Loading...
HomeMy WebLinkAboutNOA Single Hung Windowo C6—U DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION 2Z4C;f3 -C NOTICE OF -ACCEPTANCE (NOA) REVIEW MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 CGI Windows and Doors, Inc. CODE COMPLIANCE 3780 W 104" Street Hialeah, FL 33018 fa �-�0�� COUNTY SCOPE: BO.OdoV This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails. to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity. Hurricane Zone. DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,-P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. NUSSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a. permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change. in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. F I LE Ld�120r0722.09 MIAMI•DADE COUNTY Expiration Date: September 22, 2025 W Loyll" Approval Date: September 10, 2020 9/1/20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTEDUNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No.10-0510.11) 2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17,.prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. .CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories,Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test,per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseale and Super . Spacer® insulating glass spacer, preparedby Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) Manuel Perez, P.E. Product Control EC.2 ;1 NOA No. 20 Expiration Date: September Approval Date: September 10, 2020 E - 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series "Sentinel" aluminum single hung window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) C. CALCULATIONS- 1. Anchor verification calculations and structural analysis, complying with FBC 61h Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring'on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP = Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of..Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. Manuel Perez, P.E. Product Control EC72; NOA No. 20Expiration Date: September Approval Date: September 10; 2020 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED)' F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5tn Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation; -signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No.10-0510.11) 3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard'warm-edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, Supervisor. (Submitted under NOA No. 15-0512. 10) G. OTHERS 1. Notice of Acceptance No.15-0512.10, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08'/06/15 and expiring on 09/22/20. ManuelTe Product Control F NOA No. 2a Expiration Date: September Approval Date: September E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW, EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No SH110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)", sheets 1 through 9-of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS. 202-94 2) Uniform Static Air Pressure Test, Loading per FBC,.TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC,. TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested.to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 71 Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. Product Control NOA No. Expiration Date: September'', Approval Date: September 1 E-4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) D: QUALITY ASSURANCE' 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc._ for their "Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No..18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4.' Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017) and the FBC 7th Edition (2020), dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2., Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal. No. 19-1155 TP issued by the Product Control Section, dated January 10,- 2020, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed by Anthony Lynn Miller, P.E. 5.. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 12/21/17 and expiring on 09/22/20.,, <, A Manuel Pe Product. Control E .1 NOA No. 20 Expiration Date: September. Approval Date: September E-5 D.L.O. (FIX. LITE) MAX. A HEAD/SILL ii i II II if II •% II 11 II . %j ====4= II 1� 47 7/16" LARGE & SMALL MISSILE (LM & SM) DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. D.L.O. (FIX. UTE) 20 9/16" ** MAX. Al HEAD/SILL II II It II II 11 •% II �1 II 47 7/16" EQUAL LEG FRAME D.L.O. (FIX. LITE) 20 9/16' ** MAX. 2 HEAD/SILL II 11 II •% II 13 I11 47 7/16" APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIOE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER MIAMI-DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN CENTER ANCHOR REQUIRED WHEN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. SPACING EXCEEDS 20 9/16" THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). LAMINATED GLASS 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED INSULATING LAM. GLASS PRODUCT LOADS TO THE BUILDING STRUCTURE. SMALL MISSILE .IMPACT ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED LARGE MISSILE IMPACT EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METAWC AND NON -COMPRESSIBLE MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL PRODUCT REVISED as complying with the Florida Building code NOA-No. 20-0722.09 REVISED FOR 2020 FBC, ADDED ANCHOR TYPE, BACKBEDDING & REFORMATTED-JR- 07/07120 N y m 0. m aIDQ C lj�0 Z K co Z dON F 3 ' o u�a0 /n o=ae. i' W = W .7 W KU S2 K Wu m z SS S o Ohio Ko>v Z am tL O a2 ES J y Z N G gK !n 1aa45 O W 0 tj W 3 o - z Z R ¢ /n z O H W to Q ogg= ... UnSm W to W W 0) all'1 '�sa0 sauag . ``111111111 /,,I No. 58705 F •••LUG tS A LYNN MILLER, P.E. P.E.# 58705 vmc)z c`" W O N 1 t7 O � yy Ezv D K (il A I/1 � m y..I1 n N Z G)Z C v w HEIGHT g. rn mmy 6 O M S 20 IDDz ii s , N Z.L7 L� L(Til z m m G7 x 0 0 0 o N N D y C. v D HEIGHT C ' D r r c 0 0 FLANGE DIMS. r r • r*R MIN. r �• ITI a 0 En O DIM 'A' X m r BUCK DIM. LENGTH (L) . m ........ m N N m m N m N m m N m N m m N N m u u m u N cei x pd E. r wA N N {'(?' m N m' N In m N m N �•: T � I �� w I N N m m N m m N m m N m m N m m N m C' q pvp{ i i N \ \ t• p z �i m m � V J m m' V m to V J m m V J P m V m c is c o 0 0 o c o o c c is is c o c o 0 0 o v N' N OI N m m C O N m C G m m lJ 0 0 0 m m 0 0 m O m G lJ IT G G UI m lJ O m m G 0 m m •O O m N O G m m G O m G O N O � 00 v� •O oS0000000Soo�oek�e 00000�ggS,S� b 'o 0 o b b c o 0 0 0 0 is o 0 wUmi(JOlJGGOfJ0GCCG G O C C O o G O C G v m • N m. : 3 pp E/ S tl NN m C S • �, f �j p y� N' \\`�; '• Revision: -- \\ Impact Resistant PREPARED BY A. LYNN MILLER 3 •m x 2 ........ 