TES Project Number: 114400 Page 1 September 1, 2021
Phone (972) 483-0607, Fax (972) 975-9615
1320 Greenway Drive, Suite 600, Irving, Texas 75038
Structural Analysis Report
Existing 450 ft FWT Guyed Tower
Customer Name: SBA Communications Corp
Customer Site Number: FL04816-A
Customer Site Name: Swain Road Tower
Carrier Name: T-Mobile (App#: 168872, v1)
Carrier Site ID / Name: A2P0044C / SBA SWAIN ROAD
Site Location: 1401 Swain Road
Fort Pierce, Florida
Saint Lucie County
Latitude: 27.435872
Longitude: -80.377549
Analysis Result:
Max Structural Usage: 65.1% [Pass]
Max Foundation Usage: 95.9% [Pass]
Additional Usage Caused by New Mount: +2.60%
Report Prepared By: Walter Velez
TES Project Number: 114400 Page 2 September 1, 2021
Introduction
The purpose of this report is to summarize the analysis results on the 450 ft FWT Guyed Tower to support
the proposed antennas and transmission lines in addition to those currently installed. Any modification
listed under Sources of Information was assumed completed and was included in this analysis.
Sources of Information
Tower Drawings Original structural design report & tower section data prepared by FWT, Inc. Dated 06-11-
1998. Job No 17139. Design No G98-0600, R2.
Previous structural report prepared by Tower Engineering Solutions. Dated 11-08-2016.
TES Project No 27480 Rev1.
Foundation Drawing Original foundation design & foundation geometry prepared by FWT, Inc. Dated 07-17-
1998. Job No 17139. Design No G98-0600, R2.
Geotechnical Report Geotechnical report prepared by FDH Engineering, Inc. Dated 09-18-2012. Project No
1208832EG1.
Modification Drawings N/A
Mount Analysis Antenna mount analysis report prepared by Tower Engineering Solutions. Dated 08-19-
2021. TES Project No 114411.
Analysis Criteria
The comprehensive analysis was performed in accordance with the requirements and stipulations of the
TIA-222-H. In accordance with this standard, the structure was analyzed using TESTowers, a proprietary
analysis software. The program considers the structure as an elastic 3-D model with second-order effects
and temperature effects incorporated in the analysis. The analysis was performed using multiple wind
directions.
Wind Speed Used in the Analysis: 158.0 mph (3-Sec. Gust) (Ultimate wind speed)
Service Load Wind Speed: 60 mph + 0” Radial ice
Standard/Codes: TIA-222-H, 2018 IBC & Florida Building Code, 7th Edition (2020)
Exposure Category: C
Risk Category: II
Topographic Category: 1
Crest Height: 0 ft
Seismic Parameters: SS = 0.050, S1 = 0.028
This structural analysis is based upon the tower being classified as a Risk Category II; however, if a
different classification is required subsequent to the date hereof, the tower classification will be changed
to meet such requirement and a new structural analysis will be run.
TES Project Number: 114400 Page 3 September 1, 2021
Existing Antennas, Mounts and Transmission Lines
The table below summarizes the antennas, mounts and transmission lines that were considered in the
analysis as existing on the tower.
Proposed Carrier’s Final Configuration of Antennas, Mounts and Transmission Lines
Information pertaining to the proposed carrier’s final configuration of antennas and transmission lines
was provided by SBA Communications Corp. The proposed antennas and lines are listed below.
Please see the attached coax layout for the line placement considered in the analysis.
Items Elevation
(ft.) Qty. Antenna Descriptions Mount Type & Qty. Transmission
Lines Owner
1
232.0
6 CellMax CMA-BDHH/6520/E0-8 - Panel
(3) V-Frame
(VF13-XX-96)
(12) 1 5/8";
(1) 1.584"
Hybrid
T-Mobile
2 3 Andrew DBXNH-6565B-A2M - Panel
3 3 Andrew TMA-S-DB1921-DD-A TMA's
4 3 Nokia FHFB RRU
5 3 Nokia FRIJ RRU
6 1 Raycap ASU9338TYP01
7
200.0
6 JMA Wireless X7CQAP-665-V - Panel
(3) Sector Frames (12) 1 5/8" Verizon 8 6 Kaelus TBC0030F1v1
9 6 CSS DBC-7CAP
10 3 Commscope ATSBT-TOP-FM
Items Elevation
(ft.) Qty. Antenna Descriptions Mount Type & Qty. Transmission
Lines Owner
11
232.0
6 CellMax CMA-BDHH/6520/E0-8 - Panel
(3) V-Frame Assembly
(SitePro1 VFA12-HD)
(9) 1 5/8"
Coax;
(1) 1.584"
Hybrid;
(2) 1.996" HCS
Trunk
T-Mobile
12 3 Ericsson FFVV-65C-R3-Vl - Panel
13 3 RFS ATMAA1412D-1A20 TMA's
14 3 Ericsson 4460 RRU's
15 3 Ericsson 4480 RRU's
16 1 Raycap ASU9338TYP01
(RNSNDC-7771-PF-48) DC Surge
TES Project Number: 114400 Page 4 September 1, 2021
Analysis Results
The results of the structural analysis, performed for the wind and ice loading and antenna equipment as
defined above, are summarized as the following:
Tower Component Legs Diagonals Horizontals Guy Wires
Max. Usage: 59.3% 32.5% 65.1% 56.0%
Pass/Fail Pass Pass Pass Pass
Foundations
Base Reactions Inner Anchors Outer Anchors
Reactions (kips) Axial Shear Uplift Shear Uplift Shear
Original Design Reactions 626.9 6.1 181.2 215.5 99.8 86.3
Analysis Reactions 399.9 3.7 106.8 127.0 65.1 58.7
Factored Reactions* 846.3 8.2 244.6 290.9 134.7 116.5
* Per section 15.5.1 of the TIA-222-H standard, factored reactions were obtained by multiplying a 1.35 factor to the original design
reactions.
The foundation has been investigated using the supplied documents and soils report and was found
adequate. Therefore, no modification to the foundat ion will be required.
Operational Condition (Rigidity):
Operational characteristics of the tower are found to be within the limits prescribed by TIA -222 for the
installed antennas. The maximum twist/sway at the elevation of the proposed equipment is 0.0135
degrees under the operational wind speed as specified in the Analysis Criteria.
Conclusions
Based on the analysis results, the existing structure and its foundation were found to be adequate to
safely support the existing and proposed equipment and meet the minimum requirements per the
ANSI/TIA-222-H standards, the 2018 IBC and the Florida Building Code, 7th Edition (2020) under the
design basic wind speed specified in the Analysis Criteria.
TES Project Number: 114400 Page 5 September 1, 2021
Standard Conditions
1. This analysis was performed based on the information supplied to (TES) Tower Engineering Solutions,
LLC. Verification of the information provided was not included in the Scope of Work for TES. The
accuracy of the analysis is dependent on the accuracy of the information provided.
2. The structural analysis was performance based upon the evidence available at the time of this
report. All information provided by the client is considered to be accurate.
3. The analyses will be performed based on the codes as specified by the client or based on the best
knowledge of the engineering staff of TES. In the absence of information to the contrary, all work will
be performed in accordance with the latest relevant revision of ANSI/TIA-222. If wind speed and/or ice
loads are different from the minimum values recommended by the ANSI/TIA-222 standard or other
codes, TES should be notified in writing and the applicable minimum values provided by the client.
4. The configuration of the existing mounts, antennas, coax and other appurtenances were supplied by
the customer for the current structural analysis. TES has not visited the tower site to verify the adequacy
of the information provided. If there is any discrepancy found in the report regarding the existing
conditions, TES should be notified immediately to evaluate the effect of the discrepancy on the analysis
results.
5. The client will assume responsibility for rework associated with the differences in initially provided
information, including tower and foundation information, existing and/or proposed equipment and
transmission lines.
6. If a feasibility analysis was performed, final acceptance of changed conditions shall be based upon a
rigorous structural analysis.
Type:Guyed
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 1
Base Shape:Triangle
Base Width:0.00
Base Elev:0.00 (ft)
Structure: FL04816-A-SBA
Top Width:5.00
Basic WS:158.00
Basic Ice WS:0.00
Operational WS:60.00
Code:EIA/TIA-222-H
Section Properties
Sect Leg Members Diagonal Members Horizontal Members
SOL 3/4" SOLID PLT 4" x 5/8"1 SOL 3 1/4" SOLID
SOL 3/4" SOLID SAE 2.5X2.5X0.18752-6 SOL 3 1/4" SOLID
SOL 7/8" SOLID SAE 2.5X2.5X0.257SOL 3 1/4" SOLID
PLT 2"X1/2"SAE 3X3X0.258SOL 3 1/2" S0LID
SOL 7/8" SOLID SAE 2.5X2.5X0.259-10 SOL 3" SOLID
PLT 2"X5/8"SAE 3X3X0.312511SOL 3 1/4" SOLID
PLT 2"X5/8"SAE 3X3X0.312512SOL 3" SOLID
SOL 3/4" SOLID SAE 2.5X2.5X0.187513SOL 2 3/4" SOLID
PLT 2"X1/2"SAE 3X3X0.2514-15 SOL 2 3/4" SOLID
SOL 5/8" SOLID SAE 2X2X0.2516SOL 2 1/4" SOLID
SOL 7/8" SOLID SAE 2.5X2.5X0.2517-18 SOL 2 1/2" SOLID
SOL 5/8" SOLID SAE 2X2X0.2519-20 SOL 2" SOLID
SOL 3/4" SOLID SAE 2.5X2.5X0.187521SOL 2" SOLID
SOL 5/8" SOLID SAE 2X2X0.2522-23 SOL 2" SOLID
SOL 3/4" SOLID SAE 2.5X2.5X0.187524SOL 2" SOLID
Discrete Appurtenances
Attach
Elev (ft)
Force
Elev (ft)Qty Description
450.00 1 Lightning Rod, 7'453.50
450.00 1 Beacon450.00
377.15 3 Side Lights377.15
256.00 1 Torque Arms256.00
232.00 6 CellMax CMA-BDHH/6520/E0-8232.00
232.00 3 Ericsson FFVV-65C-R3-Vl232.00
232.00 3 RFS ATMAA1412D-1A20 TMA's232.00
232.00 3 Ericsson 4460 RRU's232.00
232.00 3 Ericsson 4480 RRU's232.00
232.00 1 Raycap ASU9338TYP01 (RNSNDC-7771-PF-48)
DC Surge
232.00
232.00 1 (3) V-Frame Assembly (SitePro1 VFA12-HD)232.00
200.00 3 Sector Frames200.00
200.00 6 JMA Wireless X7CQAP-665-V200.00
200.00 6 Kaelus TBC0030F1v1200.00
200.00 6 CSS DBC-7CAP200.00
200.00 3 Commscope ATSBT-TOP-FM200.00
192.00 1 Torque Arms192.00
128.00 1 Torque Arms128.00
114.50 3 Side Lights114.50
Linear Appurtenances
Elev
From (ft)
Elev
To (ft)Qty Description
3.00 232.00 9 1 5/8" Coax
3.00 232.00 1 1.584" Hybrid
3.00 232.00 2 1.996" HCS Trunk
3.00 200.00 12 1 5/8" Coax
Max Guy Wire
55.98% @ 384.075 ft - 7/8 EHS
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
9/1/2021
Page: 2
Structure: FL04816-A-SBA
Type:Guyed
Site Name:Swain Road Tower
Height:450.00 (ft)
Base Shape:Triangle
Base Width:0.00
Base Elev:0.00 (ft)Top Width:5.00
Basic WS:158.00
Basic Ice WS:0.00
Operational WS:60.00
Code:EIA/TIA-222-H
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
9/1/2021
Page: 3
Anchor Drops with Guy Radius - Structure: FL04816-A-SBA
Type:Guyed
Site Name:Swain Road Tower
Height:450.00 (ft)
Base Shape:Triangle
Base Width:0.00
Base Elev:0.00 (ft)Top Width:5.00
Basic WS:158.00
Basic Ice WS:0.00
Operational WS:60.00
Code:EIA_H
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Type:Guyed
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 4
Structure: FL04816-A-SBA - Coax Line Placement
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Loading Summary
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 5
Code:EIA/TIA-222-H
Exposure:C
Gh:0.85
Base Elev:0.000 (ft)
Crest Height:0.00
Site Class:
IIStruct Class:
D - Stiff Soil
Topography:1
Discrete Appurtenances Properties
IceNo Ice
Attach
Elev
(ft)Description Qty
Weight
(lb)
CaAa
(sf)
Weight
(lb)
CaAa
(sf)
Len
(in)
Width
(in)
Vert
Ecc
(ft)
Depth
(in)Ka
Orientation
Factor
Lightning Rod, 7' 1 35.00 1.050 1.73044.00450.00 0.000 0.000 0.000 3.5001.00 1.00
Beacon 1 15.00 2.400 2.40020.00450.00 0.000 0.000 0.000 0.0001.00 1.00
Side Lights 3 3.00 0.200 0.2505.80377.15 8.000 4.000 4.000 0.0001.00 1.00
Torque Arms 1 400.00 8.000 15.000750.00256.00 0.000 0.000 0.000 0.0001.00 1.00
CellMax CMA-BDHH/6520/E0-8 6 62.00 9.050 0.0000.00232.00 64.600 15.900 5.000 0.0000.80 0.70
Ericsson FFVV-65C-R3-Vl 3 183.43 21.110 0.0000.00232.00 95.900 25.200 9.300 0.0000.80 0.72
RFS ATMAA1412D-1A20 TMA's 3 13.00 1.000 0.0000.00232.00 12.000 10.000 4.000 0.0000.80 0.67
Ericsson 4460 RRU's 3 109.00 2.140 0.0000.00232.00 17.000 15.110 11.850 0.0000.80 0.67
Ericsson 4480 RRU's 3 93.00 2.800 0.0000.00232.00 21.800 15.400 7.500 0.0000.80 0.67
Raycap ASU9338TYP01
(RNSNDC-7771-PF-48) DC Surge
1 13.00 1.000 0.0000.00232.00 12.000 10.000 4.000 0.0000.80 0.67
(3) V-Frame Assembly (SitePro1
VFA12-HD)
1 2322.0
0
50.700 70.0502820.00232.00 0.000 0.000 0.000 0.0000.75 1.00
Sector Frames 3 500.00 15.000 20.600650.00200.00 0.000 0.000 0.000 0.0000.75 0.75
JMA Wireless X7CQAP-665-V 6 45.00 9.550 0.0000.00200.00 72.000 14.600 7.100 0.0000.80 0.78
Kaelus TBC0030F1v1 6 11.00 0.650 0.0000.00200.00 9.800 7.900 2.800 0.0000.80 0.67
CSS DBC-7CAP 6 7.00 0.610 0.0000.00200.00 10.480 7.020 1.900 0.0000.80 0.67
Commscope ATSBT-TOP-FM 3 1.76 0.170 0.0000.00200.00 5.630 3.700 2.000 0.0000.80 0.60
Torque Arms 1 400.00 8.000 15.000750.00192.00 0.000 0.000 0.000 0.0001.00 1.00
Torque Arms 1 400.00 8.000 15.000750.00128.00 0.000 0.000 0.000 0.0001.00 1.00
Side Lights 3 3.00 0.200 0.2505.80114.50 8.000 4.000 4.000 0.0001.00 1.00
7,118.80 19Number of Appurtenances : Totals:7,053.5755
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Loading Summary
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 6
Code:EIA/TIA-222-H
Exposure:C
Gh:0.85
Base Elev:0.000 (ft)
Crest Height:0.00
Site Class:
IIStruct Class:
D - Stiff Soil
Topography:1
Linear Appurtenances Properties
Weight
(lb/ft)
Width
(in)
Pct
In
Block
Spread
On
Faces
Bundling
Arrangement
Elev.
