Loading...
HomeMy WebLinkAboutNOA Sliding Glass Doorocltu� ml"-_'�,-___��'�-_'3 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CGI WINDOWS and DOORS, INC. 3780 W. 104" Street Hialeah, FL 33018 SCOPE: 2Zo 3 —os7�' REVIONED FOR MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economy This NOA is being issued under the applicable rulef%jarl�g of construction materials. The documentation submitted has been reviewed and accepted by rig SS ty R -Product Control Section to be used in Miami Dade County and other areas where allowed b�Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ. may immediately revoke, modify, or suspend the use of such product or material. within their. jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and. has been designed to comply with the Florida Building Code, including the. High Velocity Hurricane Zone. ' DESCRIPTION: Series "Sentinel 150" Aluminum :Sliding Glass Door w/ wo Reinforcements'— L.M.I. APPROVAL DOCUMENT: Drawing No. SGD150LMI-NOA Rev A (former SGD150LMI-NOA Rev O), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by manufacturer, dated 07/21/20, signed and sealed by Lyn Miller, P. E., bearing the Miami —Dade County Product Control Revision stamp with the Notice of Acceptance number and Revision date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. Pocket wall is not part of this approval and to be reviewed by AHJ. 2. See Design Pressure (DP) table: Sizes Vs glass types, Interlock reinforcing & sill riser and the max allowable panels for the entire unit, in sheet 13. See anchor clusters DP capacity in sheet 15. Lower capacity shall control for the entire assembly. For Doors w/ corners, see limitation note 4, below. 3. Max shim not to exceed'/2" at Head/jambs &'/z" at Sill (w/ High strength poured & hardened grout). The Sill to be installed w/ anchor type B-2, directly into cone. 4. Units containing 90' & 135' exterior corners must be limited to Max Dp= +/-60 PSF. See sheet 22 for anchor layout. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 19-0603.03 and consists of this page 1 and evidence pages E-1, E-2, E-3 & E-4, E-5 and E-6, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. FILE 46%,P 2Y0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 Page 1 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous approvals - A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. W10-31 Rev L, titled Series "Sentinel 150 Alum Sliding Glass Door", sheets 1 through 28. of 28, prepared by Al—Farooq Corporation, dated 05/20/10 and last revised on 01/11/16, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 . 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC, TAS 202-94 along with marked —up drawings and installation diagram of 8-panel, Alum SGD w/ Pockets & 1350 and 90' corners, prepared by Architectural Testing, Inc., Test Report No. D8502.01-450-18, dated 12/07/15 respectively, both signed and sealed by Joseph A. Reed, P.E.(submitted under file #15- 0619.06) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2..1, TAS 202-94 along with marked —up drawings and installation diagram of 6-panels Alum SGD w/ Pockets & 0XXX, prepared by Certified Testing Laboratories, Test Report No. CTLA-3011-W & -W-1, dated May 22 & 23, 2014 respectively, both signed and sealed by Ramesh Patel, P. E. (Note this test reports have been revised by an addendum letter dated. SEP 245 2014, issued by Certified Testing lab.) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 - 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of 'a series 7500FW Vinyl Flange -Frame Impact Fixed Window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer& insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WA dated 03/03/15, signed and sealed by Ramesh Patel, P. E. along with marked —up drawings and installation diagram of a series 7400PO Vinyl Impact Flange Frame Project Out Windows, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WB dated 03/03/15, signed and sealed by Ramesh Patel, P. E. along with marked —up drawings and installation diagram of a series 238 Aluminum Fixed Flange Frame Window with Vent to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Testing Laboratories, Test Report No. CTLA-3056 WC dated 04/16/15 and revised on 03/09/16, signed & sealed by Ramesh Patel, P. E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September. 10, 2020 E-1 r CGI WINDOWS AND DOORS, INC., NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (continue) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC; TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 12.1, TAS 202-94 along with marked —up drawings and installation diagram of Alum SGD, prepared by Hurricane test Laboratory, LLC, Test Report No. HTL4080-1208-090, dated July 30, 2010, signed and sealed by,Vinu J. Abraham, P. E. (submitted under files #12-0119.04/11-103.1.05) along with marked —up drawings and installation diagram of Alum. SGD (OX) prepared by Architectural Testing, Inc., Test Report No. ATI—00733.03-450-18, dated 08/09/12, signed and sealed by Vinu J. Abraham, P. E. (submitted under files #13-1121.08 /#12-0821.16). C. CALCULATIONS 1. Anchor verification calculations and structural analysis, conformance to, complying with FBC- 2010 and with FBC 5111 Edition (2014), prepared by Al—Farooq Corporation, dated 02/24/16, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300- 09. D. QUALITY ASSURANCE 1. ,Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "Sentry Glas® (Clear and White) Glass Interlayers", expiring on 07/04/18. 2. Notice of Acceptance No. 14-0423.15 issued Eastman Chemical Company (MA) for their "Saflex CP-Saflex and Saflex HP Composites Interlayer w/ PET core", expiring on 2/11/18. 3. Notice of Acceptance No. 15-1201.11. issued Eastman Chemical Company (MA) "Saflex Clear and colored glass interlayer", expiring on 05/21/2l. 4. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their `Butacite® PVB.Glass Interlayer", expiring 12/11/16. F. STATEMENTS 1. Statement letter of conformance to, complying with FBC 5th Edition (2014),, and of no financial interest, dated 02/24/16, signed and sealed by Javad Ahmad, P. E. 2. Addendum letter dated SEP 24, 2014, issued by. Certified Testing lab, signed and sealed by Ramesh Patel, P. E. 3. Lab Compliance statement, part of above referenced test report. t s (. Z..4q Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-2 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G. OTHER 1. This NOA revises NOA # 15-0619.06, expiring on Sep. 22,,2020. .2. Test proposal for the qualification of Butacite® PVB glass interlayer by Kuraray America, Inc., as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.E. 3. Test proposal # 14-0198, approved on 02/26/2014, signed by Ishaq I. Chanda, P.E. 4. Test proposals # 13-1098, approved on Oct 02, 2013 and revised on FEB 24, 2014, signed by Manuel Perez, P.E., test proposal # 11-1225 dated DEC 16, 2011 signed by Jaime D. Gascon, P.E. Test proposal # 09-1073, approved on Nov. 05, 2009 and E-mail test proposal dated 07-19- 2010, approved by BCCO. 2. Evidence submitted under previous approval. A. DRAWINGS 1. Drawing No. W10-31 Rev O, titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by Al—Farooq Corporation, dated 05/20/10 and last revised on MAR 05, 2018, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Letter of conformance to FBC 2017 (61h edition) and No Financial interest, prepared by Al— Farooq Corporation, dated 09/1447, signed and sealed by Javad Ahmad, P. E. G. OTHER 1. This NOA revises NOA # 17-1011.18, expiring 09/22/2020. - 3. Evidence submitted under previous approval A. DRAWINGS- 1. Drawing No. SGD15OLMI-NOA Rev O (former W10-31 Rev O), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by manufacturer, dated 05/22/19, signed and sealed on 05/23/19 by Lyn Miller, P. E. (Note: This revision consists of Successor Engineer adopting another Engineer work as his own and addition of Dow 983 silicone) Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 'Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-3 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. REF Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2), Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings of an aluminum SGD, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL 19-936, dated 04/15/19, signed and sealed by Idalmis Ortega, P. E. C. CALCULATIONS (submitted under file # 17-1011.18) 1. None. