Loading...
HomeMy WebLinkAboutENERGY CACLS & MANUAL J - 17 INDIGO FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type41442.0 sqft.) Insulation Area 2. Single family or multiple family Detached a•Concrete Block-Int Insul,Exterior R=4.1 1250.00 ft2 b. Frame-Wood,Adjacent R=11.0 192.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 2 d.NIA R= ft2 5. Is this a worst Case? Yes 11.Ceiling Types (1504.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade(ft2) 1474 b.Knee Wall(Vented) R=19.0 30,00 ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 7. Windows(141.3 sgft.) Description Area 12.Ducts R ft2 a. U-Fac#or: Sgl,U=1.04 101.25 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.29 b. U-Factor: SgI,U=1.11 40.00 ft2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14.Heating systems kBfulhr Efficiency Area Weighted Average SHGC: 0.284 a.Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG). NIA a.Electric Cap:50 gallons 9. Floor Types (1473.5 sgft.) insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b.N/A R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0A96 Total Proposed Modified Loads: 44.66 PASS Total Baseline Loads: 45.56 hereby certify that the plans and specifications covered by Review of the plans and VEST this calculation are in compliance with the Florida Energy specifications covered by this p Code. calculation indicates compliance with the Florida Energy Code. t* rrr�y . �.. ,: ,•,� O PREPARED BY: Before construction is completed DATE: 1-13-2D this building will be inspected for compliance with Section 553.908 * �, 1 hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy C�de w 0 OWNE G� '�� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/13/2021 8:02 AM EnergyGaugeQ USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5 FORM R405.2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infli ID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 329 ft' ---- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC t ft 0 63 ft' ---- 0 1 0 3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft' ---- 0 1 0 4 Slab-On-Grade Edge Insulatio KITCHEN i ft 0 192 W --_- 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' -.-- 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 it 0 203.5 fV ---- 0 1 0 7 Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ---- 0 1 0 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Entitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall(Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block-Int Insi6EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block-Int Insr6EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 3 NW=>SEExterior Concrete Block-Int lnsuBEDRO0M 4.1 14 0 8 0 112.0ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block-Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block-Int InsENEDROOM 2 4.1 16 0 8 0 128.0 112 0 0 0.4 0 7 SE=>NW Exterior Concrete Block-Int lnsBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block-Int InsS'EDROOM 2 4.1 4 3 8 0 34.0 ill 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block-Int Ins0EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ill 0 0 0.4 0 11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 112 0 0 0.4 0 12 SW=>NE Exterior Concrete Block-Int InsuLAUNDRY 4.1 6 0 8 0 48.0 112 0 0 0.4 0 _13 NE=>SW Exterior Concrete Block-Int lnstOREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block-Int InstGREAT/DINT 4.1 20 0 8 0 160.0 f12 0 0 0.4 0 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => charxied to Worst Case. