons ASTM D6083
Surface Seal SB
United Coatings' Surface Seal 5 or 55 Gallons ASTM D6083
SB Roof Coating
TOPCOAT' MB Plus
United Coatings' Roof Mate
MB Plus Coating
5 or 55 gallons Proprietary
5 or 55 Gallons Proprietary
Solvent based thermoplastic rubber sealant
designed to protect and restore aged roof
surfaces and to increase roof reflectivity.
Solvent -based thermoplastic rubber
sealant designed to protect and restore
aged roof surfaces and to increase roof
reflectivity.
Water based, low VOC primer used to
block asphalt bleed -through.
Water based, low VOC primer designed to
block asphalt bleed -through.
NOA No.: 18-0919.12
cm Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 4 of 67
P-roduc
Dimenflons
Fire0ut' Fire Barrier Coating
5 or 55 gallons
Flex Seal'
1, 5 gallons
or 1 qt. tube
VersaShield" Fire -Resistant
12" x 100' rolls
Roof Dock Protection
VersaShield' Solo' Fire-
42" roll wide,
Resistant Slip Sheet
100 R,
Matrix' 102 SBS Membrane 3, 5 or 55 gallons
Adhesive
APPROVED INSULATIONS:
Product Name
EnergyGuard'"
Polyiso Insulation
EnergyGuard'
Tapered Polyiso Insulation
EnergyGuard'
RA Polyiso Insulation
EnergyGuard'
RH Polyiso Insulation
EnergyGuard'
RH Tapered Polyiso
Insulation
Test Product
Specification Description
Proprietary Low VOC, water -based fire barrier
coating.
TAS 139 Solvent -based elastomeric sealant.
ASTM D226 Non -asphaltic fiberglass -based
underlayment and !or fire barrier.
ASTM D146,
Non -asphaltic, fire resistant fiberglass
D828, D4869,
underlayment
D6757
ASTM D3019
Fiber reinforced rubberized cold -applied
adhesive for modified bitumen roof
systems.
Table 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
EnergyGuardT'4 RN Polyiso Insulation
Polyisocyanurate foam insulation
EnergyGuard' Perlite Recover Board
Perlite recover board
EnergyGuard' Perlite Roof Insulation
Perlite insulation board
EnergyGuard'" RA Composite Polyiso
Polyisocyanurate foam insulation
Insulation
with high density fiberboard or
permalite
Structodek' High Density Fiberboard Roof
High density fiberboard
Insulation
SECUROCKI Gypsum -Fiber Roof Board
Gypsum board
SECUROCKO Glass -Mat Roof Board
Gypsum board
DensDeck' Roof Board
Gypsum board
DensDeck® Prime Roof Board
Gypsum board
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
Blue Ridge Fiberboard, Inc.
United States Gypsum Corp.
United States Gypsum Corp.
Georgia-Pacific
Georgia-Pacific
NOA No.: 18-0919.12
Expiration Date; 1110023
Approval Date: 1110VIS
Page 5 of 67
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1.
Drill-Tec' #12 Fastener
Phillips head, modified
#12 x 8"
GAF
buttress thread, pinch
Max. Length
point, carbon steel fastener
#3 Phillips
for use in steel or wood
head.
decks. With CR-10
coating. Available with a
pinch point or drill point.
2.
Drill-Tec' #14 Fastener
Truss head, self -drilling,
#14 x 16"
GAF
pinch point, high thread
Max. Length
fastener for use in steel,
#3 Phillips
wood or concrete decks.
head.
3.
Drill-Tec' XHD Fastener
Truss head, self -drilling,
#15 x 16"
GAF
pinch point, high thread
Max. Length
fastener for use in wood or
#3 Phillips
steel decks. Carbon steel
head.
extra heavy duty fastener
used in steel decks.
4.
Drill -Ted" 3" Steel Plate
Round Galvalurne® steel
3" Round
GAF
stress plate with
reinforcing ribs and
recessed for use with Drill-
Tec" fasteners.
5.
Drill-Tec' 3" Standard
Galvalumee coated steel
3" Round
GAF
Steel Plate
stress plate for use with
approved Drill-Tec"
fasteners.
6.
Drill-Tect" ASAP 3S
Drill-Tec' #12 fastener
#12 x 8"
GAF
with Drill-Tec' 3"
Max. Length
Standard Steel Plate.
#3 Phillips
head with 3"
Round plate
7.
Drill-Tec' AccuTrac®Flat
A2-SS aluminized steel
3" square;
GAF
Plate
plate for use with Drill-
.017" thick
Tee' fasteners.
8.
Drill-Tec' AccuTrace
Galvalume steel plate
3" square;
GAF
Recessed Plate
with recess for use with
.017" thick.
Drill-Tec' fasteners.
9.
