HomeMy WebLinkAboutEngineeringLLC 'Lm ineering FLORI DA 4111 Tamiami Trail, Suite 101, Port CharrllotdteEFLg33952 9204 ENGINEERING www.fiengineeringlic.com I Phone: (941) 391-5980 License Number #30782, #60102 KIVlarch 2nd, 2022 lsileo Residence 110680 S Ocean Dr #605 Jensen Beach, FL 34957 mob No.. ! 22060 220 Design Criteria, applicable codes and standards: 1. 2020 FBC (7th Edition), Ch. 16 Structural Design 2. ASCE 7-16: Minimum Design Loads for Buildings and other Structures. Ch. 30 Wind Loads - Components & Cladding General Inputs Ultimate Wind Speed (mph) 175, Exposure Category 0 ' Mean Roof height (ft) 130, Enclosure Type Enclosed Internal Pressure Coefficient (±) 0.18 Roof Pitch (in 12) 0 Minimum bldg dimension (ft) 30 Opening no. Width Height Effective wind area (sq. in) Zone External Pressure Coefficient Internal Pressure Coefficient Design Pressures Positive I Negative (in) (in) Positive Negative (psf) 1 53.00 63.00 23.19 4 0.90 -0.90 0.18 57.87 -64.69 2 1 53.00 1 63.00 23.19 4 1 0.90 -0.90 0.18 57.87 -64.69 3 1 105.75 95.50 70.13 4 1 0.87 -0.88 0.18 56.33 -63.51 4 1 141.75 95.50 94.01 4 1 0.85 1 -0.87 0.18 55.55 -62.92 GU REVIEWED 1=®F;.`"w��®G,��'.CEA! F������r CODE COMPLIANCE r ca�` No. so®z �- ST. LUCIE COUNTY BOCC ` STATE OF ; 9 s ILE COPY CRAIG E. GUNDERSON, P.E. #60102