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.04 0.29 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 0 In 1 ft 5 In None None 3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 N 24.0 ft' 6 ft 0 in 1 ft 5 in None None 4 NE=>SW 13 Metal Low-E Single Yes 1.04 0.29 N 37.5 ft' 1 ft 0 in 1 ft 5 in None None 5 NW=>SE14 Metal Low-E Single Yes 1.11 0.27 N 40.0 V 8 ft 0 in 1 ft 5ln Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.48 141.7 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.6 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UniU Split Sing] SEER: 15 34.8 kBtu/hr ofm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None f(2 DUCTS _ / ---Supply---- ---Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 125 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans:Cooling Jan Feb Mar [X] XJ X� rfX�l Nov Dec Venting Jan Feb Mar Apr [ MM:yay Jun [ ]Jul 4 ]Aug 4 ]Sep Oct [X)Nov € Dec Jun ( ]Jul [ ]Aug I[ 1)Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Healing(WD) PM 68 68 68 6 68 8 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. oft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 It 0.3 WIC Default(8lbs/sq.ft, ft2 It 0.3 M.BATH Default(8 lbs/sq.ft. ft' It 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 It 0.3 BATH Default(81bs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(S lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s .ft. ft2 ft 0.3 GREAT/DINING 1/13/2021 8:02 AM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 •AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City,Slate,Zip: FT.PIERCE,FL, Permit Number: U Owner: Jurisdiction: w x Design Location: FL,Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air baffler. not be used as a sealing material. q Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The Insulation in any dropped celling/sofit the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air baffler. Access openings,drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor docking,or floor framing cavit y insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,Insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall i. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Balls in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on Installation readily conforms to available space shall extend behind niping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire qnrnkllt' ' a.In addition,Inspection of log walls shall be in accordance vrith the provisions of ICC-400. 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index,the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Well Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Adjacent R=11.0 192.00 ft- 3. Number of units, if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1474.00 ft2 6. Conditioned floor area(ft2) 1474 b.Knee Wall(Vented) R=19.0 30.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Sgl,U=1.04 101.25 ft2 12.Ducts,location&insulation level R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a.Electric Heat Pump 34.8 HSPF:8.0 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15.Hot water systems 2 a.Electric Cap:50 gallons a. U-Factor(AVG): N/A ft. EF:0.97 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1473.50 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building E S Construction through the above energy saving features which will be installed (or exceeded) yoFZB ==rATF 3,o in this home before final inspection. Otherwise, a new EPL Display Card will be completed '= 'p .* based on installed Code compliant Builder Signature: Date: ��� 1` Q A Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7lh Edition(2020) Compliant Software Page 1 of 1 wrightsoftPro ect Summa Job: rY Entire House Date: a• Jan 13,2021 QUICK CALCS, INC. 317 ST.LUCIE I-N.,Fr.PIERCE,FL 34946 Prore:772-466-6799 Fax:772A66-6796 Email:OUICKCALCS AOL.COM Proiect Information For: WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Notes: Design • • Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18852 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfin) 0 Btuh Central vent(0 ckn) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24506 Btuh Use manufacturers data In Rate/swingg multipplier 0.95 Infiltration Equipmentsensibleload 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent(0 