From
(ft)Description
Elev.
To
(ft)Qty
Cluster
Dia
(in)
Out
of
Zone
Spacing
(in)
Orientation
Factor
Ka
Override
3.00 232.00 1 5/8" Coax 1.98 50.00 1 Block 9 1.04 N 0.50 1.00
3.00 232.00 1.584" Hybrid 1.58 100.00 1 Individual IR 1 1.00 N 1.00 1.00
3.00 232.00 1.996" HCS Trunk 1.99 50.00 1 Block 2 1.10 N 0.50 1.00
3.00 200.00 1 5/8" Coax 1.98 50.00 2 Block121.04 N 0.50 1.00
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 7IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.2D + 1.0W 158 mph Wind at Normal To Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.20
Ice Importance Factor:1.00
1.2D + 1.0W Normal WindLoad Case:
46.15 0.446 0.00 0.35 2.16 1.00 1 2.0 1.00 0.00 2.64 2.49 0.00 895.1 0.0 223.78 86.90 310.683.49
46.15 3.941 0.00 0.19 2.64 1.00 2 12.0 1.00 0.00 10.71 39.81 0.00 2,604.2 0.0 1111.16 1390.36 2,501.5211.72
53.33 5.911 0.00 0.20 2.61 1.00 3 30.0 1.00 0.00 14.29 49.76 0.00 3,309.9 0.0 1692.04 2008.36 3,700.4014.65
59.38 5.911 0.00 0.20 2.61 1.00 4 50.0 1.00 0.00 14.20 49.76 0.00 3,309.9 0.0 1872.93 2236.38 4,109.3214.65
63.74 5.968 0.00 0.20 2.61 1.00 5 70.0 1.00 0.00 14.20 49.76 0.00 3,309.9 0.0 2008.98 2400.55 4,409.5214.65
67.21 5.911 0.00 0.20 2.61 1.00 6 90.0 1.00 0.00 14.10 49.76 0.00 3,309.9 0.0 2104.17 2530.98 4,635.1514.65
70.11 5.911 0.00 0.20 2.59 1.00 7 110.0 1.00 0.00 14.46 49.76 0.00 3,545.7 0.0 2234.58 2640.19 4,874.7815.28
72.62 14.842 0.00 0.25 2.44 1.00 8 130.0 1.00 0.00 21.20 49.76 0.00 4,091.0 0.0 3188.09 2734.70 5,922.7911.67
74.84 5.938 0.00 0.19 2.62 1.00 9 150.0 1.00 0.00 14.09 49.76 0.00 3,244.7 0.0 2343.89 2818.34 5,162.2314.46
76.83 5.938 0.00 0.19 2.62 1.0010170.0 1.00 0.00 14.07 49.76 0.00 3,244.7 0.0 2402.95 2893.59 5,296.5314.46
78.66 14.898 0.00 0.24 2.46 1.0011190.0 1.00 0.00 20.83 49.76 0.00 4,049.9 0.0 3419.89 2962.14 6,382.0310.83
80.33 17.328 0.00 0.26 2.41 1.0012210.0 1.00 0.00 22.96 25.79 0.00 3,669.1 0.0 3773.62 1552.41 5,326.0310.00
81.88 5.964 0.00 0.18 2.66 1.0013230.0 1.00 0.00 13.30 15.47 0.00 2,312.4 0.0 2462.36 949.46 3,411.8113.01
83.33 15.009 0.00 0.23 2.50 1.0014250.0 1.00 0.00 20.17 0.00 0.00 2,587.9 0.0 3565.17 0.00 3,565.179.17
84.69 17.394 0.00 0.25 2.43 1.0015270.0 1.00 0.00 22.61 0.00 0.00 2,764.3 0.0 3947.98 0.00 3,947.989.17
85.98 4.813 0.00 0.15 2.77 1.0016290.0 1.00 0.00 10.95 0.00 0.00 1,558.2 0.0 2219.15 0.00 2,219.1510.72
87.19 5.990 0.00 0.18 2.66 1.0017310.0 1.00 0.00 13.33 0.00 0.00 2,114.8 0.0 2629.21 0.00 2,629.2112.83
88.35 6.033 0.00 0.18 2.66 1.0018330.0 1.00 0.00 13.36 0.00 0.00 2,114.8 0.0 2669.84 0.00 2,669.8412.83
89.45 4.833 0.00 0.14 2.80 1.0019350.0 1.00 0.00 10.49 0.00 0.00 1,353.7 0.0 2233.18 0.00 2,233.189.90
90.50 4.833 0.00 0.14 2.80 1.0020370.0 1.00 0.00 10.49 0.00 0.00 1,353.7 0.0 2259.46 0.00 2,259.469.90
91.51 6.076 0.00 0.16 2.73 1.0021390.0 1.00 0.00 12.13 0.00 0.00 1,446.0 0.0 2578.31 0.00 2,578.3110.55
92.48 4.833 0.00 0.14 2.80 1.0022410.0 1.00 0.00 10.49 0.00 0.00 1,353.7 0.0 2308.82 0.00 2,308.829.90
93.41 4.833 0.00 0.14 2.80 1.0023430.0 1.00 0.00 10.49 0.00 0.00 1,353.7 0.0 2332.09 0.00 2,332.099.90
94.09 4.063 0.00 0.19 2.65 1.0024445.0 1.00 0.00 7.25 0.00 0.00 799.5 0.0 1533.98 0.00 1,533.985.51
59,696.3 0.0 84,319.97
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 8IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.2D + 1.0W 158 mph Wind at 60° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.20
Ice Importance Factor:1.00
1.2D + 1.0W 60° WindLoad Case:
46.15 0.446 0.00 0.35 2.16 0.80 1 2.0 1.00 0.00 2.55 2.49 0.00 895.1 0.0 216.23 86.90 303.123.49
46.15 3.941 0.00 0.19 2.64 0.80 2 12.0 1.00 0.00 9.92 39.81 0.00 2,604.2 0.0 1029.40 1390.36 2,419.7611.72
53.33 5.911 0.00 0.20 2.61 0.80 3 30.0 1.00 0.00 13.10 49.76 0.00 3,309.9 0.0 1552.01 2008.36 3,560.3714.65
59.38 5.911 0.00 0.20 2.61 0.80 4 50.0 1.00 0.00 13.02 49.76 0.00 3,309.9 0.0 1717.01 2236.38 3,953.4014.65
63.74 5.968 0.00 0.20 2.61 0.80 5 70.0 1.00 0.00 13.01 49.76 0.00 3,309.9 0.0 1840.13 2400.55 4,240.6814.65
67.21 5.911 0.00 0.20 2.61 0.80 6 90.0 1.00 0.00 12.92 49.76 0.00 3,309.9 0.0 1927.71 2530.98 4,458.6914.65
70.11 5.911 0.00 0.20 2.59 0.80 7 110.0 1.00 0.00 13.28 49.76 0.00 3,545.7 0.0 2051.93 2640.19 4,692.1215.28
72.62 14.842 0.00 0.25 2.44 0.80 8 130.0 1.00 0.00 18.23 49.76 0.00 4,091.0 0.0 2741.75 2734.70 5,476.4511.67
74.84 5.938 0.00 0.19 2.62 0.80 9 150.0 1.00 0.00 12.90 49.76 0.00 3,244.7 0.0 2146.35 2818.34 4,964.6914.46
76.83 5.938 0.00 0.19 2.62 0.8010170.0 1.00 0.00 12.88 49.76 0.00 3,244.7 0.0 2200.13 2893.59 5,093.7214.46
78.66 14.898 0.00 0.24 2.46 0.8011190.0 1.00 0.00 17.85 49.76 0.00 4,049.9 0.0 2930.77 2962.14 5,892.9110.83
80.33 17.328 0.00 0.26 2.41 0.8012210.0 1.00 0.00 19.49 25.79 0.00 3,669.1 0.0 3204.02 1552.41 4,756.4310.00
81.88 5.964 0.00 0.18 2.66 0.8013230.0 1.00 0.00 12.11 15.47 0.00 2,312.4 0.0 2241.59 949.46 3,191.0513.01
83.33 15.009 0.00 0.23 2.50 0.8014250.0 1.00 0.00 17.17 0.00 0.00 2,587.9 0.0 3034.62 0.00 3,034.629.17
84.69 17.394 0.00 0.25 2.43 0.8015270.0 1.00 0.00 19.13 0.00 0.00 2,764.3 0.0 3340.49 0.00 3,340.499.17
85.98 4.813 0.00 0.15 2.77 0.8016290.0 1.00 0.00 9.99 0.00 0.00 1,558.2 0.0 2024.13 0.00 2,024.1310.72
87.19 5.990 0.00 0.18 2.66 0.8017310.0 1.00 0.00 12.13 0.00 0.00 2,114.8 0.0 2392.87 0.00 2,392.8712.83
88.35 6.033 0.00 0.18 2.66 0.8018330.0 1.00 0.00 12.16 0.00 0.00 2,114.8 0.0 2428.77 0.00 2,428.7712.83
89.45 4.833 0.00 0.14 2.80 0.8019350.0 1.00 0.00 9.53 0.00 0.00 1,353.7 0.0 2027.45 0.00 2,027.459.90
90.50 4.833 0.00 0.14 2.80 0.8020370.0 1.00 0.00 9.53 0.00 0.00 1,353.7 0.0 2051.31 0.00 2,051.319.90
91.51 6.076 0.00 0.16 2.73 0.8021390.0 1.00 0.00 10.92 0.00 0.00 1,446.0 0.0 2320.06 0.00 2,320.0610.55
92.48 4.833 0.00 0.14 2.80 0.8022410.0 1.00 0.00 9.53 0.00 0.00 1,353.7 0.0 2096.13 0.00 2,096.139.90
93.41 4.833 0.00 0.14 2.80 0.8023430.0 1.00 0.00 9.53 0.00 0.00 1,353.7 0.0 2117.25 0.00 2,117.259.90
94.09 4.063 0.00 0.19 2.65 0.8024445.0 1.00 0.00 6.44 0.00 0.00 799.5 0.0 1362.03 0.00 1,362.035.51
59,696.3 0.0 78,198.51
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 9IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.2D + 1.0W 158 mph Wind at 90° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.20
Ice Importance Factor:1.00
1.2D + 1.0W 90° WindLoad Case:
46.15 0.446 0.00 0.35 2.16 0.85 1 2.0 1.00 0.00 2.57 2.49 0.00 895.1 0.0 218.12 86.90 305.013.49
46.15 3.941 0.00 0.19 2.64 0.85 2 12.0 1.00 0.00 10.12 39.81 0.00 2,604.2 0.0 1049.84 1390.36 2,440.2011.72
53.33 5.911 0.00 0.20 2.61 0.85 3 30.0 1.00 0.00 13.40 49.76 0.00 3,309.9 0.0 1587.02 2008.36 3,595.3814.65
59.38 5.911 0.00 0.20 2.61 0.85 4 50.0 1.00 0.00 13.32 49.76 0.00 3,309.9 0.0 1755.99 2236.38 3,992.3814.65
63.74 5.968 0.00 0.20 2.61 0.85 5 70.0 1.00 0.00 13.31 49.76 0.00 3,309.9 0.0 1882.34 2400.55 4,282.8914.65
67.21 5.911 0.00 0.20 2.61 0.85 6 90.0 1.00 0.00 13.21 49.76 0.00 3,309.9 0.0 1971.83 2530.98 4,502.8114.65
70.11 5.911 0.00 0.20 2.59 0.85 7 110.0 1.00 0.00 13.58 49.76 0.00 3,545.7 0.0 2097.60 2640.19 4,737.7915.28
72.62 14.842 0.00 0.25 2.44 0.85 8 130.0 1.00 0.00 18.98 49.76 0.00 4,091.0 0.0 2853.34 2734.70 5,588.0411.67
74.84 5.938 0.00 0.19 2.62 0.85 9 150.0 1.00 0.00 13.20 49.76 0.00 3,244.7 0.0 2195.73 2818.34 5,014.0714.46
76.83 5.938 0.00 0.19 2.62 0.8510170.0 1.00 0.00 13.18 49.76 0.00 3,244.7 0.0 2250.83 2893.59 5,144.4214.46
78.66 14.898 0.00 0.24 2.46 0.8511190.0 1.00 0.00 18.60 49.76 0.00 4,049.9 0.0 3053.05 2962.14 6,015.1910.83
80.33 17.328 0.00 0.26 2.41 0.8512210.0 1.00 0.00 20.36 25.79 0.00 3,669.1 0.0 3346.42 1552.41 4,898.8310.00
81.88 5.964 0.00 0.18 2.66 0.8513230.0 1.00 0.00 12.41 15.47 0.00 2,312.4 0.0 2296.79 949.46 3,246.2413.01
83.33 15.009 0.00 0.23 2.50 0.8514250.0 1.00 0.00 17.92 0.00 0.00 2,587.9 0.0 3167.26 0.00 3,167.269.17
84.69 17.394 0.00 0.25 2.43 0.8515270.0 1.00 0.00 20.00 0.00 0.00 2,764.3 0.0 3492.36 0.00 3,492.369.17
85.98 4.813 0.00 0.15 2.77 0.8516290.0 1.00 0.00 10.23 0.00 0.00 1,558.2 0.0 2072.89 0.00 2,072.8910.72
87.19 5.990 0.00 0.18 2.66 0.8517310.0 1.00 0.00 12.43 0.00 0.00 2,114.8 0.0 2451.95 0.00 2,451.9512.83
88.35 6.033 0.00 0.18 2.66 0.8518330.0 1.00 0.00 12.46 0.00 0.00 2,114.8 0.0 2489.04 0.00 2,489.0412.83
89.45 4.833 0.00 0.14 2.80 0.8519350.0 1.00 0.00 9.77 0.00 0.00 1,353.7 0.0 2078.88 0.00 2,078.889.90
90.50 4.833 0.00 0.14 2.80 0.8520370.0 1.00 0.00 9.77 0.00 0.00 1,353.7 0.0 2103.35 0.00 2,103.359.90
91.51 6.076 0.00 0.16 2.73 0.8521390.0 1.00 0.00 11.22 0.00 0.00 1,446.0 0.0 2384.62 0.00 2,384.6210.55
92.48 4.833 0.00 0.14 2.80 0.8522410.0 1.00 0.00 9.77 0.00 0.00 1,353.7 0.0 2149.30 0.00 2,149.309.90
93.41 4.833 0.00 0.14 2.80 0.8523430.0 1.00 0.00 9.77 0.00 0.00 1,353.7 0.0 2170.96 0.00 2,170.969.90
94.09 4.063 0.00 0.19 2.65 0.8524445.0 1.00 0.00 6.64 0.00 0.00 799.5 0.0 1405.02 0.00 1,405.025.51
59,696.3 0.0 79,728.88
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 10IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
0.9D + 1.0W 158 mph Wind at Normal To Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:0.90