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. 'Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. (former E.I. DuPont DE Nemours & Co., Inc.) for their "Sentry Glas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 2. Notice of Acceptance No. 18-0103.01 issued Eastman Chemical Company (MA) .(Former Solutia Inc.) for their "Saflex. CP-Saflex and Saflex HP Composites Interlayer w/ PET core", expiring on 12/11/23. 3. Notice of Acceptance No. 15-1201.11 issued Eastman Chemical Company (MA) (Former Solutia Inc.) "Saflex Clear and colored glass interlayer", expiring on 05/21/21. 4. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. (former E.I. DuPont De Nemours & Co., Inc.) for their "Trofosil® Ultra Clear, clear & color PVB Glass Interlayer", expiring 07/08/24. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 61h Edition (2017), dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. 2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E. 3. Test Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019, - signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15- 27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed by A. Lynn Miller, P.E. G. OTHER 1. This NOA revises NOA # 17-1218.20, expiring 09/22/2020. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-4 CGI WINDOWS and DOORS, INC. NOTICE OF ACCEPTANCE:- EVIDENCE SUBMITTED 5. New Evidence submitted A. DRAWINGS 1. Drawing No;-SGD150LMI-NOA Rev A (former SGD15OLNU-NOA Rev O), titled Series "150 Sentinel Aluminum Sliding Glass Door", sheets 1 through 28 of 28, prepared by manufacturer, dated 07/21/20, signed and sealed by Lyn Miller, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test 'per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all CGI Windows and Doors, Inc. and PGT Industries, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared. by Fenestration Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20=2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed -by Idalmis Ortega, P.E. PGT Industries, Inc. test specimens: FTL-1897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20=2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740. Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT* PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and. sealed by Idalmis. Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 7" Edition (2020)., dated 07/20/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-04, -09, -12 and -16. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E - 5 CGI WINDOWS and DOORS, INC.. NOTICE OF ACCEPTANCE:. EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 2. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) (former Solutia, Inc.) for their "Saflex CP- Saflex and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/2023. 3. Notice of Acceptance No. 15-1201.11Issued Eastman Chemical Company.(MA) (Former Solutia Inc.) "Saflex Clear and colored glass interlayer", expiring on 05/2.1/21. 4. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. (former E.I. DuPont De Nemours & Co., Inc.) for their "Trofosil® Ultra Clear, clear & color PVB Glass Interlayer", expiring 07/08/24 F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 07/20/20, prepared, signed & sealed by Lynn Miller, P. E. 2. Statement of Lab compliance as part of the test report. G. OTHER 1. This NOA revises & renews NOA #19-0603.03, for FBC 2020 update, expiring 09/22/25. 2. 1 RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E. Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0729.06 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E - 6. "SENTINEL" SERIES SGD150A ALUMINUM SLIDING GLASS DOOR DOORS ALLOWED FOR,MAX. NUMBER OF PANELS AS LISTED ON DESIGN LOAD CAPACITY CHART ON SHEET 13 OF 28. USING MEETING STILE COMBINATIONS TESTED AND SHOWN IN DRAWING DETAILS. APPLICABLE EGRESS REQUIREMENTS PER FBC TO BE REVIEWED BY BUILDING OFFICIAL THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDMON)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUrS INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A. LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALUC AND NON —COMPRESSIBLE._ MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND ' SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY. AND TO BE REVIEWED BY BUILDING OFFICIAL INSTRUCTIONS: USE CHARTS AS FOLLOWS. STEP 1 DETERMINE DESIGN WIND LOAD REQUIREMENT BASED ON WIND VELOCITY. BLDG. HEIGHT, WIND ZONE USING APPLICABLE ASCE 7 STANDARD. STEP 2 DETERMINE DOOR CAPACITY FROM TABLES ON SHEET 13 fuK THE GLASS TYPE AND REINFORCING TO USE. STEP 3 USING CHARTS ON SHEET 15 SELECT ANCHOR OPTION WITH DESIGN, RATING MORE THAN DESIGN LOAD SPECIFlED IN -STEP 1 ABOVE ' STEP 4 THE LOWEST VALUE RESULTING FROM STEPS 2 AND 3 SHALL APPLY TO ENTIRE SYSTEM. THESE DOORS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED as Complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 Mlaml-Dade Product Control SENTINEL 150 ALUM SLIDING GLASS DOOR (LMI) AGK Description: Data: COVER, INSTRUCTIONS 5122/19 Redslan: Rev. Bj, R.Y. Date: UPDATED TO FBC 2020, ADDED ANCHORS & BACK. AGK 1/21/20 Sedes/Model: Smle: Sheet: Dr w.Mg No. Rev: SGD-150 LMI NTS 1 OF 28 SGD15OLMI-NOA A LAMINATED GLASS.AND LAMINATED INSULATING GLASS LARGE/SMALL MISSILE IMPACT • Illlll llll// OImpactResweril WIII110N(t & BDDrs'��.•'•OGENSE'• ��� O�Y. Y . umectmwxeDl� �. '•.� CGI DOORS AND WPIDOWS, INC. 3780 W 104TH STRFEr HUIFAH.FL33018 No. 58705 ` •: (305)693-8.590 �I. 7�t _ u — Of �0 ••.: �[/ PREPARED BY LYNN MILLER 107Q TECHNOLOGY DRIVE N. VENICE, FL34275 A-� ` • (941)480-1600 '� • F4, • \�� CcS''• •.O_••RID.." `G? /S /0NAL1�,`��\ REGISTRATION#20296 A LYNN MILLER, P.E. P.E.# 58705 6' 3' (B) ANCHORS MT,P CLUSTER SHOWN 14- 1 3 TRACK HEAD ANCHORS - - 282 13/16` MAX. M - _ DOOR FRAMEWIDTH HEAD ANCHORS 14' MAX. 48 1/a• ANCHORS IN PAIRS 2, 3 OR 4 PAIRS HEAD/SILL AT HEAD/SILL/JAMBS AT STILE ENDS SEE SHEET 15 NOM. PANEL WIDTH _ AT 3' D.C. 6' MAX. - 1 13/16' FALSE MUNTIN SEE CHART ON SHEET 15 HEAD/SILL OPTIONAL A C E F` CAPACITY CORNERS io I 3 TRACK JAMB ANCHORS 2 POINT SINGLE LOCK .L OP � � � oo• i. - SEE SHEET 24 o FOR DESCRIPTION JI it a II_ a a II II y�QU B D � REINFORCING AT INTERLOCKS OPTIONAL ' SEE SHEET 13 FOR CAPACITY M 42 1/8• - D.L. OPG. %/. /ZIX PRODUCT REVISED as camp)yIng with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 By:_ era•-7 r. Eb, _:. I. MiamhDade Product Control z I \ z 0 m O 3 a� - , o� z�l Ym �o I POCKET J B r-q, ' SILL TYPE B2 ANCHORS 2, 3 OR 4 PAIRS AT STILE ENDS INTO CONC. AT 3' O.C. SEE CHART ON SHEET 48 1 a` PANEL WIDTH 48 1/8• (SEE SHEET 6, H, 11 & 12 & DETAIL M ON 1 POCKET ' CLUSTER SHOWN 15 FOR CAPACITY PANEL WIDTH. SH 3) JAMB ANCHORS • - . - . • .• (SEE SHEET 23 FOR • TYP. INSTALLATION) = fi• 14` MAX• 3 TRACK .. -. m TY LL ANCHORS - I (1) WEEP CLUs7a (2) WEEP CWSIER (2) WEEP CWSIER (2) WEEP CLUM 2 WEEP C1DSIER 2 WEEP CLUSTER (1) WEEP CLUSTER ;\1111`I,I vl^I Title: Omwn By: ImpaDlRaalstaM ♦ .... i � .��• ••"cEN •. �l�C '� SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Windows & Doors P; weResmoxcm- � ••.� APICAL ELATION ssWp on: Date: CGIDOORS AND WINDOWS.INC. = 'x i NO.58705 '; TESTED UNIT - 5122/19 HLAL W i. FL STRFFf t305)M,R930tS = ELEVATION (�sasas� ' - Rav7oion: Rev. BY•' Ray. Gate: PREPARED BY LYNN MILLER 1070 TECHNOLOGY •• ` Zn �Q '•• qTE F <� '•. D.L. OPENING D.LO HEIGHT = DOOR FRAME HEIGHT — 9 11/16' NO CHANGES THIS SHEET AGK 7/21/20 DRIVE N. VENICE, FL 34275. (941) 480-1600 T •' U� i �<` '•.'D(0 1pP •-•' ��` ��/ss'/ ..... • • •��G D.L.O. WIDTH — NOM. PANEL WIDTH — 6• Selo/Model: - Swle: sheet:. Dmwiaa N. 7!/t/t AL1111_�` PANEL HEIGHT = DOOR FRAME HEIGHT —1 3/16• REGISTRATION#29296 - SGD-150 LMI N.T.S. 2 OF 28 SGD15OLMI-NOA JRev: A A LYNN MILLER,P.E. P.E.#58705 6" 3" (B) ANCHORS .... CLUSTER SHOWN IYP. 2 TRACK HEAD ANCHORS . 1 1: �z TRACK JAMB ANCHORS N U (TESTED UNIT) 144 TYPICAL ELATION (1i+ta0lsrt REFER TO PAGES 14, 15, 17 & 18 FOR WEEP SIZE. 18" 42 1/8" IPG. D.L. OPG. 0 � o oI 3 o� z� I PRODUCT REVISED m as complying with the Florida Building Code a I NOA-No. 20-0729.06 J LU Expiration Date: 09/22/2025 8. 