cirn) 0 Btuh Heatingg Coolingg (none) Area(ftt) 1M 1474 Equipment latent load 5277 Btuh Volume(ft) 12227 12227 Airchan��22es/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 30370 Btuh Equiv.AN(cfm) 92 47 Req.total capadty at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carver Make Carder Trade CARRIERAIRCONDITIONING Trade CARRIERAIRCONDITIONING Model 25HBC636XO30 Cond 25HBG536KO30 AHRlref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latent000ling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfin Actual air flow 1160 cfm Airflowfactor 0.047 cfm/Btuh Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=33 OF Backup: Input=7kW, Output=23009 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htaoft° 2021-Jan1308:11.06 ^• •^ -w^-+•^^»* Rigtt-Sdb�&Unversa1201919.021 RSU08101 Page 1 ...0umris\WrigI*ofl HADWYNNE-THE STERLING.rip Calc=M18 Frort Door Faces:N wrightsoft` Right-JO Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 PInre:772-466-6799 Fax 772-466-6795 Email:QUICKCALCS@AOL.00M 1 Room name Entire House MASTER BEDROOM 2 EVosedvali 1802 ft 52.0 ft 3 Room height 8.3 it d 8.0 ft heaYood 4 Room dimensions 5 Room area 14735 fl' 3290 P 1.0 x 329.0 ft Ty Conahuchon U-value Or HTM Area number (BWhtP--°F) (BWh&) or perimeter (it) Load orsperimeter Load (ft) (BWh) Heat Cool Gross NIPS Heal Cool Gross NrPrS Heal Cool 6 V" t 13A-0as 0.143 ne 4.00 2.55 479 442 1768 1124 80 80 320 204 Aclom 1270 ne 35.56 70.43 38 0 1344 2662 0 0 0 0 13A4o 0.143 se 4.00 2.55 128 83 331 210 0 0 0 0 1Aclom 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11 rs D0 0.390 se 1022 11.31 22 22 236 244 0 0 0 0 W 13A-4= 0.143 a 4.00 2.55 34 34 136 86 0 0 0 0 vrl 13A-4ocs 0.143 sv 4.00 2.55 360 353 1414 899 224 224 897 570 �G 1Aclom 1270 sw 35.56 42.91 7 5 247 298 0 0 0 0 13AAoce 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 G 1Aclom 1270 nw 35.56 4524 33 0 1162 1478 33 0 1162 1478 4A5-2om 0.770 nw 21.56 27.54 41 0 880 1124 0 0 0 0 P 12C-Ow 0.091 2.55 128 192 192 489 246 0 0 0 0 C 16A„30md 0.032 - 0.90 2.32 1474 1474 132C 3419 329 329 295 763 F 22A-tDI 0.989 - 27.69 0.00 1474 18C 4989 0 329 52 1440 0 6 c)AED ewursion 784 680 Envelope loss/galn 16030 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Roomeentlation 0 0 0 0 13 Internal gains: Omrpans@ 230 5 1150 2 460 Applian�olher 2000 0 Subtotal(lines6to 13) 18352 17877 5341 4606 LesseMemal load 0 0 Lesstranser 0 0 0 0 Redlsbibufion 0 0 0 0 14 Subtotal 18852 17877 0 6 5341 4606 15 Ductloads 30% 411 5654 85M 30% 48% 1602 2199 Total room load 24506 26413 6943 6805 Air required(dm) 1160 1160 329 299 Calculabons approved byACCA to meet all requirements of Manual J 8th Ed -PWwrlgtirsoTe- 1'. RigIt-Sule®Unversa1201919.021 RSU08101 2027-Jan1308:11:08 ...oamerts\WnghboRWACIWYNNE-THESTERLING nq Calc=M18 Frort DDorfaces:N Page wrightsoft` Right-J@ Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST LUCIE LIN,Fr.PIERCE,FL 34946 P1ore:772466-6799 Fax:772466.6796 Email QUICKCALCS@AOL.COM 1 Roomname WIC MBATH 3 R height 8.0 ft O fl heaVbool 8.0 It 8.0 It heaV=l 4 Room dimendons 7.0 x 9.0 t 7.0 x 8.0 A 5 Room area 63.0 ft2 56.0 T Ty Construction U-value Or HTM km OF) Load number (BWhAtL-F) (BWh/F or (et Load Area ) perimeter (fl) (BWh) or perimeter (fl) (BWh Heat Cool Gross NIP/5 Heat Cool Gross NA�Ai Heat Cool 6 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 1Aclon 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A-4 s 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 se 3556 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-0as 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A4ocs 0.143 sv 4.00 2.55 0 0 0 0 64 57 228 145 G 1Aciom 1270 sw 35.56 42.91 0 0 0 0 7 5 247 298 VN 13A4c s 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 I�-GG 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4P5.2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 255 