Ice Importance Factor:1.00
0.9D + 1.0W Normal WindLoad Case:
46.15 0.446 0.00 0.35 2.16 1.00 1 2.0 1.00 0.00 2.64 2.49 0.00 671.3 0.0 223.78 86.90 310.683.49
46.15 3.941 0.00 0.19 2.64 1.00 2 12.0 1.00 0.00 10.71 39.81 0.00 1,953.1 0.0 1111.16 1390.36 2,501.5211.72
53.33 5.911 0.00 0.20 2.61 1.00 3 30.0 1.00 0.00 14.29 49.76 0.00 2,482.4 0.0 1692.04 2008.36 3,700.4014.65
59.38 5.911 0.00 0.20 2.61 1.00 4 50.0 1.00 0.00 14.20 49.76 0.00 2,482.4 0.0 1872.93 2236.38 4,109.3214.65
63.74 5.968 0.00 0.20 2.61 1.00 5 70.0 1.00 0.00 14.20 49.76 0.00 2,482.4 0.0 2008.98 2400.55 4,409.5214.65
67.21 5.911 0.00 0.20 2.61 1.00 6 90.0 1.00 0.00 14.10 49.76 0.00 2,482.4 0.0 2104.17 2530.98 4,635.1514.65
70.11 5.911 0.00 0.20 2.59 1.00 7 110.0 1.00 0.00 14.46 49.76 0.00 2,659.2 0.0 2234.58 2640.19 4,874.7815.28
72.62 14.842 0.00 0.25 2.44 1.00 8 130.0 1.00 0.00 21.20 49.76 0.00 3,068.2 0.0 3188.09 2734.70 5,922.7911.67
74.84 5.938 0.00 0.19 2.62 1.00 9 150.0 1.00 0.00 14.09 49.76 0.00 2,433.5 0.0 2343.89 2818.34 5,162.2314.46
76.83 5.938 0.00 0.19 2.62 1.0010170.0 1.00 0.00 14.07 49.76 0.00 2,433.5 0.0 2402.95 2893.59 5,296.5314.46
78.66 14.898 0.00 0.24 2.46 1.0011190.0 1.00 0.00 20.83 49.76 0.00 3,037.4 0.0 3419.89 2962.14 6,382.0310.83
80.33 17.328 0.00 0.26 2.41 1.0012210.0 1.00 0.00 22.96 25.79 0.00 2,751.8 0.0 3773.62 1552.41 5,326.0310.00
81.88 5.964 0.00 0.18 2.66 1.0013230.0 1.00 0.00 13.30 15.47 0.00 1,734.3 0.0 2462.36 949.46 3,411.8113.01
83.33 15.009 0.00 0.23 2.50 1.0014250.0 1.00 0.00 20.17 0.00 0.00 1,940.9 0.0 3565.17 0.00 3,565.179.17
84.69 17.394 0.00 0.25 2.43 1.0015270.0 1.00 0.00 22.61 0.00 0.00 2,073.2 0.0 3947.98 0.00 3,947.989.17
85.98 4.813 0.00 0.15 2.77 1.0016290.0 1.00 0.00 10.95 0.00 0.00 1,168.6 0.0 2219.15 0.00 2,219.1510.72
87.19 5.990 0.00 0.18 2.66 1.0017310.0 1.00 0.00 13.33 0.00 0.00 1,586.1 0.0 2629.21 0.00 2,629.2112.83
88.35 6.033 0.00 0.18 2.66 1.0018330.0 1.00 0.00 13.36 0.00 0.00 1,586.1 0.0 2669.84 0.00 2,669.8412.83
89.45 4.833 0.00 0.14 2.80 1.0019350.0 1.00 0.00 10.49 0.00 0.00 1,015.3 0.0 2233.18 0.00 2,233.189.90
90.50 4.833 0.00 0.14 2.80 1.0020370.0 1.00 0.00 10.49 0.00 0.00 1,015.3 0.0 2259.46 0.00 2,259.469.90
91.51 6.076 0.00 0.16 2.73 1.0021390.0 1.00 0.00 12.13 0.00 0.00 1,084.5 0.0 2578.31 0.00 2,578.3110.55
92.48 4.833 0.00 0.14 2.80 1.0022410.0 1.00 0.00 10.49 0.00 0.00 1,015.3 0.0 2308.82 0.00 2,308.829.90
93.41 4.833 0.00 0.14 2.80 1.0023430.0 1.00 0.00 10.49 0.00 0.00 1,015.3 0.0 2332.09 0.00 2,332.099.90
94.09 4.063 0.00 0.19 2.65 1.0024445.0 1.00 0.00 7.25 0.00 0.00 599.6 0.0 1533.98 0.00 1,533.985.51
44,772.2 0.0 84,319.97
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 11IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
0.9D + 1.0W 158 mph Wind at 60° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:0.90
Ice Importance Factor:1.00
0.9D + 1.0W 60° WindLoad Case:
46.15 0.446 0.00 0.35 2.16 0.80 1 2.0 1.00 0.00 2.55 2.49 0.00 671.3 0.0 216.23 86.90 303.123.49
46.15 3.941 0.00 0.19 2.64 0.80 2 12.0 1.00 0.00 9.92 39.81 0.00 1,953.1 0.0 1029.40 1390.36 2,419.7611.72
53.33 5.911 0.00 0.20 2.61 0.80 3 30.0 1.00 0.00 13.10 49.76 0.00 2,482.4 0.0 1552.01 2008.36 3,560.3714.65
59.38 5.911 0.00 0.20 2.61 0.80 4 50.0 1.00 0.00 13.02 49.76 0.00 2,482.4 0.0 1717.01 2236.38 3,953.4014.65
63.74 5.968 0.00 0.20 2.61 0.80 5 70.0 1.00 0.00 13.01 49.76 0.00 2,482.4 0.0 1840.13 2400.55 4,240.6814.65
67.21 5.911 0.00 0.20 2.61 0.80 6 90.0 1.00 0.00 12.92 49.76 0.00 2,482.4 0.0 1927.71 2530.98 4,458.6914.65
70.11 5.911 0.00 0.20 2.59 0.80 7 110.0 1.00 0.00 13.28 49.76 0.00 2,659.2 0.0 2051.93 2640.19 4,692.1215.28
72.62 14.842 0.00 0.25 2.44 0.80 8 130.0 1.00 0.00 18.23 49.76 0.00 3,068.2 0.0 2741.75 2734.70 5,476.4511.67
74.84 5.938 0.00 0.19 2.62 0.80 9 150.0 1.00 0.00 12.90 49.76 0.00 2,433.5 0.0 2146.35 2818.34 4,964.6914.46
76.83 5.938 0.00 0.19 2.62 0.8010170.0 1.00 0.00 12.88 49.76 0.00 2,433.5 0.0 2200.13 2893.59 5,093.7214.46
78.66 14.898 0.00 0.24 2.46 0.8011190.0 1.00 0.00 17.85 49.76 0.00 3,037.4 0.0 2930.77 2962.14 5,892.9110.83
80.33 17.328 0.00 0.26 2.41 0.8012210.0 1.00 0.00 19.49 25.79 0.00 2,751.8 0.0 3204.02 1552.41 4,756.4310.00
81.88 5.964 0.00 0.18 2.66 0.8013230.0 1.00 0.00 12.11 15.47 0.00 1,734.3 0.0 2241.59 949.46 3,191.0513.01
83.33 15.009 0.00 0.23 2.50 0.8014250.0 1.00 0.00 17.17 0.00 0.00 1,940.9 0.0 3034.62 0.00 3,034.629.17
84.69 17.394 0.00 0.25 2.43 0.8015270.0 1.00 0.00 19.13 0.00 0.00 2,073.2 0.0 3340.49 0.00 3,340.499.17
85.98 4.813 0.00 0.15 2.77 0.8016290.0 1.00 0.00 9.99 0.00 0.00 1,168.6 0.0 2024.13 0.00 2,024.1310.72
87.19 5.990 0.00 0.18 2.66 0.8017310.0 1.00 0.00 12.13 0.00 0.00 1,586.1 0.0 2392.87 0.00 2,392.8712.83
88.35 6.033 0.00 0.18 2.66 0.8018330.0 1.00 0.00 12.16 0.00 0.00 1,586.1 0.0 2428.77 0.00 2,428.7712.83
89.45 4.833 0.00 0.14 2.80 0.8019350.0 1.00 0.00 9.53 0.00 0.00 1,015.3 0.0 2027.45 0.00 2,027.459.90
90.50 4.833 0.00 0.14 2.80 0.8020370.0 1.00 0.00 9.53 0.00 0.00 1,015.3 0.0 2051.31 0.00 2,051.319.90
91.51 6.076 0.00 0.16 2.73 0.8021390.0 1.00 0.00 10.92 0.00 0.00 1,084.5 0.0 2320.06 0.00 2,320.0610.55
92.48 4.833 0.00 0.14 2.80 0.8022410.0 1.00 0.00 9.53 0.00 0.00 1,015.3 0.0 2096.13 0.00 2,096.139.90
93.41 4.833 0.00 0.14 2.80 0.8023430.0 1.00 0.00 9.53 0.00 0.00 1,015.3 0.0 2117.25 0.00 2,117.259.90
94.09 4.063 0.00 0.19 2.65 0.8024445.0 1.00 0.00 6.44 0.00 0.00 599.6 0.0 1362.03 0.00 1,362.035.51
44,772.2 0.0 78,198.51
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 12IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
0.9D + 1.0W 158 mph Wind at 90° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:0.90
Ice Importance Factor:1.00
0.9D + 1.0W 90° WindLoad Case:
46.15 0.446 0.00 0.35 2.16 0.85 1 2.0 1.00 0.00 2.57 2.49 0.00 671.3 0.0 218.12 86.90 305.013.49
46.15 3.941 0.00 0.19 2.64 0.85 2 12.0 1.00 0.00 10.12 39.81 0.00 1,953.1 0.0 1049.84 1390.36 2,440.2011.72
53.33 5.911 0.00 0.20 2.61 0.85 3 30.0 1.00 0.00 13.40 49.76 0.00 2,482.4 0.0 1587.02 2008.36 3,595.3814.65
59.38 5.911 0.00 0.20 2.61 0.85 4 50.0 1.00 0.00 13.32 49.76 0.00 2,482.4 0.0 1755.99 2236.38 3,992.3814.65
63.74 5.968 0.00 0.20 2.61 0.85 5 70.0 1.00 0.00 13.31 49.76 0.00 2,482.4 0.0 1882.34 2400.55 4,282.8914.65
67.21 5.911 0.00 0.20 2.61 0.85 6 90.0 1.00 0.00 13.21 49.76 0.00 2,482.4 0.0 1971.83 2530.98 4,502.8114.65
70.11 5.911 0.00 0.20 2.59 0.85 7 110.0 1.00 0.00 13.58 49.76 0.00 2,659.2 0.0 2097.60 2640.19 4,737.7915.28
72.62 14.842 0.00 0.25 2.44 0.85 8 130.0 1.00 0.00 18.98 49.76 0.00 3,068.2 0.0 2853.34 2734.70 5,588.0411.67
74.84 5.938 0.00 0.19 2.62 0.85 9 150.0 1.00 0.00 13.20 49.76 0.00 2,433.5 0.0 2195.73 2818.34 5,014.0714.46
76.83 5.938 0.00 0.19 2.62 0.8510170.0 1.00 0.00 13.18 49.76 0.00 2,433.5 0.0 2250.83 2893.59 5,144.4214.46
78.66 14.898 0.00 0.24 2.46 0.8511190.0 1.00 0.00 18.60 49.76 0.00 3,037.4 0.0 3053.05 2962.14 6,015.1910.83
80.33 17.328 0.00 0.26 2.41 0.8512210.0 1.00 0.00 20.36 25.79 0.00 2,751.8 0.0 3346.42 1552.41 4,898.8310.00
81.88 5.964 0.00 0.18 2.66 0.8513230.0 1.00 0.00 12.41 15.47 0.00 1,734.3 0.0 2296.79 949.46 3,246.2413.01
83.33 15.009 0.00 0.23 2.50 0.8514250.0 1.00 0.00 17.92 0.00 0.00 1,940.9 0.0 3167.26 0.00 3,167.269.17
84.69 17.394 0.00 0.25 2.43 0.8515270.0 1.00 0.00 20.00 0.00 0.00 2,073.2 0.0 3492.36 0.00 3,492.369.17
85.98 4.813 0.00 0.15 2.77 0.8516290.0 1.00 0.00 10.23 0.00 0.00 1,168.6 0.0 2072.89 0.00 2,072.8910.72
87.19 5.990 0.00 0.18 2.66 0.8517310.0 1.00 0.00 12.43 0.00 0.00 1,586.1 0.0 2451.95 0.00 2,451.9512.83
88.35 6.033 0.00 0.18 2.66 0.8518330.0 1.00 0.00 12.46 0.00 0.00 1,586.1 0.0 2489.04 0.00 2,489.0412.83
89.45 4.833 0.00 0.14 2.80 0.8519350.0 1.00 0.00 9.77 0.00 0.00 1,015.3 0.0 2078.88 0.00 2,078.889.90
90.50 4.833 0.00 0.14 2.80 0.8520370.0 1.00 0.00 9.77 0.00 0.00 1,015.3 0.0 2103.35 0.00 2,103.359.90
91.51 6.076 0.00 0.16 2.73 0.8521390.0 1.00 0.00 11.22 0.00 0.00 1,084.5 0.0 2384.62 0.00 2,384.6210.55
92.48 4.833 0.00 0.14 2.80 0.8522410.0 1.00 0.00 9.77 0.00 0.00 1,015.3 0.0 2149.30 0.00 2,149.309.90
93.41 4.833 0.00 0.14 2.80 0.8523430.0 1.00 0.00 9.77 0.00 0.00 1,015.3 0.0 2170.96 0.00 2,170.969.90
94.09 4.063 0.00 0.19 2.65 0.8524445.0 1.00 0.00 6.64 0.00 0.00 599.6 0.0 1405.02 0.00 1,405.025.51
44,772.2 0.0 79,728.88
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 13IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.0D + 1.0W 60 mph Wind at Normal To Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.00
Ice Importance Factor:1.00
1.0D + 1.0W Normal WindLoad Case:
6.65 0.446 0.00 0.35 2.16 1.00 1 2.0 1.00 0.00 2.64 2.49 0.00 745.9 0.0 32.30 12.53 44.833.49
6.65 3.941 0.00 0.19 2.64 1.00 2 12.0 1.00 0.00 10.73 39.81 0.00 2,170.2 0.0 160.43 200.50 360.9411.72
7.69 5.911 0.00 0.20 2.61 1.00 3 30.0 1.00 0.00 14.41 49.76 0.00 2,758.2 0.0 246.11 289.62 535.7314.65
8.56 5.911 0.00 0.20 2.61 1.00 4 50.0 1.00 0.00 14.41 49.76 0.00 2,758.2 0.0 274.06 322.50 596.5614.65
9.19 5.968 0.00 0.20 2.61 1.00 5 70.0 1.00 0.00 14.47 49.76 0.00 2,758.2 0.0 295.15 346.18 641.3214.65