1 Miami -Dade Product Control WIDTH 48 1/8" POCKET PANEL WIDTH 2 TRACK JAMB ANCHORS SILL ANCHORS ' D.L. OPENING D.LO HEIGHT = DOOR FRAME HEIGHT — 9 11/16" C.L.O. WIDTH — NOM. PANEL WIDTH — 6" PANEL HEIGHT DOOR FRAME HEIGHT —1 3/16" (t) em a9s0a (q � melm . ``11uulirrrr7j, true: Dmrn By., Resurrect SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK OImpact VAndows CGIDOORSANDWINDOW8, INC. _ No.58705 Deserip ion: Oate; 3790 W 1041H STREET HLU.EAH,FL33018 — ELEVATION 5/22/19 (3M693-9590 Rev. Dote: PREPARED BY LYNN MILLER �` ��O •'.� t(/ Revision: W. Rev. 1070 TECHNOLOGY DRIVE E •. ''•. NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL 34275 '��(� RC ORION i ( 941)480-1600 s / "-•••-" �j\ �/`/ ANAL 7 rt Sarras/6fodel: S-I.. Sheet:, - Dmlrin9 N .- Rev: SGD-150 LMI N.T.S: 3 • OF 28 SGD15OLMI-NOA A REGISTRATION 029206 1 11 1 1 , %111 A. LYNN MILLER, P.E. P:E#58705 (8) ANCHORS (8) ANCHORS CLUSTER SHOWN 6. 3" .... .... .... - ... CLUSTER SHOWN, TYP (SEE SHEET 22) 14" EXTERIOR E)TERIOR 3 TRACK HEAD ANCHORS - "� MAX 149 5/16" 146 9/16- 97 3/4' M° nnno Coeur wniu I DOOR FRAME WIDTH • DOOR FRAME WIDTH FALSE MUNTIN OPTIONAL io JI �0I U U I\ O o m g Z 2 iD . LL< 0�i W la z� �m a� 49 WIDTH ANCHORS IN PAIRS AT HEAD/SILL/JAMBS. M II H H 0 — 2 1/8 — o ca �i �I I� cq N • II II tao HEAD ANCHORS 14 MAX. 2, 3 OR 4 PAIRS HEAD/SILL AT_SRLE ENDS SEE SHEET 1 AT 3' O.C. SEE CHART ON SHEET 15 FOR CAPACITY HEAD ANCHORS 2 OR 4 PAIRS ///---AT CORNER STILE ENDS SEE CHART ON SHEET 15 1 / FOR CAPACITY REINFORCING AT INTERLOCKS OPTIONAL SEE SHEET 13 •. H a FOR CAPACITY P 2 POINT DOUBLE LOC S SEE SHEET 2 FOR 42 1/8- DESCRIPTION 2 POINT - DOUBLE LOCKS D.L. OPG. i. _ i. �• SEE SHEET 24 / i% / M FOR DESCRIPTION N O gad 2 42 CORNERS L_ .� 1 1 POCKET OR SILL TYPE B2 ANCHORS SILL TYPE B2 ANCHORS 2, 3 OR 4 PAIRS 48 1/B• 4R 1/8' 48 1/8" N 1WID PANEL WIDTH iq M 0 PANEL WIDTH JAMB ANCHORS 2 OR 4 AT STILE ENDS PANEL WIDTH PANEL WIDTH 3 TRACK AT CORNER STILE ENDS. SEE CHART ON SHEET 15 AT 3' O.C. JAMB ANCHORS .. FOR CAPACITY SEE CHART ON SHEET 15 - - - FOR CAPACITY io 6' 14' 3" (4) ANCHORS DRERIOR (6) ANCHORS__ ---EXTERIOR 3 TRACK - \ z ' TYP• CLUSTER SHOWN CLUSTER SHOWN SILL ANCHORS (SEE SHEET 22) nRe: Dm"" By: ImpactRulsldnt `��`�ONYNiv •,,� PRODUCT REVISED as comp)yIng with the Florida SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Windows & Doors WFRE �� \)� •.' ��CENSF . (� SuBaing Code (TESTED UNfT) P• �� NOA-No. 20-0729.06 TYPICAL ELEVATION D—Hp m Data 3810W01"I"HRS SRREEhTr's,INc. Expiration Date:0912212025 ELEVATION 522/19. HIALFAH,FL33019 (305)sasaso _ n (� BY I s°""� f' ��'•''�" Ravialan: - Rev. Rom• Dam• PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE _ S. •'• S I Miami -Dade Product Control NO CHANGES THIS SHEET AGK 7/21120 N. VENICE, FL3427s 0 ATE F T •• ��` �i �s ••• ' - 4111-1600 ORION •��G Seam/NadN: Scale: Sh.1- Dmrtng No. #2929fi 7S/Q �,NALj1I��� JR.r. J(9411 REGISTRATION SGD-150 LMI N.T.S. 4 OF 28 SGD150LMI-NOA A A. LYNN MILLER. P.E. P.E.9 58705 XXX (SHOWN) OXX XXO XXX (REVERSE) DOOR FRAME WIDTH H L J1 H 0 1 L 0 XXXXXX (SHOWN) OXXXXO DOOR FRAME WIDTH c H J H K o K 0 XXXXXX (SHOWN) THIS APPROVAL QUALIFIES DOORS WITH APPROVED ' CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS, SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO t60:0 PSF © II EXTERIOR U FRAME V NON-REINF. INTERLOCKS SEE CHART ON SHEET 131\ , 1 11 O- I I I I HO I I I I L H EXTERIOR H 90' CORNER DETAIL '0' ON SHEEP 22 J7 HH 135' CORNER DETAIL 'P' ON SHEET 22 NOM: PANEL WIDTH OPTIONAL IN LIEU OF J1 ' O II O F O .,II.. _SHE 11 OVNO O- I I O EXTERIOR 90• CORNER DETAIL '0' ON ET 2 135' CORNER DETAIL 'P' ON SHEET 22 N-REINF. INTERLOCKS OPTIONAL IN LIEU OF J SEE CHART ON SHEET 13 XXXXXO (SHOWN) © I 1 (9) EXTERIOR OXXXXO PRODUCT REVISED APPROVED CONFIGURATIONS as complying with the Florida NON —POCKETED DOORS (NON -REINFORCED SHOWN) Building Code NOA-No, 20-0729.06 SEE SHEEP 13 FOR DO AND REINFORCING OPTIONSExpiration Date: 04/22/2025 THREE (3) TRACK By:_ 1i"7 T• //. -. NOTE: Miami -Dade Product Control 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS. REQUIREMENTS AS APPUCABLE PER FBC. 135' CORNER DETAIL 'P' ON SHEET 22 OPRONAL IN LIEU OF J1 SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK CONFIGURATIONS 5122/19 Revlsfo Re, Ry: I Rev. D&I NO CHANGES THIS SHEET AGK 7/21/20 SGD-150 LMI I N.T.S. 15 OF 28 I SGD150LMI-NOA I A � O a F. INTERLOCKS T ON SHEET 13 `1111II...... ' OImpactRoslsiald Windows & boors .• ' �ICENSF • �! wesesmoNam� �: • COI DOORS ANDWINDOWS, INC. '.� HIA�LPWLAII•1 _ ?C No. 58705' (aosl sssesao - PREPARED BY LYNN MILLER '•, Q: 1070 TECHNOLOGY DRIVE �) N. VENICE, FL 34275 (941)480.1600 �s '- � )RIOP..•'G\?� REGISTRATION M296 iONALIEN��� A. LYNN MILLER, P.E. P.E.# 58705 DOOR FRAME W. Ll 11 PXXX(SHOWN) XXXP DOOR FRAME WIDTH H J H . to - al g LM M J PXXXXXXP (SHOWN) • DOOR FRAME WIDTH SLL UKAKI UN JKLGI 10 I la K• H H 3b la g II M. K PXXXXXX(SHOWN) XXXXXXP DOOR FRAME WIDTH F T— lY U YU O K o o M PANEL WIDTH MnM-RFIMF INTFRI ❑CKC =, _ _ ��_ _ ••-==-tea �� THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF DOOR FRAME WIDTH PANEL WIDTH NON-REINF. INTERLOCKS m U v EXTERIOR v 90• CORNER DETAIL '0' ON SH ET 22\ v v 135' CORNER DETAIL 'P' ON SHEEP 22 OPTIONAL IN LIEU OF J DOOR FRAME WIDTH 1 NON-REINF. INTERLOCKS 4\ EXTERIOR v �' "-' II " PANEL WIDTH ". I 9O' CORNER DETAIL '0' ON SHEEP 22 POCKET CAVITY NOT BY CGI 135' CORNER DETAIL 'P' ON SHEET 22 _ NOT PART OF THIS NOA OPTIONAL IN LIEU OF J DOOR FRAME WIDTH 1 Ml1M-RFIMF 'IMFRI nf:KC PXXXXXO(SHOWN) EXTERIOR PRODUCT REVISED APPROVED CONFIGURATIONS OXXXXXP as complying with the Florida POCKETED DOORS (NON -REINFORCED SHOWN) Building Code SEE SHEET-13 FOR Dp AND REINFORCING OPTIONS NOA-No. 20-0729.06 NOTE: Expiration Date: 09/22/2025 -THREE (3) TRACKS BY.— Isla 1. "`-1. Miami -Dade Product Control - POCKETS ARE NOT PART OF THIS APPROVAL , AND TO BE REVIEWED BY AHJ. 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. 135' CORNER DETAIL -P- UN 5HLLI 2L I, OPTIONAL IN LIEU OF J DBe: - Dmwn Ry: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK CONFIGURATIONS NO CHANGES THIS SHEET Sedee/Modeh 115 - SheaL• SGD-150 LMI N.T.S. 6 of 28 5/22/19 Re, W. Rev. Date: AGK 7/21120 —In9 No. Rei SGD1501 I-NOA A `tt1t11uurr�� v � OImpact ResistantNablus; & Doors : ` \� ,.'� "! 2j/ �'•; Q'; '•_� ' WEREETROlicm_ CGI DOORS AND WINDOWS. INC. • •g'c : No.58705- '. 3780w1D4THSTREET HIALEAH, FT. 33018 _ �• PREPARED'BY LYNN MILLER - '• L A • J �\� 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 ��.(� • : �s ''•F<ORIDP.•'• \\ , (941)480-1500 •'�is�ONAL ``• REGISTRATION#29296 4111I1111 A LYNN MILLER. P.E, P.E.# 58705 XO (SHOWN) OX �H 8 --CL: XX 1 DOOR FRAME WIDTH rs N H w J1 0 (C X'6 (SHO OXO (REVERSE) 1 nv caeuc wmn� _ a 'KJ V uieniUn U 90' CORNER DETAIL '0' ON SHEET 22 135- CORNER DETAIL 'P' ON SHEET 22 A"nWAI IN I IFII nF .H THIS APPROVAL- QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135- CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF PRODUCT REVISED, as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 Mlaml-Dade Product Control 'KJ V uieniUn U 90' CORNER DETAIL '0' ON SHEET 22 135- CORNER DETAIL 'P' ON SHEET 22 A"nWAI IN I IFII nF .H THIS APPROVAL- QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135- CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF PRODUCT REVISED, as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 Mlaml-Dade Product Control • OXXO 90' CORNER DETAIL '0' ON SHEET 22 - XXXX (SIMILAR) 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF J1 1111111 Titre: DT- By: - ImpeCl R9sl,<tmlt LYN�j // ` , � D1Y '� (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dip AND REINFORCING oPnDNs: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Wlndmlrs Doors Wfle 111FNM9m- ��.••' ICENs'• . - N..iptron: Dete: CGI DOORS AND WINDOWS. INC. P TWO L2) TRACKS CONFIGURATIONS 6122/19 atALEAHB S318STRT 3780 AH, R93018 (305)I93e590 - - '�` No.58705 NOTE: - 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. R-Leron: R— W. Rev. Dote: PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE p '. I •1 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. NO CHANGES THIS SHEET AGK 7/21/26 N. VENICE, FL 34275 • 941 480-1600 .