Loading...
HomeMy WebLinkAboutNOA Sliding Glass DoorM IAM I -DADS MIAMI-DADS COUNTY g PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE(NOA) 2-Ln3-p;S79 www.miamidade.gov/economy, CGI WINDOWS and DOORS, INC.. REVIEWED I-L) , 3780 W. 104"' Street CODECOMPLIANCE Hialeah, FL 33018 p �a� �/ SCOPE: ST. �..UCIE,C0�ov�.i This NOA is being issued under the applicable rules and regulations govenieg3W of construction materials. The documentation.submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas, where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other '.than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ -may immediately .revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane. Zone. DESCRIPTION: Series "Sentinel 150" lummu-m_ _ Sl din Glass Door / wo Reinforcements — L.M.I. APPROVAL DOCUMENT: Drawing No. SGD150LMI-NOA Rev A (former SGD150LMI-NOA Rev O), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by manufacturer, dated 07/21/20, signed and sealed by Lyn Miller, P. E., bearing the Miami —Dade County Product Control Revision stamp with the Notice of Acceptance number and Revision date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant, Limitations: 1. Pocket wall is not part of this approval and to be reviewed by AHJ. 2. See Design Pressure (DP) table: Sizes Vs glass types, Interlock reinforcing & sill riser and the max allowable panels for the entire unit, in sheet 13. See anchor clusters DP capacity in sheet 15. Lower capacity shall control for the entire assembly. For Doors w/ corners, see limitation note 4, below. 3. Max shim not'to exceed'V2" at Head/jambs & ''/z" at Sill (w/ High strength poured & hardened grout). The Sill to be installed w/ anchor type B-2, directly into conc. - 4. Units containing 90' & 135' exterior corners must be limited to Max Dp= +/-60 PSF. See sheet 22 for anchor layout. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved",noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of.this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, -and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and. followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official'. This NOA revises & renews NOA # 19-0603.03 and consists of this page 1 and evidence pages E-1, E-2, E-3 & E-4, E-5 and E-6, as well as approval document mentioned above. FILE ®P� The submitted documentation was reviewed by Ishaq I: Chanda; P.E. NOA No. 20-0729.06 MIAMI-DADE COUNTY Expiration Date: September 22 2025 Approval Date: September 10, 2020 Page 1 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous approvals A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. W10-31 Rev L, titled Series "Sentinel 150 Alum Sliding Glass Door", sheets 1 through 28 of 28, prepared by Al-Farooq Corporation, dated 05/20/10 and last revised on 01/11/16, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC,, TAS 202-94 4)' Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per. FBC, TAS 203-94 , 6) Forced Entry Test, per FBC, TAS 202-94 along with marked —up drawings and installation diagram of 8-panel, .Alum SGD w/ Pockets & 135' and 90' corners, prepared by Architectural Testing, Inc., Test Report No. D8502.01-456-18, dated 12/07/15 respectively, both signed and sealed by Joseph A. Reed, P.E.(submitted under file #15- 0619.06) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC; TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 2.02-94 along with marked —up drawings and installation diagram of 6-panels Alum SGD w/ Pockets & OXXX, prepared by Certified Testing Laboratories, Test Report No. CTLA-3011-W & -W-1, dated May 22 & 23, 2014 respectively, both signed and sealed by Ramesh Patel, P. E. (Note this test reports have been revised by an addendum letter dated SEP 24, 2014, issued by Certified Testing lab.) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of a series 7500FW Vinyl Flange Frame Impact Fixed Window, to qualify DuPont "Butacite" PVB interlayer, Duraseal@ and Super SpacerO insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WA dated 03/03/15, signed and sealed by Ramesh Patel, P. E. along with marked —up drawings and installation diagram of a series 7400PO Vinyl.Impact Flange Frame Project Out Windows, to qualify DuPont "Butacite" PVB interlayer, Duraseal@ and Super Spacer@ insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WB dated 03/03/15, signed and sealed by Ramesh Patel, P. E. along with marked —up. drawings and installation diagram of a series 238 Aluminum Fixed Flange Frame Window with Vent to qualify'DuPont "Butacite" PVB interlayer, Duraseal@ and Super Spacer@ insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WC dated 04/16/15 and revised on 03/09/16, signed & sealed by Ramesh Patel, P. E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E.-1 CGI WINDOWS AND DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE. SUBMITTED B. TESTS (continue) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air'Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 1 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with. marked —up drawings and installation diagram of Alum SGD,_ prepared by Hurricane test Laboratory, LLC, Test Report No. HTL-0080-1208-090, dated July 30, 2010, signed and sealed by Vinu J. Abraham, P. E: (submitted under files #1-2-0119'.04/11-1031.05) along with marked —up drawings and installation diagram of Alum. SGD (OX) prepared by Architectural Testing, Inc., Test Report No. ATI-00733.03-4507-18, dated 08/09/12, signed and sealed by Vinu J. Abraham, P. E. (submitted under files #13-1121.08 /#12-0821.16). C. CALCULATIONS 1. Anchor verification calculations and structural analysis, conformance to, complying with FBC- 2010 and with FBC 5t" Edition (2014), prepared by Al—Farooq Corporation, dated 02/24/16, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300- 09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "Sentry Glas® (Clear 'and White) Glass Interlayers", expiring on 07/04/18. 2. Notice of Acceptance No. 14-0423.15 issued Eastman Chemical Company (MA) for their "Saflex CP-Saflex and Saflex HP Composites Interlayer w/ PET core", expiring on 2/11/18. 3. Notice of Acceptance No. 15-1201.11 issued Eastman Chemical Company (MA) "Saflex Clear and colored glass interlayer", expiring on 05/21/21. 4. Notice of Acceptance No..14-0916.10 issued to Kuraray America, Inc. for their `Butacite® PVB Glass Interlayer", expiring 12/11/16. F. STATEMENTS L. Statement letter of conformance to, complying with FBC 51 Edition (2014), and of no financial interest; dated 02/24/16, signed and sealed by Javad Ahmad, P. E. 2. Addendum letter dated SEP 24, 2014, issued by.Certified Testing lab, signed and sealed by Ramesh Patel, P. E. 3. Lab Compliance statement, part of above referenced test report. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-2 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G. OTHER 1. This NOA revises NOA # 15-0619.06, expiring on Sep. 22, 2020. 2. Test proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as. well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.E. 3. Test proposal # 14-0198, approved on .02/26/2014, signed by Ishaq I. Chanda, P.E. 4. Test proposals # 13-1098, approved on Oct 02, 2013 and revised on FEB 24, 2014, signed by Manuel Perez, P.E., test proposal # 11-1225 dated DEC 16, 2011 signed by Jaime D. Gascon, P.E. Test proposal # 09-1073, approved on Nov. 05, 2009 and E-mail test proposal dated 07-19- 2010, approved by BCCO. 2. Evidence submitted under previous approval. A. DRAWINGS 1. Drawing No. W10-31 Rev O, titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by Al—Farooq Corporation, dated 05/20/10 and last revised on MAR 05, 2018, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS L Letter of conformance to FBC 2017 (6t' edition) and No Financial interest, prepared. by Al— Farooq Corporation, dated 09/14/17, signed and sealed by Javad Ahmad, P. E. G. OTHER 1. This NOA revises NOA # 17-1011.18, expiring 09/22/2020. 3. Evidence submitted under previous approval A. DRAWINGS 1. Drawing.No. SGD150LMI-NOA Rev O (former W10-31 Rev O), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by manufacturer, dated 05/22/19, signed and sealed on 05/23/19 by Lyn Miller, P. E. (Note: This revision consists of Successor Engineer adopting another Engineer work_ as his own and addition of Dow 983 silicone) Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-3 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. REF Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings of an aluminum SGD, prepared by Fenestration Testing Laboratory, Inc., Test Report No.