Loading...
HomeMy WebLinkAboutAPPROVED, Gess Generator Specs20/22/24 kW INCLUDES: • True Power" Electrical Technology • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/PoOuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fig connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled for installation as close as 18 in (457 mm) to a structure.` 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when it's needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA M131-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC� GUARDIANS SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz G007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz G007209-0, G007210-1 (Aluminum - Bisque) - 24 kW 60 Hz GENERAC c \III us or CLISTEDUS QU ry uN Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. GENERAC lei w ,, O a GENERAC" 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution— Controls • AUTO/MANUAt10FF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. 20/22/24 kW Generator Model Rated maximum continuous power capacity (LP) Rated maximum continuous power capacity (NG) Rated voltage Rated maximum continuous load current — 240 volts (LP/NG) Total Harmonic Distortion Main line circuit breaker Phase Number of rotor poles Rated AC frequency Power factor Battery requirement (not included) Unit weight (lb / kg) Dimensions (L x W x H) in / cm Sound output in dB(A) at 23 tt (7 m) with generator operating at normal load" Sound output in dB(A) at 23 it (7 m) with generator in Quiet -Test'" low -speed exercise mode" Exercise duration GENERAC Specifications G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) 20,000 Watts' 22.000 Watts' 20,000 Watts" 22,000 Watts` 24,000 Watts' 18,000 Watts' 19.500 Watts" 18.000 Watts' 19,500 Watts` 21,000 Watts' 240 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 Less than 5% 90 amp 100 amp 90 amp 100 amp 100 amp 1 2 60 Hz 1.0 12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum 448 / 203 466 / 211 436 / 198 445 / 202 455 / 206 48 x 25 x 29 / 121.9 x 63.5 x 73.7 67 67 67 67 67 55 57 55 57 57 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/ cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx. 1.9 qt / 1.8 L Operating rpm 3,600 Fuel consumption Natural gas iW/hr (m3/hr) 1/2 Load 204 (5.78) 228 (6.46) 164 (4.64) 203 (5.75) Full Load 301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66) Liquid propane ON (gal/hr) (Uhrl 1/2 Load 87 (2.37) [8,991 92 (2.53) [9.571 86 (2.36) (8.951 92 (2.53) [9.571 Full Load 130 (3.56) [13,481 142 (3.90) [74.771 136 (3.74) [14.151 142 (3.90) [14.771 Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2,49-2.99 kPa) for LP gas. For BTU content, multiply hs/hr x 2500 (LP) or tta/hr x 1000 (NG). For Megajoule content, multiply m1/hr x 93.15 (LP) or m3/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable (brownout setting) From 140-171 V/ 190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/AlarrrUMaintenance logs 50 events each Engine start sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Faull/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faup/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard "'Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 fl (304.8 m) above sea level; and also will decrease approximately 1%for each 10 °F (6 °C) above 60 °F (16'C). GENERAC9 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features G007039-1, 0007039-3 (20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model G007043-2, G007043-3 (22 kW) G007210-1 (24 kW) • Up to eight additional large (240 VAC) loads can be managed when used in conjunction No. of poles 2 with Smart Management Modules (SMMs). Current rating (amps) 200 • Electrically operated, mechanically -held contacts for fast, clean connections. Voltage rating (VAC) 120/240,10 • Main breakers are rated for 80% continuous load. utility voltage monitor (fixed)' -Pick-up 80 % • 2-pale, 250 VAC contactors. -Dropout 65% • Service equipment rated, dual coil design. Return to Utility` Approx.13 sec Eor Ue listed Standard • Rated for both aluminum and copper conductors. Enclosure losure type NEMANL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MGM- #6 *Function of Evolution controller Dimensions Exercise can be set to weekly, bi-weekly, or monthly 200 Amps 120/240, 1e Open Transition Service Rated Height Width Depth Hi H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 W, H2 H, i L DEPTH � 112 GENERAC' 20/22/24 kW Available Accessories Model # Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 OF (-18 °C). (Not nec- essary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if temperature regularly falls below 0 OF (-18 °C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed. Not compatible with 50 amp pre -wired switches. G007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the Monitor LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0 - 413 LTE Mobile Link`"' Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using G007170-0 - Wi-Fi/ Accessories a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us - Ethernet ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. G007220-0 - Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This offers a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit contains four plugs, sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 G007209-0 696471071511 G007210-1 696471084801 72' [2 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G