Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 13969 CEDRO
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT. PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Typa�1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4A 1224.00 ft' b.Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d.NIA R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1783.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned Floor area above grade(112) 1753 b.Knee Wall(Vented) R=19.0 30.00 112 Conditioned Floor area below grade(ft2) 0 c.NIA R= ft2 7. Windows(151.4 sgft.) Description Area 12.Ducts R ft2 a. U-Factor: Sgl,U=1.02 111.3$ft2 a.Sup:Attic,Ref:Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEERA5.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14.Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.285 a.Electric Heat Pump 34.8 HSPF:8,50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15.Hot water systems SHGC(AVG): NIA a.Electric Cap:40 gallons 9. Floor Types (1753.0 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. NIA R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 I hereby certify that the plans and specifications covered by Review of the plans and 't-IfI,EB�AT this calculation are in compliance with the Florida Energy specifications covered by this �p Code. calculation indicates compliance with the Florida Energy Code. 1. PREPARED BY: Before construction is completed DATE: 1-12-2021 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. 'lp� OWNEW E BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(111402A.1.2). 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,Stale,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDR00 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 __-_ 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 __- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 __-_ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft2 ___ 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 It 0 36 ft2 ---- 0 1 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 it 0 180 ft2 ---- 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 It 0 588 ft2 _--_ 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN lift 0 209 ft2 --__ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 _--- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 it 0 25 ft2 --__ 0 1 0 11Sleb-On-Grade Edge Insulatio FOYER 9 it 0 92 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 it 0 169 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area - Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 112 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood _ 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood _ 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood _ 8 Under Attic(Vented) KITCHEN 30 Blown 209 112 0.1 Wood _ 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood _ 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 1? 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall(Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 NE=>SW Exterior Concrete Block-Int InsWASTER BE 4.1 16 0 8 0 128.0 fl2 0 0 0.3 0 _ 2 SW=>NE Exterior Concrete Block-Int InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Int InsWASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FSC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ft In Ft in Arse Ahq�r _ 4 NE=>SW Exterior Concrete Block-Int InsMASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 _ 5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block-Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 SW=>NE Exterior Concrete Block-Int Ins(DINING/GRE 4.1 30 0 8 0 240.0 ft- 0 0 0.3 0 _ 8 NW=>SE Exterior Concrete Block-Int InsaINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 _ 9 SW=>NE Exterior Concrete Block-Int InsuIKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 SE=>NW Exterior Concrete Block-Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 _12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft- 0 0 0.3 0 13 NE=>SW Exterior Concrete Block-Int Ins9EDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 SW=>NE Exterior Concrete Block-Int InsElEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 i ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Until Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 