HomeMy WebLinkAboutAPPROVED, UnderlaymentNEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 to Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT GAF Evaluation Report 01506.04.08-R23 1Campus Drive FL10626-R23 Parsippany, NJ 07054 Date of Issuance: 04/25/2008 (800) 766-3411 Revision 23: 12/14/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 711 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ❑; • fir. Robert J.M. Nieminen P.E.'- r ° '` , la ': ::.� ��-jTr The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Nieminen, P.E. on 12/14/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC ONEMOletc. ROOFING COMPONENT EVALUATION: SCOPE:1. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the 7' Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2C11 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, Material standard ASTM D1970 2415 R905.2.8.2 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tear Strength ASTM D4533 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tensile strength ASTM D5035 2011 R905.1,1,1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1 / R905.1.1 Material standard ASTM D6757 2016 1507.3.3, R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507,11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity Examination Reference bate ERD (TST6049) ASTM D1623 & FRSA/TRI (Slippage) G34150.08.11 11/14/11 ERD (TST6049) ASTM DE164 (GA) G40630.01.14-28-R2 01/07/14 ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3A 09/09/14 ERD (TST6049) ASTM D1970 (GA) GAF-SC13285.03.17-3 03/01/17 ERD (TST6049) ASTM D1970 (GA) GAF-SC13285.03.17-4 03/01/17 ERD (TST6049) ASTM D1970 (GA) GAF-SC13285.03.17-1 03/08/17 ERD (TST6049) ASTM D1970 (IN) GAF-SC16440.12.17 12/31/17 Intertek {TST1558) ASTM D4869 (Dadra, India) F8549.02-106-18 11/08/16 MEMO (TST6049) Physical Properties (ON) 4q-GAF-I9-SSMBB-03.A 05/13/19 NEMO (TST6049) ASTM D1623 4p-DOW-I9-SSLAP-0I.A-112 10/01/19 MEMO (TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/20 NEMO (TST6049) ASTM D1970 4j-GAF-20-SSUDL-01.A 12/22/20 NEMO (TST6049) ASTM D4798, TAS 103 4j-GAF-20-SSUDL-02.A 03/15/21 NEMO (TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/21 PRI (TST5878) ASTM D226 (OK) GAF-339-02-01 03/13/12 PRI (TST5878) Wind Uplift GAF-434-02-01 09/16/13 PRI (TST5878) Wind Uplift GAF-434-02-03 09/16/13 PRI (TST5878) Wind Uplift GAF-434-02-04 09/16/13 PRI (TST5878) ASTM D4533 (various) GAF-818-02-01 12/05/17 PRI {TST5878) ASTM D1970 (AL) MSA-047-02-01 04/11/18 PRI (TST5878) ASTM D4533 (Dadra, India) GAF-847-02-01 06/04/18 PRI (TST5878) ASTM D4533 (Dadra, India) GAF-914-02-01 04/10/19 PRI (TST5878) ASTM D4533,D5035(VA) 376T0012 07/15/19 PRI (TST5878) ASTM D4533 (Parzai, India) 376T0018 07/31/19 PRI (TST5878) ASTM D4533 (Umerkui Kilvani, India) I 376T0018 07/31/19 PRI (TST5878) ASTM D1970(AR) 376T0032 10/22/19 PRI (T5T5878) ASTM D4533 (Gujarat, India) 376T0058 02/18/20 NEIVIO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization #32455 7'H EDITION (2020) F3C NON-HVHZ EVALUATION F1.10626-1323 GAF Roof Underlayments Revision 23: 22/14/2021 Page 2 of 8 M 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 Entity Examination NNEMOletc. (Reference Date PRI (TST5878) ASTM D226(S-CA) 376T0054 02/18/20 PRI (TST5878) ASTM D5035 (various) 376TO103 D9/11/20 PRI (TST5878) ASTM D4533, D5035 (Rajasthan, India) 376TO111 12/22/20 PRI (TST5878) ASTM D4533, D5035 (Gujarat, India) 376TO113 12/22/20 PRI (TST5878) ASTM D5035 (Gujarat, India) 376TO146 03/11/21 PRI (TST5878) ASTM D4533, D5035 (Rajasthan, India) 376TO161 05/07/21 PRI (TST5878) ASTM D226,Type 11 376TO192 09/16/21 NEMO Traceability FBC Cross -Listing 04/22/20 NEMO Traceability FBC Cross -Listing 04/08/21 UL, LLC (QLIA9625) Quality Control Service Confirmation (AL) 05/04/20 UL, LLC (QUA9625) Quality Control Service Confirmation (various) 06/10/21 UL, LLC (QUA9625) I Quality Control Florida BCIS Current PRODUCTDESCRIPTION: Product Material Standard