9.69 5.911 0.00 0.20 2.61 1.00 6 90.0 1.00 0.00 14.41 49.76 0.00 2,758.2 0.0 310.16 364.99 675.1414.65
10.11 5.911 0.00 0.20 2.59 1.00 7 110.0 1.00 0.00 14.81 49.76 0.00 2,954.7 0.0 329.88 380.74 710.6115.28
10.47 14.842 0.00 0.25 2.44 1.00 8 130.0 1.00 0.00 21.67 49.76 0.00 3,409.1 0.0 469.85 394.36 864.2111.67
10.79 5.938 0.00 0.19 2.62 1.00 9 150.0 1.00 0.00 14.34 49.76 0.00 2,703.9 0.0 343.94 406.43 750.3714.46
11.08 5.938 0.00 0.19 2.62 1.0010170.0 1.00 0.00 14.34 49.76 0.00 2,703.9 0.0 353.12 417.28 770.4014.46
11.34 14.898 0.00 0.24 2.46 1.0011190.0 1.00 0.00 21.22 49.76 0.00 3,374.9 0.0 502.33 427.16 929.4910.83
11.58 17.328 0.00 0.26 2.41 1.0012210.0 1.00 0.00 23.20 25.79 0.00 3,057.5 0.0 549.97 223.87 773.8410.00
11.81 5.964 0.00 0.18 2.66 1.0013230.0 1.00 0.00 13.48 15.47 0.00 1,927.0 0.0 359.75 136.92 496.6713.01
12.02 15.009 0.00 0.23 2.50 1.0014250.0 1.00 0.00 20.33 0.00 0.00 2,156.6 0.0 518.20 0.00 518.209.17
12.21 17.394 0.00 0.25 2.43 1.0015270.0 1.00 0.00 22.77 0.00 0.00 2,303.6 0.0 573.29 0.00 573.299.17
12.40 4.813 0.00 0.15 2.77 1.0016290.0 1.00 0.00 10.95 0.00 0.00 1,298.5 0.0 320.02 0.00 320.0210.72
12.57 5.990 0.00 0.18 2.66 1.0017310.0 1.00 0.00 13.41 0.00 0.00 1,762.3 0.0 381.39 0.00 381.3912.83
12.74 6.033 0.00 0.18 2.66 1.0018330.0 1.00 0.00 13.45 0.00 0.00 1,762.3 0.0 387.51 0.00 387.5112.83
12.90 4.833 0.00 0.14 2.80 1.0019350.0 1.00 0.00 10.49 0.00 0.00 1,128.1 0.0 322.04 0.00 322.049.90
13.05 4.833 0.00 0.14 2.80 1.0020370.0 1.00 0.00 10.49 0.00 0.00 1,128.1 0.0 325.83 0.00 325.839.90
13.20 6.076 0.00 0.16 2.73 1.0021390.0 1.00 0.00 12.13 0.00 0.00 1,205.0 0.0 371.81 0.00 371.8110.55
13.34 4.833 0.00 0.14 2.80 1.0022410.0 1.00 0.00 10.49 0.00 0.00 1,128.1 0.0 332.95 0.00 332.959.90
13.47 4.833 0.00 0.14 2.80 1.0023430.0 1.00 0.00 10.49 0.00 0.00 1,128.1 0.0 336.30 0.00 336.309.90
13.57 4.063 0.00 0.19 2.65 1.0024445.0 1.00 0.00 7.25 0.00 0.00 666.2 0.0 221.21 0.00 221.215.51
49,746.9 0.0 12,240.68
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 14IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.0D + 1.0W 60 mph Wind at 60° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.00
Ice Importance Factor:1.00
1.0D + 1.0W 60° WindLoad Case:
6.65 0.446 0.00 0.35 2.16 0.80 1 2.0 1.00 0.00 2.55 2.49 0.00 745.9 0.0 31.21 12.53 43.743.49
6.65 3.941 0.00 0.19 2.64 0.80 2 12.0 1.00 0.00 9.94 39.81 0.00 2,170.2 0.0 148.64 200.50 349.1511.72
7.69 5.911 0.00 0.20 2.61 0.80 3 30.0 1.00 0.00 13.23 49.76 0.00 2,758.2 0.0 225.92 289.62 515.5414.65
8.56 5.911 0.00 0.20 2.61 0.80 4 50.0 1.00 0.00 13.23 49.76 0.00 2,758.2 0.0 251.57 322.50 574.0714.65
9.19 5.968 0.00 0.20 2.61 0.80 5 70.0 1.00 0.00 13.27 49.76 0.00 2,758.2 0.0 270.80 346.18 616.9814.65
9.69 5.911 0.00 0.20 2.61 0.80 6 90.0 1.00 0.00 13.23 49.76 0.00 2,758.2 0.0 284.71 364.99 649.6914.65
10.11 5.911 0.00 0.20 2.59 0.80 7 110.0 1.00 0.00 13.62 49.76 0.00 2,954.7 0.0 303.54 380.74 684.2715.28
10.47 14.842 0.00 0.25 2.44 0.80 8 130.0 1.00 0.00 18.70 49.76 0.00 3,409.1 0.0 405.48 394.36 799.8511.67
10.79 5.938 0.00 0.19 2.62 0.80 9 150.0 1.00 0.00 13.15 49.76 0.00 2,703.9 0.0 315.45 406.43 721.8814.46
11.08 5.938 0.00 0.19 2.62 0.8010170.0 1.00 0.00 13.15 49.76 0.00 2,703.9 0.0 323.87 417.28 741.1514.46
11.34 14.898 0.00 0.24 2.46 0.8011190.0 1.00 0.00 18.24 49.76 0.00 3,374.9 0.0 431.80 427.16 858.9610.83
11.58 17.328 0.00 0.26 2.41 0.8012210.0 1.00 0.00 19.74 25.79 0.00 3,057.5 0.0 467.83 223.87 691.7010.00
11.81 5.964 0.00 0.18 2.66 0.8013230.0 1.00 0.00 12.29 15.47 0.00 1,927.0 0.0 327.91 136.92 464.8313.01
12.02 15.009 0.00 0.23 2.50 0.8014250.0 1.00 0.00 17.33 0.00 0.00 2,156.6 0.0 441.69 0.00 441.699.17
12.21 17.394 0.00 0.25 2.43 0.8015270.0 1.00 0.00 19.29 0.00 0.00 2,303.6 0.0 485.68 0.00 485.689.17
12.40 4.813 0.00 0.15 2.77 0.8016290.0 1.00 0.00 9.99 0.00 0.00 1,298.5 0.0 291.90 0.00 291.9010.72
12.57 5.990 0.00 0.18 2.66 0.8017310.0 1.00 0.00 12.21 0.00 0.00 1,762.3 0.0 347.31 0.00 347.3112.83
12.74 6.033 0.00 0.18 2.66 0.8018330.0 1.00 0.00 12.24 0.00 0.00 1,762.3 0.0 352.75 0.00 352.7512.83
12.90 4.833 0.00 0.14 2.80 0.8019350.0 1.00 0.00 9.53 0.00 0.00 1,128.1 0.0 292.37 0.00 292.379.90
13.05 4.833 0.00 0.14 2.80 0.8020370.0 1.00 0.00 9.53 0.00 0.00 1,128.1 0.0 295.81 0.00 295.819.90
13.20 6.076 0.00 0.16 2.73 0.8021390.0 1.00 0.00 10.92 0.00 0.00 1,205.0 0.0 334.57 0.00 334.5710.55
13.34 4.833 0.00 0.14 2.80 0.8022410.0 1.00 0.00 9.53 0.00 0.00 1,128.1 0.0 302.28 0.00 302.289.90
13.47 4.833 0.00 0.14 2.80 0.8023430.0 1.00 0.00 9.53 0.00 0.00 1,128.1 0.0 305.32 0.00 305.329.90
13.57 4.063 0.00 0.19 2.65 0.8024445.0 1.00 0.00 6.44 0.00 0.00 666.2 0.0 196.42 0.00 196.425.51
49,746.9 0.0 11,357.92
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Section Forces
Page: 15IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Sect
Seq
qz
(psf)
Total
Flat
Area
(sqft)
Ice
Round
Area
(sqft)
Sol
Ratio Cf Df
Wind
Height
(ft)Dr
Ice
Thick
(in)
Eff
Area
(sqft)
Linear
Area
(sqft)
Ice
Linear
Area
(sqft)
Total
Weight
(lb)
Weight
Ice (lb)
Struct
Force
(lb)
Linear
Force
(lb)
Total
Force
(lb)
Ice Dead Load Factor:0.00
1.0D + 1.0W 60 mph Wind at 90° From Face
Wind Load Factor:1.00
Total
Round
Area
(sqft)
Wind Importance Factor:1.00
Dead Load Factor:1.00
Ice Importance Factor:1.00
1.0D + 1.0W 90° WindLoad Case:
6.65 0.446 0.00 0.35 2.16 0.85 1 2.0 1.00 0.00 2.58 2.49 0.00 745.9 0.0 31.48 12.53 44.013.49
6.65 3.941 0.00 0.19 2.64 0.85 2 12.0 1.00 0.00 10.13 39.81 0.00 2,170.2 0.0 151.59 200.50 352.0911.72
7.69 5.911 0.00 0.20 2.61 0.85 3 30.0 1.00 0.00 13.52 49.76 0.00 2,758.2 0.0 230.97 289.62 520.5914.65
8.56 5.911 0.00 0.20 2.61 0.85 4 50.0 1.00 0.00 13.52 49.76 0.00 2,758.2 0.0 257.19 322.50 579.7014.65
9.19 5.968 0.00 0.20 2.61 0.85 5 70.0 1.00 0.00 13.57 49.76 0.00 2,758.2 0.0 276.89 346.18 623.0614.65
9.69 5.911 0.00 0.20 2.61 0.85 6 90.0 1.00 0.00 13.52 49.76 0.00 2,758.2 0.0 291.07 364.99 656.0614.65
10.11 5.911 0.00 0.20 2.59 0.85 7 110.0 1.00 0.00 13.92 49.76 0.00 2,954.7 0.0 310.12 380.74 690.8615.28
10.47 14.842 0.00 0.25 2.44 0.85 8 130.0 1.00 0.00 19.44 49.76 0.00 3,409.1 0.0 421.57 394.36 815.9411.67
10.79 5.938 0.00 0.19 2.62 0.85 9 150.0 1.00 0.00 13.45 49.76 0.00 2,703.9 0.0 322.57 406.43 729.0014.46
11.08 5.938 0.00 0.19 2.62 0.8510170.0 1.00 0.00 13.45 49.76 0.00 2,703.9 0.0 331.19 417.28 748.4614.46
11.34 14.898 0.00 0.24 2.46 0.8511190.0 1.00 0.00 18.99 49.76 0.00 3,374.9 0.0 449.43 427.16 876.5910.83
11.58 17.328 0.00 0.26 2.41 0.8512210.0 1.00 0.00 20.60 25.79 0.00 3,057.5 0.0 488.36 223.87 712.2310.00
11.81 5.964 0.00 0.18 2.66 0.8513230.0 1.00 0.00 12.58 15.47 0.00 1,927.0 0.0 335.87 136.92 472.7913.01
12.02 15.009 0.00 0.23 2.50 0.8514250.0 1.00 0.00 18.08 0.00 0.00 2,156.6 0.0 460.82 0.00 460.829.17
12.21 17.394 0.00 0.25 2.43 0.8515270.0 1.00 0.00 20.16 0.00 0.00 2,303.6 0.0 507.58 0.00 507.589.17
12.40 4.813 0.00 0.15 2.77 0.8516290.0 1.00 0.00 10.23 0.00 0.00 1,298.5 0.0 298.93 0.00 298.9310.72
12.57 5.990 0.00 0.18 2.66 0.8517310.0 1.00 0.00 12.51 0.00 0.00 1,762.3 0.0 355.83 0.00 355.8312.83
12.74 6.033 0.00 0.18 2.66 0.8518330.0 1.00 0.00 12.54 0.00 0.00 1,762.3 0.0 361.44 0.00 361.4412.83
12.90 4.833 0.00 0.14 2.80 0.8519350.0 1.00 0.00 9.77 0.00 0.00 1,128.1 0.0 299.79 0.00 299.799.90
13.05 4.833 0.00 0.14 2.80 0.8520370.0 1.00 0.00 9.77 0.00 0.00 1,128.1 0.0 303.32 0.00 303.329.90
13.20 6.076 0.00 0.16 2.73 0.8521390.0 1.00 0.00 11.22 0.00 0.00 1,205.0 0.0 343.88 0.00 343.8810.55
13.34 4.833 0.00 0.14 2.80 0.8522410.0 1.00 0.00 9.77 0.00 0.00 1,128.1 0.0 309.95 0.00 309.959.90
13.47 4.833 0.00 0.14 2.80 0.8523430.0 1.00 0.00 9.77 0.00 0.00 1,128.1 0.0 313.07 0.00 313.079.90
13.57 4.063 0.00 0.19 2.65 0.8524445.0 1.00 0.00 6.64 0.00 0.00 666.2 0.0 202.61 0.00 202.615.51
49,746.9 0.0 11,578.61
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Force/Stress Compression Summary
Page: 16IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Member
Force
(kips)Load Case
Len
(ft)
Bracing %
KL/R
Fy
(ksi)
Mem
Cap
(kips)
Leg
Use %ControlsX Y ZSect
Top
Elev
LEG MEMBERS
SOL - 3 1/4" SOLID -171.00 1.2D + 1.0W 60° Wind 1.85 100 100 100 27.32 353.49 48.4 Member X50.0014
SOL - 3 1/4" SOLID -155.11 1.2D + 1.0W 60° Wind 3.97 100 100 100 58.62 290.39 53.4 Member X50.00220
SOL - 3 1/4" SOLID -156.77 1.2D + 1.0W 60° Wind 3.95 100 100 100 58.34 291.08 53.9 Member X50.00340
SOL - 3 1/4" SOLID -158.00 1.2D + 1.0W 60° Wind 3.95 100 100 100 58.34 291.08 54.3 Member X50.00460
SOL - 3 1/4" SOLID -140.79 1.2D + 1.0W 60° Wind 3.95 100 100 100 58.34 291.08 48.4 Member X50.00580
SOL - 3 1/4" SOLID -136.69 1.2D + 1.0W 60° Wind 3.95 100 100 100 58.34 291.08 47.0 Member X50.006100
SOL - 3 1/4" SOLID -148.80 1.2D + 1.0W Normal Wind 3.95 100 100 100 58.34 291.08 51.1 Member X50.007120
SOL - 3 1/2" S0LID -166.25 1.2D + 1.0W Normal Wind 3.95 100 100 100 54.17 349.34 47.6 Member X50.008140
SOL - 3" SOLID -136.07 1.2D + 1.0W Normal Wind 3.95 100 100 100 63.20 237.54 57.3 Member X50.009160
SOL - 3" SOLID -108.16 1.2D + 1.0W 90° Wind 3.95 100 100 100 63.20 237.54 45.5 Member X50.0010180