195 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: ��N [[ ]] Ceiling Fans: Julr[`X]lJCS X� (r Nov Heating L 1 Jan [)n Feb [)n Mar Apr Ma A ay y Jun l l Jul [ ]ADec ug 4 ]Sep Oct [ Nov Dec Venting [ 1 Jan II 11 Feb IIX�I Mar Jun I Jul I 1 Aug I 1 Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 76 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 76 78 78 78 78 78 Cooling(WEH) PM 78 78 7 78 78 8 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M.BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(81bs/sq.ft. ft2 it 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. n= ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default 8 Ibs/s .ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable Insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barter. Rim joists shall be insulated. Floors The air barter shall be installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided Instead of floor Insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Baits in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed In the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall -extend behind piping and wiring Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft' b.Frame-Wood,Adjacent R=11.0 208.00 ft' 3. Number of units, if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft' 6. Conditioned floor area(ft') 1753 b.Knee Wall(Vented) R=19.0 30.00 ft' 7. Windows" Description Area c.N/A R= ft' a. U-Factor: Sgl,U=1.02 111.36 ft2 12.Ducts,location&Insulation level R ft' SHGC: SHGC=0.29 a.Sup:Attic,Ret:Attic,AH:Attic 6 195 b. U-Factor: Sill,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficlency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14.Heating systems kBlu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area - 15.Hot water systems Cap:40 gallons a. U-FactogAVG): N/A ft2 a.Electric EF:0.97 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft' 1 certify that this home has complied with the Florida Energy Efficiency Code for Building E S Construction through the above energy saving features which will be installed(or exceeded) yO�gtt9r�o in this home before final inspection. Otherwise, a new EPL Display Card will be completed y , % �� 0 based on Installed Code compliant features. ) ar Builder Signature: " �- -. Date: Address of New Home: \30.k,06k C a City/FL Zip: � ��RS *�0 eta 0 WF *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 a Project Summary Job: wrightsofk Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Phone:772466-6799 Fax 772-46M796 Email:QUICKCALCS@A01-.00M Proilect Information For: WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Notes: Design Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Insidedb 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Btuh Duds 9337 Btuh Central vent(0 dim) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 27734 Btuh Use manufacturers data In Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(fi) 1753 1753 Equipment latent load 5041 Btuh VOIUme(13) 16478 16478 Airchanggesmour 0.38 0.20 Equipment Total Load(Sen+Lat) 29511 Bfuh EquivAVF(cfm) 104 55 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536AO30 Cond 25HBC536AO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Effldency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @47-F Latentcooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfin Actual airflow 1160 cfm Airflowfador 0.042 cfm/Btuh Airflowfador 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capadty balance point=36 OF Backup: Input=7kW, Output=23009 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigtit$oft- 2021-Jan1213:18:18 •W PogR-SWAUriversa1201919.021 RSU08101 Pagel ACCK ..Ao.rrs\Wrigftaft FNAC\WYNNE-THEWINDSORnp Calc=M18 Frord Doorhams:N +�+wrightsoft- Right-J®Worksheet Job: Entire House Data: QUICK CALCS, INC. sy 317 ST.LUCIE UN.,Fr.PIERCE,FL 34946 PInre:772466.6799 Fax T7246"796 Email:QUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM 2 Dposedxall 207.6 ft 41.0 It 3 Room height 9.4 ft d 9.4 ft heattool 4 Roomdimensons 14.0 x 20.0 ft 5 Room area 1753.0 W 280.0 tie Ty Construction U-value Or HTM Area O) Load Area (ft) Load number (BWhtV-'F) (BWhflP) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross N/PS Heat Coal Gross NIPS Heat Cool 6 UI/ 13A-0as 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 IL-GG 1Acian 1270 n 35.56 34.77 15 0 533 522 0 0 0 '0 4A5-2om 0.770 n 21.56 19.31 38 0 815 730 0 0 0 0 W 13A-4ocs 0.143 ne 4.00 2.55 27 27 106 68 0 0 0 0 11 h}/ 13A-0as 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 VL--G 1Acian 1270 a 35.56 87.06 20 1 711 1741 0 0 0 0 D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 Q 0 W 13A4o 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 W 13A4as 0.143 s 4.00 2.55 536 530 2121 1349 188 188 753 479 -G 1Ac1am 1270 s 35.56 34.77 6 6 213 209 0 0 0 0 V)/ 13A-4= 0.143 w 4.00 2.55 320 255 102.2 649 132 108 432 275 Lam{--GGG 1Ao1an 1270 w 35.56 54.53 12 1 415 636 12 1 415 636 1Aclom 1270 w 35.56 54.53 12 1 427 654 12 1 427 654 4A5.2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Oex 0.091 - 255 128 254 254 647 326 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 1753 1753 1671 4067 280 280 251 650 F 22A-tpl 0.989 - 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AEDe=rsion 397 488 Envelope loWgain 183311 15285 1 36761 3349 12 a) Infiliaton 3211 905 729 205 b) Roomventlation 0 0 - 0 0 13 Intemalgalns: Ooupanls@ 230 1 230 0 0 Appliancea0lher 0 0 Subtotal(lines 6to 13) 21542 16420 4405 3554 Lessebemalload 0 0 0 0 Lesstrensfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 21542 16420 4405 3554 15 Duct loads 29% 57% 6191 9337 29% 57% 12661 2021 Total room bad 27734 25767 5671 5575 Airrequlre0(dm) 1160 1160 237 251 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrl bias�R"�A '""^""�"•^"'^^O"'""" Ri9R-Sule6»lhiversa1201979021 RSU08101 2021-Jan1213n8:18 .,.Dow rds\WngHwft HVAC\WYNNE-THEWINDSOR.np Calc=MJB Front Doorlams:N Paget wrightsoft° Right-J®Worksheet Job: Entire House Date: By.QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Pl ne:772466-6799 Faz 772466-6796 EmaiI:OUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 FVwseUoall 0 4 9.0 ft 3 Room height 9.4 ft heaVmol 9.4 It heaVOxl 4 Room dimensions 7.0 x 9.0 ft 7.0 x 9D ft 5 Room area 63.0 ft' 63.0 fP Ty Con lructon U-value Or HTM Area (ft') Load Area (ft.) Load number (BWhtP--'F) (Bah/') or perimeter (ft) (Bah) or perimeter (t) (BWh) Heat Cool Gross NIPrS Heat Cool Gross WPIS Heat Cool 6 V�1 13A4o s 0.143 n 4.00 2.55 0 0 0 0 0 0 - 0 0 - G 1Ac1w 1270 n 35.56 34.77 0 0 0 0 0 0 0 - 0 L-G 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ors 0.143 % 4.00 2.55 0 0 0 0 0 0 0 0 13A-4ars 0.143 5 4.00 2.55 0 0 0 0 85 85 339 - 215 G 1Ac1= 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 1q/ 13A4as 1270 w 5.56 2.53 0 0 0 0 0 0 0 0 III-�GGi 1Acian 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Ac1om 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Css 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 27A-tpl 0.989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AEDerrunion -10 -28 Envelopeloss/gain 56 136 1 6441 334 12 a) Infil7aton 0 0 160 45 b) Roomeentlation 0 0 0 0 13 Internal gains: Omrpants@ 230 0 0 0 0 Applianoes/other 0 0 Subtoal(lines6to 13) 56 136 804 379 Less edemal load 0 0 0 0 Lesstansfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 56 136 804 379 15 Ductloads 29% 57% 16 771 29% 57-%j 231 216 Total room load 73 214 1036 595 Alr required(cfm) 3 10 43 27 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rw w�19bt>9o1R' 2021-Jan1213:18:18 Aft Rigft.SUteOLhi erml201919.021 RSU08101 Page t ...Doamerts\Wdglbot HUAC\WYNNE-THEWINDSORnp CaIc=MJB Frord Doorfaces:N +� wrightsoft• Right-M Worksheet Jot: Entire House Date: By QUICK CALCS, INC. 317 SL LUCIE LN„FT.PIERCE,FL 34946 Kom 772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOLCOM 1 Room name Nt BATH KITCHEN 2 Fpowdmll 8.0 8 8A fl 3 Room helght 9A It heaVcool 9.4 It heaVcool 4 Room dimensions 7.0 x 8.0 8 1A x 172.0 It 5 Room area 56.0 K 172.0 IF Ty Consmx8on U-value Or HTM Area (F) Load Area (fM Load number (Bhrh4P--T) (ftw) or pedmear (R) (BWh) or perimeter M (BWh) Heat Cool Gross NfPS Heat Cool Gross NrP/S Heat Cool 6 Vtl M4oa 0.143 n :4A0 - 2.55 0 0 0 - 0 0 0 0 0 L�CG '1Actom 1270 n 35.56 34.77 0 0 0 0- - 0 - 0 ;0 - 0 05-20m 0.7.70 n 2156 1931 - 0 0 -0 0 . 0 0 0: 0: W 13A-4oro 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 % j 13A4oa _ 0.143 a 4.00 255 0` 0 0 - 0 0- 0 0 0 II----DG 1Aclm 1276 a 35,56 87.06 0 0 0 0 0 0 -0 0 11DO 0.390 a 1022 - 11.31 0 . 