•• STATE F (� ' (V� F 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. e1 Swhc Shoot:I O REGISTRATION#2929ti \\` ,///S�0NAL 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. SGD-1 OLMI N.T,S. 7 of 28 SGD750LMI-NIA A I�NG A. LYNN MILLER, P.E. P,E.#58705 UUUM POCKET CAVITY NOT BY CGI nnno Coeur win�u I�FRAME NOT PART OF THIS NOA WIDTH I I ��mo to la a 0 M I(7 I L O PX (SHOWN) XP ' DOOR FRAME 10 0 C, L1 M M II J PXXP DOOR FRAME WIDTH �c H H SEE CHART ON SHEET 13 r. rd 0 ltnk? I I�' 0 3y� yA�J YI IYL3 Mr! YI 1 0 0 O I O Isn O a a a a 0 M M L J - %.l CYTCDI/\A 11 /1 11 r. PXXXXP EXTERIOR INTERLOCKS ON -SHEET 13 0 THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135" CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF DOOR FRAME WIDTH 5_ H . - H J I0 ec I iL 00 M K L PXXXX (SHOWN) PXXXO XXXXP OXXXP LY _ ._..._.. \ZY LJ \J \V 90' CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF A SEE CHART ON SHEET 13 I 110,0 MW W IL ar v v `r 90' CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF J1 Title: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) APPROVED CONFIGURATIONS POCKETED DOORS (NON -REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND .REINFORCING OPTIONS TWO (2) TRACKS IOW CONFIGURATIONS NO CHANGES THIS SHEET Sedes/Yodeh - Seafe: Sheet• , SGD-150 LMI N.T.S. 8 OF 28 00� , �L r m 0 I O o IaO a SM L1 L L PXX (SHOWN) XXP Y 0 !1. I NOTE: 1. CONFIGURATIONS SHOWN FOR .ILLUSTRATION PURPOSES ONLY. O EXTERIOR J7 ® 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. 90' CORNER DETAIL '0' ON SHEET 22 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 135' CORNER DETAIL 'P' ON SHEET 22 - OPTIONAL IN LIEU of J1 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. DOOR FRAME WIDTH NON-RFINF_ INTFRI nr:KS PRODUCT REVISED as complying with the Florida Building Code NOP-No. 20-0729.06 Expiration Date: 09/22/2M By; 151«2. 1. Mlaml-Dade Product Control POCKETS ARE NOT PART OF THIS APPROVAL AND TO BE REVIEWED BY AHJ. AGK 5/22/19 Rev. By. Ray. Data: AGK 7121120 SGD15OLMI-NOA 1'A Heslrta)11 ION O'NY LYArN OImpact Windows & Doors ,N 0 -. UGENSF.'-•����i C131W µD WINDOWS, INC. 3.180 W f041H STREET ��• '•. HIALEAFI,FL3301S No. 58705 (305)6934ZO - PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE = _ 1, 1 zo 7 N. VENICE. FL 34275 941 480.1600 %\'•, AT •-' �tlJ�� REGISTRATION#29296 A LYNN MILLf�,IP.�� \ �.E#58705 FRAME WIDTH • a r/=ET 13 XXXX (SHOWN) OXXX- XXXO XXXX (REVERSE) XXXXXXXX (SHOWN) OXXXXXXO THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90- & 1W CORNER STILES , LIMIT MAX. DESIGN LOADS TO ±60.0 PSF PRODUCT REVISED _ NOTE: as comp)yIng with the Florida , APPROVED -ONFI , RATIONS' 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES.ONLY. Building Code NOA-No. 20-0729.06 NON —POCKETED DOORS (NON -REINFORCED SHOWN) 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. Expiration Datee 09/2212025 - SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS 3: FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. BY: _ I s Y.? f . i.4,,.1. FOUR (4) 'TRACKS 4. DOOR SHALL, MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. Miami -Dade Product Control _ 11111i iiff - nRe Drawn Sr. AGK impact Resistant .•� �QNY LYNN�- Windows & Doors SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) xRReamall3m-- Descnp5an: - Oats: OO! DOORS AND MNIx1VlS INC, 3T3DW10QHfifREET -;' N0.58705 -•� CONFIGURATIONS 5/22/18 HWXM.(30)5934591) ms Revision: Rev. By. Rev. Data: PREPARED BY LYNN MILLER L� 1070 TECHNOLOGY DRIVE . Q ..• S AT F N. VENICE. FL n 4/u NO CHANGES THIS SHEET AGK 7l21/20 .,� (941)48D.1600 ��� •••��RIDP.••' N Scale: Sfieet Dmwf.g Na - - - �/v SI �G SeAes/lfodet REGISTRATION#29298 SGD-150 LMI N.T.S. 9 OF 28 JRev. SGD150LMf-NOA A A. LYNN MILLER, P.E. P.E.# 58705 XXXXXXXX (SHOWN) OXXXXXXO XXXXXXXO (SHOWN) - OXXXXXXO THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES . LIMIT MAX. DESIGN LOADS TO t60.0 PSF a ram_ �= --•�I ions= o_ter 90• CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OP IONAI_ IN LIEU OF J - 9W CORNER DETAIL 'O' ON SHEET 22 - 135' CORNER DETAIL 'P' ON SHEET 22 - - OPNONAL IN LIEU OF J 'NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. APPROVED CONFIGURATIONS 2. FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. NON —POCKETED DOORS (NON -REINFORCED SHOWN) - - SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. FOUR (4) TRACKS - Tiye: Drown SY: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK DeecrlPBpn: Date: CONFIGURATIONS 5/22/19 RaHslon: Rev. Sr Re, Date: NO CHANGES THIS SHEET AGK 7/21/20 Senee/Nodel: Scale: Sheet: Draring No. - h SGDA50LMI N.T.S. 10 OF 28 SGD15OLMI-NOA PRODUCT REVISED as complying with the Florida Building Code NOA-No.' 20-0729.06 Expiration Date: 09/22/2025 By; Mlaml-Dade Product Control OImpact Resl6ieM .�� O�Y LYN,tr Windows 6 Doors : ` �� • • �Lj/ ': wenEcmoxaet- `1 ..• L1CG1uSC . ({ CGI DOORS AND WINDOWS, INC. Q: • F 378D W IOtiH STREET •'. HW.EAH. FL33018 = 17 : NO, 587C5 (305) 6034500 PREPARED BY LYNN MILLER - `>] _- 1070TECHNOLOGY DRIVE. `I �, � F !7 N. VENICE, FL34275 : ` (941) 480-1600 ' �'� •'• E" REGISTRATION#20296 ��S�O/�rqL'G�G . LYNN MILLEiii`P.�.11P.E.#58705 j PXXXX (SHOWN) XXXXP r DOORFRAME WIDTH I iY. p� O la 0 2, M L N PXXXXXXXXP (SHOWN) kV kE) txltt(IUK U APPROVED CONFIGURATIONS POCKETED DOORS (NON —REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR (4) TRACKS POCKETS ARE NOT PART OF THIS APPROVAL AND TO BE: REVIEWED BY AHJ. THIS APPROVAL QUALIFIES DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 90' AND 135- CORNERS WHERE STILE CONFIGURATIONS SHOWN ON SHEET 22 ARE PRESENT, FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO ±60.0 PSF 90' CORNER DETAIL '0' ON SHEEP 22 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN IJEU OF J PRODUCT REVISED as complying with the Florida Building Code NOTE: NOA-No. 20-0729.06 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. Expiration Date:09122/2025 2: FOR APPLICABLE NON REINFORCED OR REINFORCED DESIGN PRESSURES SEE SHEET 13. BY: I sti r. Gf—'. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. Miami Dade Product Control 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPUCABLE PER FBC.' 11III11 Ptle: - Dmrn By: Impact RBSIBLnt L \ . ���� ONY vrd/V''��i� SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Wlnd9ria ✓i Doors ��•.• �7� 4 xEsn:osarR— � � �ICENS�: •• Deec PBon: ate: CDI DOORS AND W WDOWB, INC. 3780W1047HSTREEr = .' N0.58705 EXTRUSIONS, BOM 5/22/19 HULLEWFL33018 (305)593-6590 PREPARED BY LYNN MILLER 1 �l���LLyy' - Revision: - Rev. By. Re, Data: 1070 TECHNOLOGY DRIVE ` ! �'� .Z.D ST NO CHANGES THIS SHEET AGK 7/21/20 N. VENICE, FL 3427E (941)480-1800 T TE F •'�; %��•'•':4ORIDP' 8aries/Modeh - Swle: Sheet Dmeing Na: Rar.NC-) REGISTRATION #29298 r�lv/aL.IrG���� SGD-150 LMI N.T.S. 11 OF 28 SGD150LMI-NOA A A. LYNN MILLER, b.11. P.E#58705 DOOR FRAME WIDTH �L W R. OO a SM L , I I Ito lY U Ia. PXXXXXXXX (SHOWN) XXXXXXXXP OXXXXXXXP POCKET CAVITY NOT BY CGI NOT PART OF THIS NOA DOOR FRAME WIDTH I— L pm O 0 a oM L PXXXXXXXO (SHOWN) APPROVED CONFIGURATIONS POCKETED DOORS (NON —REINFORCED SHOWN) SEE SHEET 13 FOR Dp AND REINFORCING OPTIONS FOUR -(4) TRACKS POCKETS ARE NOT PART OF THIS APPROVAL AND TO HE REVIEWED BY AHJ. THIS APPROVAL QUALIFIES_ DOORS WITH APPROVED CONFIGURATIONS SHOWN WITH 99 AND 135' CORNERS WHERE STILE CONFIGURATIONS SHOWN ON- SHEET 22 ARE PRESENT. FOR DOORS USING 90' & 135' CORNER STILES LIMIT MAX. DESIGN LOADS TO f60.0 PSF INTERLOCKS ON SHEET 13 O I I O 0 0 " 0 \� 11 0 EXTERIOR 0 G2 90' CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN UEU OF J FRAME WIDTH , NOM. PANEL WIDTH . r.NON-REINF. INTERLOCKS �� !tJL m lJ LJ L'l L'l `/ \D `:/ LA I LMUH u 117 CORNER DETAIL '0' ON SHEET 22 135' CORNER DETAIL 'P' ON SHEET 22 OPTIONAL IN LIEU OF J NOTE: 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. 2. FOR APPLICABLE.NON REINFORCED OR REINFORCED DESIGN' PRESSURES SEE SHEET 13. 3. FOR ANCHOR DETAILS SEE SHEETS 15 THRU 23. 4. DOOR SHALL MEET EGRESS REQUIREMENTS AS APPLICABLE PER FBC. Title: umrn oy. SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK Desedpt10 Dole: CONFIGURATIONS 5/22/19 . Revision: - Rev. W. Rev, Date: NO CHANGES THIS SHEET AGK 7/21/20 Senv/Nadel: Scale: Sheet: D.Mg Ro. �R. SGD-150 LMI N.T.S. 12 of 28 SGD15OLMI-NOA A PRODUCT REVISED as c 1ging with the Florida Bullding Code NOA-No. 20-0729.06 Expiration Date: 09/22/2025 By: • Mlaml-Dade Product Control . 