114,, Windows & DOOTS 1070 TECHNOLOGY DRIVE 3 a ao O WERE STRONGER" N. VENICE, FL 34275 m Z g P \� 'yU , - CGI WINDOWS AND DOORS, INC. (941) 480-1600 .30 E C .� • ^ o r _ 3780 W 1 D4TH STREET Z' 2 -O -I O • - HIALEAH, FL 33018 9 d m m m r D m N m• r- REGISTRATION #29296 £ m r. p m (305) 593.8590 o Cn :•y „p-•� o q. Z e N s G +F `" ' •`_ =SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) = 07/02120 m 6 co DESIGN LOADS pm' JENS ROSOWSKI N N 111111111111�IN��`\ SH110"SENTINEL"� 20F9 oz SH110-LM-NOA A N m .075' Saflex CP With PET Core .075" Saflex CP With PET Care • By 'Eastman Chemical Co: By 'Eastman Chemical Co.' .090" Saflex Clear And Color Glass iQ .090" Saflex Clear And Color Glass _ g - By 'Eastman Chemical Co.' g By 'Eastman Chemical Co.' o: .090" SenlryGIas0 " By 'Kuroroy America, Inc.' '090" SentryGlas® By 'Kuraray America, Inc.' PRODUCT REVISED1 _ 0" Trosifol PVB 1/B" ANNEAL'Kuraray Amefco, Inc.' 1/8' HEAT STREN'D GLASS .090' Trosifol PVB By 'Kutcray Amefca, Inc.' as ,d, Plying with the Florida Buildln9 Code. NOA-No. 20-0722.09 Ex Iratlon Date• 9/22/2025 ANNEALED GLASS 1/8' HEAT SMEN'D GLASS ' �VY>uGfnC SI I .ON . SILICONE, By: J Mlam pade Product'Co trol • 4G—L--J/BD1' GE 1200 DOW CORNING 791, 899, 9B3 & 995 m GE 1200 DOW CORNING 791, 899, 983 & 995 ADDED BACKBEDDING 'TYPES M1 I: - JR - 07/07/200 ([' ESN 1 iC >j nay WWW GLASS TYPE 'A' W GLASS TYPE '13' o O ' 5/16' OVERALL LAM. GLASS 5/16OVERALL LAM. GLASS asap O �• (L.M.I & S.M.I.) (L.M.I & S.M.I.) z C 0 z z o � z N ao d ' m u.eojp M j Q Z m T wxuT" w 0 z9 ' .075" Saflex CP With PEr Coro .075" Saflex CP With PET Core ¢ Z v 7 'aN 9M0 By 'Eastman 'Chemical Co: By 'Eastman Chemical Co.' a w .. K a �' CD _ S"'0" Saflex Clear .And Color Glass _ • 1/8" ANNEALED GLASS .090" Saflex Clear And Color Glass 1/8" HEAT STREN'DJD a . i By 'Eastman Chemical Co.' 'Eastman Chemical Ca:LL .Z,. ? 1/4" AIR SPACE. o:.090" SentryGlas® 1/4' AIR 0" SentryGlasV Amadca, Inc." 'Kuroray Ameriea; Inc.' wO U c�tz 1/8" ANNEALED By'Kuraroy .090' Trosifol PVB 1/8" HEAT ST0' Tmeifol FVB e y G ¢ rn IaaVS OR TEMPERED• GLASS By 'Kuraray Amerce, Inc.' OR TEMPERED• G 'Kuraray Amerca, Inc.' off $w " Z1/8" ANNEALED GLASS HFAT STREN'DGLASS¢d'.E -SILICONE: $r�N p o u_'4 N OSILICONE: ro GE 1200 CORNING 791, i GE 1200 DOW CORNING 791,3 Z = W rn m,OW M7 899, 983 & 995899, 983 & 995 ¢ o UPS"' u C0 [s \ XL EDGE SPACER XL EDGE SPACER SIT.. STEEL BY 'CARDINAL' STT.. STEEL BY 'CARDINAL'LYNN'%ODURASEAL BY 'QUANIX' DURASFAL BY 'QUANIX' /OR ORMSUPER �` SPACER BY 'QUAND(' SUPER SPACER BY 'QUANIX' Q..; •• �. 'Al' 'Hi' J No. 58705 '•: * _. GLASS TYPE GLASS TYPE 0.70' OVERALL INSUL LAM. GLASS 0.70" OVERALL INSUL LAM. GLASS =-D• 16 (LM,I & S.M.I.) (L.M.I & S.M.I.) -�0: ST TE F !(y` SOT•.• 'ON AL A LIMN MILLL}t, P.E • FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. P.EII 58705 WOOD B7 FOR S ••. I d ^ae rtOGF�OISF.: : ,,d �aC.n•`. e..a ad1 SWEEP -LOCK OPTIONAL TO EGRESS LOCK AT SILL u EDGE • DIST. TYPICAL AN(; ' 1BY I SEE MXV/ TYPICAL ANCHORS SEE ELEV. FOR SPACING 9 2 3/8- MIN. 2 3/I I WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 246". