HomeMy WebLinkAboutNOA Aluminum Single Hung WindowM IAM FDADE MIAMI-DADE COUNTY • PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND, ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 'F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidaae.Qov/bnildina CGI Windows and Doors, Inc. 3780 W 104" Street � � Hialeah, FL 33018 REVIEWED SCOPE: - CODE (OC)MPLIAniCE This NOA is being issued under the applicable rules 'er g eo f i e of construction materials. The documentation submitted has been revie a an ac �M 1-Dade County RER - Product Control Section to be used in Miami Dade County and othe e wed by the Authority Having Jurisdiction (AHJ). This NOA.shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade.County) reserve the right -to have.this product or material tested for quality assurance purposes. If this product ofmaterial fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 110" Aluminum mge : ,ung W' o W L.M.I. APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product' Control Approved"; unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or'process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be- displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-1018.08 and consists of this. page 1 and eviden s E-3, E-4 and E-5, as well as approval document mentioned above: FILE The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0722.09 Mti oc,oe coury r�r Expiration Date: September 22, 2025 Approval Date: September 10, 2020 T9/1/20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No.10-0510.11) 2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets l through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,. P.E. (Submitted under NOA No.17-1018.08) B. TESTS 1: Test reports or!: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal(m and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed, and. sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact. Test per FBC, TAS 201-94. 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super .SpacerC insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under.NOA.No.15-0512.09) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) Manuel Perez, P.E.- Product Control Expwlft.r 1 NOA No. 20 0722.09 Expiration Date: September 2 Approval Date: September 10, '020 E-1 1. EVIDENCE SUBMITTED UNDER PREVIOUS' NOA's (CONTINUED) B. TESTS (CONTINUED) 4: Test reports_ on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading"per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile,Impact Test.perFBC',,TAS 201794 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Tesi,.per FBC 2411.3.2.1; TAS 202-94 along with marked -up; drawings and installation diagram of a series "Sentinel" aluminum single hung window, prepared by Hurricane Test Laboratory,. LLC, Test Report No. HTL-0080-010140. dated 02'/03/10, signed and, sealed, by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by;Javad Ahmad, P.E. (Submitted under NOA No.]7:1018.08) 2. Glazing complies with ASTM E1300-00 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/,15, expiring on 07/04/18.. . 2. Notice of Acceptance No, 16-1417.01 issued,to Kuraray America, -Inc: for their "Trosifol® Ultraclear,.Clear, and Color PVB Glass.Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. .17-0712.03 issued to Eastman Chemical Company (MA) .for their "Saflex CP Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17,-expiring on-l2/11/18. 4. Notice of Acceptance No..17-0712.05 issued to'Eastman Chemical Company (MA) for'their "Saflex Clear :and Color Glass Interlayers dated 09/07/17, expiring'on 05%21/21. Manuel e'rez, P:E: Product Control Ex r NOA No: 20 :0722.09 Expiration Date: September:. , 2 Approval Date: September 10; 2020 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) F. STATEMENTS 1.. Statement letter of conformance, complying with FBC 51h Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by-Javad Ahmad, P.E. (Submitted under NOA No.17--1018.08) . 2.. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) 3. Test Proposal for the qualification of Butacite@ PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed.by Jaime Gascon, Supervisor. (Submitted under NOA No. 15-0512.10) G. OTHERS 1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and expiring on 09/22/20. Manuel `Pe Product Control E 1 NOA No. 20 Expiration Date: September Approval Date: September E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No SH110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS L Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsi1791 and Dowsi1983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT, PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, .PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 7tn Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. Product Control Ex NOA No. 21 ;xpiration Date: September Approval Date: September 1 E-4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2., NEW EVIDENCE SUBMITTED (CONTINUED) D. QUALITY ASSURANCE L Miami -Dade Department of Regulatory and Economic Resources (RER) E. MAT_ ERIAL.CERTIFICATIONS -1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray`SentryGlas® XtraTM (SGXT"�' Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America,. Inc. for their "Trosifol® Ultraclear; Clear and Color PVB Glass. Interlayers" dated 05/09/19, expiring on 07/08/24. K - Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No". 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 611 Edition (2017) and the FBC 711 Edition (2020), dated July 16, 2020, issued by Manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued bythe Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility -for all engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed by Anthony Lynn Miller, P.E. 5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors -for their Series "Sentinel 110 Aluminum Single Hung Window - L.M.I., approved on 12/21/17 and expiring on 09/22/20. A Manuel Perez, P Product Control EC0722 ` N& No. 20Expiration Date: September Approval Date: September 10, 2( E-5 NTNS APPUI u r SERIES SENTINEL 110 ALUMINUM SINGLE .HUNG WINDOW LARGE & SMALL MISSILE (LM & SMl DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER MIAMI—DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH. VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS do BUCK