E N E RAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2021 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000937814 Rev. D 04/14/2021 J�N 1z r, Cy 1 +� u DnERsiTe!Piol 800.888.2069 www.genpads.com A Solid Foundation for You and Your Customers The new GenPadTI is the answer for dealers who need a professional looking pad that will provide a lifetime base for their Generac"I home backup generator installations. Each GenPad is made from a composite of high strength fibers and cement and is warranted for the life of the generator. These pads provide a sturdy, permanent base with a professional appearance for the generator. Give your customers even more peace of mind with their Generac generator purchase when you add the reliable GenPad. GenPads are much lighter weight than a poured concrete pad and take less time and effort to install. GenPads are made specifically to fit Generac 8-22kw home standby units. GenPads were specifically designed to meet the engineering specifications of Generac units. All GenPads are purchased directly from Generac and include these features: • Extremely Impact and Breakage Resistant • Fiber reinforced concrete that is further reinforced with rebar • Flat bottom to facilitate easy leveling of the pad and generator • Virtually eliminates sinking of the unit into the ground • Easy to install • 1/2 the weight of poured concrete • Meets national gas code NFPA 37 Two models GenPad TM GenPad Hurricane TM Designed for residential installation. Thicker, heavier 4" pad designed to meet wind load requirements in hurricane prone areas. GenPad Program Available in pallets of 2, 5 or 10 - volume discounts available Dealers and distributors: Call today for pricing: 800-888-2069 GenPads are now available in pallet quantities of ten, five and two! GenPads are the answer for dealers who want a professional looking pad that provides a lifetime base for Generac home standby generators. • Pallets of ten pads can be mixed with both sizes (ex: quantity 8 OJ5339 and quantity 2 OJ5340 to make up one pallet of ten). Due to weight limitations, all shipments of 100 or more pads in multiple sizes will be reviewed by Generac prior to shipment. 3" GenPad Information Generac ..Lescription OK4678 54" X 31 " x 3" Weight perPod 189 .. per 2 OK0033 54" X 31 " x 3" 189 5 OJ5339 54" X 31 " x 3" 189 10 4" GenPad Hurricane Information Generac Part Number _J& Description OK4679 54" x 31 " x 4" Weight perPad 275 .. per Pallet 1 2 OK0034 54" x 31 " x 4" 275 5 OJ5340 54" x 31 " x 4" 275 10 FAQ: ®: Is the GenPad approved by Generac for use with its generators? A: The GenPad is not only approved by Generac, but is only available for purchase from Generac! ®: Why would I want to install a GenPad under a Generac unit? A: The GenPad provides a solid, sturdy foundation for all 8-22 KW Generac produced generators and eliminates the risk of uneven mounting surfaces. Many local area codes may also require a concrete base for the generator. The GenPad also provides extra height off the ground for the generator. A: Can I install my Generac generator on the GenPad without removing the black composite mounfing pad? A: Yes, by leaving the black composite mounting pad attached to the generator with the back two bolts and by removing the front two bolts. Place the generator, with the black composite mounting pad in place, on top of the already placed and leveled GenPad. Align the bolt holes of any 8-22 KW Generac produced generator with the inserts in the GenPad and attach together by using 3" long 3/8" bolts. Installing with the black composite pad between the generator and GenPad also elevates the generator so that the plastic fascia (standard with 20kw and available in kits for other sizes) can be used. A: What do I need to put underneath the GenPad? A: The GenPad can be placed directly onto leveled ground. There is no need to place anything below it to provide a stable platform with professional appearance. A: Why should I sell my customers a GenPad? A: The GenPad provides a sturdy base for the Generac generator and helps protect it and keep it level to maximize its performance and life. The GenPad is faster and easier to install than pouring a concrete pad and makes an excellent accessory add -on when selling a new generator. A: Where is the GenPad Hurricane used? A: The 4-inch GenPad Hurricane is a heavier, thicker pad that is ideal for high wind zone areas: Florida, the Gulf Coast and the Tidewater region. They are also used for installations that require more ground clearance. To view the wind load tables please visit: genpods.com/resources.htm/ A: If I have product related questions whom can I contact? A: Please contact DiversiTech via email genpads@diversitech.com or call 1-800-888-2069 Other info: Warranted for the life of the generator (through DiversiTech), 25% recycled material. Rebar reinforced. GenPad Features Benefit to Dealer Benefit to Installer Real Value Lightweight Easy to Stock Easy to Install, Saves Cost saves time Precision Fewer callbacks Easy to Install Saves Cost Produced Aesthetically Adds value to Better installation Adds to resale Pleasing purchase value Production Saves Saves Saves Cost Product installation time/ installation time/ trips to job site trips to job site Flat bottom Reduces/ Simple and quick Reduces/ Eliminates return to install Eliminates trips calling dealer to return and level the generator