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 5( 146 56 56 50 130 F 22A-tDI 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED excursion -2 225 Envelopelossrgain 56 146 747 798 12 a) Infillraton 0 0 140 38 b) Roommantllation 0 0 0 0 13 Internal gains: Omlpanls@ 230 0 0 0 0 Appliances'other 0 0 Subtotal(lines 6to 13) 56 145 887 836 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 838 15 Ductloads 30% 48% 17 69 30% 48% 2661 399 Total room load 73 214 1153 1235 Alr required(cm) 3 9 55 54 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. -Pfd-wrl M,ft- 2021-Jan1308:11:08 AAA �"" RigH-Sute®Um,erml 201919.021 RSUD8101 Page...ocunerts\Wnghtsot HVAC\WYNNE-THE STERLING.rup Calc=We Frort Door faces:N 9 + wrightsoft• Right-J@ Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 PI-one:772-466-6799 Fax 77246"796 Email:QUICKCALCS @(?AOLCOM 1 Room name KITCHEN BATH 2 ElooSedwall 8.0 ft 5.0 ft 3 Room height 8.0 ft heaVcool 8.0 ft heaVrool 4 Room dimensions 1.0 x 192.0 ft 9A x 5.0 It 5 Room area 1910 V 48.0 re Ty Construction U-value or HTM Area (ft2) Load Area (M Load number (BWhXR`o (BWW) or perimeter (ft) (Stuh) or perimeter (ft) (BWh) Heat Cool Gross N/prS Heat Cool Gross NRIS Heat Cool 6 W " 13A-0as 0.143 no 4.00 2.55 0 0 0 0 40 40 160 102 �G 1Actan 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 13A4o s 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 \')1 13A4m 0.143 sN 4.00 2.55 0 0 0 0 0 0 0 0 L-G 1Aclom 1270 sv 35.56 42.91 0 0 0 0 0 0 0 0 13A4os 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 G 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12"m 0.091 2.55 128 64 64 163 82 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 192 192 172 445 45 45 40 104 F 22A-tpl 0.989 - 27.69 0.00 192 8 222 0 45 5 1311 0 6 c)AED emrsion -27 -2 Emelopelo-dgain 557 501 339 204 12 a) Infiltra0'on 0 0 87 24 b) Roomventilalion 0 0 0 0 13 Intemalgains: Ocupants@ 230 0 0 0 0 Applianoesrother 2000 0 Subtotal(littes 6to 13) 557 2501 426 228 Lesse>demal load 0 0 0 0 Lesstranskr 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 557 2501 426 228 15 Dud loads 30% 48% 167 1194 30% 48% 128 109 Total room load 724 3695 554 336 Airrequired(dm) 34 162 26 15 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -/}d- wrlgft so " 2021-Jarf1308:11.06 Aft -' -' Rglt-Sdte*Uriwrwl20l9l9.021RSU08101 Page ...oamerls\WrigHSORHVAC\WYNNE-THE STERLING np CaIc=W8 Frort Doorfaces:N wrightsofr Right-M Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phow:772.466-6799 Fax:772466,6796 Emil:QUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 Extoosedxall 322 It 16.0 It 3 Room height 8.0 It heaVcool 8.0 It huVo3d 4 Room dimensions 1.0 x 203.5 It 1.0 x 55.0 It 5 Room area 203.5 ft 55.0 T Ty Construction U-value Or HTM Area (ft') Load Area (T) Load number (BWtdft'--'F) (BWh/l or perimeter (8) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross NrP/S Heat Cool Gross N/P/S Heat Cool 6 N/ 13AAM 0.143 ne 4.00 2.55 128 128 513 326 0 0 0 0 �G 1Ac1an 1270 re 35.56 70.43 0 0 0 0 0 0 0 0 13A-4ars 0.143 w 4.00 2,55 80 56 225 143 48 26 106 67 1Acian 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 w 13A-0as 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 13A4acs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 G 1Aclom 1270 sv 35.56 42.91 0 0 0 0 0 0 0 0 13A4ocs 0A43 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5.2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-09v 0.091 2.55 128 0 0 0 0 72 72 183 92 C 16A30md 0.032 0.90 2.32 204 204 182 472 65 55 49 128 F 22A-tpl 0.989 - 27.69 0.00 204 32 891 0 55 16 443 0 6 c)AED exursion 1 -24 -6 Envelope losrgain 2859 1873 1049 545 12 a) Infilhalon 564 154 122 34 b) Rcomsentlation 0 0 0 0 13 Internal gains: O=pants@ 230 1 230 0 0 Appllanos/other 0 0 Subtotal(fires 6to 13) 3422 2257 1172 579 Less external load 0 0 0 0 Les transfer 0 0 0 0 Redistribution 0 0 0 0 14 lots 3422 2257 1172 579 8%15 Du rt loads 30% 4 1026 