Loading...
HomeMy WebLinkAboutProduct Approval - Roofing UnderlaymentsRECEIVED R 2 9 2022 �t.. ueFll�a,{�f#W+IFqaidnty BCIS Home � Wg In User Registration � .Mot Topics I Su�FittltlSl 9arge I Scats & Facts Ribilcations Contact Us" BCIS Site Map Links Search l a �i f Product Approval P 5 � - USER: Public User q.-D Produ Apgrnva; Mend > Prgd= ar Appligalinp_Sc+,etr > A pi{^a tr,p L(st > Application Detail FL * FL10626-R22 Application type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800) 766-3411. mstleh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestions6AF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i. Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/17/2021 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL106?6 R22 COI 7Q21 Al rqI NIEMINEN,p!ff Referenced Standard and Year (of Standard) Standprd ASTM D1970 ASTM D4533 (tear) ASTM D4798 , REVIEWED FOR ASTM D4869 (water transmission) CODE C®MPL1AN - ,'XSTM D6164 (tensile) STo LUCIE COUNTYASTM D6757 B®CC /��,a�- ) ^ FM 4474 FRSA/TRI, 6lh Edition FILE COPY 2015 2015 2011 2016 2011 2011 2016 2011 2018 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL # 10626.1 Method 1 Option D 06/09/2021 06/11/2021 06/17/2021 08/10/2021 Number or Name I Description GAF Roof Underlayments for Roofing Underlayments for use in sloped roof systems use in FBC non-HVHZ jurisdictions Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-442.5 Other: 1.) The design pressure noted in this application relates to one particular underlayment system. Refer to ER Section 5.8.3 for details. 2.) Refer to ER Section 5 for other Limits of Use. Installation Instructions FL10626 R22 II 2L ER GAF UNDERLAYMr;Nia ULPSff Verified By: Robert Niemien 59166 Created by Independent Third Party: Yes Evaluation Reports fl_10626 R22 AF-20RI 06 09 FINAL ER GAF UNDERLAYMENTS FL10626- R2 .pff Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Talla as ea FL 32329 Phone; 850 497-1024 The State of Florida Is an AA/EEO employer. Cogyr1g(i2007-2013 State of Florida, :: Privacy Statement ;: accessibility Statement :: Refynd Stateme Under Florida law, email addresses are public records. If you do not want your a -mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.407.1395, *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval' Accepts: MOMWERM �i�i.ta �twir c,(tz'' NEMO etc. Certfcate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT 1Campus Drive Parsippany, NJ 07054 (800) 766-3411 Evaluation'Report 01506.04.08-1122 FL10626-1122 Date of Issuance: 04/25/2008 Revision 22: 06/09/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then. it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: . yy}pmrrn., a Robert J.M. Nieminen, P.E..; ,�� R,:^ r•, The facsimile seal appearing was authorized by Robert ; Florida Registration No. 59166, Florida DCA ANE1983 ;�a`' :.cam _ � r.,ssror��t�;,.," Nieminen, p,E, on 06/09/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither MEMO ETC, LLC nor: Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC (NNEMOJetc. ROOFING COMPONENT EVALUATION: e Product Category: g Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the Th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. P,•, Section, `` Pro a"rt' Staridard' Year � 1504.3.1 Wind resistance FM 4474 2011 1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.1.1.1(2&3, Exception), Tear Strength ASTM D4533 2015 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1 / R905.1.1 Material standard ASTM D6757 2016 1507.3.3, R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 : Examiriatio Reference' Date. Entity= " ;" ERD (TST 6049) ASTM D1623 & FRSA/TRI (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 (GA) G40630.01.14-2B 01/07/2014 ERD (TST 6049) ASTM D6164 (GA) G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-3 