SOL - 3 1/4" SOLID -110.38 1.2D + 1.0W Normal Wind 3.95 100 100 100 58.34 291.08 37.9 Member X50.0011200
SOL - 3" SOLID -96.38 1.2D + 1.0W 60° Wind 3.95 100 100 100 63.20 237.54 40.6 Member X50.0012220
SOL - 2 3/4" SOLID -111.96 1.2D + 1.0W 60° Wind 3.95 100 100 100 68.95 188.81 59.3 Member X50.0013240
SOL - 2 3/4" SOLID -98.10 1.2D + 1.0W 60° Wind 3.95 100 100 100 68.95 188.81 52.0 Member X50.0014260
SOL - 2 3/4" SOLID -60.85 1.2D + 1.0W 60° Wind 3.95 100 100 100 68.95 188.81 32.2 Member X50.0015280
SOL - 2 1/4" SOLID -55.44 1.2D + 1.0W 90° Wind 3.95 100 100 100 84.27 106.46 52.1 Member X50.0016300
SOL - 2 1/2" SOLID -52.51 1.2D + 1.0W 90° Wind 3.95 100 100 100 75.84 145.06 36.2 Member X50.0017320
SOL - 2 1/2" SOLID -55.69 1.2D + 1.0W 90° Wind 3.95 100 100 100 75.84 145.06 38.4 Member X50.0018340
SOL - 2" SOLID -41.86 1.2D + 1.0W 60° Wind 3.95 100 100 100 94.80 73.28 57.1 Member X50.0019360
SOL - 2" SOLID -42.67 1.2D + 1.0W 60° Wind 3.95 100 100 100 94.80 73.28 58.2 Member X50.0020380
SOL - 2" SOLID -41.71 1.2D + 1.0W 60° Wind 3.95 100 100 100 94.80 73.28 56.9 Member X50.0021400
SOL - 2" SOLID -34.01 1.2D + 1.0W 60° Wind 3.95 100 100 100 94.80 73.28 46.4 Member X50.0022420
SOL - 2" SOLID -33.67 1.2D + 1.0W 60° Wind 3.95 100 100 100 94.80 73.28 45.9 Member X50.0023440
SOL - 2" SOLID -27.89 1.2D + 1.0W 60° Wind 3.25 100 100 100 78.00 90.61 30.8 Member X50.0024450
Force
(kips)Load Case
Len
(ft)
Bracing %
KL/R
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%ControlsX Y Z
HORIZONTAL MEMBERS
MemberSect
Top
Elev
1 4 0.00 0 0
2 20 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 5.00 100 100 100 120.75 17.59 0 0 18.0 Member Z-3.17 36.00
3 40 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 5.00 100 100 100 120.75 17.59 0 0 5.0 Member Z-0.89 36.00
4 60 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 5.00 100 100 100 120.75 17.59 0 0 18.9 Member Z-3.32 36.00
5 80 SAE - 2.5X2.5X0.1875 0.9D + 1.0W 90° Wind 5.00 100 100 100 120.75 17.59 0 0 13.9 Member Z-2.44 36.00
6 100 0.00 0 0
7 120 SAE - 2.5X2.5X0.25 1.2D + 1.0W 90° Wind 5.00 100 100 100 121.35 23.00 0 0 20.3 Member Z-4.67 36.00
8 140 SAE - 3X3X0.25 1.2D + 1.0W Normal Wind 5.00 100 100 100 110.68 31.87 0 0 19.8 Member Z-6.31 36.00
9 160 SAE - 2.5X2.5X0.25 0.9D + 1.0W Normal Wind 5.00 100 100 100 121.35 23.00 0 0 9.8 Member Z-2.25 36.00
10 180 0.00 0 0
11 200 SAE - 3X3X0.3125 1.2D + 1.0W 90° Wind 5.00 100 100 100 110.93 39.28 0 0 25.9 Member Z-10.1
8
36.00
12 220 0.00 0 0
13 240 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 5.00 100 100 100 120.75 17.59 0 0 26.1 Member Z-4.60 36.00
14 260 SAE - 3X3X0.25 1.2D + 1.0W 90° Wind 5.00 100 100 100 110.68 31.87 0 0 19.3 Member Z-6.16 36.00
15 280 SAE - 3X3X0.25 1.2D + 1.0W Normal Wind 5.00 100 100 100 110.68 31.87 0 0 4.4 Member Z-1.40 36.00
16 300 SAE - 2X2X0.25 1.2D + 1.0W 60° Wind 5.00 100 100 100 140.57 13.62 0 0 6.1 Member Z-0.84 36.00
17 320 0.00 0 0
18 340 0.00 0 0
19 360 SAE - 2X2X0.25 0.9D + 1.0W 90° Wind 5.00 100 100 100 140.57 13.62 0 0 14.5 Member Z-1.97 36.00
20 380 SAE - 2X2X0.25 0.9D + 1.0W 60° Wind 5.00 100 100 100 140.57 13.62 0 0 3.0 Member Z-0.41 36.00
21 400 0.00 0 0
22 420 0.00 0 0
23 440 0.00 0 0
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Force/Stress Compression Summary
Page: 17IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Force
(kips)Load Case
Len
(ft)
Bracing %
KL/R
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%ControlsX Y Z
HORIZONTAL MEMBERS
MemberSect
Top
Elev
24 450 SAE - 2.5X2.5X0.1875 0.9D + 1.0W Normal Wind 5.00 100 100 100 120.75 17.59 0 0 5.0 Member Z-0.89 36.00
Force
(kips)Load Case
Len
(ft)
Bracing %
KL/R
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%ControlsX Y Z
DIAGONAL MEMBERS
MemberSect
Top
Elev
1 4 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 2.71 50 50 50 77.96 12.75 0 0 T-Only-3.71 50.00
2 20 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.38 50 50 50 183.85 2.95 0 0 T-Only-2.05 50.00
3 40 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-2.84 50.00
4 60 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-2.08 50.00
5 80 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-1.00 50.00
6 100 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-1.73 50.00
7 120 SOL - 7/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 157.26 5.49 0 0 T-Only-0.52 50.00
8 140 PLT - 2"X1/2"1.2D + 1.0W Normal Wind 6.37 50 50 50 238.95 3.96 0 0 T-Only-3.39 50.00
9 160 SOL - 7/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 157.26 5.49 0 0 T-Only-2.26 50.00
10 180 SOL - 7/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 157.26 5.49 0 0 T-Only-3.36 50.00
11 200 PLT - 2"X5/8"1.2D + 1.0W Normal Wind 6.37 50 50 50 191.16 7.73 0 0 T-Only-2.61 50.00
12 220 PLT - 2"X5/8"1.2D + 1.0W Normal Wind 6.37 50 50 50 191.16 7.73 0 0 T-Only-7.49 50.00
13 240 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-2.15 50.00
14 260 PLT - 2"X1/2"1.2D + 1.0W Normal Wind 6.37 50 50 50 238.95 3.96 0 0 T-Only-0.06 50.00
15 280 PLT - 2"X1/2"1.2D + 1.0W Normal Wind 6.37 50 50 50 238.95 3.96 0 0 T-Only-1.93 50.00
16 300 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 220.57 1.42 0 0 T-Only-0.32 50.00
17 320 SOL - 7/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 157.26 5.49 0 0 T-Only-0.86 50.00
18 340 SOL - 7/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 157.26 5.49 0 0 T-Only-0.15 50.00
19 360 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 220.57 1.42 0 0 T-Only-0.96 50.00
20 380 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 220.57 1.42 0 0 T-Only-1.24 50.00
21 400 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 183.51 2.96 0 0 T-Only-0.12 50.00
22 420 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 220.57 1.42 0 0 T-Only-1.04 50.00
23 440 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 6.37 50 50 50 220.57 1.42 0 0 T-Only-0.10 50.00
24 450 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 5.96 50 50 50 171.75 3.38 0 0 T-Only-0.94 50.00
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Force/Stress Tension Summary
Page: 18IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Member
Force
(kips)Load Case
Fy
(ksi)
Mem
Cap
(kips)
Leg
Use %Controls
Top
ElevSect
LEG MEMBERS
1 4 0 0.00
2 20 0 0.00
3 40 0 0.00
4 60 0 0.00
5 80 0 0.00
6 100 0 0.00
7 120 0 0.00
8 140 0 0.00
9 160 0 0.00
10 180 0 0.00
11 200 0 0.00
12 220 0 0.00
13 240 0 0.00
14 260 0 0.00
15 280 0 0.00
16 300 0 0.00
17 320 0 0.00
18 340 0 0.00
19 360 0 0.00
20 380 0 0.00
21 400 0 0.00
22 420 0 0.00
23 440 0 0.00
24 450 SOL - 2" SOLID 0.32 0.9D + 1.0W 60° Wind 50 0.2 Member141.37
Member
Force
(kips)Load Case
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%Controls
Top
ElevSect
HORIZONTAL MEMBERS
B.S.
Cap
(kips)
1 4 PLT - 4" x 5/8"1.2D + 1.0W 60° Wind 36 0 0 65.1 Member81.0052.72
2 20 SAE - 2.5X2.5X0.1875 1.2D + 1.0W Normal Wind 36 0 0 11.4 Member29.223.32
3 40 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 36 0 0 11.3 Member29.223.29
4 60 SAE - 2.5X2.5X0.1875 1.2D + 1.0W Normal Wind 36 0 0 11.1 Member29.223.26
5 80 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 90° Wind 36 0 0 10.1 Member29.222.94
6 100 SAE - 2.5X2.5X0.1875 1.2D + 1.0W 60° Wind 36 0 0 10.4 Member29.223.05
7 120 SAE - 2.5X2.5X0.25 1.2D + 1.0W 60° Wind 36 0 0 10.4 Member38.564.02
8 140 SAE - 3X3X0.25 1.2D + 1.0W 60° Wind 36 0 0 10.7 Member46.665.01
9 160 SAE - 2.5X2.5X0.25 1.2D + 1.0W 90° Wind 36 0 0 10.8 Member38.564.16
10 180 SAE - 2.5X2.5X0.25 1.2D + 1.0W 90° Wind 36 0 0 9.9 Member38.563.82
11 200 SAE - 3X3X0.3125 1.2D + 1.0W 60° Wind 36 0 0 11.2 Member57.676.47
12 220 SAE - 3X3X0.3125 1.2D + 1.0W 90° Wind 36 0 0 10.7 Member57.676.15
13 240 SAE - 2.5X2.5X0.1875 1.2D + 1.0W Normal Wind 36 0 0 14.8 Member29.224.32
14 260 SAE - 3X3X0.25 1.2D + 1.0W 60° Wind 36 0 0 10.6 Member46.664.93
15 280 SAE - 3X3X0.25 1.2D + 1.0W 60° Wind 36 0 0 7.9 Member46.663.68
16 300 SAE - 2X2X0.25 1.2D + 1.0W 60° Wind 36 0 0 6.4 Member30.461.94
17 320 SAE - 2.5X2.5X0.25 1.2D + 1.0W 60° Wind 36 0 0 6.9 Member38.562.64
18 340 SAE - 2.5X2.5X0.25 1.2D + 1.0W 60° Wind 36 0 0 5.1 Member38.561.95
19 360 SAE - 2X2X0.25 1.2D + 1.0W Normal Wind 36 0 0 5.6 Member30.461.71
20 380 SAE - 2X2X0.25 1.2D + 1.0W Normal Wind 36 0 0 5.8 Member30.461.75
21 400 SAE - 2.5X2.5X0.1875 1.2D + 1.0W Normal Wind 36 0 0 4.8 Member29.221.39
22 420 SAE - 2X2X0.25 1.2D + 1.0W Normal Wind 36 0 0 4.1 Member30.461.25
23 440 SAE - 2X2X0.25 1.2D + 1.0W Normal Wind 36 0 0 4.0 Member30.461.22
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Force/Stress Tension Summary
Page: 19IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Member
Force
(kips)Load Case
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%Controls
Top
ElevSect
HORIZONTAL MEMBERS
B.S.
Cap
(kips)
24 450 SAE - 2.5X2.5X0.1875 1.2D + 1.0W Normal Wind 36 0 0 0.9 Member29.220.25
Member
Force
(kips)Load Case
Fy
(ksi)
Mem
Cap
(kips)
Num
Bolts
Num
Holes
Shear
Cap
(kips)
Bear
Cap
(kips)
Use
%Controls
Top
ElevSect
DIAGONAL MEMBERS
B.S.