Drill -Tee 3 in. Ribbed
Round Galvalumeoplated
3" Round
GAF
Galvalume Plate (Flat)
steel stress plate with
reinforcing ribs for use
with Drill-Tec' fasteners.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/19
Page 6 of 67
EVIDENCE SUBMITTED:
Test Ageacv Teat Identifier ftscriptlon Date
FM Approvals
3001276
FMRC 4470
01/28/99
3010215
FMRC 4470
03/01/01
3029832
FMRC 4470
05/11/07
3036980
FMRC 4470
08/14/09
3034312
FMRC 4470
04/09/09
3040738
FMRC 4470
05/18/12
3042887
FMRC 4470
11 / 14/ 11
3046081
FMRC 4470
02/13/13
3043633
FMRC 4470
01/20/12
1 B9A8.AM
FMRC 4470
09/04/97
3B9QLAM
FMRC 4470
01/08/09
3D4Q2.AM
FMRC 4470
04/30/97
OD1A8.AM
FMRC 4470
04/01/98
797-03221-267
FMRC 4470
09/24/07
797-10228-267
FMRC 4470
01/15/15
797-04694-267
FMRC 4470
06/17/09
797-03825-267
FMRC 4470
07/14/08
RR203450
FMRC 4470
12/04/15
FM Letter
FMRC 4470
04/11/13
FM Letter
FMRC 4470
09/15/15
UL LLC
It 1306
UL 790
08/21 / 18
IRT-ARCON Inc.
02-005
TAS 1144
07/19/04
02.014
TAS 114-3
04/08/02
Trinity ERD
C8500SC.11.07
ASTM D6862
11/30/07
G30250.02.10.2
ASTM D6222
11/11/10
G30250.02,10-3-R2
ASTM D3909
06/03/15
G31360.03,10
ASTM D6164
03/31/10
G32520.06.11
ASTM 131876
06/28/11
G33470.01.11
ASTM D6164
01/13/1)
G34140.04.11-2
ASTM 136163
04/25/11
G34140.04.11-4-R2
ASTM D4601
6/4/2015
G34140.04.11-5-113
ASTM D4897
6/4/2015
G36780.07.1 I-Rl
TAS 114-J
07/18/11
G40620.07.12-2
ASTM D6222
07/17/12
G40630.01.14.1
ASTM D6163
01/06/14
G40630.01.14-2A
ASTM D5147
01/07/14
G40630.01.14-2A-1-R I
ASTM D6164
04/10/14
G40630.01.14-213-R1
ASTM D6164
01/16/15
G40630.01.14-2C
ASTM D6164
01/07/14
040630.03.14
ASTM D5147
03/06/14
G43190,03,14-1
ASTM D5147
03/06/14
G43190.03.14-2
ASTM D5147
03/06/14
G43190.05.14-R1
ASTM D5147
05/20/14
G43610.01.14
ASTM D5147
01/22/14
NOA No.: 16-0919.12
Eipiratlon Date: 11/06/23
Approval Date: 11/01/18
Page 7 of 67
EVIDENCE SUBMITTED: (CONTINUED)
Test A¢eo
Teat Identifier
Description
Date
Trinity ERD
043190.1 I.13-1
ASTM D6222
11/15/13
G46160.02.15
ASTM D6163
02/12/15
G46160.02.15-2D-1
ASTM D6163
02/09/16
G46160.03.15
ASTM D6163
03/11/13
G46160.09.14-2A
ASTM D5147
09/09/14
G46160.09.14-3A
ASTM D6164
09/09/14
G46160.09.14-3B
ASTM D6164
09/09/14
G46160.09.14-3C
ASTM D5147
09/09/14
G46160.12.14.3E
ASTM D6164
12/29/14
G6850.08.08
ASTM D6163
08/01/08
G6850.08.08-R1
ASTM D6164
04/14/11
G6850.10.08
ASTM D6222
10/06/08
G6850.11.08
ASTM D6222
02/17/09
SC6870A8,14-R1
ASTM D3909
09/04/14
PRI Construction Materials
GAF-122-02-01
TAS 139
05/07/06
Technologies, LLC
GAF-245.02-01
ASTM D6083
06/10/10
GAF-276-02-OlRev
ASTM E2178
01/04/11
ASTM D6083
GAF-306-02-01
ASTM E96
07/07/11
GAF-314-02-01
ASTM D2178
08/23/11
GAF-315-02.01
ASTM D2178
08/23/11
GAF-369-02-01
ASTM C1289
10/22/12
GAF434-02-03
TAS 1144
09/06/13
GAF434-02-04
TAS 114-J
09/06/13
GAF464-02-01
ASTM C 1289
02/06/14
CAF498-02-01
ASTM D6093
09/16/16
GAF499-02.01
ASTM D6083
03/12/14
GAF-500-02-01
ASTM D6083
03/12/14
GAF-559-02-01
TAS 117(B)
09/30/14
GAF-559-02-04
ASTM D1976
10/01/14
GAF-559-02-05
ASTM D1876
10/15/14
GAF-559-02-06
TAS 114(H)
10/02/14
GAF-559-02-07
ASTM D903
10/02/14
GAR-559-02-08
ASTM D903
10/02/14
GAF-559-02-09
ASTM D903
IOIOV14
GAF-559-02-11
TAS 114-J
10/14/14
GAF-559-02-12
TAS 1144
10/14/14
GAF-559-02-13
TAS 114-J
10/15/14
GAF-559-02-14
TAS 114-J
10/15/14
GAF-559.02-15
TAS 114-J
10/15/14
GAF-559.02-16
TAS 114-J
10/15/14
GAF-559-02-18
TAS 114-J
10/15/14
GAF-559-02-19
TAS 114-J
04/16/15
Dynatech Engineering Corporation
#4482.02.95-1
TAS 114-C
09/01/95
is
NOA No.: 18-0919.12
r Expiration Date: 11/06/23
Approval Date: 11/01/16
Pace 8 of 67
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS4 Pty 4 and GAFGLAS" F1exPly, 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum %," DensDecka Roof Board or 'A" Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one a1 each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be, less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(Whets this limitation is specifically referred within this NOA, General Limitation t#9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation ##7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 67 of 67
'Y2gr1Gt4 T3p1J.# t700 • UL Flask! Spa
Dealt: C•15132 Inclhte: 112
469nller Soefd (4pllonal): — One or more layers minknum 194n. Oft ownweaft
Gypsum LLC Vin Roo1xwd" or "DenaDWO Prime Rodbosrd' or `DeneD8dW
DuraGusrd"' Pmf xwd" or minimum 1144n. thick United Stiles Gypsum Co. "SECUROCK®
Roof Beard" (Type FRX-0) or lWoUROC 0 Ohms -Met Roof Board' (Typo SGMRX).