-FTL 19-936, dated 04/15/19, signed and sealed by Idalmis Ortega, P, E. C. CALCULATIONS (submitted under file # 17-1011.18) L None. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E: MATERIAL CERTIFICATIONS i. Notice of Acceptance No. 17A808.02 issued to Kuraray America, Inc. (former E.I. DuPont DE Nemours & Co., Inc.) for their "Sentry Glas®-(Clear and White) Glass Interlayers",. expiring on 07/04/23. 2. Notice of Acceptance. No. 18-0103.01 issued Eastman Chemical Company (MA) (Former Solutia Inc.) for their "Saflex CP-Saflex and Saflex HP Composites Interlayer w/ PET core", expiring on 12/11/23. 3. Notice of Acceptance No. 15-1201.11 issued Eastman Chemical Company (MA) (Former Solutia Inc.) "Saflex Clear and colored glass interlayer", expiring on 05/21/21. 4. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc.. (former E.I. DuPont De Nemours & Co., Inc.) for their "Trofosilg Ultra Clear, clear & color PVB Glass Interlayer expiring 07/08/24. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 61' Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, PX. 2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. 3. Test Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15- 27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal. responsibility for all engineering documents. pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. G. OTHER 1. This NOA revises NOA # 17-1218.20, expiring 09/22/2020. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-4 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 5. New Evidence submitted A. DRAWINGS' Drawing No. SGDI.5OLMI-NOA Rev A (former SGD150LMI-NOA Rev 0), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets l through 28 of 28, prepared by manufacturer, dated 07/21/20, signed and sealed by Lyn Miller, P. E. B. TESTS L. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 , 4) Large Missile Impact. Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with, marked -up drawings and installation diagram of all CGI Windows and Doors, Inc. and PGT Industries, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration. Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E. PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in. proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 711 Edition (2020), dated 07/20/20, prepared by manufacturer, signed -and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies -with ASTM E1300-04, -09, -12. and -16. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20=0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E 5 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY.ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No'..17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White). Glass Interlayers", expiring on 07/04/23. 2. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) (former Solutia, Inc.) for their "Saflex CP- Saflex'and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/2023.. 3. Notice of Acceptance No. 15-1201.11 issued Eastman Chemical Company (MA) (Former Solutia Inc.) "Saflex Clear and colored glass interlayer expiring on 05/21/21. 4. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. (former E.I. DuPont De Nemours & Co., Inc.) for their"Trofosue Ultra Clear, clear & color PVB Glass Interlayer", expiring 07/08/24 F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 07/20/20, prepared, signed & sealed by Lynn Miller, P. E. 2. Statement of Lab compliance as part of the test report. G. OTHER 1'. This NOA revises & renews NOA #19-0603.03, for FBC 2020 update, expiring 09/22/25. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda,. P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval.Date: September 10, 2020 E-6 "SENTINEL" SERIES SGD160A ALUMINUM SLIDING GLASS DOOR DOORS ALLOWED FOR MAX. NUMBER OF PANELS AS LISTED ON DESIGN LOAD CAPACITY CHART ON SHEET 13 OF- 28, USING MEETING STILE COMBINATIONS TESTED AND SHOWN IN DRAWING DETAILS. APPLICABLE EGRESS. REQUIREMENTS PER FBC TO BE REVIEWED BY BUILDING OFFICIAL - THIS PRODUCT HAS BEEN DESIGNED.AND.TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED ANDANSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED ,PER, MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL'SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS" INCLUDING Burr NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR -MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVALISGENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT,- i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND. TO BE REVIEWED BY BUILDING OFFICIAL INSTRUCTIONS: USE CHARTS AS FOLLOWS. STEP 1 DETERMINE DESIGN WIND LOAD REQUIREMENT BASED ON WIND VELOCITY, BLDG. HEIGHT, WIND ZONE USING APPLICABLE ASCE 7 STANDARD. ` STEP 2 DETERMINE DOOR CAPACITY FROM TABLES ON SHEET 13 FOR THE GLASS TYPE AND REINFORCING TO USE. STEP 3 USING CHARTS ON SHEET 15 SELECT ANCHOR- OPTION WITH DESIGN RATING MORE THAN DESIGN LOAD SPECIFIED IN STEP-1 ABOVE. STEP 4 THE LOWEST VALUE RESULTING FROM STEPS 2 AND 3 SHALL APPLY TO ENTIRE SYSTEM. THESE DOORS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED as Compiying with the,Florida Building Code NOA-No. 20-0729.06 Expiretlon Date: 09/22/2025 MIaml-Dade Product Control LAMINATED GLASS AND LAMINATED INSULATING. GLASS` LARGE/SMALL MISSILE IMPACT , T11111111IT TRIG: - Omen ey: - '�. .. SENTINEL 150 ALUM SLIDING GLASS DOOR (LMI) AGK OImDe9t8esiWard 1Wndm6 & D80r$ •.....LYtVv OmcnPOan: =50 00R8AAN WS.INO. ' Data 37 No. 58705 COVER, INSTRUCTIONS 5/22/19 HW.EAH.1L33016(305T593asm (� - ,O •. ZT1� LU` Revision: Rev. By. Re, Oats: PREPARED BY LYNN MILLER".. 1070 TECHNOLOGY DRIVE UPDATED TO FBC 2020, ADDED ANCHORS & BACK AGK 7/21/20 N. VENICE, FL 34275 T '•.• F �'. '•.�O... P. (941)480-1600 SCs •''G\�� Serfeslidodel: Scale: - Sheet: Omdng No. Rer. . �� /`is,7�NAL SGD-150 LMI NTS 1 OF 28 SGD15OLMI-NOA A REGISTRATION #29298 IE��� A LYNN MILLER, P.E. P.E# 58705 6' 3' (8) ANCHORS . CWSTER SHOWN ' m 14' 3 TRACK N ? MAX. HEAD ANCHORS - M 282 13/16- MAX. - - DOOR FRAME WIDTH - HEAD ANCHORS 14' MAX.- - . 48 1/B' ANCHORS IN PAIRS - 2, 3 OR 4 PAIRS HEAD/SILL AT HEAD/SILL/JAMBS AT STILE ENDS SEE SHEET 1 • NOM: PANEL WIDTH 3' O.C. - 6' MAX. ' 1 13/16- FALSE MUNTIN SEE CHART ON SHEET 15 HEAD/SILL - MIN. OPTIONAL A C E FOR CAPACTY JAT CORNERS —� — —; rn 3 TRACK - JAMB ANCHORS M II H. HIr- % J 2 1/8 2 POINT SINGLE LOCK .L OP i. SEE SHEEP 24 FOR DESCRIPTION i II a II__ a a II II gzo REINFORCING • AT INTERLOCKS OPTIONAL .M SEE SHEET 13 FOR CAPACITY 42 1/8 D.L OPG. PRODUCT REVISED as comp)ying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 gy;._ Mlami-Dade Product Control .. I O 13 J z I _ - o' O O m �I 3 o zz Y,n 11 11 J U POCKET B I1 SILL TYPE B2 ANCHORS 2, 3 OR 4 PAIRS AT STILE - 48 8' (SEE SHEET 6, 1 WN -_ENDS INTO CONC. AT 3' O.C. SEE CHART ON SHEET PANEL WIDTH 48 1/8- do 12 & DETAIL M ON POCKET . 15 FOR CAPACITY pgNp- 1V1D�{ .SHEET 23) JAMB ANCHORS (1) WEEP CLUSTER (2) WEEP CLUSTER (2) WEEP TYPICAL ELEVATION TESTED UNIT D.I�NSx D.LO HEIGHT - DOOR FRAME HEIGHT - 9 11/18' D.L.O. WIDTH = NOM. PANEL WIDTH - 6' PANEL HEIGHT DOOR FRAME HEIGHT -1 3/16' .. • • - - - (SEE SHEET 23 FOR .. TYP. INSTALLATION) - ' 3 TRACK III IIII IIII I �LL ANCHORS _II Iv„ (2) WEEP CLUS1Dt 2 WEEP O1ISTER 2 WEEP CLUSTER (1) WEEP CLUSTER \`�tti„I WHIM D—n By: AGK impael Realslent Windows &Doors `� .fir .,........ 41i Lc[NSP �!� %- SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) COWL I DOORS ANDNDOWS, INC. _ No.58705 •' Dw.fp on: DateC ELEVATION 5/22/19 7783W 106TH STREET HW.EM.FL33018 - PREPARED BY LYNN MILLER` Revleldn: Rev. By. Rev. Dote: TECHNOLOGY DRIVE ;0�. F NO CHANGES THIS SHEET AGK 7121/20 NN. V N. VENICE, FL 34275 ie FATE � '•., CO 1DP.._•'` � � , R \ '//SS/QrVAL Serte edeL• Style: Sheet. Draring No. Rev: REGISTRATION 828296 fil1� SGD-150 LMI N.T.S.. 2 OF 28 SGD150LMI-NOA A A LYNN MILLER, P.E. P.E.R 58705" .,I 1 13/16' FALSE MUNTIN MIN. - OPTIONAL x 10 u 0 n 11 lio P 2 TRACKJAMB ANCHORS 6' 3" .. TYP. 14" MAX. ANCHORS IN PAIRS AT HEAD/SILL/JAMBS Al (B) ANCHORS SHOWN ••CLUSTER 2 TRACK HEAD ANCHORS `•� _ 116" MAX. 