FASTENERS BY OTHERS, MUS_T'BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS, TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER .MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ' ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND 'NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS. SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i:e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL FIN FRAME *CENTER ANCHOR REQUIRED WHEN SPACING EXCEEDS 20 9/16" LAMINATED GLASS, INSULATING LAM. GLASS SMALL'MISSILE IMPACT LARGE MISSILE IMPACT' i� PRODUCT REVISED. as complying with the Florida Building Code . REVISED FOR 2020 FBC, ADDED ANCHOR TYPE, 13ACKBEDDING & REFORMATTED-JR- 07/07/20 3 O m m Z r` °I0a U) 0 Z tt K Om ZO U7 W. Z' mZ LLb !n O Al fn KUU� ¢ Q�Z V• °N sMa z rn IL O a�Zm S y z vJ It (A iaa45 0� w o� z o ¢ z z Z {�{�n E c O W UnS"' ri) 'W W aiil •asap saua5 ��•'.• �,1GENS�c '•. lF� y .: No. 58705 ••: I ATE�RF((/- iOT� •'•.FCGRIDT:.•'•�jN &/ONAI- w .�`. A LYNN MILLER, P.E. OMG)Z cmiuEO O N I —> -C ( A to m D n to I^' o m�mnZ o N HEIGHT yn y N�-i • UP O n0� C F go umi ZZ G1 D l7 s 0 Z 8S. C C C z C m x x z m m x o o o G0 o c o N N N Ian' D N .. C. D HEIGHT, C D m En f C Z m, FLANGE DIMS, r p C m MIN. > LLL"��q . 4 D.LO. m p� VENT O DIM 'A' r - BUCK DIM. LENGTH (L) N N W N m N U N + .IW. Aj�� m Da to NN m N m N + m N m ut m N N W N = O +'T + � N 0� O� ± IN N.� 0 N i N � W I' m N � W 1m' I� + W I I•' I'-- N 'N N m i� 0 : Zi Q Jjbj�N00oco00 0' 'N 1 y e eo c o o-c c c, c c o 0 0 0 o c c c o c c o I. 0 o •ii v� oS0000000SooS�0000S:00000SoSS'S��. 0 0.0 0 000 o c o 0 0 o c o 0 0 0 0 0 0 00 0 0 o cc o v u H m u u in tn. o b b c b o b b b b o b-c b b b b o cc o 0 ,fin o b ,in' o b c b ,ia o .. j R' ro m • N m i d p2 G G O O G C O v ! �pp fQ •9 fVT N IVT � H N. fVl, r O c o o �^} mO mo N N !A N m N Ir O N O v Revision: �\\` 0Z}d �, Impact Resistant PREPARED BY A. LYNN MILLER 3 W i Z S .......... .qti�°%, ®Windows&Doors 1 D70 TECHNOLOGY DRIVE 3 - aao0 WM STRONGER" N. VENICE, FL 34275 "' :- 'Z ?� \ ' U ,- COI WINDOWS AND DOORS, INC. (941) 4t30-1600 �y '0 9 fO o C t :^D1��- a�VVV 3780 W 104TH STREET CHIALEAH, FL 33018 REGISTRATION 929296� r ; O2 : -< -(305)5934i590 - om SERIES 110 ALUM. SINGLE HUNG 1MNDOW (LM) 07/02/20 m ym �"��P� o DESIGN LOADS om' JENS.ROSOWSKI N N G. `�. o �7jr I I I I I t \11�' c SH110 "SENTINEL•' i 2 OF 9 oz SH11 D-LM-NOA A N m .D75' Saflex CP With PET Core .075" Saflex CP With PET Core ' By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' .. - .090" Saflex Clear And Color Glass .090" Saflex Clear And Color Glass By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' g4G—S - o: g .090 SentryGIoS0 By 'Kuno America, Inc.' 0"- SentryGlasO 'Kureruy America, Inc.' 1/8- ANNEALED / GLASS .090" Trosifol PV13 By 'Kuraray Ameica, Inc.''Kura .1 HEAT STRE0' Trosiol PVB Ameico, Inc.' 1/8- ANNEALED GLASS HEAT STREN'D GLASS SILICONE �SILICONE - • m m GE 1200 - DOW CORNING 791, GE 1200, DOW CORNING 791, M7899, 983 & 995899, 983 & 995 PE 'A' 5/16- OVERALL LAM. GLASS GLASS TYPE 5/16- OVERALL LAM. GLASS - (L.M.I &,S.M.I.) (L.M.I & S.M.I.) ' .075" Saflex CP With PEr Core .075" Saflex -CP With PET Core By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' ' 1/8- ANNEALED GLASS .090" Saflex Clear And Color Glass 1/8- HEAT STREN'DJE:1' In 09D': Saflex Clear.And Color Glass By 'Eastman Chemical Co.' y 'Eastman Chemical Co.' . .. 