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-4 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-1 03/08/2017 ERD (TST6049) ASTM D1970 (IN) GAF-SC16440.12.17 12/31/2017 Intertek (TST 1558) ASTM D4869 (Dadra, India) F8549.02-106-18 11/08/2016 NEMO (TST 6049) Physical Properties (ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019 NEMO (TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020 MEMO (TST 6049) ASTM D4798, TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021 NEMO (TST6049) ASTM D4798 41-FTS-2I-SSUDL-02.A 06/09/2021 PRI (TST 5878) ASTM D1970 (IN) GAF-324-02-01 11/30/2011 PRI (TST 5878) ASTM D226 (OK) GAF-339-02-01 03/13/2012 PRI (TST 5878) ASTM D4798 (NC) GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) ASTM D4533 (various) GAF-818-02-01 12/05/2017 PRI (TST 5878) ASTM D1970 (AL) MSA-047-02-01 04/11/2018 PRI (TST 5878) ASTM D4533. (LA) GAF-826-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-847-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-914-02-01 04/10/2019 PRI (TST 5878) ASTM D4533, D5035 (VA) 376TOO12 07/15/2019 PRI (TST 5878) ASTM D4533 (Umerkui Kilvani, India) 376TOO18 07/31/2019 PRI (TST 5878) ASTM D4533 (Parzai, India) 376TOO18 07/31/2019 NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Autharization#32455 7-EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2022 Page 2 of 9 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 Entit �3{ : Examination PRI (TST 5878) ASTM D1970 (AR) PRI (TST 5878) ASTM D226 (S-CA) PRI (TST 5878) ASTM D4533 (Gujarat, India) PRI (TST 5878) ASTM D5035 (various) PRI (TST 5878) ASTM D4533, D5035 (Rajasthan PRI (TST 5878) ASTM D4533, D5035 (Gujarat, I UL (TST 1740) ASTM D6757 (TX) PRI (TST 5878) ASTM D5035 (Gujarat, India) PRI (TST 5878) ASTM D4533, D5035 (Rajasthan, UL (TST 1740) ASTM D6757 (NC) NEMO ETC Traceability NEW Traceability UL, LLC (QUA 9625) Quality Control UL, LLC (QUA 9625) Quality Control U L, LLC (QUA 9625) Quality Control NEmo I etc. ,India) ekrence 376T0032 10/22/2019 376T0054 02/18/2020 376T0058 02/18/2020 376TO103 09/11/2020 376T0111 12/22/2020 .Product - Wterial5tadard Plants) GAF Extended Dry -In Membrane ASTM D1970 Langley, BC Canada Liberty"' SBS Self -Adhering Base/Ply Mt. Vernon, IN Sheet .__ ASTM D1970 .......... Savannah, GA StormGuard" Film -Surfaced Leak Barrier ASTM D1970 Mt. Vernon, IN Savannah, GA Arkadelphia, AR WeatherWatch" Mineral -Surfaced Leak ASTM D1970 Mt. Vernon, IN Barrier Savannah, GA Tuscaloosa, AL Deck-Armor"m Premium Breathable Roof 1507.1.1.1(2&3, Exception) / Deck Protection R905.1.1.1(2&3, Exception) Dadra, India Dadra, India FeltBuster' Synthetic Roofing Felt 1507.1.1.1(2&3, Exception), Gujarat, India (formerly FelteustermHigh-Traction synthetic 1507.1.1.1(5) / 11905.1,1.1(20, (CPP) Rajasthan, India Roofing Felt) Exception), R905.1.1.1(5) (MIP) Rajasthan, India Richmond, VA _ Spartanburg, SC _ Shingle -Mate" Roof Deck Protection ASTM D226, Type If (Table 1) Pryor, OK Shafter, CA StormSafe'" Anchor Sheet 1507.1.1.1(2&3, Exception) / North Bay, ON R905.1.1.1(2&3, Exception) Tiger Paw'"' Premium Roof Deck 1507.1.1.1(2&3,Exception)/ Dadra, India Gujarat, India Protection (formerly77gerPow- Roof Deck Protection) R905.1.1.1(20, Exception) Parzai, India Umerkui Kilvani, India VersaShield" Fire -Resistant Roof Deck ... Protection ASTM 06757 Conover, NC Ruberoid" Mop Granule ASTM D6164 Savannah, GA FRSA/TRI 09-18 Ruberoldg Mop Granule FR ASTM D.6164 Savannah, GA FRSA/TRI 09-18 NEIVIO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate al Authorization #32455 7-1 EDITION (2020) FBC NON-NVW2 EVALUATION F1.10626-1122 GAF Roof Underlayments Revision 22; 06/09/2021 Page 3 of 9 �`�7 ONEMO I etc. 5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within 'FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABEE 1� RoQF CdVER OpT1oNs WSW ton" , . .. 