'RAME WIDTH _ HEAD ANCHORS 14 MAX' HEAD/SILL 2, 3 OR 4 PAIRS AT STILE ENDS SEE SHEET 15 6" MAX: AT SEE 3CHART ON SHEET 15 HEAD/SILL CORNERS FOR CAPACITY - REINFORCING AT INTERLOCKS — OPTIONAL G1 J1 SEE SHEET 13 II II 2 FORCAPACITY M II II 2 POINT 42 1/8" 42 1/8" Oa SINGLE LOCK SEE SHEET 24 D.L.OPG. D.L.OPG. _ 0 FOR DESCRIPTION ,. C] �I Ik=== II ,.-.I1II B1 D1 = CHORS SILL TYPE B2 ANCHORS 2, 3 -OR 4 PAIRS SH WN AT SOLE ENDS AT 3" O.C. SEE CHART ON SHEET 15 FOR CAPACITY < 6' 14' 3. z TYP. (TESTED UNIT) - TYPICAL ELEVATION 01 REFER TO PAGES 14. 15, 17 & 18 FOR WEEP SIZE. �r I a � � J Z. I `t� Z ONN 0 Q y U \ O I 0 m 3 , a� o� YZ � IPRODUCT REVISED m as complying with the Florida - - 00 Building Code a r I NOA-No. 20-0729.06 Ex Iratlon Date: 09/2212025 J P 48 1 8"I—�. -' 1 Miami --Dade Product Control ANEL WIDTH 48 1/8- POCKET PANEL WIDTH .- 2 TRACK JAMB ANCHORS SILL ANCHORS ' D.L. OPENING D.LO HEIGHT = DOOR FRAME HEIGHT - 9 11/16" D.LO. WIDTH - NOM. PANEL WIDTH - 6" PANEL HEIGHT - DOOR FRAME HEIGHT -1 3/16' (2) its awaa (0 ■R aura IIDe: - Drown Br. Impact ReslstEM `` \�Q ........ ��� SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK Windows 6 Doors weae3nmxcDl- \ ��,•' 41GENSF'•, `2-.� ..� CGI DOORS AND WINDOWS. INC. 3780 W 1D4TH SIRM No. 58705 ' Desonp on: - Date: - ELEVATION 5122119 lMEM,FL3301e (305)593.6590 = O By: Ray. Dote: PREPARED BY LYNN MILLER L �Rev. f 41i ••,�VT 1070 TECHNOLOGY DRIVE F i��''•,FGORIDI,,.•' NO CHANGES THIS SHEET AGK 7/21120 N.VENICE,FL34276 (941)480.1600 %ASS/ ••••.••-• �G \� Sedas/ModaL• S-).. Shoe@ - - Dmwfng N. R. REGISTRATION #29296 /�NAL1E���` . SGD-150 LMI 1 N.T.S. 3 OF 28 SGD15OLMI-NOA A A. LYNN MILLER, P.E. P.E.# 68705 oI ivaunurta (a) ANCHORS �6. 3- LUSTER SHOWN CLUSTER SHOWN T!P .... � .... .... (SEE SHEET 22) ... � , 14' EXTERIOR - EXTERIOR 3 TRACK n z .MAX, 149 5/16'•__. I ^^^ 146 9/16'^^T' t ^^^^97 3/4'HEAD ANCHORS M FALSE MUNTIN ANCHORS IN PAIRS OPTIONAL 4B 1/8' rAT HEAD/SILL/JAMBS. M II' H H 0 — 2 1/B D.L. OP �a as Ile II II II B D F HEAD ANCHORS 14' MAX. 2, 3 OR 4 PAIRS HEAD/SILL AT STILE ENDS. SEE SHEET AT 3' O.C. SEE CHART ON SHEET 15 FOR CAPACITY HEAD ANCHORS 2 OR 4 PAIRS AT CORNER STILE ENDS 6' MAX. SEE CHART ON SHEET 15 HEAD FOR CAPACITY SILL CORNERS REINFORCING , AT INTERLOCKS - OPTIONAL SHEET13 SEESCAPACITY P�. H 2 POINT .�. DOUBLE LOCY S SEE SHEET 2 FOR 42 1/8' 42 1/8- DESCRIPTION 2 POINT DOUBLE LOCKS D.L. OPG, D.L. OPG. �• j� �- �• SEE SHEET 24 FOR DESCRIPTION �- p iZ - 2 2 1 13/16- ' LII L 48 1/8' 48 1/8' ' POCKET SILL TYPE B2 ANCHORS SILL TYPE B2 ANCHORS 48 1/8' 48 1/8' JAMB ANCHORS 2 OR 4PAIRS 2, 3 OR 4 PAIRS AT STILE ENDS PANEL WIDTH PANEL WIDTH PANEL WIDTH PANEL WIDTH 3 TRACK c0 i ' AT CORNER STILE ENDS. SEE CHART ON SHEET 15 AT 3' O.C. JAMB ANCHORS ' FOR CAPACITY SEE CHART ON SHEET 15 FOR CAPACITY 3(4)- ANCHORS ' 'EXTERIOR (6) ANCHORS —,----EXTERIOR 3 TRACKAX \ z TYP. CLUSTER SHOWN CLUSTER SHOWN SILL ANCHORS M (SEE SHEET 22) ,,�11111IIIrI PRODUCT REVISED TIN.: Oro.n W. Impact Resistant ��x tky NN '• �0 ••""' •, 4� �% as complying with the Florida SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.L) AGK Windows BI1016 UDUI4 ® 1YAND Balldtng CoGER de (TESTED UNIT) - WINDOWS. DOWS, INC. Q- • �T '• � .. Noe -No.' 20.0729.06 �pICAL ELEVATION DesenpDon: Dater 3780Coll W 1RSH STRE aTsowtomisrRF.Sr ND. 58705 Expiration Date:09/22/2025 ELEVATION 5/22H9 HGIFAH,FL33018 (305) 69365M-t _ n By. Ise-.-, I • L 4—. Rawson: Ray. Dy: Rev. -D.&.- PREPAREDLYNN LLER B r I � � MIamHDade Product Control - 107 LOGY DRIY SATE F, NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL34275 •- ' �s ••..... /,�" Sheet (941)480.1600 - Son /NodM: SWIM D-1.9 No. Rer. REGISTRATION #29296 �S/Q S�G �,,lINAL111 - SGD-150 LMI N.T.S. 4 OF 28 SGD150LM1-NOA A A, LYNN MILLER, P.E. P.E.S 58705 XXX (SHOWN) OXX XXO XXX (REVERSE) FRAME WIDTH DOOR FRAME W. THIS APPROVAL QUALIFIES DOORS WITH APPROVED L NON-REINF. INTERLOCKS CONFIGURATIONS SHOWN WITH 90' AND 135. CORNERS PANEWIDTH .T_ SEE CHART ON SHEET 13 . WHERE STILE CONFIGURATIONS SHOWNON SHEET 22 XXXXXX (SHOWN) OXXXXO XXXXXX (SHOWN) ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO t60:0 PSF © Q EXTERIOR FRAME' WIDTH - NON-REINF. INTERLOCKS ccF nuear nu cuccr 1'{-I� WIN i1 ■r. Win - - - (.Ili 1W Z O`_ © E91RIOR © 135' CORNER DEMIL 'P' ON SHEET 22 EXTERIOR 90• CORNER DETAIL '0' ON SHEET 135' CORNER DETAIL 'P' ON SHEET OPTIONAL IN. LIEU OF J XXXXXO (SHOWN) U U ' EXTERIOR OXXXXO PRODUCT REVISED APPROVED CONFIGURATIONS as complying with the Florida Building Code - NON —POCKETED DOORS (NON -REINFORCED SHOWN) NOA-No. 20-0729.06 SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS Expiation Date: 09/22/2025 THREE (3) TRACKS By; 1 i > (• ci,.,� NOTE: Miami -Dade Product Control 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. a NON-REINF. INTERLOCKS SEE CHART ON -SHEET 13 _j B Q 90' CORNER DETAIL '0' ON SHEEP H N - 0 135' CORNER DETAIL 'P' ON SHEET 22 NON-REINF.O INTERLOCKS OPTIONAL IN LIEU OF J1 SEE CHART ON SHEET 13 - `11111I IIItrr -' Till.: Drown By. Imps Id ResIdent ��� Cj�`1 ,.L... rV SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®WIndows 3 Doors' ;�a��• ' �1ceNs ��C �: ac p on: Data COI DOORSANDWINDOWS, INC, Z 3780iF.WwrIDM o1STPJMa T _ T'c : N0. 58705�- CONFIGURATIONS 5/22/19 (99sesa Revlsfon: Rev. W. Rev. -Dote: PREPARED BY LYNN MILLER '•, 1070 TECHNOLOGY DRIVE SO.'..� TE :'•�; NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL 34275 ' R �. (941)480-1600 %��1 '•.�ORIDP,.•\G��� Sedee/Madel: Scala. - Shoat: Drawing No. - Rev: r/ S� NAL 'SGD-150LMI N.T.S. 5 OF 28 SGD15OLMI-NOA A REGISTRATION#29296 !/r/�111100 A. LYNN MILLER. P.E. P.E.#59705 / CCC I.— IIAI -- — PXXX(SHOWN) XXXP DOOR NNIMPA- MLOL THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE' CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF PXXXXXXP (SHOWN) L! r I DOOR FRAME WIDTH 1a�� .. & H p 1 M K o DOOR FRAME WIDTH PANEL WIDTH NON-REINF. INTERLOCKS l / EXTERIOR U g0 CORNER DETAIL"O' ON SHEET 22\b lJ V Y lJ 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONALAN LIEU OF J DOOR FRAME WIDTH NON-REINF. INTERLOCKS - CZ� is �il-SEE CHART ON SHEET 13 PXXXXXX(SHOWN) O O EXTERIOR HO O OH .EL WIDTH O O XXXXXXP- pOCKET CAVITY NOT BY CGI 135'CORNER DETAIL '0' ON CORNER DETAIL 'P' ONSHEET SHEET 22 _ DOOR FRAME WIDTH - NOT PART OF THIS NOA OPTIONAL IN LIEU OF J DOOR FRAME WIDTH _ r 1 - NON-R]N - -F. INTERLOCKS - 1 0 - aa Y • U U K o M N o PXXXXXO(SHOWN) PANEI WIDTH PRODUCT REVISED APPROVED CONFIGURATIONS OXXXXXP as complying with the Florida Building Code TIBe: Drown By. OMpBo pal % "' `�' v / ��' • POCKETED DOORS (NON -REINFORCED SHOWN) INOA-No. 20.0729.06 SENTINEL 150 ALUM SLIDING GLASS DOOR (L M.L) AGK _ d 3�000tC QC'.•' F . (� ', • SEE SHEET. 13 FOR Op AND REINFORCING OPTIONS Expiration Date:09122/2025 NOTE: CGIDOORS AND WINDOWS•INC. _ z'c i ,No.58705 •� D.=dptian: - Datet' I SI•, ! � �,,.>~ THREE 3 TRACKS BY.— a CONFIGURATION& 5/22119 srREET 31 LEAH, FIL (305�ftesoo 78NE (sos)seses9o0Mlami-Dade _ Product Control POCKETS ARE NOT PART OF THIS APPROVAL PREPARED BY LYNN MILLER ���,, :AND Revfsfon: - Rev. By Rbv. Bte: TO BE REVIEWED BY AHJ. - 1070 TECHNOLOGY DRIVE -, T '•, •% t-`' 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE• FL34275 (941) 460-1600 : CAS''•• <ORIDP,.•' ���� 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. NC�\�� v���O�ALt�ll�\ se Ten/tioeel: swie: Sbeetr Dmwng Na Rev: REGISTRATION#29296 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23, rR r erne or norur� rr nc coo: ireo: r oro ron SGD-150 LMI N.T.S. 6 of 28 SGD150LM1 NOA A XO (SHOWN) Ox 6V FF? wlnru a My l9 V uurniUn U II p �[Oii 1061- --a THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET. 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES ' LIMIT MAX. DESIGN LOADS_TO ±60.0 PSF DOOR FRAME WIDTH \\\ AT 24- O.C. MAX, FRAME WIDTH . Zr `1 1 o G o - Q J1 t HO EXTERIO G1 90, CORNER DETAIL '0' ON SHEET 22 S . CORNER ' OXO (REVERSE) _ �` OPTIONAL IN LIED OF ON SHEET 22 MAX.FRAME WIDTH _._ R REINS INTERLOCKS .. . ' SEE CHART ON SHEET 13 H H 61 G J7 0 o c c / PRODUCT REVISED as c om plying with the Florida' Building Code NOA-No. 20-0729.06 Expiration D2/ Date: 09/22025 -. .. Mlamt-Dade Product Control O l9 V uurniUn U II p �[Oii 1061- --a THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET. 