Loading...
HomeMy WebLinkAboutEngineeringFLORIDA Florida Engineering LLC 4161 Tamiami Trail, Suite 101, Port Charlotte, FL 33952-9204 ENGINEERING www.flengineeringllc.com I Phone: (941) 391-5980 License Number►t30782; #60102 March 1s, '22 Kelley Residence 10680 S. Ocean, #203 ; Jenssenn,Beach, FL 34957� No.� 2205973 Design Criteria, applicable codes and standards: 1. 2020 FBC (7th Edition), Ch. 16 Structural Design 2. ASCE 7-16: Minimum Design Loads for Buildings and other Structures. Ch. 30 Wind Loads - Components & Cladding General Inputs Ultimate Wind Speed (mph) 175 ', Exposure Category '',D Mean Roof height (ft) Enclosure Type Enclosed Internal Pressure Coefficient (±) '0.181 Roof Pitch (in 12) 0 Minimum bldg dimension (ft) 36- Opening no. Width Height Effective wind area (sq. in) Zone External Pressure Coefficient Internal Pressure Coefficient Design Pressures Positive Negative (in) (in) Positive Negative (psf) 1 52.75 63.00 23.08 4 0.90 -0.90 0.18 49.69 -64.69 2 1 36.75 63.00 20.00 4 1 0.90 -0.90 0.18 49.77 -64.77 3 36.75 63.00 20.00 4 0.90 -0.90 0.18 49.77 -64.77 4 105.75 95.50 70.13 4 0.87 -0.88 0.18 48.41 -63.51 5 141.75 95.50 94.01 4 0.85 -0.87 0.18 .47.77. -62.92 RE Y IEWED OR CODE COMPLIANCE ST. LUCIE COUNTY B®CC t o�01111110 /�/ x\GU @@% * No.60102 2 a , �D STATE OF �'��ORIDP.•��c,�N E. GUNDERSON, P.E. #60102 �A