lnsandw ( • - One or more layers portite or t ft or or 314in. minimum or
or unMano or urate oomposfte or perlitelurellum
composlte or phenolic,1.1/2 In. minimum.
Bess elad: — One or more plies Type 02 IM MARtor `Trl4My8 #75
Baas Sleet" or "GWGLASB 980 UltimoTM Baas Sheol' or GLASS St aloventO Nailabie
Venting Base Sg1mheet'-tom > mq Performed Venting Base Sheet" m nWly
— g or rrrore piles Type G1 ` M ��1G�: or wTH4 0 Ply 4` or
'OAfOLASS Flex Ply S` or °Trl-PI 0 U Ply V thi mofln saphalt.
Noftmsbfane:—'IMEROID9 t ` Qt "RU 1D®Mop t Oren a or
TUBElB0ue ran FW fully
--'GAi= Flbered Afundfwm MeW�ofl.11�12gaMICW)A.2
./
In*I : 112
Bonkr Naomi (Optional): —One or mare layers mWmwn 114-in. Ift Geosgla-Padllo
Gypsum LLC Mend)&M Rcot*wt' or' wJ* Pflme Roofboard" or`DwmNc O
Duraauafd"' RooPooard' at minimum 1/4- . thick United Steles Gypsum Co. MECUROGKM
Roof Board' (Type FRX-G) or "SECUROCK® Gkw4 W Roof Beard' (Type SOMRX).
Itwletion (OPUDR Ij: — Paine or 1Tbar glass or peiyisocyanurats or urethane or
perIft/polylsocyanuraft compoa te.
Swe $had: — One or more layers Type G 2 "GAFGLASSS NY6 Base Sheet' or `fi1*" #76
Bars SfoW or'GAFG ASO000 UNimare Baas Sheet" or `GAFOLASS Stretawer n Ndisbie
Venting Baas short' or "GAFGLASO Strsta,rerriS PenforeW VeNft ease Sheet" or Type G3
*QAFOt A81B Were! Surged Cap Sheet" or "Tft•PIy® MR granule Cap Sint" mechaftegy
fastened or fully adhered wHh hot roofing asphalt.
Ply IsChW (OpbmaQ: -- One or n plies Type G1 VAFGLASO Ply4" or'Tri4" Ply 4" or
'GAFGLASS Flax Ply r or 701-Ply Uhm-Faxlbk Ply e' fully adhered with hot roofing asphalt,
Wembrute: — "RUSEROMO Mop Granule FR' or "RUSER0100 Mop Plus Granule FR' or
`RUBEROtDD ErwgyCap= Mop Phis Gmnufe FRO fully adhered with hot rooltng asphalt.
11. Deck: C-16132 lndlne: 112
Barter Owd (Opeonal): — One or mere layers minimum 114-in. lift GeorpWADe c;
Gypsum LLC'DensDecW Roofboard" or Mon*DftW Prime Rooiboard" or'Danst?eoWS
DuraGuerd"' RoDboand" or mMlmwn 1144n. thick United States Gypsum Co. 'SECUROCK41)
Roof Boat" (Type FRX-0) at "SECUROCKQP Olass-Mat Roaf Board" (Type SGMRX).
InstdgMen (Optional): — Poriite or fiber glass or polyisocyanu ate or urethane or
Pertitelpalylsoc Wrote composite, butt joints offset a m1ohmm of Bah. *W plywood dsdk
joints.
Dow Sheol+ — one or more plies Type G2 "GAFOLASO 075 Base Sheet` or "Tfi-P" #75
Base Sheet" or *GAFOILASO 060 UttMtralw gees Sheet" or `WOLAS S SbobventS Nallable
Venting Base Sheol` or'GAFGLASO Strataven* Perbrated Venllrtg Base Sheet' or Type G3
are4uaap.e.w.aa�wootm,.�f.php�taFu.Rtaae