Cap
(kips)
1 4 SOL - 3/4" SOLID 1.2D + 1.0W 60° Wind 50 0 0 11.8 Member19.882.34
2 20 SOL - 3/4" SOLID 1.2D + 1.0W 90° Wind 50 0 0 19.5 Member19.883.88
3 40 SOL - 3/4" SOLID 1.2D + 1.0W 60° Wind 50 0 0 8.8 Member19.881.75
4 60 SOL - 3/4" SOLID 0.9D + 1.0W 90° Wind 50 0 0 23.6 Member19.884.68
5 80 SOL - 3/4" SOLID 0.9D + 1.0W 90° Wind 50 0 0 26.0 Member19.885.16
6 100 SOL - 3/4" SOLID 1.2D + 1.0W Normal Wind 50 0 0 10.7 Member19.882.13
7 120 SOL - 7/8" SOLID 1.2D + 1.0W 90° Wind 50 0 0 24.2 Member27.066.56
8 140 PLT - 2"X1/2"1.2D + 1.0W 90° Wind 50 0 0 18.8 Member45.008.46
9 160 SOL - 7/8" SOLID 0.9D + 1.0W Normal Wind 50 0 0 20.5 Member27.065.55
10 180 SOL - 7/8" SOLID 50 0 00.000.00
11 200 PLT - 2"X5/8"1.2D + 1.0W 90° Wind 50 0 0 23.5 Member56.2513.21
12 220 PLT - 2"X5/8"0.9D + 1.0W Normal Wind 50 0 0 0.6 Member56.250.35
13 240 SOL - 3/4" SOLID 1.2D + 1.0W 90° Wind 50 0 0 32.5 Member19.886.46
14 260 PLT - 2"X1/2"1.2D + 1.0W 90° Wind 50 0 0 17.9 Member45.008.04
15 280 PLT - 2"X1/2"1.2D + 1.0W Normal Wind 50 0 0 7.5 Member45.003.39
16 300 SOL - 5/8" SOLID 1.2D + 1.0W 60° Wind 50 0 0 8.8 Member13.811.21
17 320 SOL - 7/8" SOLID 50 0 00.000.00
18 340 SOL - 7/8" SOLID 0.9D + 1.0W 60° Wind 50 0 0 7.6 Member27.062.07
19 360 SOL - 5/8" SOLID 0.9D + 1.0W 90° Wind 50 0 0 19.2 Member13.812.64
20 380 SOL - 5/8" SOLID 0.9D + 1.0W 60° Wind 50 0 0 6.1 Member13.810.84
21 400 SOL - 3/4" SOLID 0.9D + 1.0W 90° Wind 50 0 0 7.8 Member19.881.56
22 420 SOL - 5/8" SOLID 0.9D + 1.0W Normal Wind 50 0 0 1.8 Member13.810.25
23 440 SOL - 5/8" SOLID 1.2D + 1.0W Normal Wind 50 0 0 3.0 Member13.810.42
24 450 SOL - 3/4" SOLID 0.9D + 1.0W 60° Wind 50 0 0 7.8 Member19.881.54
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Seismic Section Forces
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Page: 20IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Dead Load Factor 1.20
1.00
Load Case: 1.2D + 1.0Ev + 1.0Eh
Seismic Load Factor
R 3.0000Seismic Importance Factor
S1
SsSds
Sd1
W1
0.053
40.044
80.000
0
0.0500
0.0280
1.00
Fv
Fa 1.6000
2.4000
Vs 2.3918
Kg
Ke 1.1504
0.0158
T 0.8008
TL 8.0000
Cs 0.0300
f1 1.2487
Sect
#
Elev
(ft)
Lateral
Fsz
(lbs)
Wz
(lb)
Vertical
Ev
(lbs)
2.00 1 0.12745.92 7.96
12.00 2 3.252170.1
5
23.16
30.00 3 12.282758.2
1
29.44
50.00 4 22.102758.2
1
29.44
70.00 5 39.303249.1
1
34.67
90.00 6 43.462758.2
1
29.44
110.00 7 59.472963.7
1
31.63
130.00 8 129.234923.7
5
52.55
150.00 9 76.462703.9
1
28.86
170.0010 88.302703.9
1
28.86
190.0011 234.665658.2
2
60.38
210.0012 129.703057.5
4
32.63
230.0013 302.545829.2
8
62.21
250.0014 129.022556.6
0
27.28
270.0015 125.042303.6
0
24.58
290.0016 70.201298.4
7
13.86
310.0017 107.701762.2
9
18.81
330.0018 226.453158.4
6
33.71
350.0019 74.131128.0
7
12.04
370.0020 79.751137.0
7
12.13
390.0021 197.852376.5
3
25.36
410.0022 88.931128.0
7
12.04
430.0023 93.931128.0
7
12.04
445.0024 57.94716.23 7.64
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Seismic Section Forces
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021Code:EIA/TIA-222-H
Exposure:C
Base Elev:0.000 (ft)
Page: 21IIStruct Class:Topography:1Gh:0.85
Crest Height:0.00
Site Class:D - Stiff Soil
Dead Load Factor 0.90
1.00
Load Case: 0.9D + 1.0Ev + 1.0Eh
Seismic Load Factor
R 3.0000Seismic Importance Factor
S1
SsSds
Sd1
W1
0.053
40.044
80.000
0
0.0500
0.0280
1.00
Fv
Fa 1.6000
2.4000
Vs 2.3918
Kg
Ke 1.1504
0.0158
T 0.8008
TL 8.0000
Cs 0.0300
f1 1.2487
Sect
#
Elev
(ft)
Lateral
Fsz
(lbs)
Wz
(lb)
Vertical
Ev
(lbs)
2.00 1 0.12745.92 7.96
12.00 2 3.252170.1
5
23.16
30.00 3 12.282758.2
1
29.44
50.00 4 22.102758.2
1
29.44
70.00 5 39.303249.1
1
34.67
90.00 6 43.462758.2
1
29.44
110.00 7 59.472963.7
1
31.63
130.00 8 129.234923.7
5
52.55
150.00 9 76.462703.9
1
28.86
170.0010 88.302703.9
1
28.86
190.0011 234.665658.2
2
60.38
210.0012 129.703057.5
4
32.63
230.0013 302.545829.2
8
62.21
250.0014 129.022556.6
0
27.28
270.0015 125.042303.6
0
24.58
290.0016 70.201298.4
7
13.86
310.0017 107.701762.2
9
18.81
330.0018 226.453158.4
6
33.71
350.0019 74.131128.0
7
12.04
370.0020 79.751137.0
7
12.13
390.0021 197.852376.5
3
25.36
410.0022 88.931128.0
7
12.04
430.0023 93.931128.0
7
12.04
445.0024 57.94716.23 7.64
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Support Forces Summary
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 22
Code:EIA/TIA-222-H
Exposure:C
Gh:0.85
Base Elev:0.000 (ft)
Crest Height:0.00
Site Class:
IIStruct Class:
D - Stiff Soil
Topography:1
Load Case
FX
(kips)
FY
(kips)
FZ
(kips)(-) = Uplift (+) = DownNode
1 0.00 388.091.2D + 1.0W Normal Wind -3.66
A1 0.00 -11.56 9.47
A1b 81.93 -82.31 -52.71
A1a -81.92 -82.29 -52.71
A5 0.00 -17.60 11.07
A5b 38.20 -52.45 -27.10
A5a -38.20 -52.46 -27.11
1 -3.16 399.941.2D + 1.0W 60° Wind -1.82
A1 -4.54 -38.34 42.20
A1b 34.27 -38.33 -25.03
A1a -109.90 -106.67 -63.45
A5 -4.33 -33.24 25.65
A5b 20.06 -33.25 -16.58
A5a -50.79 -65.01 -29.33
1 -3.50 393.461.2D + 1.0W 90° Wind -0.18
A1 -5.71 -59.34 68.88
A1b 16.14 -20.44 -11.80
A1a -103.78 -99.62 -57.29
A5 -5.29 -42.53 35.87
A5b 12.79 -23.26 -9.92
A5a -48.80 -61.01 -25.60
1 0.00 371.460.9D + 1.0W Normal Wind -3.73
A1 0.00 -11.65 9.56
A1b 81.98 -82.37 -52.73
A1a -81.97 -82.36 -52.73
A5 0.00 -17.67 11.13
A5b 38.23 -52.49 -27.12
A5a -38.23 -52.50 -27.12
1 -3.23 383.580.9D + 1.0W 60° Wind -1.86
A1 -4.54 -38.49 42.37
A1b 34.42 -38.49 -25.12
A1a -110.00 -106.81 -63.51
A5 -4.33 -33.32 25.72
A5b 20.11 -33.32 -16.61
A5a -50.83 -65.06 -29.34
1 -3.55 376.970.9D + 1.0W 90° Wind -0.16
A1 -5.71 -59.45 68.98
A1b 16.26 -20.57 -11.87
A1a -103.86 -99.71 -57.34
A5 -5.29 -42.59 35.92
A5b 12.85 -23.33 -9.95
A5a -48.83 -61.06 -25.62
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1 0.00 286.711.2D + 1.0Ev + 1.0Eh 0.01
A1 0.00 -42.50 53.95
A1b 48.01 -43.97 -27.72
A1a -48.01 -43.97 -27.72
A5 0.00 -20.50 18.07
A5b 16.34 -21.44 -9.43
A5a -16.34 -21.44 -9.43
1 0.00 270.000.9D + 1.0Ev + 1.0Eh 0.01
A1 0.00 -42.87 54.33
A1b 48.34 -44.34 -27.91
A1a -48.34 -44.34 -27.91
A5 0.00 -20.66 18.19
A5b 16.44 -21.60 -9.50
A5a -16.44 -21.60 -9.50
1 0.00 239.451.0D + 1.0W Normal Wind -0.73
A1 0.00 -28.13 34.71
A1b 40.80 -38.53 -24.31
A1a -40.80 -38.53 -24.31
A5 0.00 -16.06 13.75
A5b 15.94 -21.01 -9.90
A5a -15.94 -21.01 -9.90
1 -0.59 238.291.0D + 1.0W 60° Wind -0.34
A1 -0.65 -31.66 38.87
A1b 33.34 -31.66 -20.00
A1a -44.23 -41.53 -25.54
A5 -0.61 -17.81 15.41
A5b 13.05 -17.81 -8.23
A5a -17.32 -22.24 -10.00
1 -0.70 238.871.0D + 1.0W 90° Wind 0.01
A1 -0.80 -34.96 43.05
A1b 30.99 -29.25 -18.25
A1a -43.65 -40.80 -24.85
A5 -0.74 -19.35 17.04
A5b 12.18 -16.61 -7.39
A5a -17.28 -22.02 -9.62
Max Reactions (kips)
Vertical
Horizontal
Base Anchor 1 Anchor 2
399.94
3.73
106.81
127.01
65.06
58.69
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Cable Forces Summary
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 24
Code:EIA/TIA-222-H
Exposure:C
Gh:0.85
Base Elev:0.000 (ft)
Crest Height:0.00
Site Class:
IIStruct Class:
D - Stiff Soil
Topography:1
Load Case
Elevation
(ft) Cable Node 1 Node 2
Allow
Tension
(kips)
Applied
Tension
(kips)Use %
1.2D + 1.0W Normal
Wind
64.08 7/8 EHS A1 25 47.82 1.93 4
A1b 25a 47.82 13.86 29
A1a 25b 47.82 13.85 29
128.03 A1 T2 47.82 0.42 1
A1a T2b 47.82 15.36 32
A1b T2a 47.82 15.40 32
A1b T2 47.82 15.36 32
A1a T2a 47.82 15.40 32
A1 T2b 47.82 0.42 1
191.97 1 EHS A1 T3 62.70 2.50 4
A1a T3b 62.70 21.45 34
A1b T3a 62.70 21.63 35
A1b T3 62.70 21.40 34
A1a T3a 62.70 21.67 35
A1 T3b 62.70 2.50 4
255.93 A1 T4 62.70 5.00 8
A1a T4b 62.70 22.37 36
A1b T4a 62.70 22.06 35
A1b T4 62.70 22.39 36
A1a T4a 62.70 22.00 35
A1 T4b 62.70 5.00 8
324.07 A5 116 62.70 5.38 9
A5b 116a 62.70 24.67 39
A5a 116b 62.70 24.68 39
384.07 7/8 EHS A5 137 47.82 6.96 15
A5b 137a 47.82 21.46 45
A5a 137b 47.82 21.47 45
443.38 1 EHS A5 158 62.70 10.67 17
A5b 158a 62.70 26.51 42
A5a 158b 62.70 26.51 42
1.2D + 1.0W 60° Wind 64.08 7/8 EHS A1 25 47.82 6.49 14
A1b 25a 47.82 6.49 14
A1a 25b 47.82 18.21 38
128.03 A1 T2 47.82 7.03 15
A1a T2b 47.82 20.38 43
A1b T2a 47.82 6.74 14
A1b T2 47.82 7.03 15
A1a T2a 47.82 20.38 43
A1 T2b 47.82 6.74 14
191.97 1 EHS A1 T3 62.70 9.35 15
A1a T3b 62.70 27.87 44
A1b T3a 62.70 9.11 15
A1b T3 62.70 9.35 15
A1a T3a 62.70 27.87 44
A1 T3b 62.70 9.11 15
255.93 A1 T4 62.70 11.17 18
A1a T4b 62.70 28.11 45
A1b T4a 62.70 10.86 17
A1b T4 62.70 11.17 18
A1a T4a 62.70 28.12 45
A1 T4b 62.70 10.86 17
324.07 A5 116 62.70 13.96 22
A5b 116a 62.70 13.97 22
A5a 116b 62.70 30.58 49
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1.2D + 1.0W 60° Wind 384.07 7/8 EHS A5 137 47.82 13.18 28
A5b 137a 47.82 13.18 28
A5a 137b 47.82 26.75 56
443.38 1 EHS A5 158 62.70 17.36 28
A5b 158a 62.70 17.37 28
A5a 158b 62.70 32.57 52
1.2D + 1.0W 90° Wind 64.08 7/8 EHS A1 25 47.82 10.10 21
A1b 25a 47.82 2.89 6
A1a 25b 47.82 16.86 35
128.03 A1 T2 47.82 11.38 24
A1a T2b 47.82 19.10 40
A1b T2a 47.82 2.76 6
A1b T2 47.82 3.02 6
A1a T2a 47.82 18.72 39
A1 T2b 47.82 11.07 23
191.97 1 EHS A1 T3 62.70 15.22 24
A1a T3b 62.70 26.42 42
A1b T3a 62.70 4.51 7
A1b T3 62.70 4.73 8
A1a T3a 62.70 25.89 41
A1 T3b 62.70 14.98 24
255.93 A1 T4 62.70 16.40 26
A1a T4b 62.70 26.33 42
A1b T4a 62.70 6.76 11
A1b T4 62.70 6.98 11
A1a T4a 62.70 26.52 42
A1 T4b 62.70 16.00 26
324.07 A5 116 62.70 19.30 31
A5b 116a 62.70 8.44 13
A5a 116b 62.70 28.77 46
384.07 7/8 EHS A5 137 47.82 17.18 36
A5b 137a 47.82 9.13 19
A5a 137b 47.82 25.09 52
443.38 1 EHS A5 158 62.70 21.71 35
A5b 158a 62.70 13.04 21
A5a 158b 62.70 30.69 49
0.9D + 1.0W Normal
Wind
64.08 7/8 EHS A1 25 47.82 1.95 4
A1b 25a 47.82 13.82 29
A1a 25b 47.82 13.81 29
128.03 A1 T2 47.82 0.42 1
A1a T2b 47.82 15.39 32
A1b T2a 47.82 15.42 32
A1b T2 47.82 15.40 32
A1a T2a 47.82 15.43 32
A1 T2b 47.82 0.42 1
191.97 1 EHS A1 T3 62.70 2.52 4
A1a T3b 62.70 21.46 34
A1b T3a 62.70 21.64 35
A1b T3 62.70 21.44 34
A1a T3a 62.70 21.70 35
A1 T3b 62.70 2.52 4
255.93 A1 T4 62.70 5.04 8
A1a T4b 62.70 22.40 36