1/4' AIR SPACE .090" SentryGlas® 1/4- AIR O90':SentryGlas® 'Kuraroy rBy 'Kuramy America, Inc.' ..y America, Inc.' 1/8- ANNEALED .090" Trosifol PVB 1/8HEAT ST090' Trosifol PVB 'Kuroray OR TEMPERED• GLASS By 'Kuramy Amerca, Inc.' OR TEMPERED- Gy Ameica, Inc.' 1/8" ANNEALED GLASS /8- HEAT STREN'D GLASS SILICONE: SILICONE: W GE 1200 DOW CORNING 791; z . gDOW GE 1200 CORNING 791, M1 899, 983 & 995 899,-983 & 995 XL EDGE SPACER XL EDGE SPACER ST. STEEL BY 'CARDINAL' ST. STEEL BY 'CARDINAL' OR OR O DURASEAL BY 'QUANEx' DURASEAL BY 'QUANEX' OR SPACER BY 'QUANEX' ',ORSUPER SUPER SPACER BY 'QUANIX' PE 'Al j GLASS TYPE 'BI' •• 0.70" OVERALL INSUL LAM. GLASS 0.70' OVERALL INSUL LAM: GLASS - (L.M.I & S.M.I.) (L.M:I &' 'S.M.I.) FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ. OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. PRODUCT REVISED ! - as complying with the Florida Building Code` NOA-No- 20-0722.09 E"I Ilion Date: 9/22/2025 By: , Miam�padei Produet'Co trol ADDED BACKBEDDING TYPES - JR - 07/07/20 9 a" N Y Q onab a o 0 O O z a y Z J f7N ~ O a m 2: I]ZLL. 0 K V LU 0. aTaa Z a� ~ W S > N '000: �W , z 0M0 a z O 2 - IL W O •" z 0 m tCa o t e y O g o ? fn 1aa45 O �°yz ❑tj W Z. -- z Q O I-- E3� W O - rn o OH=m U�M co O 1 In apl •asa0 sauaS ``\`111ll IIII////'Ai �`���Nt •c NSF M��(��' NNo. 58705 0•' ST'E FO '•1��� •'•.FCORIDP•.•'GN� ONAL A LYNN MILLW P.E P.E.ff 58705 TYPICAL ANCHORS SEE ELEV. 1BY SPACING WOOD BUC Via•. .aQ. ,.Y -.EDG` ISf. ,.d ♦d " aa,a. .a. a♦Ai an.♦ ♦ a. EN O SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL METAL STRUCTURE owe EDGE TYPICAL ANCHORS SEE ,ELEV. -DIST.� FOR SPACING m� o 0 3� O d �3 2 3/� 2 3/I I WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%".,THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. L EDGE DISi.—EDGE TYPICAL ANC • DI,ST. lYP ANCHORS ,a SEE ELEV. •^ 1BY I S ELEV. ..,e� FOR SPAC WOOD BUCK V OR SPACING 1 MIAMI-DAOE COUNTY APPROVED EDGE A I� MULLION & MULLION ANCHORS DIS1 y 1 SEE SEPARATE NOA li EDGE \' J, Disr.4 u TYPICAL ANCHORS TYPICAL ANCHORS -SEE ELEV. - SEE ELEV. FOR SPACING FOR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4" DIA. TAPCON BY 'ITW' (Fu-125 KSI, Fy-100 KSI) 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy-155 KSI) 1/4" DIA. ULTRACON+ BY 'DEWALT'(Fu=164 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD THRU'1BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN.. EMBED INTO -BLOCKS (JAMBS). J14 SMS OR SELF DRILLING SCREWS (Fu-74 KSI, Fy-57 KSI) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN. STEEL ; 1/8" THK. MIN: (Fy = '36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO.CONCRETE- AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN., WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN. CONCRETE AT HEAD, SILL OR ,JAMBS f'c = 3000 PSI MIN. ,C-90 HOLLOW/FILLED. BLOCK ATE JAMBS Ym = 2000 .PSI MIN. PRODUCT REVISED as complying with the Florida Building Code _ ADDED ANCHOR TYPE - JR - 07/07/20 o, � m n o 0 H °1OG 0 O � zip Z 0 z LU z ¢>- o W cW=i0d Z qq `1 '°N OMO d~ Z v lu o 0 LL aaoi j x y Z J O m a e y ul C 00 Z G) 1aa45 I j [iJa O Li ¢ Q p' E3 ALL° w Z3Z Jill. c�.