HomeMy WebLinkAboutFL2569_R23_II_2021_07_29_FINAL_ER_SOPREMA_HVHZ_FL2569-R23 RegulationBusiness & Professional
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
b
a
r (4-a Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL2569-R23
SECRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL2569 R23 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/29/2021
Date Validated 08/03/2021
Date Pending FBC Approval 08/09/2021
Date Approved 10/12/2021
Date Revised 02/04/2022
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Underlayments for Self adhering roof underlayments
use in FBC HVHZ jurisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL2569 R23 II 2021 07 29 FINAL ER SOPREMA HVHZ FL2569-
Approved for use outside HVHZ: No R23.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA HVHZ FL2569-
R23.pdf
Created by Independent Third Party: Yes
2569.2 Soprema Roof Underlayments for Self adhering roof underlayments
use in FBC non-HVHZ jurisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R23 II 2021 07 29 FINAL ER SOPREMA NON-
Approved for use outside HVHZ:Yes HVHZ FL2569-R23.pdf
Impact Resistant: N/A Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) Evaluation Reports
The design pressure noted herein pertains to FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA NON-
underlayment systems used beneath tile roof systems. HVHZ FL2569-R23.pdf
Refer to ER Section 5.8.3 for details. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ILI FIN Kid E
Credit Gard
Safe
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
fo (203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION •
SOPREMA, Inc. Evaluation Report 3m-SOPC-2I-FBCER.A-RI
1640 rue Haggerty FL2569-R23 (HVHZ)
Drummondville, Quebec J2C 5P8 Canada Date of Issuance:04/19/2021
(819)478-2400 Revision 1:07/29/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity
Hurricane Zone sections noted herein.
DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: ... -
Robert J.M. Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen,P.E.
Florida Registration No.59166,Florida DCA ANE1983 :.=+?e.,,,,,, on 07/29/2021. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEMO ETC,LLC
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: SOPREMA Roof Underlayments,as produced by SOPREMA,Inc., have demonstrated compliance with
the following sections of the 7t' Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions
of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
TAS 110 Material standard ASTM D1970 2015
TAS 110 Material standard ASTM D4601 2012
TAS 110 Material standard TAS 103 2020
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) TAS 103(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018
NEMO(TST6049) ASTM D4601(MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019
NEMO(TST6049) ASTM D4601(OH) 4q-SOP-I9-SSMBB-01.6 03/11/2019
NEMO(TST6049) ASTM D4798/1)1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021
NEMO(TST6049) ASTM D1970(MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
NEMO Traceability FBC Cross-Listing 07/28/2021
UL,LLC(QUA9625) Quality Control MLA File No. R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No. R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
PRODUCT4. DESCRIPTION:
Product Material Standard Plant(s) Description
4.1 LASTOBOND TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS
TAS 103 modified bitumen roof underlayment
4.2 SRS TopShield DEFENDER TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS
FRSA/TRI 09-18 modified bitumen roof underlayment
4.3 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS
Underlayment TAS 103 modified bitumen roof underlayment
4.4 LASTOBOND Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment available in two widths;36 and
45 inch
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 2 of 7
ONEMOletc.