1507.2 1507 3 ,.., 15074 and 1507.5 1507 7 . 1507 8 add 1507.9 , Ciay and Concrete Tile Metal Slate or W d oo . Underlayment:. Asphalt Shingles' Slate -Typo ` Mechanical Adleswe- Panels Shingles Shingles Shakes Attach, Set:;, •. Shingles Yes Yes GAF Extended Dry -In Membrane Yes No No Yes Yes Yes Uointstrips, 1507.1.1.3 / Uointstrips, 1507.1.1.3 / R905.1.1,3) R905.1.1.3) Yes Yes Liberty'" SBS Self -Adhering Yes No No No No No (joint strips, Uointstrips, Base/Ply Sheet 1507.1.1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes StormGuard° Film -Surfaced Leak Yes No No Yes Yes Yes Writ strips, (loInt strips, Barrier 1507.1.1.3/ 1507.1.1.3/ . R905.1,1.31 R905.1.1.3) Yes Yes WeatherWatch" Mineral -Surfaced Yes No No No No No (lolntstrips, Qoint strips, Leak Barrier 1507.1.1.31 1507.1.1.3/ - R905.1.13) R905.1.1.3) Deck -Armor'" Premium Breathable Yes No No Yes Yes Yes No No Roof Deck Protection FeltBuster'" Synthetic Roofing Felt Yes No No No No No No No Shingle -Mate® Roof Deck Yes No No No No No No No Protection ....... —. Tiger Paw'" Premium Roof Deck Yes No No Yes Yes Yes No No Protection — VersaShield" Fire -Resistant Roof Yes No No No No No No No Deck Protection Yes Ruberoid" Mop Granule No Yes (Cap Sheet in (Cap sheet in 2-ply system) No No No No No 2-ply system) See 5.6.1 Yes Ruberoid® Mop Granule FR No Yes (Cap Sheet in (Cap Sheet in 2-ply system) No No No No No 2-ply system) See 5.6.1 _ NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #32455 7-EDITION'(2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 4 of 9 (NNEMO etc, 5.6.1 Adhesive -set is limited to use of following underlayment J tile -adhesive combinations. TABLE .4I Q1AlA[iLE UNDEgIAyMfE�tT }�{TILES ADHESIVE CO[�IIBINATIONS %. ;F Underlayment Adhesive Florida Product Approval --, Ruberoid°+ Mop Granule; Ruberoid" Mop Granule FR Dupont `rile Band'" Roof Tile Adhesive" FL22525 5.7 Allowable Substrates: TABLE 2, SUBSTRATE OPTIONS fOR;ADHEREI)'IINDERLi4YMEf115 4 . r. ::Underlayrrierit"pphcation Primer Substrates GAF Extended Dry -In Membrane self -adhering None plywood Liberty— SBS Self -Adhering Base/Ply Sheet self -,adhering (Optional) ASTM D41 plywood StormGuard® Film -Surfaced Leak Barrier Weather Watch" Mineral -Surfaced Leak Barrier Liberty' SBS Self -Adhering Base/Ply Sheet self -adhering None ASTM D226 felt, Type II StormGuard• Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced leak Barrier LibertyTM' SBS Self -Adhering Base/Ply Sheet self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) StormGuard® Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier RuberoidW Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid® Mop Granule FR Ruberoid® Mop Granule hot asphalt None GAFGLAS• #90 Ultima"m Base Sheet or Ruberoid® 20 Smooth Ruberoid® Mop Granule FR 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than F8C 1507.1.2 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #3245S 7-EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-1122 GAF Roof Underiayments Revision 22: 06/09/2021 Page 5 of 9 ONEM® I etc. #1 Maximum Design Pressure = -442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoide' Mop Granule or RuberoidO Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 lbs/square. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #2 Maximum Design Pressure = -45 Dsf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows In the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Desixn Pressure = -75 Psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or RuberoidO Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure = -97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min.1.25-inch long ring shank nails through 32 ga., 1-5/8-Inch diameter tin caps spaced 4-inch D.C. at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the sheet. Cap Sheet: RuberoidO Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.D4.08-R22 Certificate of Authorkation #32455 7Tu EDITION (2020) FBC NON-HVH2 EVALUATION F1.10626-1122 GAF Roof Underlayments Revision 22: 06/09/2021 Page 6 of 9 O.NEMOJetc. 