�LLI (n LLa0 `�YY Y11111 (717j �_ ` 0LYN1V4 * No. 58705 A gAzbST F CC/ ���111111151\> A LYNN MILLER, P.E. P.E# 58705 c� cmm nr0 Oy A.m Fy• C ' JG O77 O N m I X ------ --- _J 4mm11p D.�g •m��i mPNT wog N �gsm o � m x N x r m x f °0 '� f — 0 O m N O� O i G .O v •. .a . Oc zm °� I� � x N�D J > r o 0 cZi o o y m &•0i m cZi !�{].� y ZZ� pLa OEXTERIOR O Z c» z %1 m !< o _.._.._.._:._.,_.._.._.._.. j C.mN 4] C. 0 �y • xx r�0 PG)0 -- OBI b O mz L -n yO Km 0 m En 1j2• TYP. 1/2" TYP, r� I OImpact Resistant PREPARED BY A. LYNN MILLER ReV`�I° � 3 � � C � w 'C 666 Windows & Doors 1070 TECHNOLOGY DRIVE m e ;� WE'RESMONGEB" N. VENICE, FL 34275 3 z530 > i �� (� '- y CGI WINDOWS AND DOORS, INC. (941) 480-1600 1y 1 0 P �° a C z �-J O 3780 W 104TH STREET 0 �+ a C> . m z o <'• HIALEAH, FL 33018 REGISTRATION #29296 9 m A m 3 _ ; A y .� cn CM)r' (305) 593-6590 c m E, m _ mom-- g z �r SERIES 110ALUM. SINGLE HUNG WINDOW{LM) 0 07102/20 n ao No S N NC in '�C� •,� �h�'\` o.FLANGEDETAILS om JENSROSOWSKI SH110 "SENTINEL"FIF 5 OF 9 oz SH110-LM-NOA a A w m ' a f - D.L. OPG.£o EXTERIOR P mm a �A' m JCK y�'9 ,•'• .. 'b n', xK OPTIONAL ........... .s P•. "' II �� • A* Dula m�nj to m �fmn VENT HEIGHT o 0 ut � 1/4* MAX. BUCK HEIGHT - 1/4' MAX. SHIM SHIM 00 •nm m m m 1 �1/2' �.I 3/4' O y m m to JEF_ POT M r O N N z O m r •-i u a m Z. � m v �m m m om m i O og. z . z -t.M .Z 0 o Z DOm0-4 rn O m p rrn G i '� I' i v n I SHIM DO Colnm a / m mt-n� f 0 I CC'-i Fn O T ')0 v� C 2BY WOOD BUCK OR WOOD STRUCTURE M n En �a TE am m 1/4- MAX. z o SHIM. P m N MIN. ug L�.J.I x m Po I yofE_ 11 q4 � • m z� 1 �2S In"zo II 1� . . Q. � �Eoo 1 m. �R•g j� Z m I ��o ii r In �FLcp I- 00o m ZoEI1 Dz I I t^: JJ Zi I xDwz :or. I 0 0 �{+i_ Ij g2 II. N �m i N.� 1/4' MAX. z ' SHIM m o N Lwd " 7�� OImpact Resistant - Windows &Doors PREPARED BY A. LYNN MILLER 1070 TECHNOLOGY DRIVE 'Revision: 3 p ox, _ w '0 3 �� j• WE'RESTRONDER" N. VENICE, FL 34275 .y: a o O `........... A r) '•,yQ •CGI WINDOWS AND DOORS', INC. (941) 480-1600 3 C o Q m'o C z ` ��.'^,5 Z. ('; %_ 3780 W 104TH STREET i _ r 3- Z , A -'ate P - m A _ HIALEAH, FL 33018 (305) 593-6590 REGISTRATION #29296 e F _ ':6 =SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) 07102120 n too MM m ••.... ,•.•���^`� o EQUAL LEG DETAILS el' JENSROSOWSKI IN)di N o N SH110 "SENTINEL" 6 0F'9 of SH110-LM-NOA A 0 tam m N yy N 00 n£ _ 1/2' MIN, � EXTERIOR OPRONAL ............ VENT HEIGHT 'O BUCK HEIGHT Nm�m PRO Z2 Sic £ �� D.L. OPG. O II O R cn j _ y F m �o N. go -rc z 1/2- MIN. 1/4' MAX. 0 1/4' MAX. GAP o GAP - 09 c 0 � H O w �m m n N A Z � y p Q N z o 2 O V m A X o V Z. 0En i N m O O v O � O • O cv o M L J c ii N •C� a H �i x o� Eu O H IAL ci Scm _ 'zo O, OWEMSTRONGER- Im act Resistant Revision. 111111111; 1j�P PREPARED BY'A LYNN MILLER�Cid � i� WIRfIOWS'8t DOOI'S. 1070 TECHNOLOGY DRIVE _ /i, N. VENICE, FL 34275 `[7n> O. 4%• � CGI WINDOWS AND DOORS, INC. (941)480-1600 z ` `C7 ; ' t,y� 3780 W 104TH STREET . 4,ij �'..