Loading...
HomeMy WebLinkAbout10851 S OCEAN DR INS CERTICYNENE® ' Mafm (LD-C-50Q) m Complying with ICC-ES REPORT 1826* a [[���\\\ THE EVOLUTION OF INSULATION This form must be filled out and posted to comply with building code requirements. Meets IRC requirements: 2006 IRC - N1101.2, N1101.4, N1101.8 2009 IRC - N1101.2, N 1101.4, NI 101.8 2012 IRC - N7101.3, N1101.7, N1101.12 Please consult International Building Code (IBC), Chapter 26- Plastic and International Residential Code (IRC) 2006 IRC R314, 2009 IRC R316, 2012 IRC R316 - Foam Plastics for specific requirements. The aforementioned Icynene spray polyurethane foam insulation system(s) has/have been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of:: f Area Insulated Nam" Aged R-Value Thickness* Attic Area* L- ) A- ct- - Sloped Ceilings Walls (location): Walls (location): Floors (over an unheated crawl space) Crawl Space Perimeter Basement Walls Other (location): R- ® at j • inches R- at inches R- [::== at inches R- at inches R- at inches R- at inches R- at inches R- at inches Nominal thicknesses are representative of field, spray -applied foam material. Jobsite Address Date of Insulatior Building Contract Insulation Contra( Insulation Contra( Installed By INSULATION CERTIFICATE • ®O NOT REMOVE Please post near electrical panel. * The foam plastic has been installed in accordance with the terms of Section 4.4.2.2 of ESR-1 826, and that any alterations to the attic must be consistent with those requirements. JM Climate Pro' Fiber Glass Blowing Wool Your home has been professionally insulated to provide superior thermal resistance. °I CI Homeowner's Name v. '\[ Addre55 n1 In K 0. City State Zip J O' IRECOR® OF INSTAL!L%7I70N BLOWING WOOL New Construction 0 ❑ Retrofit Number of bags used Area Insulated v Thickness of Insulation 9-value of Insulation :i If Aetroft: Depth of Previous Insulation Estimated A -value of Previous Installation sq. ft. Types of Previous Insulation in Attic in. in. ClMATE PRO INS U11tZ (](M 5L 6 WEIGHT — 23e . LIL MINIMUM v } i. 0 0; �I O v: 0' �'X ns <> r v, x O`. 0 J Date j A /,--) 1 I'.2 f BATTS AND ROLLS R-VALUE THICKNESS AREA INSULATED Ceilings in. sq. ft. q Walls ( S Floors � -y r�lJ in, sq. ft. s Z in. sl-- sq. fT. in. J W sq. ft / tl in. -rh.a-b 1 pO q- ftd�. ru �' 4— &a n'xr R-VALUE (hr•sq.ft.•°F/BTU) MINIMUM INSTALLED THICKNESS (in.) SETTLED THICKNESS (in] . ,. BAGS PER 900DSUFL MAXIMUM NET COVERAGE (sq.ff./hag) MINIMUM WEIGHT (Ibs./sgJt.) To obtain an insulation Installed insulation Expected thickness Minimum number of Contents of this bag The weight per sq. ft. resistance (R) of should not be less after long-term settling bags per 1,000 sq.ft. should not cover of installed insulation than: has accured of net area: more than: should not be less than: 11 4.3 4.3 4.8 209 0.150 13 5.0 5.0 5.7 176 0.179 19 7.2 7.2 8A 118 0.266 22 8.3 8.3 9.9 101 0.310 26 9.7 9.7 11.8 85 0.371 30 11.1 11,1 13.7 73 0.432 38 13.8 13.8 17.7 56 C.559 44 15.7 15.7 20.8 48 0.656 49 17.3 17.3 23.5 43 0.739 60 20.7 20.7 29.5 34 0.928 I See reverse to determine adjustment in coverage for Chmate Pro Insulation installed in �i �i Insulation Contractor Sii 0 Company 1CL V ` A: dome Builder Signature O Company 7 v X v, J ; 0 re Address 1017 jo-honis Manville Date /a Z Date Phone Far more information, call 1.800-654-3103, BIC-162 4/13 © 2013 Johns Manville. 71717th Street, Denver, CD 80202