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES ' LIMIT MAX. DESIGN LOADS_TO ±60.0 PSF DOOR FRAME WIDTH \\\ AT 24- O.C. MAX, FRAME WIDTH . Zr `1 1 o G o - Q J1 t HO EXTERIO G1 90, CORNER DETAIL '0' ON SHEET 22 S . CORNER ' OXO (REVERSE) _ �` OPTIONAL IN LIED OF ON SHEET 22 MAX.FRAME WIDTH _._ R REINS INTERLOCKS .. . ' SEE CHART ON SHEET 13 H H 61 G J7 0 o c c / PRODUCT REVISED as c om plying with the Florida' Building Code NOA-No. 20-0729.06 Expiration D2/ Date: 09/22025 -. .. Mlamt-Dade Product Control O EXTERIOR J1 OH 0) OXXO 90' CORNER DETAIL '0' ON SHEET 22 XXXX(SIMILAR) 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIED OF Jt Illflj APPRO ED CONFIGURATIONS NFORcm stlowN) WIT.; Drown By. ImpedHulcinrd .��� lY LYN ��,, . !�,L7 — SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Wlndors 8 000B .``•� ""' ��•"'-,iGENSF-..K" • Descrlp on: - yrztEsmolt0als DOORS ANDW91DOW8, INC. TWO (� TRACKS CONFIGURATIONS Dill.,CGI 5/22119 STREEt 3IAIR H,R�3301 CBMse0asw * j ND. 58705 = z'c ' NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. Revision: Rev. By. Rev. Data:- PREPARED BY LYNN MILLER 1mOTECHNoLOGYDRIVE �J •, �(� NO CHANGES THIS SHEET AGK N. VENICE, FL34275 p STATE F 41- 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 7/21/20 1941) 480 160D o :' <ORID?.:NG\\\ ` 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 5ede /Npdel: scale Sheetr Dmwlng No. Rev REGISTRATION#29296 s/, 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. ' SGD-150LMI N.T.S. 7 OF 28, SGD15OLMI-NOA A ,I�NA1L1���<`� A LYNN MILLER, P.E. P,E.# 58705 WII r I to m0 to .IY 0 o M dL, K U L PX (SHOWN) XP PXXP :ET CAVITY NOT BY CGI PART OF THIS NOA O EXTERIOR tiI U a1 J DOOR FIRME W. L 5 F_ z la gM L7 a L PXX (SHOWN) XXP M I I EXTERIOR INTERLOCKS ON SHEET 13 I DOOR FRAME WIDTH THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES to UMIT MAX. DESIGN LOADS TO ±60.0 PSF a of a NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. O EXTERIOR J1 Q 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 90' CORNER DETAIL 'O' ON SHEET 22 13T CORNER DETAIL 'P' ON SHEET 22 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. OPTIONALAN LIEU OF J7 DOOR FRAME WIDTH 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. NON-RElNF. INTERLOCKS /-ecF nueRr nN euFFT ti •jg� © iv— 0 90' CORNER DETAIL '0' ON SHEEP 22 " 135 CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF Jt DOOR FRAME WIDTH NfIN-RFINF- INTFRI nf:KC _ N1 .r • o � a' �Ci 1 . xxxxp . u 90' CORNER DETAIL '0' ON SHEEP 22 135'. CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF J7 - 7itle: APPROVED CONFIGURATIONS SENTINEL 150 ALUM SLIDING GLASS DOOR (L.IVI.I.) P_OCKEIED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dip AND REINFORCING OPTIONS TWO (2) TRACKS CONFIGURATIONS NO CHANGES THIS SHEET PRODUCT REVISED as eomplyln with the Florida Building Code N OeL-No. 20-0729.06 Expiration Date: 0912212025 gy; Mlaml-Dade Product Control POCKETS ARE NOT PART OF THIS APPROVAL AND TO BE RENEWED BY AHJ. AGK 5rzv1 s Rev. BJ: Rev. Date: AGK 7/21/20 Svies adel: -Scale: sneer OmWin No. Rer. e SGD-150 LMI N.T.S. 8 OF 28 SGD150LMI-NOA A 7AT, Olmpad VYlndgws & DOors•�N 1YEA£C.IPOIIOEEA� •. �y� ',, C� ` � LICENSE'•. cclOoollsANowltmOwa,wc. 37HW�.EAH, F7�3,i0t0� � Y;'• • � No. 58705 ••� �• (Jm) PREPARED BY LYNN MILLER ` XXXX (SHOWN) OXXX XXXO XXXX (REVERSE) XXXXXXXX (SHOWN) OXXXXXx0 NOM. PANEL r= a I;y LJ to I tKIUK % : lJ Ci/ `U` APPROVED CONFIGURATIONS NON —POCKETED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR (4) TRACKS �I THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH- 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES UMIT MAX. DESIGN LOADS TO ±60.0 PSF �NON-REINF. INTERLOCKS - a - p-m NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPUCABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.1.) I AGK D—ptim Date: CONFIGURATIONS 5/22/19 . RevL lon: Rev. W. Ray. Dote: NO CHANGES THIS SHEET AGK 7/21120 3aifas/Lfo&L• 1-1.1 SM1aet Drowfng No. Rei SGD-150 LMI N.T.S. 9 DF 28 SGD150LMI-NOA A PRODUCT REVISED as comp)yIng with the Florlda Bullding Code NOA-No. 20-0729.06 Explratlon Date: 09/2212025 By; _ I s ? 1- L Mlaml-Dade Product Control 11111111f/ ®Impeelfissistent LYNN ' '•. VYNpDnS & DDDIC \ ��� .• . LICENSF COI DOORS AND WINDOWB, MG 378OW10UHS7REEr No.58705 '- HwPAN,FL33018 = Tws) 5s38590 -O PREPARED BY LYNN MI 1070 TECHNOLOGY DRNE Q••• SATE ?� N. VENICE, FL 34275 %, •'• -' (941)48(1•1600 ���•••.c� ORIDP,.,•,'\• REGISTRATION #29296 v15,C)NfiL \G /I 1111101 A. LYNN MILLER, P.E. P.E.fF 58705 I;y LJ to I tKIUK % : lJ Ci/ `U` APPROVED CONFIGURATIONS NON —POCKETED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR (4) TRACKS �I THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH- 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES UMIT MAX. DESIGN LOADS TO ±60.0 PSF �NON-REINF. INTERLOCKS - a - p-m NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPUCABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.1.) I AGK D—ptim Date: CONFIGURATIONS 5/22/19 . RevL lon: Rev. W. Ray. Dote: NO CHANGES THIS SHEET AGK 7/21120 3aifas/Lfo&L• 1-1.1 SM1aet Drowfng No. Rei SGD-150 LMI N.T.S. 9 DF 28 SGD150LMI-NOA A PRODUCT REVISED as comp)yIng with the Florlda Bullding Code NOA-No. 20-0729.06 Explratlon Date: 09/2212025 By; _ I s ? 1- L Mlaml-Dade Product Control 11111111f/ ®Impeelfissistent LYNN ' '•. VYNpDnS & DDDIC \ ��� .• . LICENSF COI DOORS AND WINDOWB, MG 378OW10UHS7REEr No.58705 '- HwPAN,FL33018 = Tws) 5s38590 -O PREPARED BY LYNN MI 1070 TECHNOLOGY DRNE Q••• SATE ?� N. VENICE, FL 34275 %, •'• -' (941)48(1•1600 ���•••.c� ORIDP,.,•,'\• REGISTRATION #29296 v15,C)NfiL \G /I 1111101 A. LYNN MILLER, P.E. P.E.fF 58705 THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90'. AND 135• CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135 CORNER STILES LIMIT MAX. DESIGN LOADS TO f60.0 PSF _ .INTERLOCKS_ /-SEE CHART . SHEET 13\ XXXXXXXX (SHOWN) OXXXXXX0 90' CORNER DETAIL '0' ON SHEET 22 135' CORNER DEMIL'P' ON'SHEET 22 OPTIONAL IN UEU OF J NON XXXXXXXO (SHOWN) OXXXXXx0 90' CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAL 'P' ON SHEET 22 OPTIONAL IN UEU OF J NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. APPROVED CONFIGURATIONS 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. NON —POCKETED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. FOUR (4) TRACKS 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPUCA13LE PER FBC. TIUe: Drown SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK CONFIGURATIONS 5122119 Red91m., - - Rev. Br. I Rev. Oale: NO CHANGES THIS SHEET AGK 7/21/20 SGD-150 LMI I N.T.S. 110 OF 28 1 SGD16OLMI-NOA I A PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 Miami -Dade Product Control ®Impact HOSIS aM .�� ANY LYN�[r Windows R Doors welemcm+eel- � ucErosF ••.l� CGIDOORSANDWINDOWS, MG .••' '. 3780 W 104TH STREET HW.EAH,FL33018 .. = : 140.58705 PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE -�• Z. ��� '. ' 7 O:• Zj Z N. VENICE, FL34275 (941)480.1600 1�� F T S i (�` '••:cr ORIDF�,,••' •� � REGISTRATION 029296 'ONrALtr�Gt A LYNN MILLEW .V.11P.ES 58705 1 DOOR FRAME WIDTH ~s i � H e H la mIi O O M H L PXXXX (SHOWN) XXXXP r DOOR FRAME WIDTH I IpmO a a oM L NOW PANEL WIDTH NON-REINF. I LOCKS rSEE CHART ON S,, 13 i*17 P-11111 _ 1 101 lJ LnJ tXItKIUK lZ) lJ d/ l:J I YI 01 I PXXXXXXXXP (SHOWN) APPROVED CONFIGURATIONS POCKETED DOOR C (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR (4) TRACKS POCKETS ARE NOT PART OF THIS APPROVAL AND TO BE REVIEWED BY AHJ. FRAME WIDTH THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT, FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF 0)-SEE CHART ON SHEET 13 71 Niel,all _� • / L •_J lJ L% L'J l'J Ll \iJ \.Y tXItK1UK t-% 917 CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL''P' ON SHEET 22 OPTIONAL IN LIEU OF J NOTE: 1: CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES `ONLY. 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES.SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. 776a: - _ Dma n By: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) I AGK EXTRUSIONS, BOM 5/22/19 Ravisrom Rev. By: Ray. Date: NO CHANGES THIS SHEET AGK 7121/20 Sed.11110deh Scale: I Sheet: Dm Thg No. Rm SGD-150 LMI N.T.S. 11 OF 28 SGD15DLMI-NOA A v v . PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 0912212025 BY: 1 ca.? 1. •L:b.", - Miami -Dade Product Control tt11i 11 . Resistant "0 ONY LYNN ''',, Olmpact Winders & Doors VIMSTRONSER �, \\�� •' `ICEN ylv CGI DOORS AND WINDOWS, INC. • 3790 W 100H STREET : No. 50705 - HMEAK FL3301a PREPARED BY LYNN MILLER ', vll� 1070 TECHNOLOGY DRIVE ` I l %�;.