Loading...
HomeMy WebLinkAboutFormboard Survey 8-31-16N 7�LOCATION MAP 0 a 9 10 NOT TO SCALE a Na SB.R81 25, MWV 37 SWK RANM 40 E49 n ,z i3 "4443 Dx JC`S' i 27 38 37 4 28 29 35' � 30 POND 34 31 S3 32 26 9. / 21 CAUL_FIELD & WHEELER, INC. CIVIL ENGINEERING - LAND PLANNING LANDSCAPE ARCHITECTURE - SURVEYING ;. 7900 GLADES ROAD - SUITE 100 BOCA RATON, FLORIDA 33434 PHONE (560-392-1991 / FAX (561)-750-1452 um. 1. REPRODUCTIONS OF THIS SKETCH ARE NOT VAUD UNLESS SEALED WITH AN EMBOSSED SURVEYOR'S SEAL. 2. SURVEY MAP OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED PROFESSIONAL LAND SURVEYOR. 3. LANDS SHOWN HEREON ARE NOT ABSTRACTED FOR RIGHTS —OF —WAY, EASEMENTS, OWNERSHIP, OR OTHER INSTRUMENTS OF RECORD. 4. ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM (N.A.V.D.) OF 1988. 5. BEARINGS SHOWN HEREON ARE RELATIVE TO THE SOUTH LINE LOT 14, HAVING A BEARING OF N43'59'35"E. 6. THE DESCRIPTION SHOWN HEREON IS IN ACCORD WITH THE INSTRUMENT OF RECORD. 7. UNDERGROUND FOUNDATIONS WERE NOT LOCATED. 8, ADDITIONS OR DELETIONS TO SURVEY MAPS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 9. FLOOD ZONE: AE EL-6 AND ); FIRM MAP NO. 12011C; COMMUNITY NO. 120285; PANEL NO 0406 J; DATE: FEBRUARY 16, 2012 10. BENCH MARK: TIDAL BENCH MARK, ST LUCIE COUNTY: "872 2334 TIDAL 4", ELEVATION= 2.60(NAVD 88). 11. PROPERTY ADRESS: 3050 NW RADCLIFFE WAY RIVERBEND LOT 14 BOUNDARY SURVEY ST LUCIE COUNTY, FLORIDA Q SET 5/8' IR/CAP LB 3591 TYPICAL LEGEND D.E. - DRAINAGE EASEMENT I.P. - IRON PIPE L.A.E. - LIMITED ACCESS EASEMENT CONIC. - CONCRETE G.V. - GATE VALVE L.M.E. - LAKE MAINTENANCE EASEMENT COV - COVERED P.P. - POWER POLE L.M.A.E. - LAKE MAINTENANCE ELEV. - ELEVATION BLDG. BUILDING ACCESS EASEMENT ESMT. - EASEMENT N.R. - NOT RADIAL 00.00 DENOTES PROPOSED ELEVATION U.E. - UTILITY EASEMENT NO I.D.- NO IDENTIFICATION DIRECTION OF FLOW W.M. - WATER METER Y.D. - YARD DRAIN 0.00 DENOTES EXISTING ELEVATION FLR' - FLOOR FlN. - FINISHED A/C -AIR CONDITIONER P.I.--PORJT OF INTERSECTION PROP. PROPOSED O.B. - CATCH BASIN G.V. — GATE VALVE GRAPHIC SCALL P.C. —POINT OF CURVATURE TYP. P.C.0 — POINT OF COMPOUND CURVATURE R — RADIDI US tF.H. — FIRE HYDRANT 20 0 10 20 P.R.C. — POINT OF REVERSE CURVE P.T.— POINT OF TRANSITION®— R.P. — RADIUS POINT STORM MANHOLE O.E. - OVERHANG EASEMENT L.P. — LIGHT POLE © — SANITARY MANHOLE B.E. — BUFFER EASEMENT C.O. — CLEANOUT M.H. — MANHOLE ¢ — CENTERLINE NORTH ORB — OFFICIAL RECORDS BOOK O .PAGE SAN. — SANITARY WATER SERVICE IN FEET L. — ARC LENGTH ALUM. — ALUMINUM Q — DELTA (CENTRAL ANGLE) P.C.P.—PERMANENT CONTROL POINT ■ P.R.M.—PERMANENT REFRENCE MONUMENT w" .5 PROVm�- 1,400 LOT 14, "RIVERBEND", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 67. PAGES 36 THROUGH 39 OF THE PUBLIC RECORDS OF ST LUCIE COUNTY, FLORIDA. SAID LANDS SITUATE IN SL LUCIE COUNTY, FLORIDA. CONTAINING 31,771 SQUARE FEET / 0.7294 ACRES, MORE OR LESS. SUBJECT TO EASEMENTS, RESTRICTIONS, RESERVATIONS, COVENANTS, AND RIGHTS —OF —WAY OF RECORD. FORMROARD RIIRVFY R/99/19 T Ll ADDED PROPOSED CIRCULAR DRIVE 8 19 16 QF ADDED PROPOSED SUMMER KITCHEN 7 19 16 JS ADDED PROPOSED POOL SPA,FIRE PIT AND DECK 7 11 16 CE ADDED PROPOSED SEPTIC SYSTEM AND FIN.FLR. 6 14 16 CE REVISE FEMA INFO 5 26 16 TK PERMIT SKETCH 5/2/16 JS REVISIONS DATE BY �� VA T ao 1 AVO 3 1 201E A.,ug%IR Cl*ui nk4 FL, I HEREBY CERTIFY THAT THE ATTACHED BOUNDARY SURVEY OF THE HEREON DESCRIBED PROPERTY IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF AS SURVEYED UNDER MY DIRECTION ON MAY 2, 2016. 1 FURTHER q9LILY THAT THIS BOUNDARY SURVEY MEETS THE STANDARDS OF PRAC FORTH IN 17 ADOPTED BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORFA A , PURWMT TO FLORIDA STATUTES 472.027. DAVID P. L REG. LAND STATE OF #350 Sc�9� DATE 1"=20' FLD.BK. - N/ACHECKED BY DPL PAGE N/A4-� FILE NAME 658114 1�06-- 0 q 32,