Loading...
HomeMy WebLinkAboutEngineeringFLORIDA Florida Engineering LLC 0 4151 Tamiami Trail, Suite 101, Port Charlotte, FL 33952-924 ENGINEERING WWw.flengirieeringllc.com I Phone: (941) 391-5980 License Number #30782, #60102 arch; -1st, 2022: Leman Residence 10680'5Ocean 41102 Jensen Beach,µFL 34957; `Job No: " ° 2205972° Design Criteria, applicable codes and standards: 1. 2020 FBC (7th Edition), Ch. 16 Structural Design 2. ASCE 7=16: Minimum Design Loads for Buildings and other Structures. Ch. 30 Wind Loads - Components & Cladding Z%03 - 05- 7c( REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY Boce General Inputs Ultimate Wind Speed (mph) 175 Exposure Category D Mean Roof height (ft) 130. Enclosure Type Enclosed• .-- Internal Pressure Coefficient (±) 0.18 Roof Pitch (in 12) 0'' Minimum bldg dimension (ft) 30- Opening no. Width Height Effective wind area (sq. in) Zone External Pressure Coefficient Internal Pressure Coefficient Design Pressures Positive I Negative (in) (in) Positive Negative (psf) 1 36.75 63.00 20.00 4 0.90 -0.90 0.18 63.22 -64.77 2 1 36.75 63.00 20.00 4 1 0.90 -0.90 0.18 63.22 -64.77 3 52.75 63.00 23.08 4 0.90 -0.90 0.18 63.11 -64.69 4 105.75 95.50 70.13 4 0.87 -0.88 0.18 61.40 =63.51 5 141.75 95.50 94.01 4 0.85 -0.87 0.18 60.53 -62.92 GuA.1, No. 60102 ``0 0 STATE OF �A" � ���ORID�`.•"aN°��N FILE COPY E. GUNDERSON, P.E. #60102