\x N. VENICE. FL 34275 (941)480-1600 :s '••��ORIDP•.••' LNG`\ REGISTRATION#29296 ,S10NAL 111, I1II,It A LYNN MILLEF2, P.E. P.E.# 58705 ` DOOR FRAME WIDTH 7 I— L w Y� pm O a S M �L 1V © 9 £ lY U la PXXXXXXXX (SHDWN) O O O XXXXXXXXP OXXXXXXXP POCKET CAVITY NOT BY CGI NOT PART OF THIS NOA NOM. PANEL WIDTH NON-REINF. INTERLOCKS SEE CHART ON SHEET 13 DOOR FRAME WIDTH w IC, 0 o IaM L PXXXXXXXO (SHOWN) APPROVED CONFIGURATIONS POCKETED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR (4) TRACKS POCKETS ARE NOT PART OF THIS APPROVAL AND TO BE REVIEWED BY AHJ. THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILECONFIGURATIONS SHOWN ON SHEET 22 ARE -PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF HO O " OH EXTERIOR OH 9D' CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OPRONAL W DEU OF J FRAME WIDTH NO N-REINF. INTERLOCKS k'!) kv l^J lJ kv \� I EXTERIOR LJ 90' CORNER DETAIL '0' ON SHEET 22 '135• CORNER DETAIL'P' ON SHEET 22 OPTONAL W LIEU OF J NOTE 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER F9C. SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK DevufpDon: Date: CONFIGURATIONS 5122/19 Revision: Rev. Rr. Rm. Data: NO CHANGES THIS SHEET AGK 7/21/20 SerlwlModel: Scale: Sheet: Drawing No. R SGD-150 LMI N.T.S. 12 of 28 SGD15OLMI-NOA PRODUCT REVISED - as comp)ying with the Florida 6ullding Code NOA-No. 20-0729.06 Expiration Date:09122/2025 By: Mlaml-Dade Product Control 111li ulr OImpedRssidw �.�� p1Y LYNIV WlDdars 3 Doors GEN • ��/ •1,1gF'•. �� i CGI DOORS AND WINDOWS. INC. �: •• P 37e0 W 10t711 STREET No. 58705 HW EAH, FL 3W18 * - (305) 61rJ8690 - PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE zf (:. IU/� N. VENICE, FL 34275 i�T TE F �` . (941)480.1600 %,c�, FtDRIo(..'GN REGISTRATION #29296 �'�rS TONAL 1e A. LYNN MILLER, P.E. P.E# 58705 C . DESIGN LOAD cAPACLTy - PSP (GLASS) NOLL PANE! WIDTH a+uts . 0008 FT WE HMfl uelrts NIMM OF PANELS u>.aam GLASS TYPES 'A- & 'Al' GLASS TYPES -B- '& 'Bl' LNTERlOCES . W/O REINF. INIBRIOCK9 WTIH RE". EXr.(+) INT.(-) EXT.(+) KQ-) 24-1/8 30-1/8 36-1/8 42-1/8 48-1/8 54-1/8 B2 10 60.0 60.0 80.0 80.0 10 60.0 60.0 80.0 80.0 10 60.0 60.0 80.0- 00.0 10 80.0 60.D 8D.0 80.0 10 - 1 60.0 60.0 80.0 80.0 9 1 53.3 53.3 71.1 71.1 24-1/8 30-1/8 38-1/8 42-1/8 48-1/8 54-1/8 84 10 60.0 60.0 80.0 80.0 10 60.0 60.0 80.0 80.0 10 60.0 80.0 90.0 00.0 10 60.0 6D.0 80.0 80.0 10 60.0. 60.0 -80.0 80.0 9 53.3 53.3 71.1 71.1 24-1/8 30-1/8 35-1/8 42-1/8 48-1/8 • 90 10 80.0 60.0 80.0 80.0 10 60.0 60.0 80.0 80.0 10 eD.D 60.0 80.0 80.0 10 so.0 60.0 80.0 80.0. 9 60.0 . 60.0 80.0 80.0 24-1/8 30-1 a 38-1/B 2-1/8 48-1/8 98 10 60.0 60.0 80.0 - 80.0 80.0 60.0 10 B0.0 00.0 ( 80.0 80.0 10 60.0 60.0 a 60.0 60.0 80.0 1 80.0 . - GLASS TYPES 'B.. 'Al'. 'Bl' ..INTERLOCKS WITH RXINF. EXL(+) [MT.(-) 24-1/8 30-1/8' 35-1/8 42-1/8 48-1/8 54-1/8 102 10 - - 60.0 60.0 10 - - 60.0 eD.O 10 - - 60.0 60.0 10 - - - 60.0 60.0 10 - 80.0 80.0 9 - - 54.4 54.4 24-1/8 30-1/8 35-1/8 42-1/8 48-1/8 53-1/8 108 10 60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 60.0 9 - - 54.4 54.4 24-1/8 30-1/8 36-1/8 42-1/8 48-1/8 114 10 - - 60.0 60.0 10 - 80.0 60.0 .10 60.0 60.0 10 - 60.0 60.0 9 - - 80.0 60.0 24-1/8 30-1/8 36-1/8 48-1/8 120 10 - 60.0 60.0 10 - - 60.0 1D - - :1 60.0 60.042-1/8 10 - - 60.0 60.0 9 - - 60.0 60.0 1 GLASS CAPACITY CHARTS NAM. PANEL WIDTH NAM. PANEL WIDTH E' "N..PA.E.LIDTH tNOM. PANEL WIDTH APPLICABLE EGRESS REQUIREMENTSS TO BE REVIEWED BY AHJ. 1 1 nnTBLOmm INTERLACES W/O BELNP. WTPH Bill". EB FH.1 ie in N \ N N N PRODUCT REVISED as complying with the Florida Building Code SILL RISER ITEMS ES OR E6.1 ARE REQUIRED FOR LOADS NOA-No. 20-0729.06Ex iratlon Date: 09/22/2025 ABOVE +60.0 PSF ONLY. P BY- 1 c-7 I. MlamFDade Product Control NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 RDe: I-Pe9tH68i31 ilt SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®l{Mdwits 3 Doom wom mrollcel- p Oat. CGI DOORSAND WINDOWS.IN4 37so W 104TH STREET GLASS CAPACITY CHARTS 5122/19j Ravlsion: Rw. BY Rev. Oat. PREPARED BY LYNN MILL 1070 TECHNOLOGY DRIVE N9CHANGES THIS SHEET AGK 7121120 N.VENICE. FL 34275 (941) 480.1600 Serf/Model, Scale: Sheet- Omwing No. JR.r. SGD-150LMI N.T.S. 13 OF 28 SGD15OLMI-NOA A REGISTRATIONgzszse . �1j 11 .rll vle.�t iiv 140- 58705 a7EATS F •' ✓✓�� •'•'40RIDi".••' 4��: ANAL �Illllllll111 A. LYNN MILLER, P.E. P.E.# 58705 3/16' ANN. GLASS 3/113' ANN. GLASS _ 3/16- HEAT STREN'D GLASS - 3/16' HEAT STREN'D GLASS - - 075' Intedayer 075' Interayer - Saflex CP With PET Core Saflax CP With PET Core 075' Interl er oY - 075' Intedayer - By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' Saflex CP With -PET bore 'Eastman Saflex CP With PEr Coro .. ; OR OR By Chemical Co! By 'Eastman Chemical Co.' 090' Intedayer Saflex Clear And Color Gloss 09D' Interloyer Soflex Clear And Color Glass R 090' Interla Y er 090' Interia er y ' By 'Eastman Chemical Co! By 'Eastman Chemical Co.' Saflex Clear And Color Glass 'Eastman Saflex Clear And Color Glass OR OR By Chemical Co! By 'Eastman Chemical Co.' 090' Intedayer SentryGlas 3/B' AIR SPACE 090' Interayer SentryGlas OR 090' Interloyer 3/8' AIR SPACE OR 090' Interayer , By 'Kuraray America, Inc.' OR By 'Kuraray America, Inc.' SentryGlas By. Kuraroy America, Inc.' SentryGlas By Kuraray America, Inc.' 090' Intedayer 3/16' TEMP. GLASS Trosifol PVB OR 090' Intedayer Trosifol PVB OR 090' Intedayer 3/16- TEMP. GLASS " OR .090' .Intedayer By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' Trosifol PVB . Trosifol PVB By Kuraray America, Inc.' By Kuraray America, Inc. 3/16' HEAT STREN'D GLASS 3/16' HEAT STREN'D GLASS 3/16- HEAT STREN'D GLASS 3/16- HEAT STREN'D GLASS . C SILICONE _ GE SCS 1200 DOW CORNING 791, - SILICONE GE SCS 1200 DOW CORNING 791, SILICONE GE SCS 1200. SILICONE GE SCS 1200 ' m 898, 983 & 995 m ? 899, 983 & 995 m DOW CORNING 791, m DOW CORNING 791, M7 m M1 XL EDGE SPACER S m 899. 963 & 995 z 899, 9B3 & 995 Si. STEEL BY 'CARDINAL' c u M1 - a M1 XL EDGE SPACER - 'CARDINAL' 19 1O OR ro SETTING BLOCKS n DURASEAL BY 'QUANEW AT 1/4 POINTS ON UM 0RL DURASEAL BY 'QUANEX' 14 O SETTING BLOCKS AT 1/4 POINTS ON 9 LffES O OR SUPER SPACER BY 'QUANEX' P'i WIDER THAN.38' EPDM' py OR SUPER SPACER BY 'QUANfCX' " r..� W 1 WIDER THAN 36' DUROMETER 85t5 N 9 SETTING BLOCKS 1EPDM AT 1/4 POINTS ALL SIZES O w DUROMETER 85t5 O W 1 SETTING BLOCKS. [� . EPDM DUROMETER 85*5 .. _ AT 1/4 POINTS ALL SIZES EPDM W WWW DUROMETER 85f5 GLASS TYPE 'A' GLASS TYPE 'Al' GLASS TYPE 'B' GLASS TYPE 'BI' 7/16- OVERALL LAM. GLASS - 1' OVERALL INSUL LAM. GLASS 7/16' OVERALL LAM. GLASS - - - 1' OVERALL INSUL LAM. GLASS ' - PRODUCT REVISED GLAZING OPTIONS as complying with the Florida ' Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 gyp _ I P-7. I • L /nn.L - Miami -Dade Product Control 7111. Orrin SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK p on: Date; GLAZING DETAILS 5/22/19 Rav7slon: �Ray. BY: R. Date: ADDED BACKBEDDINGS AGK 7/21/20 Serfes/Model• - Swfe, Sheet. Om"In9 No.,' Rar. SGD-150 LMI N.T.S. 14 of 28 SGD15OLMI-NOA A IIIII II IJf/// . ......,!V�,''�, OlmpectRealclent MI111DWS&Do011111 111elaemlalaal- �' LICENS�•��(� � @•: C61 DDDRS AND LNNDOW3, INC. 3780 W 10i7H STREEr �'! :• -N0..58705 HKEAH,FLW018 (305)5936M -D PREPARED BY LYNN MILLER 0 O 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 7 TE F %��••••, •C'�� (941)480.1600 ORION •' ! S •„\ �IzONALI NG��` REGISTRATION#29298 i A LYNN MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF (ANCHORS) NOLL PANEL VADTH INCNF9 FRAME INCHES . ANCHORS (TYPE A. B & C) ANCHORS (TYPE 82) CLUSTER AT snUEAfPERWM ENDS CLUSTER AT STILVMERIDCK ENDS 4 a 'e 4 a 8 ExT.(+) TNT.(-) INi.(- .(+) TNT. -) ENT.(+) INT.(-) INT.(-) INT.