11111111 !! OImpeDliuldent �.�` Ck,V LYNIV iffinilm & Doors 11ren6amoRaFD--. � �•.•.. CGI DOORS AND WINDOWS. INC. �:' •.� 3780 W 104TH STREET - No. 58705 HNLENI, FL 33018 Iv - (305) 6D8500 _ PREPARED BY LYNN MILLER�� O 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 TE F (941) 480-1600 i �`s ': e<DR101`, ' G\7 REGISTRATION #29296 �5/ONAL. 7!l11111110 A. LYNN MILLER. P.E. P.E.# 58705 C DESIGN LOAD CAPACITY - PSP (GLASS) NOLL PANEL VADTH Duos DOOR RUNE HEIGM ucxs NI111BER OF PANELS ` L GLASS TYPES 'A' &.'A1' GLASS TYPES 'B' & '11' Di9'ERLOCES W/o REM. INTERLOCKS IFITH REUNIF. DR.(+) INT.(-) DR.(+) INT.(-) 24-1/8 30-1/8 38-1/8 42-1/e 48-1/8 54-1/8 B2 - 10 - 60.0 80.0 80.0 80.0 10 60.0 60.0 80.0 80.0 10 60.0 60.0 60.0 00.0 10 60.0 60.0 80.0 80.0 10 60.0 60.0 80.0 80.0 9 53.3 53.3 71.1 71.1 24-1/8 30-1/11 36-1/e 42-1/8 48-1/8 54-1/8 84 10 60.0 60.0 80.0 80.0 10 60.0 60.0 e0.0 80.0 10 60.0 '60.0 90.0 80.0 10 60.0 60.0 S0,0 80.0 10 0 60N53.3 60.0 80.0 8,0.0 9 53.3 71.1 71.1 24-1/8 30-1/8 3B-1/8 42-1/B 48-1/8 90 10- 60.0 80.0 80.0 10 80.0 50.0 80.0 10 60.0 80.0 80.0 10 60.0 80.0 80.0 9 80.0 90.0 80.0 24-1/8 - e 38-1/ 48-1/8 - 96 _ 10 60.0 .60.0 80.0 80.0 60.0 60,0 60.0 fi0.0 • B0.0 80.0 10 60.0 60.0 9 60.0 60.0 80.0 80.0 GLASS TYPES 'A', 'B', 'Al', 'Bl' INTERLOCKS WITH REINF. . EXT.(+) INT.(-) 24-1/8 30-1/8 36-1/8 42-1/8 48-1/8 54-1/e 102 10 - - 60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 50.0 10 - 60.0 6D.0 10 60.0 80.0 9 - - 54.4 54.4 24-1/8 30-1/8 35-1/8 42-1/8 48-1/8 .53-1/8 108 10 60.0 60.0 10 - - '60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 60.0 10 - - 60.0 60.0. 9 - - 54.4 54.4 2471/8 30-1/8 38-1/8 42-1/8 48-1/8 114 10 - - 60.0 60.0 10 - - 60.0 60.13 10 - - 60.0 60.0 f0 - 60.0 60.0 9 - - e0,0 60.0 24-1/B 30-1/8 36-1/e 42-1/e 48-1/8 120 10 - 60,0 6D.0 10 - - 60.0 60.0 10 - - 60.0 80.0 10 - - 60.0 60.0. 9 - 60.0 60.0 GLASS CAPACITY CHARTS 7NO..DTH �-n'OM. PANEL WIDTH NOM. PANEL WIDTH NOAi. PANEL WIDTH APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY AHJ. 1 1 INIZIRICICKS INTKRL.00KE W/O REINF. WITH REINF. E8 E8.1 o 6 N MI a1 M JLJL- N N SILL RISER ITEMS E8 OR EBA ARE REQUIRED FOR LOADS ABOVE +60.0 PSF ONLY. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION . DECLARATORY STATEMENT DCA05-DEC-219 7711. uro- %: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK GLASS CAPACITY CHARTS Revision: NO CHANGES THIS SHEET Serfes/Aladel: Scale: sheet: SGD-150 LMI N.T.S. 13 OF 28 Date: 5/22119 Rev. By, Rev. Data AGK 7/21/20 Droving No. Ref SGD15OLMI-NOA A PRODUCT REVISED as complying with the Florida Building Code ' NOA-No. • 20-0729.06 Expiration Date: 09/22/2025 By: le-7 Miami -Dade Product Control VA..��. ImpactResistant:�� Windows & Doors ��.••'`carts ' �! /�� � �i.• rIF11E 61RDNGFA^ '. F CGI DOORS ANO WINDOWS, INC. 3780 W 1D4TH STREET may.^' - No. 58705 - �. •, - HW.EAKFL33018 (3D6) 5D3E590 h'' '_ -D '. - •'7 �1 j _ PREPARED BY LYNN MILLER = � '. ASP 1070 TECHNOLOGY DRIVE N.VENICE, FL34275 FU �.T •.• (�-� •; e<ORIOr.••'G��� '�i SQ ..... • ' (941) 480-1600 \ i " I ;GNAL �� REGISTRATION #29298 1111I I l l \ \ A. LYNN MILLER, P.E. P.E.# 68705 3/18- ANN. GLASS 3/16" ANN. GLASS ' .075' Interlayar .075" Interlayer Saflex,CP With PET Core Saflex CP With PEr Core - By 'Eastman Chemical Co. . By 'Eastman Chemical Co.' OR OR .090' Interlayer .090' Interlayer " Saflex Clear And Color Glass Saflex Clear And Color Glass By 'Eastman Chemical Co' - By 'Eastman Chemical Co.' OR OR ' 090' Interlayer 3/ B" AIR SPACE .090" Interlayer - SentryGlas - Sol By 'Kul America, Inc.' By 'Kuraray America, Iac.' OR OR 090' Interlayer 3/16- TEMP. GLASS 090" Interlayer Trosifol PVB Trosifol PVB ,By 'Kul America, Inc.' By 'Kuraray America, .Inc.' 3/16" HEAT STREN'D GLASS 3/16- HEAT STREN'D GLASS SILICONE GE SCS 1200 - SILICONE GE SCS 1200 m DOW CORNING 791, m DOW CORNING 791, z 899, 983 & 995 z rn 899, 983 & 995 z M1 M1 XL EDGE SPACER O n STT.. STEEL BY 'CARDINAL' O DURASEAL BY 'QUANDP W4 - SETTING BLOCKS 19 OR SUPER SPACER BY 'QUANIX ' O AT 1/4 POINTS ON LLIES O O a 1 III�By-III WIDER THAN 36" 9 1 SETTING BLOCKS ir] EPDM DUROMEfER 85t5 [z1 AT 1/4 POINTS ALL SIZES EPDM W F L_R11J - AFC! W DUROMErER 85*5 W GLASS TYPE 'A' GLASS TYPE 'Al' 7/16" OVERALL LAM. GLASS 1" OVERALL INSUL LAM. GLASS , GLAZING OPTIONS 3/16" HEAT.STREN'D GLASS .075' Interlayer Saflex CP With PET. Core By 'Eastman Chemical Co.' OR - ,090" Interlayer Saflex Clear And Color Glass ByR' 'Eastmon Chemical Co.' O 090" Interlayer 3/8- AIR SentryGlae By 'Kuraray America, Inc.' OR .090' Intel 3/16 TEMP. Trosifol PVB - - By 'Kuraray America, Inc.' 3/16' HEAT STREN'D GLASS SILICONE --GE SCS 1200 DOW CORNING 791, 899, 983 & 995 Mi SETTING BLOCKS AT 1/4• POINTS ON LITES WIDER THAN 36' EPDM DUROMEIER 85f5 GLASS TYPE 'B' 7/16- OVERALL LAM. GLASS ` 3/16" HEAT STREWD GLASS .075" Interoyer Saflex CP With PET Coro By 'Eastman Chemical Co.' OR .090" Interlayer Saflex Clear And Color Glass BR'Eastman Chemical Co. PACE 090' Interlayer SentryGlas By 'Kuramy America, Inc.' OR LASS 090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 3/16' HEAT STREN'D GLASS SIUCONE �! GE SCS 1200 DOW CORNING 791, .z 899, 983 & 995 M1 XL EDGE SPACER n Sr. STEEL BY 'CARDINAL' OR DURASEAL BY 'OUANEX' OR O - SUPER SPACER BY 'QUA NEW W 1 SETTING BLOCKS ' AT 1/4 POINTS ALL SIZES - EPDM DUROMETER 85±5 GLASS TYPE 'B1' 1' OVERALL INSUL LAM. GLASS PRODUCT REVISED as complying with the Florida Building Code NOA-No- 20-0729.06 Expiration Date:99/22/2025 MiamFDade Product, Control ' - Title: SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) Drown Dy. _ AGK Impact Resistellt ®Windows,& Drip rlelrear9oxam \......I � �� . ' L1cGNgF •.!((� = i � �•: •' No.. 58705 .� a w p on: GLAZING DETAILS Dote:. - - 5/22/19 ' CGI DOORS AND WINDOWS, INC. 3780 W 104TH STREET HIALPJW, FIL 33018 (305) 593-13 a - PREPARED BY LYNN MILLER 10707ECHNOLOGY DRIVE N. VENICE, FL 34275 01) ;71 •• r% �I h O •r. 1 TE F : • •� i��s F�oRiOr+,._• ' ���` / O•. •••. •GNG ' NAL IIWI+++`� 'Ili A LYNN MILLER, P.E. P.E.#58705 Rev(slon: ADDED BACKBEDDINGS Rev. Ey, AGK Rev. Date: 7/21120 Sedes/Model: SGDA60LMI Seale: N.T.S. Sheah 114 Or: 28 pmwing No. SGD150LMI-NOA Rev: A REGISTRATION#2N296 DESIGN LOAD CAPACITY - PSI? (ANCHORS) . PANS. WDTH "Im. FRW�EIGKT elq® ANCHORS (TYPE A. B & C) ANCHORS (TYPE B2) CLUSTIM Al SD K ENDS C11ri'IeR AT SRLE/INTBBDCK EMS a e 8. 4 e e IXT. TNT. -) INT.C- INT.C-) EXT.(+) PIT. - IXf.(+) INT.C-) E%T.(+) INT.-) 24-1/e 30-1/8 36-1/8 42-1/5 48-1/8 54-1/B 82 OD.O 80.0 - - 80.0 80.0 - - - 80.0 - - 76.2 80.0 - - 72.4 80.0 6B.7 80.0 - 88.8 80.0 63.4 80.0 - 62.8 71.1 59.5 71.1 71.1 24-1/8 30-1/8 36-1/e 42-1/B 40-1/8 54-1/0 84 80.0 - - 00.0 - - 80.0 - - 60.0 - - 75.5 -60.0 - 71.6 80.0 - 67s 8D.0 14.3 BOA - b2.3 8D.0 - 59.1 BD.O a0.0 58.4 1 71.1 1 71.1 55.3 71.1 71.1 24-1/8 30-1/a 36-1/8 42-1/a. 48-1/8 90 - 80.0 80.0 - 80.0 - 75.6 80.0 - 8D.0 - 65.6 80.0 - 80.0 58.7 BO.D 80.0 80.0 80.0 53.7 80.0 80.0 24-1/8 3 - 4e-1/6 N73.8 - - 80.0 - - 08:, - 69.9 80.080.0 - ea.8 80.042-1/ 80.0 54.0 BD.O 90.0. 51.9 77.9 80.0 49.3 73.9 1 50.0 24-1/8 30-1/8 38-1/e ' 42-1/8 48-1/0 54-1/8 102 60.0 60.0 - 60.0 60.0 - - 59.3 50.0 60.0 56.2 60.0 80.0 52.7 80.0 60.0 50.0 60.0 60.0 47.9 60.0 60.0 45.5 60.0 60.0 44.3 54.4 54.4 42.0 54.4 54.4 .24-1/8 30-1/B 36-1/8 42-1/B 48-1/9 54-1/8 105 60.0 - - 60.0 - - _ 80.0 - - 60.0 - - 55.3 60.0 60.0 52.5 60.0 60.0 49.1 BO.O 80:0 46.8 60.0 80.D �44.5 41.6 fi0.0 54.4 80.0 54.4 42.2 39.4 80.0 54.4 60.0 54.4 24-1/a 30-1/8 38-1/8 42-1/6 ' 48-1/8 114 60.0 - - 60.0 - - 60.0 - -' 57.2 80.0 60.0 51.9 80.0 1 60.0 49.2 60.0 60.0 45.9 60.0 60.0 43.B 60.0 _60.0 41.5 60.0 1 60.0 39.4 59.1 60.0 24-1/e 30-1/8 36-1/1 42-1/8 48-1/8 120 60.0 - - 50.0 - - 56.9 60.0 60.0 54.0 80.0. WEE 48.11 60.0 110.0 46.3 60.0 - 80.0 43.1 60.0 60.0 40.9 fi0.0 60.0 30.9 58.4 fi0.0 38.9 55.4 80.0 TYPICAL ANCHORS. SEE ELEV. FOR SPACING In ANCHORS IN STERS AT MTG. SDLE TYPE 'A'- 1/4". ULTRACON BY 'ELCO'(Fu-177 KSI. Fy-155 KSI) & INTERLOCK ENDS, SEE 2! . AT HEAD THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE CHAR, FOR QUANTmEs s, JAMBS 1-1/4" MIN. EMBED INTO CONCRETE GE DIST. THRU 1BY BUCKS OR DIRECTLY INTO MASONRY 3 5/8' 1-1/4" MIN. EMBED MASONRY (® JAMBS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD TYPE W- 1/4- KWIK-CON II+ BY 'HILTI' (Fu=138 KSI, Fy=137 1) AT HEAD, INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD JAMBS ANCHOR TYPE A TYPE 'B'- 1/4" ULTRACON BY 'ELCO' (F-1177 KSI. Fy=155 KSI) INTO 2BY AT HEAD THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE CTURES-..