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WOW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. • • a . a EDGE DIST. * .. • a •.. , j TYPICAL ANCHORS a SEE ELEV. FOR SPACING \ MIAMI-DADE COUNTY APPROVED I I MULLIONN do MULLION ANCHORS ,� II SEE SEPARATE NOA I �y,_EOGE TYPICAL ANCHORS \_TYPICAL ANCHORS -SEE ELEV. SEE ELEV. FOR SPACING FOR SPACING 7YPICAL ANCHORS: SEE ELEV. FOR SPACING 1 /4" DIA..TAPCON BY 'ITW' (FU-125 KSI, Fy=100 KSI) 1/4" DIA. ULTRACON BY 'ELCO' (Fu-177 KSI, Fy=155 KSI) 1/4" DIA. ULTRACON+ BY 'DEWA T'(FU=164 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD ' THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) #14 SMS OR SELE DRILLING SCREW S (Fu-74 KSI, Fy=57 KSI) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6053-T5 MIN. STEEL ; 1/8" THK. MIN: (Fy = 36 KSI MIN.)' (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOO- AT HEAD, SILL OR JAMBS SG=0.55 MIN. CONCR • AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 H04LOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. PRODUCT REVISED as complying with the Florida Bullding Code NOA-No. 20-0722.09 ADDED ANCHOR TYPE - JR - 07/07/20 rc a .Q o n � •nab - � m d rn zo: o alo0 O N O zo z dUl oN v z z �IUWGUd w 2 u adz j _ m LL y U J O z ! uj 0 (7 co v ;-is o61c� g� c zm JQ w Z Ell <w � c, W w o O0 LU Un�n w O LL fn �a81 rosa0 sauag \\�1111111 //ll, LYN/v No. 58705 '//11111151�` A LYNN MILLER, RE P.E# 58705 og � O I Aq m m v yy z.N • 'd n 11 ; �mo G Y•d = i O N r______ - ___ �1 � o� I I mm 3:''O j N ZOO m _ C N - 0 M0 N I y. N m xN V , Q O� O .$ I to r :' � •' ...a I � Qai i5c 111 . a o a. Lac m iN m z a D C o D r O EXTERIO R D O a-0z moo a o N -- -- o.m 0_— III_ y0 M z L H O m En 1/2. M, 1/2• TYP II . I Impact Resistant Revisfan' PREPARED BY A. LYNN MILLER '3 ,t ��� ` Windows & Doors 1WOTECHNOLOGY DRNE m •• G —° .� � ..... ••.'9iyJ, �� VIM SIADRGER" N. VENICE, FL 34275 3 a z 5'3 O A o ,• , y CGI WINDOWS AND DOORS, INC. (941) 460-1600 ii o ma C v i �� �) '•,� 3780W 104TH STREET o e C) I° HIALEAH, FL 33018 REGISTRATION #29296 � 3_ z; 0 n _ (305) 593-6590 0' A f M D :� m� �� cNi _ a N m •r „� o �y `� SERIES 110 ALUM. SINGLE HUNG WINDOW.(LM) 0 07/02l20 c N I" �hA c FLANGE DETAILS 2 JENS ROSOWSKI ° N N e O SH110 "SENTINEL" N 5 OF 9 o z° SH110-LM-NOA A N m m TYPICAL ANCHORS SEE ELEV. 1BY FOR SPACING WOOD BUCK •i4 � a iA� s Al M3 E1 EQUAL LEG FRAME I. PRODUCT REVISED as comp)y.T with the Florida Bulldln6 Code NOA-No. 20-0722.09 & MULU N ANCHORS �. o Ij Ms 1/4' MAX SEE SEPARATE NOA BUCK WIDTH BUCK WIDTH - 4 SHIMS BUCK WIDTH c :. D1 SWEEP LOCKY 1 OPnONAL TO ' I I cJ EGRESS LOCK o a AT SILL - — — • a ua� 0 0 61aO 0 Of N Z B EDGE M3 0. I I J 0 OZ z UJI E4 DIST. e ° , '• �IL _ _J ¢. o d 0 0 [Jcl ",Q co ❑ = W 1� i 1 m v E3 EB #14 X1� FH. SMS. C4 a C.)m Z ! W Z OMO i (L z rn i W li z EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY a v; J 1 a• INTO WOOD. CONCRETE OR METAL STRUCTURES y ac seas 0 1 WITHOUT THE NEED OF A WOOD BUCK. 3 o LU E ^ s � � ¢ z W 2 3/8' MIN. - vl _ �¢ yar W ®zW a! aS4' 2<z o 1 1 EB "���- \� M a111 'asap seueg 2 3/8- MIN. + d Ms . :. c p q . , { LYNAt OC1 I 14 =Y t ° •'7` ' $ SEE E�LEVANCHoes �2 • L1cer,s, �` .�•. I FOR SPACING �_: '•.'P E2 ��` �, _ No. 58705 WHEN USED THE MIN. WOOD BUCK, i !6 zD w� DEPTH SHALL BE 2%'. THE USE OF % Q 6 ,E r ;: 'I a> DEEPER OR BEVELED WOODBUCKS IS ST FCO. •R. 1•LDP ' .`\D^ APERMITTED.SEE 1BY FOR SPACING 'r7�1 NAi1i1\` WOOD BUCK A. LYNN MILLER, P.E. P.E.N 58705 Olm act Resistant Revision: P PREPARED BY A LYNN MILLER 3 to Z MID 'p 1 I I I 1 �7ji� w Windows & Doors 1070 TECHNOLOGY DRIVE d C .