HomeMy WebLinkAboutEngineeringineering LLC FEFLORIDA 4161 Tamiami Trail, Suite 101, Port Cha/otteEFg33952 9204 ENGINEERING www.flengineeringllc.com I Phone: (941) 391-5980 License Number #30782, #60102 March 1st, 2022 Olson Residence 10680 S Ocean #1004° Jensen Beach, FL 34957 Job No 2205976 Design Criteria, applicable codes and standards: 1. 2020 FBC (7th Edition), Ch. 16 Structural Design 2. ASCE 7-16: Minimum Design Loads for Buildings and other Structures. Ch. 30 Wind Loads - Components & Cladding General Inputs Ultimate Wind Speed (mph) 175 Exposure Category D Mean Roof height (ft) 130 ' Enclosure Type Enclosed Internal Pressure Coefficient (±) '018. ` Roof Pitch (in 12) 0'.,, Minimum bldg dimension (ft) 30 Opening no. Width Height Effective wind area (sq. in) Zone External Pressure Coefficient Internal Pressure Coefficient Design Pressures Positive I Negative (in) (in) Positive Negative (psf) 1 141.75 95.50 94.01 4 0.85 -0.87 0.18 60.53 1 , -62.92 2 1 105.75 1 95.50 1 70.13 1 4 1 0.87 -0.88 1 0.18 1 61.40 1 -63.51 2,Z03 -0r7 3 REVIEWED FOR G lII/e,rl� CODE COMPLIANCE\�°XN �®������� STe LUCIE COU14TI(_ r, No. 60102 ,%� BOCC ' r 73 ` STATE OF 47 'VVVyi�� E. GUNDERSON, P.E. #60102 FILE COPY