•--•--�, �, ' 2" MIN. EMBED INTO CONCRETE (® HEAD)_ - JAMBS 1-1/4" MIN: EMBED INTO CONCRETE OR MASONRY (® JAMBS) 1/4" ULTRACON+ BY 'DEWALT' (Fu�164 KSI, Fy=148 KSI) TYPICAL ANCHORS IN THRU 1BY BUCKS OR DIRECTLY INTO CONCRETE CLUSTERS AT MTG. STILE INTERENDS. S &CHARTLOCK 1-3/4" MIN. EMBED INTO CONCRETE FOR QUANTITIES 1-1/4" MIN. EMBED INTO CONCRETE OR MASONRY ( JAMBS) TYPE 'C'- 1/4" DIA. SELF DRILLING SCREWS (GRADE 5 CRS) EDGE"dl ". ..°3 Sya` :'' ; 'CON( ,AT HEAD INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR OR JAMBS INTO METAL STRUCTURES (HEAD/SILL/JAMBS) ry (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM: 1/8" THK. MIN. (6063-T5-MIN.) t 6 .STEEL- 1/8" THK. MIN. (Fy = 36 KSI MIN.) a (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ANCHOR TYPE B DIRECTLY INTO 3 KSI ETE 'TYPE 'B2'- 1/4' DIA. ULTRACON BY 'ELCO' (Fu-177 KSI. Fy-155 KSI) AT SIU 1/4" DIA ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 K50 POURED DENED, NON -META z DIRECTLY INTO CONCRETE NON- INKAGE HIGH -STRENGTH GROU , 1-3/4" MIN. EMBED INTO CONCRETE f'c 50DO PSI MIN. 0 1 /4" KWIK-CON II+ BY 'IiIL11' (Fuo138 KSI, Fy=137 KSI) T BY CGI; MUST TRANSFER SHEAR INTO 2BY WOOD BUCKS OR WOOD STRUCTURES LOADS TO STRUCTURE J 1-3/8" MIN. PENETRATION INTO WOOD CLUSTERS AT MTG. STILE &-INTERLOCK ENDS, SEE CHART FOR QUANTRI :DGE ---- SEE NOTE ONCRETE•• ' 4' o ANCHOR TYPE A THRU 13Y WOOD BUCKS INTO 3 KSI CONCRETE ,I TYPICAL ANCHORS IN j CLUSTERS AT MTG. STILE i & INTERLOCK ENDS, SEE CHART FOR QUANTITIES EDGE DISi. iV mV) ANCHOR TYPE C 0 INTO METAL STRUCTURES OR APPROVED MULLIONS 1 z SEE SHEETS 14 q 18 FOR OPTIONAL S11 -X AND SHEET 13 FOR mN rr m DEWALT ULTRACON+ AND -CON II+ HILTI KWIK - """ """"' .... ...... 7 z ANCHORS LIMITED TO A MAX. SHIM SPACE OF 1/4". - 0 ac ANCHOR EDGE DISTANCER 'y3 5/$'' INTO CONCRETE OR MASONRY = 2-1/2" MIN. - INTO WOOD STRUCTURE - 1" MIN. AL ANCHORS CLUSTERS MTG. STILE 3 NOTE: - INTO' METAL STRUCTURE = 3/4' MIN. ANCHOR TYPE B2 ' _ ANCHOR CAPACITIES LISTED ON THIS SHEET TO BE USED IN WOOD AT HEAD OR JAMBS SG - 0.55 MIN. DIRECTLY INTO 3 KSI CONCRETE CONJUNCTION WITH GLASS CHARTS ON SHEET 13 LOWER CONCRETE AT HEAD, SILL OR JAMBS f c - 3000 PSI MIN. - Dra- By: APPLICABLE VALUES CONTROL 3 TRACK SYSTEM SHOWN ALSO C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm - 2000 PSI MIN. Tithe: APPLICABLE TO 2 AND 4 TRACK FRAMES. PLEASE SEE PRODUCT REVISED the Florid SENTINEL 150 ALUM SLIDING GLASS DOOR (LM.I.) AGK FOLLOWING SHEETS FOR DETAILS. Building Codewtth DescrlPtlon: Data: UMrr EXT.(+) LOADS TO 80.0 PSF FOR DOORS W/0 REINFORCING ALL SIZES NOA-No. 20-0729.0 . LIMIT FXR.(+) LOADS TO 80.0 PSF FOR DOORS W/ REINF. UPTO 96 IN. HT. Expiration Date:09/22/202 ANCHOR LOAD CHARTIANCHOR DETAILS 5122/19 LIMIT EXT. +) LOADS TO 60.0 PSF FOR DOORS W/ REINF. ABOVE 96 IN. HT. UPTO 120 IN. HIGH. - Hy: _ 1.1-77 L L/.,.,.1.. R-1.1b.: , � Rev. By: Ray. Date: WOOD BUCKS AND METAL STRUCTURES NOT BY CGI WINDOWS INSTALLATION CONDITIONS SHOWN APPLY TO t Control ADDED ANCHORS AND RE -FORMATTED SHEET AGK 7/21/20 MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND BOTH 2 TRACK AND 3 TRACK SYSTEMS WITH T Seri -/Model• SwIm Sheet - Orasfng No. Rev. TRANSFER THEM TO THE BUILDING STRUCTURE STD. FRAME HEAD AND SILL SGD-150 LMI N.T.S. 15 OF 28 SGD16OLMI-NOA A L STRUCTURES SPEC BELOW 1 -° I ANCHOR TYPE A INTO 2BY WOOD BUCKS ' OR WOOD STRINCIT,WRESIII IIIr ®Windows & Doors ��•. ' �1cENSF •,!!F` 11RIIt etiIONTBA- � Q-_- '•.� CGIDOORSANDWINDOWS.NG. - No.58705 ' 3790 W 104TH STREET ' j{ yr HIALEAH.FL31018 _ (WS)593.8M (/lMt PREPARED BY LYNN MILLER •'. ZQ1070 TECHNOLOGY DRIVE Q F . N. VENICE.FL 34275 ����••.•F<ORION-'' (941)480-1800 REGISTRATION M296 ,r77`/S/ IONI I I' 0 \` A. LYNN MILLER, P.E. P.E.# 58705 SEE SHEET 15 FOR ANCHORS c� Z /— EDGE DIST. 3 5/8' EDGE '.� mN �i. .ya v • '• di .ya v O O t ��'ri r®Iamnay VIMlt'veee THREE (3) TRACK DOOR DETAILS WEEP SIZE 1/4'-X 1/8" REFER TO SHEET 15 FOR VARIOUS INSTALLATION CONDITIONS. OPTIONAL SLANT SILL ADAPTORS PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0729.06 Expiration Date: 09/2212025 By- _ - I - y 1. !.. l,..,.::. DECORATIVE Miaml-Dade Product Control SILL COVER OPTIONAL 1 SILL RISER READ. FOR LOADS Ee.tR ABOVE +60 PSF ILL RISER EQD. FOR LOADS BOVE +60 PSF y, T ' 1t111111 r71 T De: 0mrn ey OImpact Nasistam Win 8 Doors .,pNY,.'.NN, SENTINEL150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK 91MO ttrenesmoxam- _ No. 58705 scrtP on: Date: CGI DOORS AND WINDOWS• MC. 37eD W 104TH S FIEEr 3-TRACK DOOR DETAILS 5/22/19 HALE N,Ftalo,e V45)Sr-mo -ek 7 ��Q •'•• 'C I j Revision: Rev. By. Rev. Date: .PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE NO CHANGES THIS SHEET AGK 7121/20 N. VENICE. FL34275 T '•.,.OR1DP,. (941)480-1600 `•'`G\C�� �s // Seder/Model: Scale: Sheet: -Ing No. Rer. REGISTRATION#zszes �sIQ /"1j11111101t%. SGD-150LMI N.T.S. 16 OF 28 jDS`GD15OLMI-NOA A A. LYNN MILLER, P.E. P.E.# 58705 —r +JAY■I�— 5����� 1 ' 0 K STI 1X5 OR LARGER -WOOD BUCKS FOI EXTERIOR INTERLOCK (REINFORCED) O AL ANCHORS ELEV. SPACING INTERLOCK (REINFORCED) d10 X 1-1/4- SS PH SMS ^ 1 PER CLIP (N 3 PER PANEL AT 18" FROM EACH END M2 1/4- MAX. AND AT MIDSPAN LOAD BEARIP q8 X 3/4- SS FH SMS -SHIM 1 PER CLIP FOR SPACING v� Till DOOR FRAME WIDTH I o • , ... _ FIXED -PANEL EXT � �711111tUt�� W SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) Dm- By. AGK Impact ReslsbM ®Wlndorls & Doors .�� pN , LYP...! LICENSE ?��!! '. wLwdovis _��•'' EXTERIOR Desenp on: vote CGI DOORS AND WINDOWS, INC. 3780W104THSTREEr = No.58705 DOOR FRAME WIDTH 3-TRACK DOOR DETAILS 5/22/19 HMEM.FL33 (305)5e34590 — r DOOR FRAME WIDTH 2X8 OR LARGER W000 BUCK Ravidon: R ev. By: - Rev. Date: PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE l O = %�Q ST TE : •••� OR ' WOOD STRUCTURE NO CHANGES THIS SHEET AGK 7121/20 N. VENICE, FL 34275 (941)480.1600 (� \ i s '• .. -,,. Cj _ THREE (3) TRACK DOOR DETAILS se res/Y°deL• Scaler Sheet Oaring No Rev: _ ,', /, 0NAL 1\ SGD-150 LMI N.T.S. 17 OF 28 SGD150LMI-NOA A REGISTRATION #29296 1e LYNN MILLER, P.E. P,E.# 58705 SEE SHEET 15 FOR SEE SHEET 15 FOR ANCHORS POURED & HARDENED HIGH STRENGTH GROUT NON -SHRINK, NON-MEI f'c 5000 PSI MIN. NOT BY CGI WINDOWS MUST TRANSFER SHEAR LOADS TO STRUCTURE ca ri • 3 KSI CONC. \�� 'a ••+ EDGE DIST. SHEET 15 FOR ANCHORS _ TWO (2 TRACK DOOR DETAILS -OR LOADS +60 PSF 3 KSI CONC. —SEE SHEET 15 FOR ANCHORS WEEP SIZE 1/4" K 1/8" REFER TO SHEEP 15 FOR VARIOUS INSTALLATION CONDITIONS OPTIONAL SLANT SILL ADAPTORS DECORATIVE SILL COVER OPTIONAL 1 SILL" RISER OPTIONAL FOR LOADS ABOVE +60 PSF PRODUCT REVISED as complying with the Florida Building Code Non -No. 20-0729.06 Expiration Date.09/22/2025 jay.. i sr: 7 1. G ., A, Miaml-Dade Product Control . `111111111!/!/ iftla: Vma n By: Impact Resistant ®Wlndews & Doors `��,`�.0•......1.... �10ENSF SENTINEL 150 ALUM SLIDING GLASS DOOR (LM.I.) AGK ff110RIlEA- �� ••' � �; '•:(� /WEPE CGI DOORS AND MNOOW9,INC. No.58705 Deserfp6on: Date: 3780 W 104TH STREET HIALFM,FL33018 .: _ h - ` 2-TRACK DOOR DETAILS 5/22/19 (305)5esseao = p ) %�� •. O`•I O SATE F Revielon: Rev. BY Rev. Date: PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE NO CHANGES THIS SHEET AGK 7/21120 N. VENIGE, FL34278 (941) 48D-1600 �s'•. �CORIO1% ••.•.•• . iv S Senee/Model: Scala: Sheaf: Dmwing No. -Rev: REGISTRATION iY19298 I! /Ill SGD150A N.T.S. 18 or 28 SGD15OLMI-NOA A TYPH TYPICAL ANCHORS SEE ELEV. FOR SPACING - PANEL WIDTH - - 7/2• LOAD BEARING #10 X 1-1/4- SS PH SMS 1 PANEL WIDTH ,SHI Gj 1 PER CLIP O _ D.L.O. J, . M2 j/8 X 3/4' SS FH SMS ' D.L.O. ' !++ 1 PER CUP z ��oqq i o � EB � FIXED PANEL 1BY WOOD BUCKS SEE NOTE SHEET 1 1 /2• MAX. r\ SEE NOTE SHEET 1' EXTERIOR 0 0=T= 0 PRODUCT REVISED E4 E= aS complying with the Florida ACTRAf`al - Building Code INTERLOCK - NOA-No. 20-0729.06' (REINFORCED) Expiration Date: 09/22/2025 EXTERIOR . gy;- Miami-Dade Product Control DOORI FRAME WIDTH W- L I o #10 % 1-1/4' SS PH SMS 1/4- MAX. 1 PER CUP LGAD BEARING 00 SHIM METAL - 1/2- MAX. TYPICAL ANCHORS LOAD BEARING SEE�y ELEV. X 3/4' SS FH SMS _ STRUCTURE SHIM FOR SPACING 1 PER OUP- • TYPICAL ANCHORS . _ SEE ELEV. IFOR SPACING o a EXT - w ce - DOOR FRAME WIDTH . FO (2) TRACK DOOR DETAILS FIXED PANEL 11111uIIilti� TIRe D—n By: Impact Resistant `�0,..