4. PRODUCT DESCRIPTION:
Product Material Standard Plant(s) Description
4.5 RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment
4.6 LASTOBOND Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof underlayment
4.7 LASTOBOND Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment available in two widths;36 and
45 inch
4.8 LASTOBOND Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof underlayment
4.9 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof underlayment
4.10 LASTOBOND Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.11 LASTOBOND Smooth Seal HT ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Wadsworth,OH modified bitumen roof underlayment
4.12 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Underlayment Wadsworth,OH modified bitumen roof underlayment
4.13 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Smooth Seal HT Wadsworth,OH modified bitumen roof underlayment
4.14 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.15 TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Underlayment Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.16 PrimeSource Grip-Rite Eave ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
&Valley Protector Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.17 SRS TopShield ICE&WATER ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
DEFENDER Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.18 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.19 MODIFIED SOPRA-G ASTM D4601,Type II Gulfport,MS Fiberglass reinforced,SBS modified asphaltic base sheet
Wadsworth,OH
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC Non-High Velocity Hurricane Zone jurisdictions(i.e.,outside of Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 3 of 7
NNEMOletc.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: TAS 110(S10), TAS 110(S11), RAS 133 TAS 110(511) RAS 130
RAS 115 RAS 118,119&120
Clay and Concrete Tile
Underlayment Shingles Asphalt Mechanical Adhesive- Metal Slate or Slate-
Underlayment Shingles Wood
Attach Set
LASTOBOND TU HT,SRS TopShield Yes
DEFENDER TU,Tri-Built S/A HT TU Yes Yes Yes Yes Yes
Underlayment See 5.6.1
LASTOBOND Shield, Pro HT-N,RESISTO SA
Yes No No Yes Yes Yes
SMOOTH PLY 40
LASTOBOND Shield HT,Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
LASTOBOND ECO,RESISTO LB1236,TRI-
BUILT Sand-R SA Shingle Underlayment,
Grip-Rite Eave&Valley Protector, Yes No No No Yes Yes
TopShield ICE&WATER DEFENDER,
RESISTO LB1244
LASTOBOND Smooth Seal HT,Tri-Built
Smooth HT S/A Underlayment,Grip-Rite Yes No No Yes Yes Yes
Smooth Seal HT
5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment Adhesive Florida Product Approval
LASTOBOND TU HT,SRS TopShield DEFENDER Dupont"Tile Bond'"Roof Tile Adhesive" FL22525
TU,Tri-Built S/A HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" NOA 20-1124.07
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 4 of 7
ONEMOjetc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
LASTOBOND Shield, LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete
RESISTO SA SMOOTH PLY 40,LASTOBOND Dens Deck Prime or SECU ROCK
Shield HT,LASTOBOND Pro HT-S, Insulation (Optional)Elastocol Stick Zero
Gypsum-Fiber Roof Board
EnviroShield,LASTOBOND TU HT,SRS
TopShield DEFENDER TU,Tri-Built S/A HT TU
Underlayment, LASTOBOND ECO,RESISTO self-
LB1236,TRI-BUILT Sand-R SA Shingle adhering
Underlayment,Grip-Rite Eave&Valley Base Sheet (Optional)Elastocol Stick Zero ASTM D226,Type II felt
Protector,TopShield ICE&WATER
DEFENDER,RESISTO LB1244, LASTOBOND
Smooth Seal HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite Smooth Seal HT
LASTOBOND TU HT,SRS TopShield DEFENDER
TU,Tri-Built S/A HT TU Underlayment,
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle self- Existing Existing sand-surfaced,glass-fiber
RESISTO EXTERIOR PRIMER surfaced,mineral surfaced or
Underlayment,Grip-Rite Eave&Valley adhering substrate ment*
Protector or TopShield ICE&WATER film surfaced roof underlay
DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact
RESISTO technical support.
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
LASTOBOND Eco, RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Mechanically attached 30
Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244
LASTOBOND Shield, LASTOBOND Pro HT-N,RESISTO SA SMOOTH PLY 40,LASTOBOND Shield
HT,LASTOBOND Pro HT-S,EnviroShield,LASTOBOND Smooth Seal HT,Tri-Built Smooth HT Mechanically attached 90
S/A Underlayment or Grip-Rite Smooth Seal HT
LASTOBOND TU HT,SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment Mechanically attached or 180
adhesive-set tile roof system
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 5 of 7
ONEMOletc.
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max. 10-tile stack 6:12
Lugged Max. 10-tile stack 5:12
Double-tile stacking method,as shown below 6:12
LASTOBOND TU HT,
SRS TopShield
DEFENDER TU,Tri-Built
S/A HT TU Lugged
Underlayment
6. •
6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 Approved Assemblies:
6.3.1 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment, self-adhering
and back-nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 6 of 7
ONEMOjetc.
6.3.2 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT,
LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT
TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip-Rite
Smooth Seal HT,self-adhering.
Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate-type shingles, wood
shakes or wood shingles.
6.3.3 Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND ECO,RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley
Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244,self-adhering.
Surfacing: FBC HVHZ Approved asphalt shingles,slate,slate-type shingles,wood shakes or wood shingles.
7. BUILDING PERMIT •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (414)248-6409; Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A-R1
Certificate of Authorization#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R23(HVHZ)
SOPREMA Roof Underlayments Revision 1:07/29/2021
Page 7 of 7