HomeMy WebLinkAboutSewage Construction Inspection & Final ApprovalSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL. SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
f ' � -..o
PLICATION' t AP:124326'1.
PERMIT #., 56-SFA 687678
DOCUMENT #:F11124661
DATE PAID-::06/08/2016
FEE PAID:400.00
RECEIPT #:56-P1D=2968279
APPLICANT: Standard Pacific:of Florida FP, Inc
AGENT: The Milcor'Group, Inc.
PROPERTY ADDRESS: 3050 NW Radcliffe Way Palm City, FL 34990
LOT: 14 BLOCK: r _A y r V,5 2,
SUBDIVISION: Riverbend ID# 4425.703 0019 000 1 G/Y U {v�
CHECKED. [X] ITEMS .ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND. MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ]
[01]
TANK SIZE (1] 1050,00 [21 483.00
L ]
[271
SURFACE WATER 1OO
FT
[ ]
[021
TANK MATERIAL Concrete
[ ]
[28]
;DITCHES
FT
( ]
[03]
OUTLET 'DEVICE
[' ]
[2-9]
PRIVATE WELLS
FT
[ ]
[04']
MULTI' -CHAMBERED [ Y N ]
[ ]
[30]
.PUBLIC WELLS
FT
[ ]
['05]
OUTLET FILTER Polylok PL-68
�. ]
[311
IRRIGATION WELLS
FT
].
[ 0 61
LEGEND 1, 28-015-08SC3 2. 70A 43=54SC4
[ ]
[ 32 ]
POTABLE WATER 75
FT
]
[07]
WATERTIGHT
[ ]
[33.]
BUILDING FOUNDATIONS 6
FT
[ ].
[08]
LEVEL
[ ]
[341
.PROPERTY LINES 5
FT
]
[09]
DEPTH TO LID
[ ]
[35;]
OTHER
FT
DRAINF.IELD INSTALLATION
FILLED / MOUND SYSTEM
[ ]
[10]
AREA [1] 849 [21 SQFT
[ ]
[361
DRAINFIELD COVER
[ ]
[111
DISTRIBUTION BOX HEADER X
( ]
[371
SHOULDERS
[ ]
1121
NUMBER OF DRAINLINES 1, 5.00 2.
[ ]
[391
SLOPES,
[ ]
[13]
DRAINLINE .SEPARATION
[ ]
[391
STABILIZATION 07/18/2017
[ ]
[141
DRAINLINE, SLOPE
[ ]
[1'5]
DEPTH OF COVER
ADDITIONAL;INFORMAT-ION
[ ]
[16]
ELEVATION [ ASOVE / BELOW ]BM 16s00
[ ]
[40.1
UNOBSTRUCTED AREA
{ ]
[17]
SYSTEM LOCATION
[ ],
(41,1
'STORMWATER RUNOFF
[ ]
[181
DOSING PUMPS' 1.00
[ ]
(421
ALARMS
[ ]
[19.]
AGGREGATE SIZE
[ ]
[43]
MAINTENANCE AGREEMENT
[ ']
[:20]
AGGREGATE EXCESSIVE FINES
( ]
144.1
BUILDING AREA
[ ]
[21]
AGGREGATE DEPTH
( ]
[4`5']
LOCATION CONFORMS.WITH SITE PLAN
[ ]
[46]
FINAL SITE GRADING:
FILL / EXCAVATION MATERIAL,
[ ] [47]
CONTRACTOR Brian. Davis (Brian Davis Sept
[ ] {22]
FILL. AMOUNT
[ ] [48]
OTHER INFILTRATOR Quick4Plus E036 LP
[ ] [23]
FILL TEXTURE
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED
[ ]. [49]
TANK PUMPED
[ ] [26]
REPLACEMENT MATERIAL,
[ ]' [5,0']
TANK CRUSHED & FILLED,
Comments:
Comments are on page 2.
CONSTRUCTION [ APPROVED DISAPPROVED
1: Environmental Spe
_ . St, Lucie' CHD
(ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED 1: � — ----St. Lucie 'CH
Environmental Specialist II Brian gram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-.6.0034 FAC
EH Database v 1.0.1 A P1243261 EI01607670
DATE,' 05/03/2017
DATE: 07/18/2017
Page 2 of 3
Violation Number
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION. INSPECTION AND FINAL APPROVAL
Comment,
JPLICATIDN # AP1`2432611
PERMIT #-:56=SF-16:87678
DOCUMENT. #:F1112466,1
DATE .PAID.:06ffl.8f2016
FEE .PAID.,400.00
RECEIPT #,,55-R D-29U..279
DUM-...,
The system is sized for 5 bedrooms with a. maximum occupancy of 1.0 persons (2.per bedroom), fora total. estimated flow of 640
jpd. 1050gal+483gal STs. in series. 540 gal (70-143-54SC4) DT. liberty 1/3h,p pump. 5kl5 chamber long, trench DF.
Jo violations, system .ok.to cover. Contractor notified onsite. Needs final inspection for mound system and alarm check.
'final system approved. Contractor, builder, and building department emailed' final approval.
DH 40116, 08109. (Obsoletes all, previous editions which may not be, used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1243261 EID1607670