-) 24-1/8 30-1/8 36-1/S 42-1/5 48-1/B 54-1/8 - 82 80.0 - BOLO - 76.2 80.0 - %62.871.1 - 68.7 80.0 - 63A 80.0 - - 59.5 71.1 71.1 24-1/B 30-1/e 36-1/8 42-1/8 48-1/8 54-1/8 84 80.0 - - Ba.O . - - 80.0 - - 80.0 - - 75.5 80.0 - 71.5 BO.O - 67.8 00.0 64.3 .80.13 - 62.3 80.0 - 59.1 -80.0 -1 80.0 58.4 71.1 71.1 55.3 71.1 71.1 24-1/8 30-1/a 36-1/8 42-1/8 48-1/8 90 BOLO Ba.o 79.7 BOLO 78.880.0 - 89.2 80.0 85.0 80.0 81.8 BOLO 58.7 BOLO BOLO 58.7 BOLO B0.0 53.7 60.0 BOLO 24-1/8 30-1 8 38-1/B- - /e 48-1/B 96 80.0 - - - 80.0 - - 73.8 B - 69.9 80.0 - 83 B0.0 80.6 BOLO - 57.0 '80.0 54.0 80.0 90.0 51.9 77.9 BOA 49.3 7&9 BOA 24-1/a 30-1/a 36-1/a 42-1/8 48-1/8 54-1/8 102 ISOM 60.0 - BOLO - - 60.0 - - 50.3 80.0 60.0 86.2 60.0 60.0 82.7 60.0 60.0 50.0 60.0 60.0 47.9 60.0 60.0 45.5 BOLO BOLO 44.3 54.4 1 54.4 42.0 54A 54.4 24-1/13 30-1/8 36-1/e 42-1/9 48-1/8 54-1/8 108 BOLO 60.0 60.0 - - 60.0 - - 59.3 60.0 60.0 52.5 60.0 60.0 49.1 50.0 60.0 46.6 60.0 80.0 . ".5 41.6 60.0 54.4 60.0 54.4 42.2 38.4 60.0 60.0 24-1/e 30-1/8 36-1/8 42-1/8 48-1/8 11.4 60.0 60.0 60.0 - 57:2 51.9 60.0 60.0 49.2 45.9 60.0 60.0 43.8 41.5 60.0 '60.0 39.4 24-1/8 3a-1/8 36-1/8 42-1/8 48-1/8 120 BOLO - - Bu.O 56.9 60.0 60.0 54.0 4B.8 60.0 80.0 46.3 43.1 60.0 60.0 40.9 38.9 58.4 60.0 36.91 l ■rA1.ew 7YEICAlf-ANCHORS IN --� SLUISTERS AT MTG. STILE TYPE 'A'- 1 /4" ULTRACON BY 'ELCO' (Fu-177 KSI. Fy-155 KSI) & INTERLOCK ENDS, SEE 213Y AT BEAD THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE _ CHART FOR QUANTITIES STRI JAMBS 1-1/4" MIN. EMBED INTO CONCRETE GE DIST. THRU 1BY BUCKS OR DIRECTLY INTO MASONRY _ 3 5/B' 1-1/4" MIN. EMBED MASONRY (0 JAMBS) INTO 29Y WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD - TYPE 'A'- 1/4" KWIK-CON 11+ BY 'HILTI'(Fu-138 KSI, Fy=137 KSI) AT BEAD, INTO 2BY WOOD BUCKS OR WOOD STRUCTURES ILL 1-3/8" MIN. PENETRATION INTO WOOD JAMBS ANCHOR TYPE A TYPE 'B'- 1 /4" ULTRA ON BY ' A' (Fu-177 KSI. Fy-155 KSI) BY11 AT HEAD THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE OR WOOD STRUCTURES 2" MIN. EMBED INTO CONCRETE (0 HEAD) JAMBS 1-1/4" MIN. 'EMBED INTO CONCRETE OR MASONRY (0 JAMBS) 1 /4" ULTRACON+ BY 'DEWALT' (Fu-164 KSI, Fy=148 KSI) TYPICAL ANCHORS IN THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE CLUSTERS AT MTG, STILE & INTERLOCK ENDS, 1-3/4" MIN. EMBED INTO CONCRETE CHARTF R OUANTITIES 1-1/4" MIN. EMBED INTO CONCRETE OR MASONRY (0 JAMB TYPE 'C'-' 1 /4" DIA SELF DRILLING SCREWS (GRADE'S CRS) EDGE to °3 5/8" : ' 'CONCRI AT HEAR INTO MIAMI-DADE COUNTY APPROVED MULLIONS ' OR OR JAMBS INTO METAL STRUCTURES. (HEAD/SILL/JAMBS)' (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) MIN STEEL• 1/8" THK. MIN. (Fy - 36 KSI MIN.) (S1FEl. IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ANCH�RETYPE 'B2'- 1/4" DIA. ULTRACON BY 'ELCO' (Fam177 KSI. Fy-155 KSI) DIRECKSI CONCR AT 3IIJ. 1 /4" DIA. ULTRACON+ BY. 'DEWALT' (Fu-164 KSI. Fy-148 KSI) POURED & HARDEN�N=IMETAM o DIRECTLY INTO CONCRETE NON-SHRIN HIS GH-STRENGTH GROUT:. 1-3/4" MIN. EMBED INTO CONCRETE f'C = PSI MIN. 1/4" KWIK-CON II+ BY 'HILTI' (Fu=138 KSI, Fy-137 KSI) NOT CGI: MUST TRANSFER SHEAR INTO 25Y WOOD BUCKS OR WOOD STRUCTURES L S TO STRUCTURE 1-3/8" MIN. PENETRATION INTO WOOD t O""" m DEWALT ULTRACON+ AND HILT] KWIK-CON 11+ " o ANCHORS LIMITED TO A MAX. SHIM SPACE OF 1/4". S .e ANCHOR EDGE DISTANCES INTO CONCRETE OR MASONRY m 2-1/2" MIN. .3 5 - INTO WOOD STRUCTURE, - 1" MIN. _ TYPICAL ANCHORS IN CLUSTERS AT MTG. STILE OR & INTERLOC C R QUANTITIES KSI. I 3 5/.8" ... .. )NCRETE- • v. La u iv m =i ANCHOR TYPE A o RU-4aY-WOE INTO 3 KSI CON 151' W00 BUCKS SEE NOTE ET 1 �n METAL STRUCTURES ,SEE SPEC BELOW & INTERLOCK ENDS, SEE CHART FOR QUANTITIES . EDGE 3 5/8" DIST. ANCHOR TYPE C INTO METAL STRUCTURES \ SN 0 OR APPROVED MULLIONS M SEE SHEETS 18 FOR OPTION! AND SHEET 13 = - s TYPICAL ANC ORS a IN CLU S a AT MTG. LE 1 3 • & INTERLOC ENDS SEE C FOR Q IES NOTEc INTO METAL STRUCTURE - 3/4" MIN. CHOR TYPE B2 ANCHOR CAPACITIES LISTED ON THIS SHEET TO BE USED IN WOOD AT HEAD OR JAMBS SG P 0.55 MIN. DI LY INTO 3 KSI CONCRETE CONJUNCTION WITH GLASS CHARTS ON SHEET 13 LOWER CONCRETE AT HEAD, SILL OR JAMBS f c - 3000 PSI MIN. APPLICABLE VALUES CONTROL 3 TRACK SYSTEM SHOWN ALSO C-90 HOLLOW/FILLED, BLOCK AT JAMBS ern - 2000 PSI MIN. Wile: Drawn W. APPLICABLE TO 2 AND 4 TRACK FRAMES. PLEASE. SEE PRODUCT REVISED SENTINEL 150 ALUM SLIDING GLASS DOOR (LM.I.) AGK FOLLOWING SHEETS FOR DETAILS. _ as Builldingdingcompwith the Florid Code scdptlan: Date: LIMIT EKT.((+) LOADS TO 60.0 PSF FOR DOORS W/O REINFORCING ALL SIZES NOA-No. 20-0729.0 LIMIT EXT.(+) LOADS To 80.0 PSF FOR DOORS W/ REINF. UPTO 96 IN. HT. Expiration Date:09/22/262 ANCHOR LOAD CHART/ANCHOR DETAILS 5/22/19 LIMIT EXT. +) LOADS TO 60.0 PSF FOR DOORS W/ REINF. ABOVE 96 IN. HT. UPTO 120 IN. HIGH. By: I ca- Ray. 8y: R4v. Dote: c W000 BUCKS AND METAL STRUCTURES NOT BY CGI WINDOWS INSTALLATION CONDITIONS SHOWN APPLY TO t Control ADDED ANCHORS AND RE -FORMATTED SHEET AGK 7121/20 MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND BOTH 2 TRACK AND 3 TRACK SYSTEMS WITH Series/uodeL• Sects: Sheeh Orawlri9 Na Ray. TRANSFER THEM TO THE BUILDING STRUCTURE. STD. FRAME HEAD AND SILL SGD-150 I M1 N.T.S. 15 OF 28 1 SGD16OLMI-NOA A "I ANCHOR TYPE A INTO 2BY WOOD BUCKS OR WOOD STRU`Ct'F,lfRE611t/tt7 OImpact Baslsfellt �.�� �0 ........... Wladows 8 noors �� .•' t\GENSF' .1�� t1reB2lmtall9R- � Q•. �•� CGI COORS WINDOWS. Ns, INC. /j Na. 58705 104THSTREET HMEAH.FL33016 (306)593-B8 _ ZSATE, PREPARED BY LYNN MILLER '0•'r-�Fo 1070TECHNOLOGY DRNE Q I(7` N. VENICE. FL 34275 %'��'• F(ORIOF`.•'• \?� (941) 480-1600 ••••• REGISTRATION #29296 / Si ��NAL I' : A. LYNN MILLER. P.E. P.E.# 58705 SEE SHEET 15 FOR ANCHORS Z EDGE DIST. 3 5/8" EDGE N pprn 'j.d • '1d' u 9 O a 11; 11 It POURED h HARDENED HIGH STRENGTH GROUT NON -SHRINK, NON-METALLIC f`o - 5000 PSI MIN. NOT BY CGI WINDOWS MUST TRANSFER SHEAR E7 LOADS TO STRUCTURE O JF O J 1 1 .u.... ... a ;E'DIST.•• .y3 511 m SEE SHEET 15 FOR ANCHORS DGE+DIST. filI •, 3 5/8'• a • n. O 11 11 11 11 BE 11 1 111. � 40, 11 WEEP SIZE 1/:4 X 1/B" REFER TO SHEET 15 FOR VARIOUS INSTALLATION CONDITIONS. OPTIONAL SLANT SILL ADAPTORS PRODUCT REVISED as complying with the Florida Building Code NOA-No. . 20.0729.06 Expiration Date: 09/2212025 BY: _ 1 c --7 1. L 46, DECORATIVE Miami -Dade Product Control SILL COVER OPTIONAL 1 SILL RISER E8.1 READ. FOR LOADS ABOVE.+60 PSF 3 KSI CONC. It -'DEBT •• • 3 5/8' _ THREE (3) TRACK DOOR DETAILS -�1111111 !!! rue: Drawn ey Impact Raddald .��� �pNY • • ,NN�''�., SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK Yfindows o&�Doora `� Pit ,• �10ENs` . �C�� ; ••:� = No.5B705 rip on: Dale: CGIDOORSANDWMDOWS,INM 87sOW1041HSTRFEr 3-TRACK DOOR DETAILS 5/22M8 HAIFAFI,FL33018 _ �5a3.es3 _ 1= - - `� . '• trillo Revision: - Ray. By. Rev. Date: PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE Q '•, j ' NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL34275 ' T F g/ ' (941)48D-1600 i �s •. . . . . . <..•'G��� '// s/ONAL Series/Model: SmI.: Sheet: Dmwin8 N.. Ra SGD-150LMI N.T.S. i 16 OF 28 SGD15OLMI-NOA A I REGISTRATION#29296 I //l 111110 , A LYNN MILLER. P.E. P.E.d 58705 F01 R �• I D BEARINGSHIM r I—r WOOD STRUCTURE m' s] EXTERIOR E O REINF. AS REDD. O SEE CHART ON SHEET 13 FOR CAPACITY INTERLOCK (REINFORCED) DOOR O 1/2' MAX. INTERLOCK (REINFORCED) #10 X 1-1'/4- SS PH S 1 PER C r ^I 1 3 PER PANEL J I AT 18' FROM EACH END AND AT MIDSPAN f8 X 3/4- SS FH SMS - 1 PER CUP NCHORS ING O ACTRAGAI 1/4- MAX. RODUCT REVISED complying with the Florida gilding Code �A-No. 20-0729.06 :piratlon Date: 09/22/2025 - 1: _ 1.-7 1. G4-1' Iarni-Dade Product Control TYPICAL ANCHORS SEE ELEV. FOR SPACING o DOOR FRAME WIDTH Lg FIXED PANEL EXT. _I I l l I III 11j1 1111a: Dra" By: Impact D R �� ......` SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®ftdows&Resistant weRtmmilm+- � Q-. • F Z No. 58705 = escnp x polo; COIDOORSAND WINDOWS. INC. 378o W 1041H SIR�T 3-TRACK DOOR DETAILS 5/22M9 H1MZMtFL3.901a (a0s) 5e3 ess0 = r - r ••TST-' IO� (V Ravfs(on: Rev. BY: Ray. Data. PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL 34275 (941)48(1-1600 \ �C�s •'•F�ORIUM,.•'G�=� i1��AL1N �\\` Sarlea/1lodeL• Scala: Sheaf oroninB Na. - Re, SGD-150 LMI N.T.S. 17 of 28 SGD15OLMI-NOA A REGISTRATION #28298 A. LYNN MILLER. P.E. P.E.# 58705 SEE SHEET 15 FOR ANCHORS SEE SHEET 15 FOR ANCHORS- ' m WEEP SIZE 1/4" X 1,/8" Zq _ EDGE DIST. 1 3/4" Z b EDGE DI5i. 1 3�4" mN n;• '� 3 KSI CONC. mfx e:• '-j v 3 KSI CONC. REFER TO SHEET 15 FOR VARIOUS INSTALLATION CONDRIONS 4 p d• p ° N a 0 14 n �a S POURED & HARDENED HIGH STRENGTH GROUT NON —SHRINK, NON —MET C f,C= 5000 PSI MIN. NOT BY CGI WINDOWS MUST TRANSFER SHEAR SILLISER REQD FOR LOADS ABO +60 PSF OPTIONAL SLANT SILL ADAPTORS DECORATIVE SILL COVER OPTIONAL 1 SILL RISER OPTIONAL FOR LOADS ABOVE +60 PSF PRODUCT REVISED as complying with the Florida Building Code NOA-No. , 20-0729.06 Expiration Date: 09/22/2025' By. Ls ,. I. Miami -Dade Product Control • — .