HomeMy WebLinkAboutTri County Metals5V Product Approval(copy) Force Engineering & Testing
19530 Ramblewood Drive
Humble,Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: www.forceengineeringtesting.com
Product Evaluation Report
TRI COUNTY METALS
Min. 26 Ga. 5V Crimp Roof Panel over 15132"Plywood
Florida Product Approval # 26000.1 R1
Florida Building Code 2020
Per Rule 61G20-3
Method: 1—D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method:61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Tri County Metals
301 SE 16th Street
Trenton,Florida 32693
Engineer Evaluator:
Johnathan Green,P.E.#88223
Florida Evaluation ANE ID:12901
Validator:
Brian Jaks P.E.#70159
Contents:
Evaluation Report Pages 1—4
®N%W1i1111/i/ THIS ITEM HAS BEEN
®% f DIGITALLY®�/®/9 GNED AND
S ALED BYJIOHNA HAN
GREEN ON THE DATE
of ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
o o DOCUMENT ARE NOT
=7E CW CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE
BE
VERIFIEDON ANY
OCT 01 2020 ®6ef ®�a ELECTRONIC COPIES.
FL#26000.1 R1
Force Engineering & Testing
19530 Ramblewood Drive
Humble,Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: www.forceengineeringtesting.com
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2020,Sections 1504.3.2, 1504.7.
Product Description: 5V Crimp Roof Panel,Min.26 Ga.Steel,24"coverage,through fastened roof panel
over Min. 15/32"APA Plywood decking. Non-structural Application.
Panel Material/Standards: Min.26 Ga.Steel ASTM A792 AZ55,conforming to Florida Building Code 2020
Section 1507.4.3. Paint finish optional.
Yield Strength: Min.80.0 KSI
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2020,Section 1507.4.3.
Panel Dimension(s): Thickness: 0.019"min.
Width: 24" maximum coverage
Rib Height: 1/2"tall ribs
Panel Fastener: #9-15 x 1-1/2"Woodgrip HWH with sealing washing or approved equal
%"minimum penetration through plywood;@ 12"o.c.across panel through panel
ribs at interior locations;@ 6"o.c.across panel width through panel flat and rib at
panel ends.
Corrosion Resistance:Per Florida Building Code 2020,Section 1507.4.4.
Substrate Description: Min. 15/32"thick,CAT Exposure 1 CDX APA Rated plywood over supports at
maximum 24"O.C. Design of plywood and plywood supports are outside the
scope of this evaluation. Substrate must be designed in accordance w/Florida
Building Code 2020.
Allowable Design Uplift Pressures:
Table"A"
Maximum Total Uplift Design Pressure: 60.0 psf
Fastener Pattern: 12"-12"
Fastener Spacing: 16"O.C.
*Design Pressure includes a Safety Factor=2.0.
�o® Wll+'os//,, THIS ITEM HAS BEEN
r?alb
S® DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
8=3 e s
e PRINTED COPIES OF THIS
® is ; DOCUMENT ARE NOT
STJ4TEOi o CONSIDERED SIGNED AND
0 �••• i � SIGNATURE MUST BE
SEALED AND THE
/ � NN\ VERIFIED ON ANY
OCT 01 2020 //��//���'l I;,t�`\\X`® ELECTRONIC COPIES.
FL#26000.1 R1
Force Engineering & Testing
19530 Ramblewood Drive
Humble,Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: www.forceengineeringtesting.com
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2020,Section 1504.3.2, 1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020,as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06-Test for Uplift Resistance of Roof Assemblies
■ UL 1897-2012-Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-06/1897-04&-12 Uplift Test
PRI Construction Materials Technologies, LLC(FBC Organization#TST5878)
Project No.TCM-003-02-02 Dated 01/02/2018
3. Certificate of Independence
By lohnathan Green, P.E.(No.88223)@ Force Engineering&Testing
(FBC Organization#ANE ID: 12901)
Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12,lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
THIS ITEM HAS BEEN
SEALED DIGITALLY BYJI GNED AND
SOHNA HAN
`�G�MB►�••• ®j GREEN ON THE DATE
•; ADJACENT TO THE SEAL.
U158=3
e PRINTED COPIES OF THIS
DOCUMENT ARE NOT
+ • STMoor CONSIDERED SIGNED AND
i �`•• ,[� (�j SEALED AND THE
`OR10 SIGNATURE�`���\ BE
VERIFIED ON ANY
OCT 01 2020 1111'A;,t ��`� ELECTRONIC COPIES.
FL#26000.1 R1
Force Engineering & Testing
19530 Ramblewood Drive
Humble,Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: www.forceengineeringtesting.com
Underlayment: Per Florida Building Code 2020,Section 1507.1.1 and manufacturer's installation
guidelines.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2020 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2020
Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
,*Nk%jil � THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY AN
GREEN ON THE DATE
e ADJACENT TO THE SEAL.
® a ° PRINTED COPIES OF THIS
0 °
DOCUMENT ARE NOT
® MTE(� ® CONSIDERED SIGNED AND
SEALED AND THE
o,�/ oR to� ���0®\� VERSIGNATURE
FIED ON ANY BE
OCT 01 2020 1 1111
A 11% ELECTRONIC COPIES.
FL#26000.1 R1
Force Engineering & Testing
19530 Ramblewood Drive
Humble,Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: www.forceengineeringtesting.com
1•-P k ].Y i a nu
-
_ xeil' 'A1y.a:.Of u s an si-rrz n-n
Sfd13W AIIJf10 lill -3 d'0 Hd'M/9Nf1VN05 Vlie n L'
}W t
G
O
_os J
cn
Q
cn
Z
J
W
W
o
r
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
Mae= °° ADJACENT TO THE SEAL.
® 6 PRINTED COPIES OF THIS
e c _ DOCUMENT ARE NOT
81ATEOf o Q CONSIDERED SIGNED AND
SEALED AND THE
�f®' '• QRy�P .G\��o� SIGNATURE MUST BE
VERIFIED ON ANY
OCT 01 2020 'rA;,`,,\\\x ELECTRONIC COPIES.
FL#26000.1 R1