Plant(s) GAF Extended Dry -In Membrane ASTM 01970 Langley, BC Canada Liberty'" SBS Self -Adhering Base/Ply ASTM D1970 Mt. Vernon, IN Sheet Savannah, GA StormGuard® Film -Surfaced Leak Barrier ASTM D1970 (Table 1) 1 Mt. Vernon, IN Savannah, GA ® WeatherWatch Mineral Surfaced Leak Arkadelphia, AR Barrier ASTM D1970 Savannah, GA Tuscaloosa, AL Deck -Armor'" Premium Breathable Roof 1507,1.1.1(2&3, Exception) / Deck Protection R905.1.1.1(2&3, Exception) Dadra, India Dadra, India 1507.1.1.1(2&3, Exception), Gujarat, India feltBuster® Synthetic Roofing Felt 1507.1.1.1(5) / R905.1.1.1(2&3, (CPP) Rajasthan, India Exception), R905.1.1.1(5) (MIP} Rajasthan, India Richmond, VA Spartanburg, SC Shingle -Mate® Roof Deck Protection ASTM D226, Type II (Table 1) Pryor, OK Shafter, CA 5tormSafe`"' Anchor Sheet 1507.1.1.1(2&3, Exception) / North Bay, ON R905.1.1.1(2&3, Exception) Dadra, India Tiger Paw— Premium Roof Deck 1507.1.1.1(2&3, Exception) / Gujarat, India Protection R905.1.1.1(2&3, Exception) Parzai, India Umerkui Kilvani, India VersaShield® Fire -Resistant Roof Deck Protection ASTM D226, Type II Conover, NC Ruberoid® Mop Granule ASTM D6164 Savannah, GA FRSA/TR109-18 Ruberoid® Mop Granule FR ASTM D6164 Savannah, GA FRSA/TRI09-18 StormGuard ® Film -Surfaced Leak Barrier has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt when tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. NEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization 932455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23: 12/14/2021 Page 3 of 8 NNEMO I etc. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering, 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS F8CSection. 1507.1 1507.3 1507.4 and 1507.5 1507.7 IS07.8and 1507.9 Clay and Concrete Tile Metal Slate or ''Hood Underlayment Asphalt Shingles Slate -Type Mechanical Adhesive- Attach Set Panels Shingles Shingles Shingles Shakes Yes Yes GAF Extended Dry -In Membrane Yes No No Yes Yes Yes liointstrips, Uofntstrlps, 1507.1.1.3 / 1507.1.1.31 R905.1.1.31 R905.1.1.3) Yes Yes Liberty" SBSSeIf-Adhering Yes No No NO No No (joint strips, lioint strips, Base/Ply Sheet 1507.1.1.3 / 1507,1,1.3 / R905.1.1.3) R905.1.1.3) Yes Yes StormGuardm Film -Surfaced Leak Barrier Yes No No Yes Yes Yes 1507.1.13/ 15o7.i1.3nint s/ R905.1.1.3) R9051.1.3) Yes Yes WeatherWatch® Mineral -Surfaced Leak Barrier Yes No No No No No 15071.1.31 1507.1.13/ 11905.1.1.31 R905.1.1.3) Deck -Armor"" Premium Breathable Roof Deck Protection yes No No Yes Yes Yes No No FeltBuster* Synthetic Roofing Felt Yes No No No No No No No Shingle- Mate' Roof Deck Protection Yes No No Na No No No No Tiger Paw'" Premium Roof Deck Protection Yes No No Yes Yes Yes No No VersaShield® Fire -Resistant Roof Deck Protection Yes No No No No No No No Yes Yes Ruberoid°Mop Granule No (Cap Sheet in {Cap Sheet in No No No No No 2-ply system} 2-plysystem) See 5.6.1 Yes Yes Ruberold® Mop Granule FR No (cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 NEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization #32455 7t" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23: 12/14/7021 Page 4 of 8 NNEMO I etc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE IA: ALLOWABLE UNDERLAYMENT / TILE^ADHESIVE COMBINATIONS2 Underlayment Adhesive Florida Product Approval Ruberoid® Mop Granule; RuberoidO Mop Granule FR Dupont "Tile BondTM' Roof Tile Adhesive" FL22525 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates GAF Extended Dry -In Membrane self -adhering None plywood Liberty— SBS Self -Adhering Base/Ply Sheet self -adhering {Optional) ASTM D41 plywood 5tormGuard® Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier Liberty- SBS Self -Adhering Base/Ply Sheet self -adhering None ASTM D226 felt, Type II 5tormGuard® Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier Liberty- SBS Self -Adhering Base/Ply Sheet self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) StormGuard® Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier Ruberoid® Mop Granule hat asphalt A5Tfv1 D41 structural concrete Ruberoid® Mop Granule FR Ruberoid® Mop Granule hot asphalt None GAFGLAS® #80 Ultima- Base Sheet or Ruberoid® 20 Smooth Ruberoid" Mop Granule FR 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. z Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approvol for Overturning Moment Resistance Performance. MEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization #32455 rH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23: 12/14/2021 Page 5 of 8 ONEMOletc. #1 Maximum Design Pressure = -442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLA5 480 Uitima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid® Mop Granule or Ruberoid° Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #2 Maximum Design Pressure = -45 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® 480 Ultima'" Base Sheet or Ruberoid° 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 43 Maximum Design Pressure = -75 ps.f. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure - -97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 Ultima'"' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoi' Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate ofAuthorization #32455 7T"EDITION (20201 FBC NON-HVHZ EVALUATION FL10626•R23 GAF Roof Underlayments Revision 23: 12/14/2021 Page 6 of 9 NNEMO I etc. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Exposure Installation Type (days) Deck -Armor'' Premium Breathable Roof Deck Protection, FeltBusterO Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, Storm5afe'" Anchor Sheet, Tiger Paw'" Premium Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck Mechanically attached 30 Protection, Liberty'" SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier and WeatherWatch® Mineral -Surfaced Leak Barrier GAF Extended Dry -In Membrane Mechanically attached 180 Adhesive -set tile roof system 180 Ruberoid® Mop Granule and Ruberoid® Mop Granule FR Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 5-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Map Granule FIR Flat Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Max. 10-tile stack 4:12 6. INSTALLATION; 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3 Deck-ArmorT"" Premium Breathable Roof Deck Protection or Tiger Paw'"' Premium Roof Deck Protection: 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.4 FeltBuster�l Synthetic Roofing Felt: 6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5 StormSafel- Anchor Sheet: 63A StormSafe'" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23: 12/14/2021 Page 7 of 8 ONEMOJetc. 6.3.3 One the same day, install LibertyT"" SBS Self -Adhering Base/Ply; StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier over the StormSafe'" Anchor Sheet. 6.6 Shingle -Mate" Roof Deck Protection: 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.7 VersaShield® Fire -Resistant Roof Deck Protection: 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.8 GAF Extended Dry -In Membrane, Liberty'' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier or WeatherWatch'D Mineral -Surfaced Leak Barrier: 6.8.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. 6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within min. 4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry -In Membrane, LibertyTM SBS Self -Adhering Base/Ply Sheet, StormGuardO Film -Surfaced Leak Barrier or WeatherWatchl Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.9 Ruberoid® Mop Granule; Ruberoid O Map Granule FR: 6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3 Refer to Table 4 for tile staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL, LLC. — QUA9625; (613) 371-2765; Jacob.Stewart@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01506.04.08-R23 Certificate ofAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23: 12114/7021 Page 8 of 8