• I L 9 U D A U 4 ri d 3 KSI NCEDGE t •: .•-. .r • RSEE 3 KSI CONC.CO DISi. EDGE DIST. 1, 3/4SEE SHEET 15 FOR ANCHORS EET 15 FOR ANCHORS ll llf l// TWO (2� TRACK DOOR DETAILS \ _ n o: Omrn By: Impact Heslrnelrt ``111ll 0 : r S NTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Windows & Doors �� .•' 41�ENsF'•.!� - Dea p on: Dte; CGI DOORS AND WINDOWS. INC. ' Na. Sb705 '• 2-TRACK DOOR DETAILS 5I22/19 376D W 10/1H STREET ly5)68�W 18 _ = O Rev. By. Rev. Dale: PREPARED BY LYNN MILLER 7 �R.W.i­ aC. O1070 TECHNOLOGY DRIVE ���'•F NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL3427s (�` '•.F<ORIDP-.•' SerJea/Alode4 Bmle: Sheet: xfigNo.Rev. jlSGD150LMI-NOA REGISTRATION#26296'vALSGD150A N.T.S: 18 OF 28 A A LYNN MILLER. P.E. P.E.# 68705 TYPICAL FOR LL ANL;hVhb LEV. FOR SPACING 1/2' MAX. )AD BEARING #10 X 1-1/4" SS PH SMS SHI c 1 1 PER CLIP M2 8 X 3/4' SS FH SMS W 1 PER CUP Z o U O�' O M •a e f •; E6 FIXED PANEL O.L.O. L1BY WOOD BUCKS SEE NOTE SHEET 1' 1/2" MAX. �\ SEE NOTE SHEET 1 EXTERIOR O 0 O O O PRODUCT REVISED Ea Es ASTRAGAL as com 1y.1 with the Florida Building Code INTERLOCK NOA-No. 20-0729.06 (REINFORCED) Expiration Date: 09/22/2025 E}CTERIOR BY: 1 s-7 t• 44—s MlamF-Dade Product Control DOOR FRAME WIDTH L� o #10 X 1-1/4' SS PH SMS 1/4' MAX. z 1 PER CUP LOAD BEARING o 1/2' MAX. SHIM METAL LOAD BEARING - SEE EC ANCHORS #8 X 3/4' SS FH SMS STRUCTURE SHIM FOR SPACING 1 PER CUP TYPICAL ANCHORS ' SEE ELEV. ' FOR SPACING ra n O a . �. .. • .'. W W to _ DOOR FRAME WIDTH , WO (2) TRACK DOOR DETAILS FIXED PANEL 11111 L 1 I i t (Tt, TIDa Om.n W. Realaltult SENTINEL 150 ALUM SLIDING SS DOOR (L.M.I.) AGK OImpact Wtndowa & DooDT rre9Emmltml- � Q-_• �:F� At nn: ootee CGI DOORS AND WINDOWS, INC. 3790 w 104TH STREET No. 58705 2-TRACK DOOR DETAILS 5122/19 EAH�33018 HIAL-' - 7J •'. ` �� �` Revisfan: Rev. By: Rev. Data PREPARED BY LYNN MILLER NO CHANGES THIS SHEET 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 :. ���'.• StATEOF (V` AGK 7/21120 (941)480.1600 N�\\`• Smlm/MadeL• Scwla Sheet: DmWnp No. Rev. REGISTRATION#29296 /ONAL1 SGD-150 LMI N.T.S. 19 of 28 SGD15OLMI-NOA A A LYNN MILLER. P.E. P.E.# 58705 SHEET 15 FOR ANCHORS io- 1. ____ POURED. & HARDENED HIGH STRENGTH GROUT NON -SHRINK, NON-METALLIC •f'c.- 5000 PSI MIN. - NOT BY CGI WINDOWS .MUST TRANSFER SHEAR LOADS TO STRUCTURE O \—SEE SHEET 15 FOR ANCHORS FOUR (4) TRACK DOOR DETAILS SD SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) I AGK 4-TRACK DOOR DETAILS 5122/19 R.4.1 n: Rev. W. I Rev. Oat,. NO CHANGES THIS SHEET AGK 7/21/20 SGD-150 LMI I N.T.S. 120 OF 28 1 SGD15OLMI-NOA I A EFER TO SHEET 15 FOR VARIOUS ISTALLATION CONDITIONS. WEEP SIZE OPTIONAL SLANT SILL ADAPTORS DECORATIVE - SILL COVER OPTIONAL 1 SILL RISER E8.1 REOD. FOR LOADS - ABOVE +60 PSF - - SILL RISER I REOD. FOR LOADS ABOVE +60 PSF 1 t� 1 PRODUCT REVISED as complying with the Florida Bunding Code NOA-No: 20-0729.06 Expiration Date: 09/22/2025 _ - By: Miaml-Dade Product Control ®Impeel Heslsield .� • "" � ' Windows A D00R ��.•'' OCENs� •. ll� rrem arRuwam- ?� CGI DOORS AND WINDOWS. INC. _ ;'� N0.58705 3780 W iDM STREETHIALE P05)5 34&590FL3- y PREPARED BY LYNN MILLER 'D 1070 TECHNOLOGY DRIVE %�T •• ATE F : \CV�� N. VENICE• FL34275 i�s •:",<ORIDt•.••' \` (941) 480-1600 ,� 7S'�O•....... \0 REGISTRATION#29298 L/1111 AL11111� A. LYNN MILLER, P.E. P.E# 58705 SEE ELEV. FOR SPACING 1/2• MAX. LOAD BURR SHIM U Zy � A c4 :•�•.: 1X8 OR TYPICAL c FOR BUCK WOOD STRUCTURE 9 EXTERIOR L2 1/2- MAX. LOAD BEARD SHIM EXTERIOR 0 0 0 o TYPICAL ANC) SEE ELEV. FOR SPACING m N c' n 1 /4- MAX. LOAD BEARD L3 SHIM EXTERIOR #10 X 1-1/' 3 PI AT 18' FROM I AND AT #8 X 3/4- SS FH 1 PER TYPICAL ANCHOR! SEE ELEV. FOR SPACING N PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0729.06. Explratlon Date: 09122/2025 BY: _1sr—'2 1-Z41—._ Mlami-Dade Product Control �OImpact 71De: - Dm n 8), ' RaSlst nt Windows 8 Doms �,.�� ��•;'LYn� • • N N4,, SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK wt'�mcDeun- \� �\� ... _• '� 1.1GENSC' •:, l� ..-' D.cnp on: Date: CGI DOORS AND WINDOWS. INC. 4-TRACK DOOR DETAILS 5/22/19 37BOW104TH SIAEET H14FAKFLM01e (305) _ No. 58705 FOUR (4) TRACK DOOR DETAILS -p ; Revision: Rev. eY• Rev. Data: PREPARED BY LYNN MILLER _ " 1070 TECHNOLOGY DRIVE �3 '. 2.l Z, O : NO CHANGES THIS SHEET AGK 7/21120 N. VENICE, FL34275 (941)480-1600 ���\ O TA.T OF • %'•_,•RC 0RIO�•. •'' Serfes/HodeL• Scele: Sheet: DroW.9 No. Rev: , is �� , ''��;10AIAL'a SGD-150 LMI N.T.S. 21 D 28 SGD150LMI-NOA A REGISTRATION#29296 O135' CORNER #10-24 % 1/2- FH THREAD CUTTING SCREWS AT 6' FROM ENDSI & 12" O.C. EXTERIOR 4BLE FOR OUTSIDE CORNERS ONLY AT 6' FROM ENDS & 12" O.C. 1 3/4' 3 5/8- 3 5/8" (4) ANCHORS ,I- • ,y\" (4) ANCHORS 6 - �6 8. (6) ANCHORS (6) ANCHORS y �6 �6 3 8 3' I 3• 8, 3 J ' (8) ANCHORS p• (8) ANCHORS 7i8e: DmrnDY: s 3 s 3 g• I 3'e. 3' 8' SENTINEL 150 ALUM SLIDING GLASS DOOR (I-M.I.) AGK TWO (2) TRACK TFIREE (,;) TRACK FOUR (41 TRACK TWO (2) TRACK THREE 0) .TRACK FOUR (4) TRACK Mee.in! CORNER DETAILS R-Nf.. NO CHANGES THIS SHEET SGD-150 LMI I N.T.S. 122 OF 28 Data: 5/22/19 Ray. 8Y: Rev. Data: AGK 7/21/20 Dmwing No. R. SGD150LM1-NOA I A #10-16 X 1/2- HH SELF DRIWNG.SCREWS AT 6' FROM ENDS & 12" O.C. PRODUCT REVISED. as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/2212025 MiamHDade Product Control NR ®irhrenaSL:mmrsmaLIDFo n- ;• .•NLN �Icr_rasF •., (�� ; C,• COIDOORB ANDWItiDOW8, INC. 378D W 104TH STREET No. 58705 ' HIALEMi.FL3301a �7 I .'.v.'• PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE �T •.• A'Z-•� (V TE F N. VENICE, FL 34276 (941)480-1600'•.F(ORIOL"..••' N ONAL E�G` REGISTRATION#29296 �1III 1 II I I 1 % A LYNN MILLER, P.E. P.E# 68705 TYPICAL ANCHORS TYPE A. B OR C M AT 6' FROM ENDS AND . 9' O.C. INTO WOOD/CONC./METAL 6' O.C. INTO BLOCK ONLY 1-1/2' MIN. WOOD EMBED TYPICAL PAD PILE INSTALLATION LOCATION EALANT EDGE DIST. SEALANT-, 1-1/4' MIN. BLOCK EMBED 1-3/4' MIN. CONC, EMBED 1/B' MIN. METAL THICKNESS EXTERIOR MOUNTED POCKETED JAMB :` X CONC.. / Wool) TYPICAL AT PANEL 4 CORNERS I. L'Ji I. X%Aux% POCKET CAVITY NOT BY CGI NOT PART OF THIS NOA TO BE REVIEWED BY AHJ TNIa: u n "" SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK DETAILS ReW — NO CHANGES THIS SHEET Seriml),fodah I Scala: I Shaeh SGD-150 LMI N.T.S. 23 OF 28 5/22119 R., Dy, Rev. Data: AGK 7/21120 Inaring No. R. SGD15OLMI-NOA A PRODUCT REVISED as comp)yIng with the Florida Bullding Code NOA-No. 20-0729.06 Eacpiretlon Date: 09/2212025 By:_ Isc�g MlamHDade product Control \`��111111'IIil7 ' ®ImpactReslstnnt `��� G'`•,`...1?�•,/�. WIm1= Boors ?�VtCEFIs� CGIDOORs''ANDWiNDaW.%NC. - No. 58705 _ •� 3780 W 104TH STREET _ HULENI, FL83078 s (305) 693 590 '7 PREPARED BY LYNN MILLER �` ! 2I U 1070 TECHNOLOGY DRIVE 0 3 ATE F �z N. VENICE, FL 34275•'•,F:ORIDF•,•'G���� REGISTRATION!/29295 �ONALIEN��� A. LYNN MILLER, P.E. P.E.it 56705 CODS PART No. DESCRIPTION MATERIAL - MANUP.. REMARKS CODE PART No. DESCRIPTION MATERIAL MANUP. REMARKS Ell CGI-183 FRAME SILL 2 TRACK 6083-TB CGI EXTRUDER - M2 CGI-171C- FIXED PANEL CUP (2-1/2- LONG) 6063-T5 - 3 0 FIXED PANEL E2 CGI-151 FRAME JAMB 2 TRACK 6063-TB CGI EXTRUDER - M3 CGI-173 FIXED PANEL SHIM NYLON - .2 PER FIXED PANEL E3 CGI-188 FRAME HEAD 2 TRACK '- 6063-T6 CGI EXTRUDER - Mlo CGI-178 FRAME HEAD ANIUFT &'PAD. PILE WOOL/NYLON SULLIVAN 1 PER INTERLOCK/ASTR. E4 CGI-153 EXTERIOR INTERLOCK 6063-T6 CGI EXTRUDER - M11 W23201NG PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUIV- - E5 CGI-154 INTERIOR INTERLOCK 6063-T6 CGI EXTRUDER - M12 - BOTTOM RAIL STIFFENER, 1- LONG, 2 AT EACH END ALUMINUM CGI EXTRUDER 4 PER BOTTOM RAIL E6 CGI-155 MAIN STILE 6063 TB CGI EXTRUDER - M13 TA-51 ROLLER ASSEMBLY AT PANELS -WITHOUT CORNERS ST/ST AMESBURY 2 PER OPERABLE PANEL E7 CGI-156 TOP & BOTTOM HORIZ 6063-TS CGI EXTRUDER - M13A 1984 ROLLER ASSEMBLY AT CORNER PANELS ST/ST - AMESBURY 2 PER OPERABLE PANEL EB CGI-157 SILL RISER 6063-T6 CGI EXTRUDER - M14 SGD-500 DUAL MORTISE LOCK ST/ST SULLIVAN ATTACHED TO SGD-503 EB.1 CGI-181 ALT. SILL RISER(OPRONAL) 6063-TB CGI EXTRUDER - M14A_ PSOI-0036-117 DUAL MORTISE LOCK ST/ST INTERLOCKS ATTACHED TO Ml SA E9 CGI-158 INTERIOR TRACK ASTRAGAL 6063-TS CGI EXTRUDER - M15 SOD-507 KEEPER ZINC SULLIVAN INST. W/ 2 #IOX3/V PH E10 CGI-159 INTERLOCK REINFORCING (LENGTH FRAME HT. - 87 6003-TB CGI EXTRUDER - MISA SGD-507N KEEPER' ZINC INTERLOCKS INST. W/ 2 01OX3/4- PH Ell CGI-182 FRAME SILL 3 TRACK 6063-TS CGI EXTRUDER - M16 SGD-503 RECESSED ADAPTOR ZINC SULLIVAN INST. W/ 2 01OX3/4" FH E12 CGI-I81 FRAME JAMB 3 TRACK 6063-T6 CGI EXTRUDER - M16A PSO1-0036-117 RECESSED ADAPTOR ZINC INTERLOCKS INST. W/ 2 g1OX3/4' FH E13 CGI-185 FRAME HEAD 3 TRACK 6063-76 CGI EXTRUDER - M17 SGD-5500 HANDLE SET ZINC SUUJVAN/INTERLOCKS - E14 CGI-168 OUTER TRACK ASTRAGAL 6063-T6 CGI EXTRUDER - MIS SM2300WH HANDLE SET OPTIONAL ZINC SULLIVAN - EIS CGI-170 POCKET HOOK 6063 T6 CGI EXTRUDER - M19 SCS2000 SILPRUF SEALANT • SILICONE GE E16 CGI-121 7/16- GLASS GLAZING BEAD 6063-T5 CGI EXTRUDER - M20 CGI-177 PANEL TOP & -BOTTOM DUST PILE WOOL/PVC SULLIVAN OR EQUIV. 