•�•.'.., SENTINEL 150 ALUM SLIDIN LASS DOOR (L.M.I.) AGK ®Windows: & Doors •. 41cEnISF ••!! IsM3TF4XGEF- p on: - 2-TRACK DOOR DETAILS - Date: 5/22/19 CGIDOORSANDWINDOWS, INC. 3780 W 104TH STREET HALEAssL3 018 - TIr :' No. 56705 t ,'• ' PREPARED BY LYNN MILLER �) 7- l �� :• �� Revision: - Rev. Bi' Rev. Dete.• - NO CHANGES THIS SHEET AGK 7/21/20 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275 O� % S fgTE OF, F<ORIOP,.•' Z his - (941) 480.1600J. • • .... • ,,`('j� �� - Sedee/MadeL• Stele: Sheetr 0-1.g No. Rev, REGISTRATION#29298 /On SGD-150 LMI N.T.S. 19 OF 28 SGD16OLMI-NOA A A LYNN MILLER, P.E. P.E.# 58705 SEE SHEET 15 FOR ANCHORS z _ EDGE DIST. 3 5/8' EDGE EDGE GIST. 3 5/8' EDGE DIST. 3 5/8' REFER TO SHEET 15 FOR VARIOUS :. . • :. PST. .. -.. - mN ,� .. • °' ." � ' .• a;• � .. .. � .• INSTALLATION CONDI110N5. N Q d i '• • •` d' '•4 d - C WEEP SIZE 1./4" X 1/8' 11°m l m El II II OPTIONAL SLANT SILL ADAPTORS • DECORATIVESILL COVER OPTIONAL 1 III IIII III II SILL RISER _ FB.1 REOD. FOR LOADS POURED & HARDENED ABOVE +60 PSF HIGH STRENGTH GROUT ' NON -SHRINK. NON-METALLIC SILL RISER f'c - 5000 PSI MIN. Ea REOD, FOR LOADS NOT BY WINDOWS ® r--Ny-� ® ABOVE +60 PSF ' MUST TRANSFER SHEAR AN E7 LOADS TO STRUCTURE IIII © O ® ® O IIII no ® ® 1 S2 ® ¢ a PRODUCT REVISED . N ^ .' as complying with the Florida Buu Code -No. 20-0729.06 NExpltion ................_........ a Date: re9/22/2025. ` • ••'3 : a. .m • t KSI CONC. a H " :a. 3 KSI CONC. Mlaml-Dade Product Control EDGE OISi. 5/.�+ EDGE DIST. - 3 5�r EDGE DI$T. ' 3 5/.$. 1 \ SEE SHEET 15 FOR ANCHORS - rRa: Drown 1b,Impact Resmanl .` .'• l�j '� ��� FOUR (4) TRACK DOOR DETAILS SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®Windows &Doers `� ��•' �IcensR . we+�aixoneDl' • •• � • esc pU-. -. Data: - OGI DDDRAN�DDOWS, INC. 1!r ; NO. 58705 4-TRACK DOOR DETAILS 5/22/19 HHut��Fina301e PREPARED BY LYNN MILLER •.617zri. - Revtslon: Rev. By. Rev: Date: 1070 TECHNOLOGY DRIVE O• T '. AT �i/�SS•,[ORID(+..•`G`�� NO CHANGES THIS SHEET AGK 7/21120 N. VENICE, FL 34275 (91)4907600 Sheet• No. Rer. �� Seri /Model: Smle: DId in9 REGISTRATION #29296 /,ONAL SGD-150 LNII N.T.S. 20 of 28 SGD15OLMI-NOA A ' A LYNN MILLER, P.E. P.E.# 56705 1 /2- MAX. OAD BEARIr SHIM U � p O U N �A � A / TYPICAL FOF 1 /2- MAX. LOAD BEARING #10 X 1-1/4" SS PH SMS pO SHIM 1 PER CUP 00 3 PER -PANEL 0 o g TYPICAL ANCHORS AT 18- FROM EACH END M2 SEE ELEV. AND AT MIDSPAN 1/4- MAX. FOR SPACING #8 X 3/4- SS FH SMS LOAD J. HIM 1 PER CUP SHIM 1MAX. . /4- LOAD BEARING METAL L3 SHIM STRUCTURE EXTERIOR • m TYPICAL ANCHORS •`> N SEE ELEV. FOR SPACING • O N EXTERIOR PRODUCT REVISED as complying with the Florida Building Code NOA-No. '20-0729.06 Expiration Date: 09/22/2025 By: _ I V-z -'2 1 Mlaml-Dade Product Control TYPICAL ANCHORS rSEE ELEV. FOR SPACING m N N J EXTERIOR .> N . . EXTERIOR � DOOR FRAME WIDTH • W By Impact Resistant Windows 6 Doors Ll.p!/Vf/ SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M:L) AGK '`�0W! - Dete: OGI DOORS AND WINDOWS. INC. ` tT-.• .� , eeanp6on: 4-TRACK DOOR DETAILS 5/22/19 HM W ,FL 3s1REBr Hut)593-6 saole isos)ssssseo : NO. 58705 � 2%8 OR LARGER WOOD BUCK FOUR 4 TRACK DOOR DETAILS - By. Date: PREPARED BY LYNN MILLER WOOD STRUCTURE ReHA16n: Rev. Rev. 1070 TECHNOLOGY DRIVE N.. VENICE, FL 34275 �0 W. (��- .Z. �, STATE OF NO CHANGES THIS SHEET AGK 7/21/20_ (941)48G-1600 �Q� i - Sedv/Model: Seole: Sheet Dra f.q No. Rar. - REGISTRATION#29296 C'�'•.,F(OR1Di'•.•'' i/ tSsi -' • • • -' �C� ��� /,/ ZONAL 1" SGD-150 LMI N.T.S. 21 OF 28 SGD15OLMI-NOA A `� A. LYNN MILLhW V.E 1 P�E.# 58705 ' .. #10-16 X 1/2° . d• HH SELF O SCREWS END - AT 6" FROM ENDS & 12` O.C. III IFFO 90• CORNER O 135- CORNER i'. #10-24 X 1/2° FH THREAD CUTTING SCREWS AT 6` FROM ENDS] & 12" O.C. EXTERIOR 4BLE FOR OUTSIDE CORNERS ONLY AT 6' FROM ENDS & 12" D.C. 1 3/4° 3 $/B" 3 5/8° (4) ANCHORS _ >t. ,y`t` (4) ANCHORS . 6 �6 �s IB° 8• (6) ANCHORS �I (6) ANCHORS �6 �6 3, . 38• 3 J ' (8) ANCHORS v (8) ANCHORS I6 .3 �6 3 g• 3.� 3• B• -�I SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) I AGK TWO (2) TRACK THREE_(,'{) TRACK FOUR (4) TRACK TWO (2) TRACK FOUR (A) TRACK CORNER DETAILS 5/22119 Ravi.fon: Rev. Br. Rev. Dot.: NO CHANGES THIS SHEET AGK 7/21120 Se -/A del: - Scale: Sheet: Droving No. Rev. SGD-150 LMI N.T.S. 22 Or 28 aGD150LMI-NOA A PRODUCT REVISED as complying with the Florida Building Code ' NOA-No. :20-0729.06 Expiration Date: 09/22/2025 By: _ l.-l -7 1. Miami -Dade Product Control �.0'60 LYNN WImpaetN6slstaM VAndmlls & Doors '•.�� COI DOORS AND WINDOWS, INC. 3780 W 104TH STREET �:' No. 587[15 H EAH. FL33010 (sosi 59"M - '• �; -_ PREPARED BY LYNN MILLER, 1070 TECHNOLOGY DRIVE 9 '�•'•: 'Zv.••(V� N. VENICE, FL 34275 , :. �T •. ATE F (V . (941)480-1600 (C '•.'1OF.01 ••'••\=�1 REGISTRATION#29296 rlli II1111\ /1. LYNN MILLER, fl.E. P.E.# 58705 TYPICAL ANCHORS " TYPE A B OR C - - M AT 6' FROM ENDS AND 9" O.C. INTO WOOD/CCNC./METAL - 1-1/8" MIN. 6" O.C. INTO BLOCK ONLY 1-1/2' MIN. WOOD EMBED LL TYPICAL PAD PILE INSTALLATION LOCATION SEALANT EDGE DIST. 1-1/4" MIN. BLOCK EMBED - 1-3/4" MIN. CONC. EMBED 1/8" MIN.METAL THICKNESS ' EXTERIOR MOUNTED '.��� CONC. POCKETED JAMB 1 BLOCK Wool) METAL TYPICAL AT PANEL 4 CORNERS EXTERIOR POCKET CAVITY NOT BY NOT PART OF THIS T0. BE REVIEWED BY DOOR FRAME WIDTH - - - NOM. PANEL WIDTH 0 O IL PRODUCT REVISED ` O O O as camp)yIng with the Florida - Building Code NOA-No. 20-0729.06 Explratlon Date: 09/22/2025 ' Mlaml-Dade Product Control rdle: Dmlm W. Imp .d Reastnrt ®Wlndffws ;.• �� Gt..! ...:.! �s� �i� SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK & oDm cat DOORS AND WINDOWS. INe. `,L No. 58705 • � - Deecrtptl0n: Dom; 5122/19 3780 W 104TH STREET HIALFAH.FL33018 %1 DETAILS (305)593-SM - O l/l'7 ••. / 2 U •` � `O� •. SATE R-hion: Ray. Sr Rer. Dota: PREPARED BY LYNN MILLER - 1070 TECHNOLOGY DRIVE N. VENICE. FL 34275 F (U� ` '•. NO CHANGES THIS SHEET AGK 7/21120 % (� 0R101"..w'` ��� 7;5lONAL Sarise ddel: Scale: Sheet. Orowidg No. - - Rer. - REGISTRATION#29298 //!ltIllll ttt` SGD-150 UMI N.T.S. 23 OF 2B SGD16OLMI-NOA A - A. LYNN MILLER, P.E. P.E# 68705 CODE PAST No. - DESCRIPTION - MATERIAL MANUF. REMARKS CODE PART No. ..' DESCRIPTION - MATERIAL MANUP. - REMARKS E1 CGI-183 FRAME SILL 2 TRACK - 6063-TB CGI EXTRUDER - M2 CGI-171C FIXED PANEL CLIP (2-1/2" LONG) 6063-75 - -3 9 FIXED PANEL E2 CGI-151 FRAME JAMB 2 TRACK - 6063-T6 CGI EXTRUDER - M3- CGI-173 FIXED. PANEL SHIM NYLON 2 PER FIXED PANEL E3 CGI-186 FRAME HEAD 2 TRACK 60B3-T6 CGI EXTRUDER MID CGI-176 FRAME HEAD ANTILIFT &e PAD PILE WOOL/NYLON SULLIVAN 1 PER INTERLOCK/ASTR. E4 CGI-153 EXTERIOR INTERLOCK 6063-T6 CGI EXTRUDER - M11 W2320ING .'PILE WITH CENTER FIN- WOOL ULTRAFAB OR EQUIV. - E5 CGI-154 INTERIOR INTERLOCK 6063-T6 CGI EXTRUDER - M12 - BOTTOM RAIL STIFFENER, 1- LONG, 2 AT EACH END ALUMINUM CGI EXTRUDER 4 PER BOTTOM RAIL E6 CGI-155 MAIN STILE 6063-T6 -CGI EXTRUDER - M13 TA-51 ROLLER ASSEMBLY AT PANELS WITHOUT CORNERS ' 'Sf/ST ' AMESBURY 2 PER OPERABLE PANEL E7 CGI-156 TOP & BOTTOM HORIZ 6063-T6 CGI EXTRUDER - M13A 1984 ROLLER ASSEMBLY AT CORNER PANELS ST/ST AMESBURY 2 PER OPERABLE PANEL EB • CGI-157 SILL RISER 6063-TB CGI EXTRUDER M74 SGD-500 - DUAL MORTISE LOCK Sf/Si SULLIVAN ATTACHED TO SGD-503 EB.1 CGI-181 ALT. SILL RISER(OPTIONAL) 6063-T6 CGI EXTRUDER - M14A ` PS01-0036-117 DUAL MORTISE LOCK. ST/ST INTERLOCKS ATTACHED TO-M16A E9. -CGI-158 INTERIOR TRACK ASTRAGAL • 6063-T6 CGI EXTRUDER - M15 SGD-507 ,KEEPER - -• - - ZINC SULLIVAN - INST. W/ 2 {#1OX3/4- PH E10 CGI-159 INTERLOCK REINFORCING (LENGTH FRAME HT: - 6') 6063-T8 CGI EXTRUDER - MISA SGD-507N KEEPER ZINC INTERLOCKS INST. W/ 2 #10X3/4" PH E11 CGI-182 FRAME SILL 3 TRACK 6063-T6 CGI EXTRUDER - M16 SGD-503 RECESSED ADAPTOR ZINC SULLIVAN INST. W/ 2 #16X3/4" FH E12 CGI-161 FRAME. JAMB 3 TRACK 6063-T6 CGI EXTRUDER - M16A PS01-0036-117 RECESSED ADAPTOR ZINC INTERLOCKS INST. W/ 2 810X3/4" FH E13- CGI-185 FRAME HEAD 3 TRACK 6063-T6 CGI EXTRUDER" - M17 SGD-5500 HANDLE SET ZINC SULLIVAN/INTERLOCKS - E14 CGI-168 OUTER TRACK ASTRAGAL 6063-76 CGI EXTRUDER 1,118 SM2300WH HANDLE SET OPTIONAL - - ZINC SULLIVAN - E15 CGI..