0 0 0 - 0 - 0 0 -0 W 13A-4om 0.143 as 4.00 2S5 0 0 0 0 0 0 0 0 1344ocs- - - 0.143 a 4.00 - 2.55 - 75- -69 277 - 176 0 0 0 '.0 �G 1"11M 1270 a 3556 3477 6 6 213 209 0 0 0 =0 W 13A-0as III 12 w 4A0 2.55 0 0 0 0 0 0 0 0---GGG 1Acli m 1270 w 3 .56 5 .53 0 0 0 0 0 0 0 0 1Actam 1270 w 36.56 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12G-Ow 0A91 2.55 128 0 0 0 0 75 75 192 96 C 16A30md OA32 - 0.90 2.32 56 56 50 130 172 172 164 399 F 22A-tpl 0.989- - 27.89 0.00 56' 8 222 - 0 - 172 8 - 222 0 6 c)AEDe>mrsIw -38 -34 Ervelopelosalgein 762 477 567 462 12 a) Infilhafion 142 40 0 0 b) Roomtenlilalion 0 0 0 0 13 Ill gams: Oowpanls@ 230 0 0 0 0 AppliancesIodw 0 0 SubMtal(llw603) 1 904 517 567 462 Lewexemallead 0 0 0 0 Lesstranskr 0 0 0 0 Redistribution 0 0 0 0 14 SU 904 517 567 462 15 Ductloads 29% 57% 260 294 29% 57%1 163 263 Tolal room load 1164 811 730 725 Airrequlred(clim) 037 31 33 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. d -�}F•wr! berofC• - �Ac '�'•'"`^""" R1gltSdte®Unverm1201919.021 RSU08101 2021Jao-1213:18:18P e3 ...Doa dslWdg%oAHJAQWYNNE-THEWINDSOR.np Calc=WB FrortWorfaws:N wrightsoft• Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. ey 317 ST LUCIE UN,Fr.PIERCE,FL 34946 Phone:772-466.6799 Fax 772-066-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 Exposedvall 5.0 ft 42.6 ft 3 Room height 9A ft heaticool 9A ft heatbool 4 Room dimensions 9.0 x 5.0 It 1.0 x 204,0 ft 5 Room area 45.0 fl' 204.0 P Ty Construction U-value Or HTM Area (it) Load Area Load number (BI It'-°F) (BNhM') or perimeter (ft) (BWh) or perimeter (ft) atuh) Heat Ccol Grow NAPrS Heat Cool Gross NIPS Heat Cool 6 13A-0as 0.143 n 4.00 2.55 47 47 188 120 132 132 527 335 1Ac1cm 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0. 0 W 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 27 27 106 68 11 W 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 85 65 259 164 IL-CD tAotan 1270 a 35.56 87.06 0 0 0 0 20 1 711 1741 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 - 0 0 W 13A-4= 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 13A-4= 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 G 1Aoicm 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4(cs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 120-Osv 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0.989 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AEDexawion -17 -99 Envelope loWgain 367 207 13599 3085 12 a) Infilbafion 89 25 758 214 b) Roomvenfilation 0 0 0 0 13 Intemal gains: Oowpanls@ 230 0 0 0 0 ApplianoWother 0 0 Subtotal(lines 6 to 13) 456 232 4357 3299 Lew external load 0 0 0 0 Lewtransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Ductloads 29% 57% 131 132 29% 57% 1252 1876 Total room load 587 364 5W9 5175 Airrequired(dm) 25 16 235 233 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �}+- wrt96isoft- 20214ao-1213:18:18 Right-SueOUnversel 201919.021 RSU08101 Page ...Doa rtslWnghtsoft HVAC\WVNNE-THEWINDSOR.rnp Calc=M18 Frcnl Norfaces:N + wrightsoft, Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. ey. 317 ST.LUCIE LN,Fr.PIERCE,FL 34946 Pmre:772466.6799 Fax 772-466-6796 Eorail:QUICKCALCS@AOLCOM 1 Room name ENTRY LAUNDRY 2 Eposedmll 18.0 ft 13.0 it 3 Room height 9.4 ft heaVmol 9A It heatrmol 4 Room dimenslom 1.0 x 92.0 ft 7.0 x 6.0 It 5 Room area 92.0 IF 42.0 iP Ty Construction U-value Or HTM Area gle) Load Area gle) Load number (BWhW--°F) (BWh4F) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NJPr9 Heat Cool Gross N/P5 Heat Cool 6 Vt/ 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 L�GC 1Ac1w 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 IA5.2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A4oce 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13AA<xs 0.143 a 4.00 2.55 56 35 142 90 0 0 0 0 1Aaclw 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 �D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-0as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A4ccs 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 1Ww 1270 a 35.56 34.77 0 0 0 0 0 0 - 0- 0 13AAo 0.143 w 4.00 2.65 0 0 0 0 0 0 0 0 1A,c1w 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1Aclw 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 2.55 128 113 113 287 145 66 66 168 84 C 16A-30md 0.032 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A.tpl 0.989 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AED exnrrson 49 -24 Envelope lardgaln 1239 637 17911 301 12 a) Infiltraton 107 30 107 30 b) Roomw:ntlatfon 0 0 0 0 13 Inlemal gains: Ooorpanls@ 230 0 0 0 0 ApplianoeNother 0 0 Subtotal(lines 6W 13) 1346 667 898 331 Leas external load 0 0 0 0 Less transfer 0 0 0 0 Redishibuton 0 0 0 0 14 Subbtal 1346 667 898 331 15 Dud loads 29% 57% 387 379 29% 57% 268 188 Total room load 1733 1047 1156 520 Airrequired(dm) 72 47 1 48 23 �."� Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -•- wrt9ti>�of!^ 2021-JarN 213:18:18 �A RigH-Su WD Uriversal 201919.021 RSU08101 Page ...Dow rts\WdgMntrHUAC1WYNNE-THEWINDSOR.n4) Calc=MJ8 Frort Doorfdces:N wrightsoft° Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax M466-6796 Email:QUICKCALCS@AOL.COM 1 Room name GREAT/DINING Room? 2 5posaduall 50.0 ft 13.0 ft 3 Room height 9A ft heatkool 9.4 it heaVolol 4 Room dimensions 1.0 x 567.D ft 13.0 x 13.0 ft 5 Room area 567.0 ft' 169.0 ft° Ty Construction U-value or HTM Area OF) Load Area (ft') Load number (BahAf--°F) (BWhAY) or perimeter (ft) (Bah) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Groas NIPS Heat Cool 6 V 134-0as 0.143 n 4.00 2.55 282 244 978 622 122 107 429 273 I�-CC 1Ac1an 1270 n 35.56 34.77 0 0 0 0 15 0 533 - 522 4A5.2om 0.770 n 21.56 1931 38 0 815 730 0 0 0 0 W 13A-0as 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 V// 13A-4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 I__GG 1AcIcm 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 - 0 W 13A-0as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A 4o s 0.143 a 4.00 2.55 0 0 0 0 0 0 0 '0 L-C 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13AA4 0.143 w 4.00 2.55 188 147 589 375 0 0 0 0 1Aclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1AoIom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 567 567 508 1315 169 169 151 392 F 22A-tpl 0,989 - 27.69 0.00 567 50 1385 0 169 13 360 0 6 c)AEDemursion 307 -100 Envelopeloss/gain 5154 5210 14741 1086 12 a) Infiltratlon 889 251 231 65 b) Roomeentlafion 0 0 0 0 13 Internal gains: Oaupants@ 230 0 0 1 230 Appliancesiolher 0 0 Subtoal(lines6to 13) 6043 5461 1705 1381 LesseAsmal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribufion 0 0 0 0 14 Subtotal 6043 5461 1705 1381 15 Ductloads 29% 57% 1737 3105 291/6 57% 490 785 Total room bad 7780 8566 2195 2167 Airrequlred(ttm) 325 386 92 98 Calculafions approved byACCAto meet all requirements of Manual J 8th Ed. -'}d-wrlaft s - 2021-Jan-1213:18:18 A ^-� Riglt-Sdte®Udverml201919.021RSU08101 Page ...Doumer&WdgHsoft HVAC1WYNNE-THE WINDSORnp Calc=MJB FroitDoor ares:N Duct System Summary Job: wrightsoft$ y ry Date: Entire House By, QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Pt*w 772-466.6799 Fax 772466.6796 Email:QUICKCALGS@1OL.CDM Project Information For: WYNNE DEVELOPMENT THE WINDSOR,FT.PIERCE,FL Heating Cooling Extemal static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/retumavailable pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowestfriclion rate 0 in/10011 0 in/100ft Actual airflow 1160 cfm 1160 clrrl Total effective length(TEL) 0 ft SupplyDetail Table Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfn) (dm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH h 364 25 16 0 0 Ox0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 OxO ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OxO ShMt 0 0 BEDROOM-A c 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREAT/DINING C 2855 108 129 0 0 OxO ShMt 0 0 GREAT/DINING-A C 2855 108 129 0 0 Ox 0 ShMt 0 0 GREAT/DINING-B C 2855 108 129 0 0 OxO ShMt 0 0 KITCHEN C 725 31 33 0 0 OxO ShMt 0 0 LAUNDRY h 520 48 23 0 0 OxO ShMt 0 0 M.BATH h 811 49 37 0 0 OxO ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Room7 C 2167 92 98 0 0 OXO ShMt 0 0 WIC c 214 3 10 0 0 0x0 ShMt 0 0 DetailReturn Branch Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (Cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 1 ShMt -0 11- wrightsoR' 2021-dao-1213d8:19 .+,..-, •,.»-.,.>.,.., Right-SUtefnversa1201919.021 RSU08101 Page 1 ...DIa rfs\WrigHsoft HVAC\WYNNE-THE WINDSORrtp Colo=M18 Frort Door%ces:N