4 PER PANEL E17 CGI-123 I- GLASS GLgLNG BEAD 6063 T5 CGI EXTRUDER - M21 WS-202 HEAD AND SILL SMALL PILE .PAD WOOL ULTRAFAB OR EQUIV. 1 PER INTERLOCK/ASTRAGAL EIB CGI-153A EXTERIOR INTERLOCK (OPTIONAL) 6063-T6 CGI EXTRUDER - IA22 WS-201 SILL INTERLOCK PILE PAD WOOL ULTRAFAB OR EQUN, E19 CGI-154A INTERIOR INTERLOCK (OPTIONAL) 6063-TS CGI EXTRUDER - M23 HD-12-10042 .350" REACH POCKET SEAL - - AMESBURY - E20 CGI-155A MAIN STILE. (OPTIONAL) 6063-T6 CGI EXTRUDER - S2 - 010 X 1 1/4- LG. PHL PH. SMS. ST%SL A.SY. SCREW - - 2 OR 3 PER CORNER E21 CGI-156A TOP & BOTTOM HORIZ (OPTIONAL) 6063-TS CGI EXTRUDER - - SINGLE LOCK' FOR ALL PANELS WITHOUT CORNERS ' TWO POINT LOCK BY 'SULLIVAN' OR 'INTERLOCK' LOCATED AT MAIN STILE AT 40" FROM BOTTOM PRODUCT REVISED as complying with the Florida SS MORTISE ZINC RECESSED C ESSEDADAPTOR PART #SGD(503) (PS01 -0036-117) NOA-No 17) Building Code 20-0729.06 ZINC HANDLE SET (PART #SM5500) & (PART #SM2300WH) Expiration Date: 09122/2025 ZINC KEEPER (PART #SGD-507) (PART #SGD-507N) By;_ 15< 7, 1., 44,a' MIamHDade Product Control DOUBLE LOCKS: READ. AT 90' AND 135' CORNER PANELS ONLY TWO POINT LOCKS LOCATED AT MAIN -STILE AT 40" AND 78" FROM ' BOTTOM SS MORTISE LOCKS WITH RECESSED ADAPTORS (PART #HD-3310141) E22 CGI-158A ASTRAGAL (OPTIONAL) 6663-T6 CGI EXTRUDER - E23 CGI-16aA OUTER —TRACK ASTRAGAL (OPTIONAL) 6063—T6 CGI EXTRUDER — E24 CGI-180 DECORATIVE SILL COVER (OPTIONAL) 6063—T6 CGI EXTRUDER — E25 CGI-184 2, 3- & 4 TRACK FRAME SILL SCREW COVER 6063 T6 CGIEXTRUDER— E26 - CGI-187 2, 3 & 4 TRACK FRAME HEAD SCREW COVER 6063-TS CGI EXTRUDER - E27 CGI-188 FRAME JAMB SCREW COVER (OPTIONAL) 6083-T5 CGI EXTRUDER - E28 - CGI-1028 FRAME HEAD 4 TRACK 6063-T6 CGI EXTRUDER - E26 CGI-1029 FRAME SILL 4 TRACK - 6063—T6 CGI EXTRUDER - E30 CGI-1030 FRAME JAMB 4 TRACK 6083-T8 CGI EXTRUDER - E31. CGI-1057 FEMALE CORNER ADAPTOR (9(r) 6063—T6 CGI EXTRUDER — E32 - CGI-1058 FEMALE CORNER ADAPTOR (13T) 6053-TB CGI EXTRUDER - E33 CGI-1059 MALE CORNER ADAPTOR 6063-T6 CGI EXTRUDER - M1 GGI-3132V GLAZING BULB VINYL (DUROMErER 75-80 SHORE A) - - PVC — — BOTTOM LOCK ACTIVATES TOP LOCK WITH A MECHANICALLY ATTACHED CONNECTING BAR (PART #HD-3310142) ZINC HANDLE SET SECURED WITH (2) 6-32 X 1-1/2" OH MS STEEL KEEPER (PART #HD-3310143) SECURED WITH (4) 10-24 X 1/2" PH THREAD FORMING SCREWS SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) I AGK Deecdpu.m Dote: BILL OF MATERIALS 5/22/19 Revlelon: Rev. W. Rev, Data: NO CHANGES THIS SHEET AGK 7/21/20 Sed"/6TadeL• Smle: Sheet: OmwIng No. R. SGD-150 LMI N.T.S. 24 of 28 SGD15OLMI-NOA I A Im actRosistant VAndowaADoors ®W .1`". ,'/A 0Y MSFE0D{- �����OA�{.LYhIN4�''�,i OGI DOORS AND WINDOWS, INC ` .•' 1,1GC-NSF'.��� Q-: 1;n�- 3780 W 1047H STREET HIALEAH, FL 3301E •. z �,{ ;' No. 58705 OWS916590 = /j PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 •. %ni),�[(/` S REGISTRATION#29296 �'ss/ONAL ENG��� /A \ A LYNN MILL�I2I PIE.I I p.6 58705 4.735 .070 .860F .847 1.250 O FRAME HEAD 5.921 m 70 .847 1.250 0 FRAME HEAD 075 .075 . .070 Z.600 .070 2.600 •640I -_.IIL .753 F�-4.735 5.921 Et _ FRAME SILL (2 TRACK) FRAME SILL (3 TRACK) OUTER TRACK ASTRAGAL STILE 0 INTERIOR TRACK ASTRAGAL STILE {�--1.825-1 I I r.125 0 1 E23 OUTER TRACK ASTRAGAL (OPTIONAL) .125-^jf"-• " INTERLOCK �REINFORCING .s2s 1.920 �o © F -.625 SILL COVER(OPTIONAL) EO TOP/BOTTOM HORIZ 3.000 .995 .070 1. 190 1.415 2.005 Es MAIN STILE 3.000 . . .995 .095 1.770 1.415 060 2.005 OE5 INTERIOR INTERLOCK 1.186 995 .060• 1.831 1.501 .156 . 3.000 E4 EXTERIOR INTERLOCK 741 .675 .99T 5 .050 9 5 1.184 GLAZING BEAD LAM. GLASS 1.508� .725 ,065 I .664 125 tat FIX. PANEL CUP .120 .070 1.368 .695 .265 EB SILL RISER �3.188 .070 1.625 .582 2.120 POCKET HOOK ' j�-•.120 .99� I .OSp �9�5 -�I 1.184 F� GLAZING BEAD INSUL LAM. GLASS 1.186 1.50 1 1•O60 1.831 .156 3.000 - EXTERIOR INTERLOCK (OPTIONAL F3 INTERIOR TRACK ASTRAGAL n0e: a�a SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.1.) I AGK EXTRUSIONS U i NO CHANGES THIS SHEET .625 �- Sodas/Yodah - Scala: Sheet: 1 SILL RISER (OPTIONAL) SGD-150 LMI N.T.S.]25 OF 28 TOP/BOTTOM HORIZ (OPTIONAL) 5 2.005 ' ® MAIN STILE (OPTIONAL) �3.000 095 1.770 1601:415 2005 INTERIOR INTERLOCK (OPTIONAL) 5/22/19 Rev. By: Rev. DO.. AGK 7/21120 Otaring No. Rat SGD15OLMI-NOA I A PRODUCT REVISED as eo 1 Ing with the Florida Building Code NOA-No. ' 20-0729.06 Expiration Date: 09/22/2025 By:_ 1 u--7 Miami --Dade Product Control ' 1111111111/// `OlmpulFlo daBt ` Windom & DODB \ N •.• L.1GENgC �C �: CGI DOORS AND WINDOWS, INC. 3780 W 104TH STREET = �y No. 58705 - NML W. FL=18 = n (305) 69M590 PREPARED BY LYNN MILLER �'Jj •: �..' O <�` 1070 TECHNOLOGY DRNE % O ATE OF N. VENICE, FL34275 'i��••,'O(ORIGF;,.•••\'C��� (941)480-1600 % sS �G \� REGISTRATION 02929B ,////,, I .I [ %%X0 A LYNN MILLER. P.E. P.EB 58705 4 FEMALE CORNER ADAPTOR 1 FEMALE CORNER ADAPTOR (135•) F3 MALE CORNER ADAPTOR 0 FRAME JAMB (2- FRAME JAMB (3 TRACK) SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) I AGK EXTRUSIONS 5122/19 ReHalon: Rev. W. Rev. Data. NO CHANGES THIS SHEET AGK 7/21120 Sanee Iodel: Scale: Sheaf• Draw.. Na R.,SGD-150 LMI N.T.S. 26 of 28 SGD160LM1-NOA A 510 I O60 .260 1 �•840 ® FRAME HEAD COVER 640 ® .344 .060 FRAME SILL COVER .243. 1.791 .080 © FRAME JAMB COVER .725 �I .1 25 1.508 .065 .664 F� M2 FIXED PANEL CUP PRODUCT REVISED as eornPWIng with the Florida Bullding ode NOA-No. 20-0729.06 Explratlon Date: 09/2212025 Mlaml-Dade Product Control RosId at O OImpact MMdows III Doors. OCEN��'..{��� reSasnmxaDl- `�,. CM WORSRM WOIDOWB, INC. 376OW104THSIREEr 0 = T;- : No.55705 HUILFN6 Fl.33018 PREPARED BY LYNN MILLER S ••, �11-' 12 0 - 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 S Q • T/iTE OF �"• �'n •. <C/� (941)480.1600 : �n''•��omo..•-'GC�: •iSj/Q�AL REGISTRATION #29296' r 11111I 111\ A. LYNN MILLER, P.E. P.E.*58705 FRAME BOTTOM CORNER 4 TRACK SHOWN 7.750 .080 .925 .857 1..250 FRAME HEAD .oeD � 2.600 .753 E!777:. 330 E29 FRAME SILL (4 TRACK) PRODUCT REVISED as Complying with the Florida Building Code NOA-No. 20-0729.66 Expiration Date: 09/2212025 By: 1 %'--2 1. Mlaml-Dade Product Control SENTINEL 150 ALUM SLIDING.GLASS DOOR (LM.1.) I AGK INSTALLATION DETAILS, EXTRUSIONS 5/22/19 Redefon: R-, Dy: R". Date: NO CHANGES THIS SHEET AGK 7/21120. S.fos/lfod,L• Scale: Sheeh. D—tng No. Rev. SGD-150 LMI N.T.S. 27 OF 28 SGD15OLMI-NOA A FRAME JAMB (4 TRACK) iillllliri OImpact Realstant �.�` O ...... WIOIIOBi dt D00IY `� \"�`� .• _IGEAtg F ` CGI DOORS/WDWOIDOWS. INC. 3730 W 104TH STREPr �\' •`�� �! ;; No. 58705 -_ HIµ.EAKFL33018 (305) 6838590 .. _ �_ PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE ••• 7 .Z. D �r ;• �.0.' N. VENICE, FL 34276 g TE� •, F i'n ' • S C(iW: i ��, (941)480-1600 •. �ORif)N,••'��C1� ,/�IVAL10%.�`�� REGISTRATION#29296 A LYNN MILLER, P.E. P.E.D 58705 %: PANEL TOP/BOTTOM CORNER MITERED BEAD CORNER (TYPICAL) PANEL 10P/B01TOM CORNER SQUARE BEAD CORNER (OPTIONAL) IRS; PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 By, _ 1 �-7, I..i. s Miami -Dade Product Control `�1I1111.171 /r�i ' Drawn By: �1 OImpactRadstent `. �N ,.......... iS DOOR (L.M.I.) AGK Wlndmn & Doors ��. 10CNSF' rreRe:rBollgal^ � @- � � ec p an: Date: CGI DOORS MID NRIDOWS. [NO. : No. 5B705 •� •. INSTALLATIONDETAILS 5/22/18 37B0 W 104TH STREET (as)5934M HIAIPNt,fis901eTTE 7k By. 'Rev. Date: PREPARED BY-Revision:Rev. '1070TECHNOLOGYDRIVE 3 TRACK SHOWN NO- CHANGES THIS SHEET AGK 7/21/20 N. VENICE. FL34275 .' 40RIDP,.•'• i�lss� ••...•. Series/YodaL• S-I... Sheet: Dmring Na Rar. (941)48D-1600 r/1 ONAL REGISTRATION 429296 /111111111 • SGD-150 LMI N.T.S. 28 OF 28 SGD15OLMI-NOA A A LYNN MILLER. P.E. P.E# 58705