� HIALEAH,.FL 33018 _ .REGISTRATION #29296 o __ (305) 593-6590. sA = r � o .m y : _ 'SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) 0 07102/20 FIN DETAILS o m DENS ROSOWSKI SH110 "SENTINEL' N 7 pF 9 oz° SH110-LM-NOA A 2. N+ ,m, m O. m ID W m m V m In A m mw IV m IA c m 2 Cl O. L� O O p+ � w l� 0 W l W. l I I 1 I. 11 O I I T p T � 0 A y N I O W Z+ O N y + N +� m J W+ m Vi 0 O m 0 0 J m O O W tT O A W O N+ O + N N \ A W \ \ \ \ \\ \ \ \ �i \ \ N 0 to 0 In fnn y vDi C. o o o n I E v E E v O E S v E >: `s E I `E `r. ' ' m o p o M O O+ N+ W M D O X V O Dm N+ F E Z E E E I,I :E E i p f F v O O O O O m A m mm 9Q y{ PP •_ m ��nn a"n y "� Fnn Fn �nO G'm m ari- V- m o- VI frl •O c y O y a o O :t fnn S m x x o x X m yy O x y Oy x z O [yn 'm x r O O ' r 'FM r p m: C I v 9£ o rr m p n m m m Z O O m m m m y .m S r N O iJ 7C v p ...1 r 'O x O C C Z. IV F O N n m m o O^ m o.Z COf Fi Z m o. W Fu 5 m m m m m m_ p v m,''- y$n r m A D y vY Z O T r i H O w m m g N m p R. \ o o m m ^ on m D 0 m a Vl 9 y m 0 x m mt°o+ mgm gm Sm' > u w W W Ww w.0 W wgm'ug�m u Z Z Z Z 61°i 'm �om Hmo ywom �wom ° °Z o m m m - v M pA g m m m O�c z zZ z m c o a o c ? Z c O p N !#• � N ? p p D O m D �•adOlmpaCt Resistant PREPARED BY A. LYNN MILLER Revision: ° 4 % Z> o m 9 _........... q /�� Windows & Doors 1070 TECHNOLOGY DRIVE _ o `\ • • tiT , WE1IE STRDROER" N. VENICE, FL 34275 s a ° O • '?O CGI WINDOWS AND DOORS, INC. (941) 4BD-1600 b o ° 1° 9 C z •,Z 37BO W 104TH STREET a ° 0 m z-'z • O _y - o - ` HIALEAH, FL 33018 ° m (305) 593.8590 • 7 T o y : Z = REGISTRATIONJF29296 ILN ° £ m ? SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) 0 07/02/20 o m ��i��/F�''•••••"�'�� �� BILL OF abi JENSROSOWSKI N N '10 ll SH110 "SENTINEL" � .8 OF 9 oz 'SH110-LWNOA A uuli to-.• m - ... 2505 .065 1.745. " .811 2.505 .811 .085 1.550 1.680 S2 - O6 1.245 I .745 TYP. •745 •TMP I / } tots E72 FLANGE FRAME HEAD tots Et FLUSH FRAME HEAD .050 k-t.3s5.. Ett NAIL FIN ADAPTER I ® PRODUCT REVISED as camp Ind with the Florida Building Code NOA-No. 20-0722.09 1.5831.583 .. _ -. .745 1.007 Ex Ig ration Date• 9/22/2025 By /A Miam pade ProducXCo trot _ N z 3.675 ' .065 IYP. 3.175 065 TYR 3.175 065 :n,P 1.368 2.113 VENT TOP CORNER 1a2s 142s .065 ' 1.000 so° 2.505 �!0!7- a .R 3 d "aa E4 O MEETING 1.220 RAIL - FRAME TOP CORNER .500 2505 - eta O 1.220 J # °ID0 0 Z FLANGE FRAME SILL FLUSH FRAME SILL a.043 z O N o r�XB w .500 1.301 1.301 1.788 m O F.065 065 TYP. .065 065 Tom• 065 - -61� 52 W U U ED a z v p W ^ Z 9 (�' °N . OMO M . 2.440 2.440 1.015 O � i - I' a. z W L 1.o15 1.ot5 L LOCK RAIL FRAME BOTTOM CORNER VENT BOTTOM CORNER " c o z M p W 0 2. w o ril is o i U o' (J7 � Q - rn taays 2.195 .745 2846 - .745 2.346 " W E13 FLANGE FRAME JAMB O FLUSH FRAME JAMB 1.892 II,_fl�� 065 = o $ all z c ®-5nW.705 o Z m Z ,o •490 .050TYP. �0.920 ..050 TYP. 1043TYF': ``�111i1111 !/ asa 864 Es HAND RAIL 41GENS � �°vtir•LYN?%�`� 1.395 745 .665 .67� O 5/16" GLAZING BEAD O 700" GLAZING BEAD - 1.450 ,180 .. bt No. 587D5 -_ - - . •' •:' 7 E � '• Q . ST T � F i�S '/'c<ORIDP,•�G��� . 1.395 ,{I1 1.449 .293 .050'r _ I �.180 065 .060 I .550 .050 - lisl�NAL1E\��t F--1.413 u3 FLUSH FRAME COVER 81B SCREW COVER I O SASH RAIL 10 FLANGE ADAPTOR A LYNNMILLER,PE