A1b T4a 62.70 22.09 35
A1b T4 62.70 22.38 36
A1a T4a 62.70 22.00 35
A1 T4b 62.70 5.03 8
324.07 A5 116 62.70 5.42 9
A5b 116a 62.70 24.68 39
A5a 116b 62.70 24.68 39
384.07 7/8 EHS A5 137 47.82 6.99 15
A5b 137a 47.82 21.48 45
A5a 137b 47.82 21.49 45
443.38 1 EHS A5 158 62.70 10.71 17
A5b 158a 62.70 26.54 42
A5a 158b 62.70 26.54 42
0.9D + 1.0W 60° Wind 64.08 7/8 EHS A1 25 47.82 6.51 14
A1b 25a 47.82 6.51 14
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
0.9D + 1.0W 60° Wind 64.08 7/8 EHS A1a 25b 47.82 18.18 38
128.03 A1 T2 47.82 7.06 15
A1a T2b 47.82 20.40 43
A1b T2a 47.82 6.76 14
A1b T2 47.82 7.06 15
A1a T2a 47.82 20.40 43
A1 T2b 47.82 6.76 14
191.97 1 EHS A1 T3 62.70 9.39 15
A1a T3b 62.70 27.90 45
A1b T3a 62.70 9.15 15
A1b T3 62.70 9.39 15
A1a T3a 62.70 27.90 45
A1 T3b 62.70 9.15 15
255.93 A1 T4 62.70 11.22 18
A1a T4b 62.70 28.17 45
A1b T4a 62.70 10.90 17
A1b T4 62.70 11.21 18
A1a T4a 62.70 28.16 45
A1 T4b 62.70 10.90 17
324.07 A5 116 62.70 14.00 22
A5b 116a 62.70 14.00 22
A5a 116b 62.70 30.59 49
384.07 7/8 EHS A5 137 47.82 13.21 28
A5b 137a 47.82 13.21 28
A5a 137b 47.82 26.77 56
443.38 1 EHS A5 158 62.70 17.40 28
A5b 158a 62.70 17.40 28
A5a 158b 62.70 32.60 52
0.9D + 1.0W 90° Wind 64.08 7/8 EHS A1 25 47.82 10.09 21
A1b 25a 47.82 2.91 6
A1a 25b 47.82 16.87 35
128.03 A1 T2 47.82 11.39 24
A1a T2b 47.82 19.10 40
A1b T2a 47.82 2.78 6
A1b T2 47.82 3.04 6
A1a T2a 47.82 18.73 39
A1 T2b 47.82 11.09 23
191.97 1 EHS A1 T3 62.70 15.24 24
A1a T3b 62.70 26.43 42
A1b T3a 62.70 4.54 7
A1b T3 62.70 4.76 8
A1a T3a 62.70 25.91 41
A1 T3b 62.70 15.01 24
255.93 A1 T4 62.70 16.44 26
A1a T4b 62.70 26.36 42
A1b T4a 62.70 6.80 11
A1b T4 62.70 7.02 11
A1a T4a 62.70 26.55 42
A1 T4b 62.70 16.04 26
324.07 A5 116 62.70 19.33 31
A5b 116a 62.70 8.47 14
A5a 116b 62.70 28.78 46
384.07 7/8 EHS A5 137 47.82 17.21 36
A5b 137a 47.82 9.16 19
A5a 137b 47.82 25.11 53
443.38 1 EHS A5 158 62.70 21.74 35
A5b 158a 62.70 13.07 21
A5a 158b 62.70 30.72 49
1.2D + 1.0Ev + 1.0Eh 64.08 7/8 EHS A1 25 47.82 11.20 23
A1b 25a 47.82 11.29 24
A1a 25b 47.82 11.29 24
128.03 A1 T2 47.82 9.70 20
A1a T2b 47.82 9.88 21
A1b T2a 47.82 9.89 21
A1b T2 47.82 9.88 21
A1a T2a 47.82 9.89 21
A1 T2b 47.82 9.70 20
191.97 1 EHS A1 T3 62.70 10.94 17
A1a T3b 62.70 11.31 18
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1.2D + 1.0Ev + 1.0Eh 191.97 1 EHS A1b T3a 62.70 11.32 18
A1b T3 62.70 11.31 18
A1a T3a 62.70 11.32 18
A1 T3b 62.70 10.94 17
255.93 A1 T4 62.70 9.99 16
A1a T4b 62.70 10.44 17
A1b T4a 62.70 10.44 17
A1b T4 62.70 10.44 17
A1a T4a 62.70 10.44 17
A1 T4b 62.70 9.99 16
324.07 A5 116 62.70 10.96 17
A5b 116a 62.70 11.48 18
A5a 116b 62.70 11.48 18
384.07 7/8 EHS A5 137 47.82 8.09 17
A5b 137a 47.82 8.48 18
A5a 137b 47.82 8.48 18
443.38 1 EHS A5 158 62.70 10.53 17
A5b 158a 62.70 10.85 17
A5a 158b 62.70 10.85 17
0.9D + 1.0Ev + 1.0Eh 64.08 7/8 EHS A1 25 47.82 11.22 23
A1b 25a 47.82 11.31 24
A1a 25b 47.82 11.31 24
128.03 A1 T2 47.82 9.75 20
A1a T2b 47.82 9.94 21
A1b T2a 47.82 9.94 21
A1b T2 47.82 9.94 21
A1a T2a 47.82 9.94 21
A1 T2b 47.82 9.75 20
191.97 1 EHS A1 T3 62.70 11.04 18
A1a T3b 62.70 11.41 18
A1b T3a 62.70 11.42 18
A1b T3 62.70 11.41 18
A1a T3a 62.70 11.42 18
A1 T3b 62.70 11.04 18
255.93 A1 T4 62.70 10.09 16
A1a T4b 62.70 10.54 17
A1b T4a 62.70 10.55 17
A1b T4 62.70 10.54 17
A1a T4a 62.70 10.55 17
A1 T4b 62.70 10.09 16
324.07 A5 116 62.70 11.03 18
A5b 116a 62.70 11.55 18
A5a 116b 62.70 11.55 18
384.07 7/8 EHS A5 137 47.82 8.14 17
A5b 137a 47.82 8.54 18
A5a 137b 47.82 8.54 18
443.38 1 EHS A5 158 62.70 10.60 17
A5b 158a 62.70 10.92 17
A5a 158b 62.70 10.92 17
1.0D + 1.0W Normal
Wind
64.08 7/8 EHS A1 25 47.82 6.60 14
A1b 25a 47.82 8.37 17
A1a 25b 47.82 8.37 17
128.03 A1 T2 47.82 5.96 12
A1a T2b 47.82 8.06 17
A1b T2a 47.82 8.02 17
A1b T2 47.82 8.06 17
A1a T2a 47.82 8.02 17
A1 T2b 47.82 5.96 12
191.97 1 EHS A1 T3 62.70 7.39 12
A1a T3b 62.70 10.19 16
A1b T3a 62.70 10.14 16
A1b T3 62.70 10.19 16
A1a T3a 62.70 10.13 16
A1 T3b 62.70 7.39 12
255.93 A1 T4 62.70 7.35 12
A1a T4b 62.70 10.04 16
A1b T4a 62.70 9.90 16
A1b T4 62.70 10.04 16
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1.0D + 1.0W Normal
Wind
255.93 1 EHS A1a T4a 62.70 9.90 16
A1 T4b 62.70 7.34 12
324.07 A5 116 62.70 8.41 13
A5b 116a 62.70 10.83 17
A5a 116b 62.70 10.83 17
384.07 7/8 EHS A5 137 47.82 6.17 13
A5b 137a 47.82 8.53 18
A5a 137b 47.82 8.53 18
443.38 1 EHS A5 158 62.70 8.82 14
A5b 158a 62.70 11.06 18
A5a 158b 62.70 11.06 18
1.0D + 1.0W 60° Wind 64.08 7/8 EHS A1 25 47.82 7.16 15
A1b 25a 47.82 7.16 15
A1a 25b 47.82 8.86 19
128.03 A1 T2 47.82 6.65 14
A1a T2b 47.82 8.60 18
A1b T2a 47.82 6.60 14
A1b T2 47.82 6.65 14
A1a T2a 47.82 8.60 18
A1 T2b 47.82 6.59 14
191.97 1 EHS A1 T3 62.70 8.34 13
A1a T3b 62.70 10.96 17
A1b T3a 62.70 8.27 13
A1b T3 62.70 8.34 13
A1a T3a 62.70 10.96 17
A1 T3b 62.70 8.27 13
255.93 A1 T4 62.70 8.33 13
A1a T4b 62.70 10.74 17
A1b T4a 62.70 8.18 13
A1b T4 62.70 8.33 13
A1a T4a 62.70 10.74 17
A1 T4b 62.70 8.18 13
324.07 A5 116 62.70 9.16 15
A5b 116a 62.70 9.16 15
A5a 116b 62.70 11.43 18
384.07 7/8 EHS A5 137 47.82 7.10 15
A5b 137a 47.82 7.10 15
A5a 137b 47.82 9.03 19
443.38 1 EHS A5 158 62.70 9.55 15
A5b 158a 62.70 9.55 15
A5a 158b 62.70 11.70 19
1.0D + 1.0W 90° Wind 64.08 7/8 EHS A1 25 47.82 7.75 16
A1b 25a 47.82 6.76 14
A1a 25b 47.82 8.74 18
128.03 A1 T2 47.82 7.36 15
A1a T2b 47.82 8.46 18
A1b T2a 47.82 6.14 13
A1b T2 47.82 6.15 13
A1a T2a 47.82 8.46 18
A1 T2b 47.82 7.29 15
191.97 1 EHS A1 T3 62.70 9.26 15
A1a T3b 62.70 10.76 17
A1b T3a 62.70 7.66 12
A1b T3 62.70 7.67 12
A1a T3a 62.70 10.77 17
A1 T3b 62.70 9.16 15
255.93 A1 T4 62.70 9.15 15
A1a T4b 62.70 10.53 17
A1b T4a 62.70 7.63 12
A1b T4 62.70 7.68 12
A1a T4a 62.70 10.59 17
A1 T4b 62.70 8.96 14
324.07 A5 116 62.70 9.96 16
A5b 116a 62.70 8.62 14
A5a 116b 62.70 11.32 18
384.07 7/8 EHS A5 137 47.82 7.82 16
A5b 137a 47.82 6.47 14
A5a 137b 47.82 8.95 19
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1.0D + 1.0W 90° Wind 443.38 1 EHS A5 158 62.70 10.26 16
A5b 158a 62.70 9.04 14
A5a 158b 62.70 11.58 18
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Analysis Summary
Structure:FL04816-A-SBA
Site Name:Swain Road Tower
Height:450.00 (ft)
9/1/2021
Page: 30
Code:EIA/TIA-222-H
Exposure:C
Gh:0.85
Base Elev:0.000 (ft)
Crest Height:0.00
Site Class:
IIStruct Class:
D - Stiff Soil
Topography:1
Max Reactions
Base:
Anchor 1:
Anchor 2:
399.94 (Vertical)3.73 (Horizontal)
106.81 (Vertical)
65.06 (Vertical)
127.01 (Horizontal)
58.69 (Horizontal)
Max Usages
Max Leg: 59.3% (1.2D + 1.0W 60° Wind - Sect 13)
Max Diag: 32.5% (1.2D + 1.0W 90° Wind - Sect 13)
Max Horiz: 65.1% (1.2D + 1.0W 60° Wind - Sect 1)
Max Cable: 56.0% (0.9D + 1.0W 60° Wind) - Elev: 384 ft
Load Case
Elevation
(ft)
Deflection
(ft)
Twist
(deg)
Sway
(deg)
Max Deflection, Twist and Sway
0.9D + 1.0Ev + 1.0Eh - Normal To Face 115.92 0.0035 0.0000 0.0031
128.03 0.0042 0.0000 0.0043
191.97 0.0090 0.0000 0.0074
200.00 0.0098 0.0000 0.0083
231.97 0.0132 0.0000 0.0056
255.93 0.0152 0.0000 0.0076
375.93 0.0284 0.0001 0.0011
450.00 0.0226 0.0000 0.0103
0.9D + 1.0W 158 mph Wind at 60° From Face 115.92 0.3535 0.0038 0.1156
128.03 0.3742 0.0007 0.1584
191.97 0.6088 0.0017 0.2507
200.00 0.6518 0.0023 0.3407
231.97 0.7968 0.0051 0.1784
255.93 0.8389 0.0041 0.1598
375.93 1.3918 0.0238 0.2526
450.00 1.6102 0.0380 0.1153
0.9D + 1.0W 158 mph Wind at 90° From Face 115.92 0.3561 0.0659 0.1347
128.03 0.3794 0.0544 0.1826
191.97 0.6446 0.0805 0.2588
200.00 0.6836 0.0776 0.3672
231.97 0.8272 0.0590 0.1752
255.93 0.8597 0.0445 0.1329
375.93 1.2927 0.3639 0.1985
450.00 1.4298 0.3877 0.1264
0.9D + 1.0W 158 mph Wind at Normal To Face 115.92 0.3591 -0.0023 0.1177
128.03 0.3833 -0.0024 0.2014
191.97 0.6901 -0.0053 0.2918
200.00 0.7404 -0.0035 0.4336
231.97 0.8914 0.0098 0.1668
255.93 0.9237 0.0199 0.1153
375.93 1.2137 0.0567 0.1101
450.00 1.2434 0.0853 0.0673
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
1.0D + 1.0W 60 mph Wind at 60° From Face 115.92 0.0361 0.0002 0.0065
128.03 0.0373 0.0002 0.0100
191.97 0.0520 0.0002 0.0127
200.00 0.0543 0.0002 0.0212
231.97 0.0599 0.0004 0.0015
255.93 0.0566 0.0004 0.0096
375.93 0.0469 0.0028 0.0141
450.00 0.0127 0.0053 0.0462
1.0D + 1.0W 60 mph Wind at 90° From Face 115.92 0.0344 0.0034 0.0053
128.03 0.0352 0.0029 0.0087
191.97 0.0472 0.0042 0.0104
200.00 0.0491 0.0046 0.0179
231.97 0.0526 0.0070 0.0117
255.93 0.0477 0.0089 0.0213
375.93 0.0525 0.0334 0.0344
450.00 0.0859 0.0409 0.0694
1.0D + 1.0W 60 mph Wind at Normal To Face 115.92 0.0342 0.0002 0.0027
128.03 0.0347 0.0002 0.0074
191.97 0.0438 0.0004 0.0067
200.00 0.0449 0.0004 0.0154
231.97 0.0450 0.0008 0.0135
255.93 0.0357 0.0010 0.0256
375.93 0.0286 0.0072 0.0452
450.00 0.1001 0.0123 0.0657
1.2D + 1.0Ev + 1.0Eh - Normal To Face 115.92 0.0035 0.0000 0.0031
128.03 0.0042 0.0000 0.0043
191.97 0.0090 0.0000 0.0075
200.00 0.0098 0.0000 0.0084
231.97 0.0132 0.0000 0.0057
255.93 0.0153 0.0000 0.0076
375.93 0.0285 0.0001 0.0011
450.00 0.0227 0.0000 0.0102
1.2D + 1.0W 158 mph Wind at 60° From Face 115.92 0.3583 -0.0033 0.0912
128.03 0.3754 -0.0005 0.1581
191.97 0.6110 -0.0012 0.2519
200.00 0.6543 -0.0016 0.3424
231.97 0.7998 -0.0036 0.1791
255.93 0.8419 -0.0020 0.1601
375.93 1.3969 0.0437 0.2524
450.00 1.6149 0.0546 0.1152
1.2D + 1.0W 158 mph Wind at 90° From Face 115.92 0.3580 0.0668 0.1363
128.03 0.3815 0.0545 0.1845
191.97 0.6489 0.0814 0.2606
200.00 0.6881 0.0785 0.3694
231.97 0.8326 0.0599 0.1764
255.93 0.8651 0.0455 0.1333
375.93 1.2972 0.3563 0.1986
450.00 1.4339 0.3817 0.1271
1.2D + 1.0W 158 mph Wind at Normal To Face 115.92 0.3605 0.0009 0.0818
128.03 0.3846 0.0011 0.2060
191.97 0.6953 0.0012 0.2938
200.00 0.7457 0.0016 0.4358
231.97 0.9029 0.0046 0.1777
255.93 0.9330 0.0073 0.1163
375.93 1.2216 0.0493 0.1079
450.00 1.2484 0.0792 0.0651
Copyright © 2021 by Tower Engineering Solutions, LLC. All rights reserved.