5.9 Exposure Limitations: .. �T T � ��. � Prepared Roof Cover Maximum ;. Underhyment� Exposure .• Installation Type • ' (days) Deck -Armor"" Premium Breathable Roof Deck Protection, FeltBuster'"" Synthetic Roofing Felt, Shingle -Mate* Roof Deck Protectidn, StormSafe"" Anchor Sheet, Tiger Paw"a Premium Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck Mechanically attached 30 Protection, Liberty"' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier and WeatherWatch° Mineral -Surfaced Leak Barrier GAF Extended Dry -In Membrane Mechanically attached 180 Adhesive set the roof system 180 Ruberoid° Mop Granule and Ruberoid® Mop Granule FR Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. LE S,L,IPPAGE lINlITATIOMS;FOR DIRE4T DC1(,�ILE INSTALLATIONS underlayment. _ , . Tile"Profile°' Staging Method, .. Maximum Staging Slope Ruberoid® Mop Granule Flat Max.10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max.10-tile stack 5:12 Ruberoid® Mop Granule FR Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 4:12 6.1 GAF Roof Underiayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below, 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1,1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions, FBC requirements take precedence over the manufacturer's installation instructions. 6 4`- " FeltBuster'"! 5yntiietic,goeffIng Felts 6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3; Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or 11905A.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NENIO ETC, LLC Evaluation Report 01506.04.08-1122 Certtftate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 7 of 9 (NNEMOjetc. 6.5.1 StormSafeT°" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.3 One the same day, install Liberty"" SBS Self -Adhering Base/Ply; StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier over the StormSafeTm Anchor Sheet. 6 t Shingle=Metes Roof Deck'Pratea#on• 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type 11) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's Installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. B.8 � GAF Extefdetl Dry In Membrarie,'liberty'" SBS Self Adhering,Base/Ply Sheet, 5tormGuarde Film Surfaced Leakn` ,, „ ,Barrier or;WeatherWatc���Mineral Surfaced Leek Rarw•let. ; , 6.8.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. 6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within min. 4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or 11905.1.1. 6.8.4 GAF Extended Dry -In Membrane, Liberty"" SB5 Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier or WeatherWatch" Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6:9 Rubero)d® Mop Granule;-Ruberod® Mop Granule FR 6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "rwo Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3 Refer to Table 4 for tile staging limitations. NEMO ETC, LLC Evaluation Report 01506.04.0E-1122 Certiftate ofAuthoriaation #32455 7T" EDITION (2020) FBC NON-HVH2 EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22; 06/09/2021 Page 8 of 9 Contact the named OA entity for manufacturing facilities covered by F.A.C. Rule 61G204 QA requirements. to Section 4 herein for products and production locations having met codified material standards. UL, LLC. — QUA9625; (414) 248-6409; karen.buchmahn@ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC Certijlcate ojAuthorization H32455 7-EDITION (2020) FHC NON-HVHZ EVALUATION GAF Roof Underiayments Evaluation Report 01506.04.08-R22 I U.0626-R22 Revision 22: 06/09/2021 Page 9 of 9