� WERE STRONGER" N. VENICE, FL 34275 3 � Z 33 O > ` G)�,•' ••' • MT. % CGI WINDOM AND DOORS, INC. (941) 480-1600 b ; o C v i ` `Cj : :yam �� 3780 W 104TH STREET �.. O z TJ — • -z .HIALEAH, FL 33016 m m In "' V 'REGISTRATION #29296 9 m a _ ,Z ; O D ,o` _ (305) 593-6590 i 1 _ 6 Tit o _ f ,o O y : t ` = SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) 0 07=120 To O S to •' " cJ ''. �_ ; N m in FIN DETAILS' o m JENS ROSOWSKI SH110 "SENTINEL" 7 OF 9 oz° SH110-LM-NOA' , A tNi1 to 0 m !zi m W D G) O '� Lp9 m� D ONi O W N C m� (� () n O O O D D A 0 m 0 0 o 0 0 o 0 1 1 I 1 T.m l T I I D I 1� 1 I p l � j u 1, I T T T T I I �_ � T T ��� I � I � �� T � T �� 7! N O y O yy yy yy yy O 0 0 0 v D o E E 5 v f��Il O o F D v v e `'e S O v p E O A 0 0 P Bass x A • 2 m Fe ,'F ,`s •`c p F5 D O O O O O VQ i+ m f F� O mx m �F :0Oe$01 N9'gpn c W a n� Vl oOO —m fSr v Jrs C X X X W L C I' � Fw ¢ m Z .NF_S p OI i i i y�o z 4� O RRAII m S W_ mC WE; m O N P F e2e m m s c� Z O m M 3 O i [7 15 i A r W N 0 n m Y z O sm0{ W m D D W y z W n I I I 1 'Z v i c O I .'I fJ O m m m w w m 0 m°D' w w m g m w w 0 m �m u w m m rn m w ww mmm m o u g o m w ww 'ii 6', m Y O Z A O Z Z O Z; 11 1 1 1 1 1 m m 1 1 m m 11 m m 1 m I I I A? O N W R.r o r C v,� o Oy r r r a 2 � C 3� c N 00 y 1 A O 0 C 9 m ' ; O III Z 2=� � \ m 0 C m m O O C C m Ow D O W D Z m C m' C O z S F O • D — — — — iJ �8cl ��/// OImpact Resistant Windows & Doors PREPARED BY A LYNN MILLER 1070 TECHNOLOGY DRIVE Revision: 3 W ii = an xv J'i� •,...... ..,ti WM SMONGER" N. VENICE, FL 34275 3 — a o O INC. (941) 480-1600 �� 1O9 .� fl •:,� Z •,2 ' CGI WINDOWS AND DOORS, 3780 W 104TH STREET o ° C gin p Z`n:- m 2: HIALEAH, FL 33018 (305) 593-6590 REGISTRATION #29296 e A £A SERIES 110 ALUM. SINGLE HUNG WINDOW (LM) 0 07/02/20 ° Ip o ' o BILL OF MATERIALS om JENSROSOWSKI m .•" '^` O N N o0 ° N Nf O a to a m SH110 "SENTINEL" _ r $ OF 9 sd Dz SH110-LM-NOA a . A zsos zsos .OBS S2 S2 11550 L_LL..j5 .ett ,81,880 .745 O6 1.245 ' .745 OBS 1YP. if 1.015 1.015 1.395.. .0 PRODUCT REVISED as complying with the Florida E72 FLANGE FRAME HEAD E7 FLUSH FRAME HEAD E71 NAIL FIN ADAPTER Building NOMNo.Code 20-0722.09 1.583� 1.50 - 1.007 - Ex iratlon Date• 9/2� 212025 By: .. ,745 Mlam pade Produc;YCc trot O65 065I TIP- TYP• 2.113 hm-1- 3.175 1.366 ,o 3.s75 1.429 1 429 3.175 1.015 . VENT TOP CORNER - rc .065 1.220: 1.000 .500 O N Y Q IFsoo 2.s0s E4 MEETING RAIL FRAME TOP CORNER 0 "aa 2.505 - o N 1.220 _ � N ai°0 W 0 Eta FLANGE FRAME SILL O FLUSH FRAME SILL i o z z .50D 1.301 �1.301 1.043 [ I %9 d O A ~ `J: I R O I 1.788 m p li p X9 = L z m 0 uMn N 055 S2 w v m W Z F.065 065 .065 065 7YP. _ .Q .°N TYP. _ TYP. W O ,^_ C0 9M0 1.015 6.. � i O_ M 2.440 2440 LL 1.015 1.0t5 O LOCK RAIL I �, z FRAME BOTTOM CORNER o `o VENT BOTTOM CORNER 3 c c 6 K hays 0 2.195 � . .745 .745 3 a S w - z 2.048 2.348 (� ((����nn a In i= . O W E13 FLANGE FRAME JAMB O FLUSH FRAME JAMB I�-t-n-1-'II L.SvLJ 1.892 g W O o . d'.075 oss 1Ii �S2 �z .120 U on�1=YIcn NaW 705 TYP, .705 050 .asoa1.043. TYPLYWUpNJt �'ro's�a0 sa2!uAa .1364 5 HAND RAIL O5/16- GLAZING BEAD O .700" GLAZING BEAD No.56705 II 1.395 1.4aa .741.450.160 �� ••' �. �.� �, 293 .675 ! �s F<ORIDP,.•'• \C� .050 .06�7 .060 �- sso 1.413 rr�111111111\\ u3 A LY FLUSH FRAME COVER 19 SCREW COVER O SASH RAIL E10 FLANGE ADAPTOR P.E# 5 T05 P E