Customer Name:
Site Name:
Site Nmber:
Engr. Number:
Foundation Info Obtained from:4.0
1.00
Axial Load (Kips): 399.9 Shear Force (Kips): 3.7
#5
Uplift Force (Kips): 0.0 Moment (Kips‐ft):2.5
Allowable overstress %:5.0%
Foundation Geometries:5.0 16 # 10
Mods required ‐Yes/No ?: No 16 # 10
4.0 Depth of Base BG (ft.): 5.0
Pier Height A. G. (ft.): 1.00 Thickness of Pad (ft): 3.25
3.25
Length of Pad (ft.): 16.5 Width of Pad (ft.): 16.5
16.5
Final Length of pad (ft) 16.5 Final width of pad (ft): 16.5 0.0
4.0
Concrete Strength (psi): 3000 Steel Elastic Modulus: 29000 ksi
Vertical bar yield (ksi) 60 Tie steel yield (ksi): 60
16.5
Vertical Rebar Size #: 8 Tie / Stirrup Size #: 5
16.5 W
Qty. of Vertical Rebars: 12 Tie Spacing (in): 6.0
Pad Rebar Yield (Ksi): 60 Pad Steel Rebar Size (#): 10 12 # 8
Concrete Cover (in.): 3 Unit Weight of Concrete: 150.0 pcf
Rebar at the bottom of the concrete pad:0.0
Qty. of Rebar in Pad (L): 16 Qty. of Rebar in Pad (W): 16 0.0 0.0
16.5 L
Soil Design Parameters:
Soil Unit Weight (pcf): 110.0 Soil Buoyant Weight: 47.6 Pcf
Water Table B.G.S. (ft): 2.5 Unit Weight of Water: 62.4 pcf Angle from Top of Pad: 30
Ultimate Bearing Pressure (psf): 5000 Ultimate Skin Friction: 0 Psf Angle from Bottm of Pad:25
Angle from Bottm of Pad: 25
Foundation Analysis and Design:Uplift Strength Reduction Factor: 0.75 Compression Strength Reduction Factor: 0.6
454.45 Total Dry Soil Weight (Kips): 49.99
0.00 Total Buoyant Soil Weight (Kips): 0.00
49.99 Weight from the Concrete Block at Top (K):0.00
238.75 Total Dry Concrete Weight (Kips): 35.81
680.63 Total Buoyant Concrete Weight (Kips): 59.62
95.43 Total Vertical Load on Base (Kips): 545.36
Load/
Capacity
Ratio
Calculated Maxium Net Soil Pressure under the base (psf): 1776.0 < Allowable Factored Soil Bearing (psf): 3000
0.59 OK!
Calculated Foundation Allowable Axail Capacity (Kips):816.8 >Design Factored Axial Load (Kips):497 0.61 OK!
Structure Type:
Base Reactions (Factored):
Diameter of Pier (ft.):
Analysis
Total Buoyant Soil Volume (cu. Ft.):
TES
Swain Road Tower
Drawings/Calculations
Total Effective Soil Weight (Kips):
Total Dry Concrete Volume (cu. Ft.):
Total Buoyant Concrete Volume (cu. Ft.):
Total Effective Concrete Weight (Kips):
SBA Communications Corp
114400
Analysis or Design?
Material Properties and Reabr Info:
FL04816-A-SBA
Engineer Login ID:
Check Soil Capacities:
Total Dry Soil Volume (cu. Ft.):
Guyed Tower
9/1/2021Guyed Tower Base Design Date
Engineer Name:
EIA/TIA Standard:EIA-222-H
Structure Height (Ft.):450
W. Velez
TES Engr. Number:Page 2/2 Date:
Check the capacities of Reinforceing Concrete:
Strength reduction factor (Flexure and axial tension): 0.90 Strength reduction factor (Shear): 0.75
Strength reduction factor (Axial compresion): 0.65 Wind Load Factor on Concrete Design: 1.00
(1) Concrete Pier:
Load/
Capacity
Ratio
Vertical Steel Rebar Area (sq. in./each): 0.79 Tie / Stirrup Area (sq. in./each):0.31
Calculated Moment Capacity (Mn,Kips‐Ft): 857.3 >Design Factored Moment (Mu, Kips‐Ft 10.3 0.01 OK!
Calculated Shear Capacity (Kips): 386.8 >Design Factored Shear (Kips):3.7 0.01 OK!
Calculated Tension Capacity (Tn, Kips): 511.9 >Design Factored Tension (Tu Kips):0.0 0.00 OK!
Calculated Compression Capacity (Pn, Kips): 2386.9 >Design Factored Axial Load (Pu Kips):399.9 0.17 OK!
Moment & Axial Strength Combination(Pu/Pn+Mu/Mn): 0.18 OK!
Pier Reinforcement Ratio: 0.005
(2).Concrete Pad:
One‐Way Design Shear Capacity (L‐Dir. Kips); 575.5 >One‐Way Factored Shear (L‐Dir Kips): 87.7 0.15 OK!
One‐Way Design Shear Capacity (W‐Dir. Kips): 575.5 >One‐Way Factored Shear (W‐Dir Kips) 87.7
0.15 OK!
Two‐Way Design Shear Capacity (Kips): 1522.5 >Two‐Way Factored Shear (Kips): 342.6 0.23 OK!
Lower Steel Pad Reinforcement Ratio (L‐Direct. ): 0.0029 OK!Lower Steel Pad Reinf. Ratio (W‐Direc 0.0029 OK!
Lower Steel Pad Moment Capacity (L‐Direction. Kips‐ft): 3124.3 >Moment at Bottom ( L‐Direct. K‐Ft): 518.6 0.17 OK!
Lower Steel Pad Moment Capacity (W‐Dir. Kips‐ft): 3124.3 >Moment at Bottom ( W‐Dir. Kips‐Ft): 518.6 0.17 OK!
9/1/2021114400
Customer Name:
Site Name:
Site Nmber:
Engr. Number:
Foundation Info Obtained from:Failure model: New
Soil Design Parameters:
Soil Unit Weight (pcf):105.0 Soil Buoyant Weight:42.6 Pcf Cohesion of Soils (psf): 0
Water Table B.G.S. (ft):2.0 Unit Weight of Water:62.4 pcf Internal Angle of Friction (⁰)29
Ultimate lateral pressure (psf): 1600 Ultimate Skin Friction:0 Psf Coefficient of Shear Friction:
Conical Failure Angle from Top:30 Failure Angle from Bottm 25
Material Properties:
Concrete Strength (psi):3000 Unit Weight of Concrete:150.0 psf Horizontal Rebar Yield (psi): 60000
Shear Strength Reduction Factor:0.75 Flexure Strength Reduction Factor: 0.9
A. Inner Anchors:
Radius (ft.):200
1. Design Reactions (Factored):
Uplift (Kips:)106.8 Shear (Kips)127.0 Angle of force resultant (Ø ): 40.1
2. Foundation Geometries:
Block Base Depth B.G.S. (ft):12.0 Block with/without toe?No Water Table below grade (ft): 2.00
Length of Anchor Block (L, ft.):36.0 Width of Anchor Block:6.0 ft. Thickness of Anchor Block (ft.): 6.0
Concrete Block @ top of Anchor? No
(1). Inner Anchors:Radius (ft.): 200 Concrete Block ΔW x ΔL x ΔT
H (ft.): 12.0 Hw(ft.): 2.0
L (ft.): 36.0 W (ft.): 6.0 ΔT
T (ft.): 6.0 Angle (Ø ): 40.1
S (ft.): 19.42
Top bars:8#8
Front bars: 8 # 8
Concrete Volume (Cu. Yd.)/Each: 48.00 S
Hw
Top Bars
(2). Outer Anchors:Radius (ft.): 315.0
H (ft.): 12.0 Hw(ft.): 2.0 H
L (ft.): 17.0 W (ft.): 5.0
T (ft.): 3.0 Angle (Ø ): 47.9
S (ft.): 16.83 T
Top bars: 5 # 7 Front Bars
Front bars: 3 # 7
Concrete Volume (Cu. Yd.)/Each:9.44
W
114400 Page 2/2
Angle (Ø )
TES Engr. Number:Date:09/01/21
Drawings/Calculations Number of Anchors:2 Sets
FL04816-A-SBA Engineer Name:W. Velez
114400 Engineer Login ID:TES
Guy Anchor Analysis and Design Date
9/1/2021
SBA Communications Corp EIA/TIA Standard:EIA-222-H
Swain Road Tower Structure Height (Ft.):450
3. Foundation Analysis and Design:
970.03 Total Dry Soil Weight (Kips):153.25
3050.20 Total Buoyant Soil Weight (Kips):129.94
156.14 Weight of the Concrete Block at Top (Kips):0.00
0.00 Total Dry Concrete Weight (Kip):0.00
1296.00 Total Buoyant Concrete Weight (Kips):113.53
113.53 Weight Reduction Factor: 0.9
0.75 Shear Strength Reduction Factor:0.75
0.9
4. Check Soil and Foundation Capacities:
Nominal Factored Uplift Resistance:257.77 Kips >Design Uplift Force (Kips): 106.8
OK!
Ultimate Shear Friction Resistance at base:0.00 Kips Ultimate Resistance Pressure: 1600.0 Psf
Factored Shear Resistance:259.20 Kips >Design Shear Force (Kips):127.0 OK!
5. Design Concrete Block:
Rebar Size (#):8 Wind Load Factor on Concrete Design:1.00
Qty. of the Rebar at top of the block:8 Qty. of the Rebar in the front of the block:8
Area of Single Rebar (sq. in.):0.79 Factor for concrete compression zone:0.85
One Way Shear due to Shear Force (Kips): 63.5 One Way Shear Capacity for shear (kips):402.2 OK!
One Way Shear due to Uplift (Kips): 53.4 One Way Shear Capacity for uplift (kips):402.2 OK!
Moment due to Shear Load ( Kips‐ft):571.5 Flexural Capacity for Shear Load (Kips‐ft):1933.5 OK!
Moment due to uplift Load ( Kips‐ft):480.6 Flexural Capacity for uplift Load (Kips‐ft):1933.5 OK!
Ratio of Design Moment/Moment capacity:0.30 0.18 OK!
Max. Ratio of Shear Force/Shear capacity:0.16 OK!
B. Outer Anchors:
315.0
1. Design Reactions (Factored):
Uplift (Kips:)65.1 Shear (Kips):58.7 Angle of force resultant (Ø ):47.9
2. Foundation Geometries:
Block Base Depth B.G.S. (ft):12.0 Block with/without toe?No Water Table below grade (ft):2.0
Length of Anchor Block (L, ft.):17.0 Width of Anchor Block:5.0 ft. Thickness of Anchor Block (ft.):3.0
Concrete Block @ top of Anchor?
3. Foundation Analysis and Design:
711.2 Total Dry Soil Weight (Kips):82.7
1848.6 Total Buoyant Soil Weight (Kips):78.7
161.4 Weight of the Concrete Block at Top (Kips):0.0
0.0 Total Dry Concrete Weight (Kip):0.0
255.0 Total Buoyant Concrete Weight (Kips):22.3
22.3
4. Check Soil and Foundation Capacities:
Nominal Factored Uplift Resistance:134.68 Kips >Design Uplift Force (Kips):65.1 OK!
Ultimate Shear Friction Resistance at base:0.00 Kips Ultimate Resistance Pressure:1600.0 Psf
Factored Shear Resistance:61.20 Kips >Design Shear Force (Kips):58.7 OK!
5. Design Concrete Block:
Rebar Size (#):7
Qty. of the Rebar at top of the block:5 Qty. of the Rebar in the front of the block:3
Area of Single Rebar (sq. in.):0.60 Factor for concrete compression zone:0.85
One Way Shear due to Shear Force (Kips):29.3 One Way Shear Capacity for shear (kips):165.6 OK!
One Way Shear due to Uplift (Kips):32.5 One Way Shear Capacity for uplift (kips):157.7 OK!
Moment due to Shear Load ( Kips‐ft):124.7 Flexural Capacity for Shear Load (Kips‐ft):453.5 OK!
Moment due to uplift Load ( Kips‐ft):138.3 Flexural Capacity for uplift Load (Kips‐ft):431.8 OK!
Ratio of Design Moment/Moment capacity:0.32 0.13
Max. Ratio of Shear Force/Shear capacity:0.21 OK!
Total Effective Soil Weight (Kips):
Total Dry Concrete Volume (cu. Ft.):
Total Buoyant Concrete Volume (cu. Ft.):
Total Effective Concrete Weight (Kips):
Minimum ratio of rebar (top of front) :
Minimum ratio of rebar (top & front) :
Radius (ft.):
Total Dry Soil Volume (cu. Ft.):
Total Buoyant Soil Volume (cu. Ft.):
Total Effective Concrete Weight (Kips):
Soil Uplift Strength Reduction Factor A:
Soil Uplift Strength Reduction Factor B:
Total Dry Concrete Volume (cu. Ft.):
Total Buoyant Concrete Volume (cu. Ft.):
Total Buoyant Soil Volume (cu. Ft.):
Total Effective Soil Weight (Kips):
Total Dry Soil Volume (cu. Ft.):