HomeMy WebLinkAboutSoil Nuclear Gauge•
a
Soil Nuclear Gauge
Client:
Project:
Report Date: 8/31/2016
Standard Pacific Homes, South Florida
13-0183.00
�y;RNpjo�p�
Test Method: ASTM D 6938
825 Coral Ridge Drive
Riverbend
Port St. Lucie
Coral Springs, FL 33071-4180
St. Lucie County, Florida
FBPE CA # 4930
521 NW Enterprise Drive
Port St Lucie, FL 34986
Phone: 772-924-3575 1 Fax: 772-924-3580
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
97
8/15/16
P-1
N/A
10.2
116.0
9.5
114.4
12
99
951105
Pass
98
8/15/16
P-1
N/A
10.2
116.0
9.7
114.2
12
98
95 / 105
Pass
99
8/15/16
P-1
N/A
1 10.2
1 116.0
9.9
113.7
12
98
95 / 105 1
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
97
Below Slab Grade: Lot No. 14, Foundation Pad. Northwest section
0-1
Troxler T3430 36442
Boyle, John
98
Below Slab Grade: Lot No. 14, Foundation Pad. Center section
0-1
Troxler T3430 36442
Boyle, John
99
Below Slab Grade: Lot No. 14, Foundation Pad. Southeast section
0-1
Troxler T3430 36442
Boyle, John
Remarks
I Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
/,z
AUG 3 $ P.
pins
St. >Lua:�;
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
f
Page 1 of 1
E-MAILED FEB 912017
114-S , ARD
ULOION, CEkTIFICA ION C
Perrhit#: 116 01�5
Insulation Contractor Name:. TCI CONTRACTING LLI.b DBA IBP OF WEST PALM
Jobsite-Contractor; CALATLANTIC
Jobsite Address: '.5050 J\j W,
Section: Block:
Manufactures'Name, DEMILEC
Insulation Type.-. SEALECTION 500 OPEN CELL FOAM
R4alue of Insulation: R-20
Thickness of Insulation Installed: 6.5
Wcation of Insulation Installed: TOP CHORD OF TRUSSES
Data of Instal'Won C-;-, 1. 1
Manufactures Ndmv. FIFOIL
OWENS CORNING
Insulation Type,, 13ATT
BAT I`
R-Value- of Insulation: 4.1
R-19
Thickness of Insulation Installed, 3/4"
6.25
Location of Insulation Install d; BLOCK EXT WALL,
EXT WALL FRAME
Date of Installation*
Please. Chpqk One:
0' Attic insulation installed vuith vontil6t— per IoR8016., R006.2 and n..
R-8063 Florida kesidential Code'2014
a Conditioned attic assembly insulation has been Installed per R-806.4,
Florida Residential Code 2014
. ED IN MUST BV0 . N TIE
-A PROMINENT LOCATIO AND RETURNED TO
N a EFORE you FINAL INSPECTION.
ignature
r
11,1ZV A L EC T 10 N° 500,
CompanyName
lap OF ttiEsT .-ALM
Phone Number
561-249-6241
Applicator Name
6 aG o / - .,
Installation Date
�` %117
Jobsite Address
Li 'mac .
A -Side Lot Vs
Permit Number
BrSide Lot.#'s
www.Demilec.com DEMILE
C