1078 30% 48% 351 276 Total room bad 4449 3335 1523 855 Air required(&n) 211 146 72 38 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - -wrt9ft+'t9o�` Rg R sa1201919.021 2021-Jan130891:06 ...oudslWrigMsoflHVAC1W1VNE-THESTELING.rip CaIc=MB FrontDoorfaces:N Page 4 �+ wrightsoft• Right J@ Worksheet Job: Entire House Data: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE UN,Fr.PIERCE,FL 34946 PIpne:772-466.6799 Fax:772466.6796 Email:OUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATIDINING 2 ExPosedwall 13.0 fl 46.0 fi 3 Room height 8.0 a heaV000l 8.9 ft heaV000l 4 Room dimensions 7.0 x 6.0 R 1.0 x 488.0 R 5 Room area 42.0 1R 488.0 T Ty Constructon U-value Or HTM Area IT) Load Area (M2) Load number (BNtJfl2--'F) (Bh1h/P) or perimeter (fl) (BWh) or perimeter (R) (Bluh) Heat Cool Gros; N/P/5 Heat Cool Gross NIPS Heat Cool 6 W, 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 231 194 T75 493 �G 1Aclom 1270 ne 35,56 70.43 0 0 0 0 38 0 1344 2662 13A4as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4= 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A4ws 0.143 sw 4.00 2.55 48 48 192 122 0 0 0 0 G 1Actom 1270 sa 35.56 42.91 0 0 0 0 0 0 0 0 13A4ars 0.143 nw 4.00 2.55 0 0 0 0 178 137 549 349 G 1A-clom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 27.64 0 0 0 0 41 0 880 1124 P 12C-Ow 0.091 2.55 128 56 56 143 72 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-fol 0.989 - 27.69 0.00 42 13 360 0 488 46 1274 0 6 c)AEO exaurdon -3 .56 EnvelopebWgain 733 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room en61ation 0 0 0 0 13 Intemalgains: Omlpants@ 230 0 0 2 460 ApplianceWolher 0 0 Subtotal(Ilnes6m 13) 837 317 6154 6409 LesseArnalload 0 0 o p Less tanAr 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 837 317 6154 6409 15 Ductloads 30% 48% 261 151 300/c 48% 1846 31160 Total room load 1089 468 8000 s469 Air required(dm) 52 21 379 416 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -fIF wrigbCsolR' 2021-Jan-1308:111:06 ' RigttSuL0Unvam12019I9.021 RSU08101 Page ...oarrans\WnghL ft HVAC\WYNNE-THESTERLINGnp Calc=MJ8 Front Doorfaws:N wrightsoftDuct System Summary Job: y ry Date: Jan 13,2021 Entire House sY QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Prone:772-466-6799 Fas 772.46"796 Email:QUICKCALCS a,SOL.COM Project Information For: WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.284 in/10011 0.284 in/100ft Actual airflow 1160 cfm 1160 Ctrn Total effective length(TEL) 176 ft SupplyDetail Design Htg Clg Design Diam HxW Duct Actual Ftg.Egv Name (Bill (clm) (dm) FR (in) (in) Mad Ln(ft) Ln(ft) Trunk BATH h 554 26 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM2 h 4449 211 146 0.374 6.0 Ox0 MFx 18.6 115.0 stt ENTRY h 1523 72 38 0.510 5.0 OxO VIFx 3.0 95.0 GREAVDINING c 4735 189 208 0.318 7.0 OxO VIFx 22A 135.0 st2 GREAT/DINING-B C 4735 189 208 0.307 7.0 Ox0 MFx 28.1 135.0 st2 KrrCHEN C 3695 34 162 0.375 7.0 OxO MFx 18.3 115.0 st1 LAUNDRY h 1089 52 21 0.366 6.0 OxO VIFx 21.6 115.0 st1 M.BATH h 1153 55 54 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 MASTERBEDROOMA h 3471 164 149 0.297 6.0 OxO MFx 33.1 135.0 st2 MASTERSEDROOMB h 3471 164 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 INIc c 214 3 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 SupplyDetail Trunk Htg Clg Design Veloc Clam HxW Duct Name Type 0m) (Cim) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 711 724 0.284 922 12.0 0 x 0 VinIFIx sill SO PeakAVF 1088 1122 0.284 1050 14.0 0 x 0 VnlFlx L • 20214ao-1308:11:06 Wrl9h!<SO�L.»t„vft Rigf-Sute0Unverw1201919.D21 RSU08101 Page 1 Arch ...00m WWrighsofi WACOYNNE-THE STERUNG.np Cale=M18 Front Door faces:N Return Branch Detail Table Grille Htg ICIg TEL Design Ueloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 1 VIFx Wr7ghtsoft- 2021-Jan1308:11:06 A .w...•� ..awe....., Ri9kSule@Umersa1201919.021RSU08101 Paget ...oa+n \WnghWftFNAQWYNNE-THESTERLINGw Ca1c=W8 Frort Doorfaces:N