-170 POCKET HOOK 6063-T6 CGI EXTRUDER - M19 SCS2000 SILPRUF SEALANT SILICONE GE - E16 CGI-121 7/16" GLASS GLAZING BEAD 6063-75 CGI EXTRUDER - M20 CGI-177 - PANEL TOP"& BOTTOM DUST PILE, WOOL/PVC SULLIVAN OR -EQUN. 4 PER PANEL E17 CGI-123 1- GLASS GLAZING BEAD 6063-T5 CGI EXTRUDER - M21 WS-202 HEAD AND SILL SMALL PILE PAD WOOL ULTRAFAB OR EQUIV. 1 PER INTERLOCK/ASTRAGAL E18 CGI-153A EXTERIOR INTERLOCK (OPTIONAL) - 6063-TS CGI EXTRUDER - _ M22 WS-201 SILL INTERLOCK PILE PAD WOOL ULTRAFAB OR EQUIV. E19 CGI-154A INTERIOR INTERLOCK '(OPTIONAL) 6063-T6 CGI EXTRUDER - M23 HD-12-10042 .350' REACH POCKET SEAL - AMESBURY E20 cm -ism MAIN STILE (OPTIONAL) 6063-T6 CGI EXTRUDER - S2 - #10 X 1 1/$ LG. PHL PH. SMS., 'ST/SL ASY. SCREW - - 2 OR 3 PER CORNER - E21 _ CGI.-156A TOP & BOTTOM, HORIZ (OPTIONAL) 6663-T6 CGI EXTRUDER .. - SINGLE LOCK: FOR ALL PANELS WITHOUT CORNERS TWO POINT LOCK BY 'SULLIVAN' OR 'INTERLOCK' LOCATED AT PRODUCT REVISED MAIN STILE AT 40" FROM BOTTOM as cornplying with the Florida SS MORTISE LOCK (PART #SGD-500) (PSOI-0036-1.17) Building Code ZINC RECESSED ADAPTOR (PART #SGD-503) (PS01-0036-117) NDA-No. 20-0729.06 - ZINC HANDLE -SET (PART #SM5500) &` (PART #SM2300WH) Expiration Date:09122/2025 ZINC KEEPER (PART #SGD-507) (PART #SGD-507N) By, Miaml-Dade Product Control DOUBLE . LOCKS: REQD. AT 60' AND 135' CORNER PANELS ONLY TWO POINT LOCKS LOCATED AT MAIN STILE AT 40" AND 78" FROM - BOTTOM SS MORTISE LOCKS WITH RECESSED ADAPTORS (PART #HD-3310141) E22 CGI-MA ' ASTRAGAL (OPTIONAL) 6063-76 CGI EXTRUDER - 03 CGI-I SEA OUTER -TRACK ASTRAGAL'(OPTIONAL) 8063-T6 CGI EXTRUDER - E24 - CGI-180 DECORATIVE SILL COVER (OPTIONAL) 6063-TB CGI EXTRUDER _ - E25 CGI-la4 2, 3 & 4 TRACK FRAME SILL SCREW COVER 6063-T6 CGI EXTRUDER - E26 CGI-181 2, 3 & 4 TRACK FRAME HEAD SCREW COVER 6063-T5 CGI EXTRUDER - E27 CGI-189, FRAME JAMB SCREW COVER (OPTIONAL) 6063—T5 CGI EXTRUDER — E28 CGI-1028 FRAME HEAD 4 TRACK 6063-T6 CGI EXTRUDER - E29 CGI-1029 FRAME SILL 4 TRACK 6063-T6 CGI EXTRUDER - E30 CGI-1030 FRAME JAMB 4 TRACK 6063-TS CGI EXTRUDER - E31 CGI-1057 FEMALE CORNER ADAPTOR (90') 6063-T6 CGI EXTRUDER - E32 CGI-1058 FEMALE CORNER ADAPTOR (135!). 6063-T6 COI EXTRUDER - E33 CGI-1059 MALE.CORNER ADAPTOR 6063-T6 CGI EXTRUDER - M1 COI-382V GLAZING BULB VINYL (DUROMETER 75-80_ SHORE A) PVC - - wncu : n kcj i -c-r n ./c rn oa.-- ' BOTTOM LOCK ACTIVATES TOP LOCK WITH A MECHANICALLY ATTACHED . CONNECTING BAR (PART #HD-3310142) ZINC HANDLE SET SECURED WITH (2) 6-32 X 1-1/2"'OH MS STEEL KEEPER (PART #HD-3310143) SECURED -WITH (4) 10-24 X 1/2" PH THREAD FORMING SCREWS Omwn By. Impact ROSIStil d SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) - AGK Windows & Doors wel�sDmII9T9- �����0�'1.LYNV�,'%, � r �Lc[NSF•.!Q� CGI DOORS AND WINDOWS, INC. .•' Description: Dote: _ 3780 W 106TH STREET 5/22119 HIALEAH. FL 33018 = �r :' No, 58705 BILL OF MATERIALS (305)593-65N $ -'� (/I Rodsion: - _ Rev. t1y: - Rov. Data: PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE . • ; �0 % , NO CHANGES THIS SHEET AGK 7/21/20 N. vEMCE, FLaaz75 (941)480-1600 : '•. S¢ TFp� (q ���••yP<ORIDf�•. •'G�: Sedeodeh - Smie: Shsatr . . Otowing, No. R. ' - REGISTRATION#29z96 j t9n '',U 0NAL SGD-150LMI N.T.S. 24 OF 28 SGD150LMI-NOA A A. LYNN MIL1 2A[PIE.I 10�.#58705 4.735 070 860 .T__FfW7P7'-Lf] 1.250 Q . FRAME HEAD .075 .070 2.600 .640 F�-4.735- E1 FRAME SILL (2 TRACK) OUTER TRACK ASTRAGAL STILE F23 OUTER TRACK ASTRAGAL (OPTIONAL) 5.921 o70 --T� 847 1.250 0 FRAME HEAD .075 - L .070 2.600 .753 5.921 ��i 1 FRAME SILL (3 TRACK) INTERIOR TRACK ASTRAGAL STILE 1.625 .125 1.310 7 INTERLOCK REINFORCING 625 1.920 2.670 ® F� .625 SILL COVER(OPTIONAL) �O TOP/BOTTOM HORIZ 3.000 995 .070 1.490 1.415 LJ 2.005 E6 MAIN STILE Q INTERIOR INTERLOCK 1.786 995 •060 1.831 1.501 .156 3.000 E4 EXTERIOR INTERLOCK .741 0 SILL RISER (OPTIONAL) .675 .995 .050 .975 1.184 GLAZING BEAD LAM. GLASS 1.506� '.7125 •O65 I .664 ,125 FIX. PANEL CLIP .120 070 1.366 .695 1 .265 E8 SILL RISER 3.188 .070 1.625 .582 2.120 .(9 POCKET HOOK -i r.120 T- .995 .050I .975 1.184 f� GLAZING BEAD INSUL LAM. GLASS IA B6 060 1.831 1.501 .156 3.000 EXTERIOR INTERLOCK (OPTIONAL INTERIOR TRACK ASTRAGAL Ink. Ororn SENT)NEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK TOP/BOTTOM HORIZ" (OPTIONAL 3.000 .070 1.490IF, 1.415 2.005 MAIN STILE - 3.000 v.095 1.770L_� 1.415 O60 2005 INTERIOR INTERLOCK (OPTIONA EXTRUSIONS 5/22/19 Ra W.w ' R.. DY: Rev. Date: NO CHANGES THIS SHEET AGK 7121/20 Sarias/MadaL• Scale: Sh.t: No. Rar. Dmring SOD-150 LMI N.T.S. 25 OF 28 SGD150LMI-N0A A PRODUCT REVISED -a5 Complying with the Florida Building Code NOA-No. . 20-0729.06 Expiration Date: 09/22/2025 By; MIam4Dade Product Control �TI11 �I111/// I ReAdant `\ �QN • JIV OImpact <311ndON8 & ODOIs welaTm9xcm� .�:). 1C `: ``,� .'' LENgC •.. �� CGI DOORS AND WIHDOM, INC. 3780 W 104TH STREET tC� NO.58705 •� • • . HL.JEM FL3W18 (306)693-0890 Z . = � •c _�EOF PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRNE FL N. 4J8G-1 O�U` �i �(cJR. (9 1 0034275 �'•.`ICE, ............ .•\G\�� /s/�IIALL��:��� REGISTRATION429296 A. LYNN MILLER, P.E. P.E.i158705 4 FEMALE CORNER ADAI FEMALE, CORNER ADAPTOR (135) 1 5111 ' O60 1.650. -�{ 40 - FRAME HEAD COVER 4.765> .055 -_080 1.621 ,640. i " I.060. E25 FRAME SILL COVER 0 FRAME JAMB (2 TRACK) - - .243�1 , •-� 1.375 _ I 1.791 .. .060 1.620 FRAME JAMB COVER 5.951 .080 1.620 ,725 8 .055 .125 - I ..5�45 i • _ .1.620 .1.508 090 .065 II I I .62.664�i Imo- FRAME JAMB (3 TRACK) M2 FIXED PANEL CLIP PRODUCT REVISED' - - as complying with the Florida - - Building Code NOA-No. 20-0729.06 Expiration Date:09/22/2025 By:_ 111-7 r • Z„ , Mlaml-Dade Product Control - - `�116I1I Pf lI i. r(re: D—n By: ImplictReslatant SENTINEL 150 ALUM SLIDING GLASS DOOR) ( L.M.I. AGK ®Windows & Dnars 370TM9�WB.ING 3� ! NO. 5370580W10612E ec p8on: - Date: _ - EXTRUSIONS 5122/19 NW.EAH•FL33018 (305) 6938590 •A '• 7 2 O � '•, J.TE Revision.• - - - - Rev. ey. Rev. Oale: - PREPARED BY LYNN MILLER 1070 TECHNOLOGY DRIVE NO CHANGES THIS SHEET AGK • 1/21120 N. VENICE. FL 34275 . (941)480-1600 - � OF. I T ' �UU� i Can '•�� ORID�..''GC' //; G� uS1�NIAL \\ Spies/Model• Scale: Sheet• Na Rer. - SGD-150 LMI N.T.S. 26 OF 28 SGD150LMI-NOAOmning A REGISTRATION#29296 +\`�� 1110 m _FRAME BOTTOM CORNER 4 TRACK SHOWN PRODUCT REVISED as complying with the Florida Building Code NOA-Ho. 20-0729.06 Expiratlon Date: 09/2212026 Mleml-Dade Product Control 7.750 y .080 .925 .857 1.250 FRAME HEAD (4 TRACK) .DeD 2.600 .753 __j Lj 7.730 t29 FRAME SILL (4 TRACK) 1.375 1.620 � ann 7 FRAME JAMB (4 �l1 l:Ii lil/ Title: Dmwn Ibr ImpactRoadaet ��` 0NY,LYNiV SENTINEL 150 ALUM SLIDING GLASS DOOR (LM.I.) AGK Windows oors CGI DOCKS AND WINDOWS, INC. P an: Date: 3780 W 10UHI STREET _ No, 58705 INSTALLATION DETAILS, EXTRUSIONS 5/22/18 HWP 1N, FL 93018(a05)emass0 - G q 7 ,ZI L o Revlaioe: - Rev. sy: Rev. Date: PREPARED BY LYNN MILLER, DRIVE NO CHANGES THIS SHEET ASK 7/21120 N.7VENICE; FTECHNOLOGY ; per:• s rE F \U�` ;�`�'••.<or;lD�..••'\\� (9a1ja80-1600 ��� ZONAL Sedea/Nedel: Seale: Sheep Dm Mg K.. REGISTRATION&29296 /v71100% � SGD-150 LMI N.T.S. 27 OF 28 SGD15OLMI-NOA A " A. LYNN MILLER, P.E. P.E.0 58705 FRAME BOTTOM CORNERBOTTOM CORNER 3 TRACK SHOWN PANEL TOP/BOTTOM CORNER MITERED BEAD CORNER (TYPICAL) PRODUCT REVISED as with the Florida Building Code. Ucomplying ",j NOA-No. 20-0729.06 " Expiration.Date: 09/22/2029 Br•- PANEL TOP/BOTTOM, CORNER MIaml=Dade Product Control FRAME'BOTTOM CORNER 2 TRACK SHOWN SQUARE BEAD CORNER (OPTIONAL) rve• Omrn er Impecl Resistant ` \\0........... 9�• �'��� SENTINEL 150 ALUM SLIDING GLASS DOOR (L.M.I.) AGK ®ado&& Doors �\��• �lc[rtSF'' ���� CGI DOORS ANDWWDOWS, INC. ! = �.'- NO. 58705 •- .. serlp on: Date: . - INSTALLATION DETAILS 5/22119 HIAEET L W 1067H SR2 HIALEAH,FL33018 _a5)69a.essD _••� •: PREPARED BY LYNN MILL ER •' �(7�, �� I' r • Ravlsion; Rav, By: Re, Date: • 1070 TECHNOLOGY DRIVE %��••. ��� F .''141 NO CHANGES THIS SHEET AGK 7121/20 N. VENICE. FL 34275 %S� ,F(pR10p •.•' ��`� (941)48D-1600 isI.......... JG ' ''ONAL S` 0\\ Senas/Nadeh SwI.. Sheet DmWng H.. Rar. - -- REGISTRATION 029296 ll f I I I I I l l 1 \ " SGD-150 LMI N.T.S. 28 OF 28 SGD15OLMI-NOA A A LYNN MILLER, P.E. p.Eg 59705