HomeMy WebLinkAboutAPPROVED 1233 Nettles BoulevardJoseph P. McCarty, Architect, Inc.
900 East Osceola Street
Stuart, Florida, 34994
772-287-6735 fax: 772-287-461 S
DPR Registration Number 9639
March 21, 2020
St. Lucie County Code Zoning Department
2300 Virginia Avenue
Fort Pierce, Florida 34962
RE: 1233 Nettles Boulevard
To whom it may concern:
Building is being re -roofed to the following design standards
Design Pressures -160 Vult- Exposure "D"
mean roof height 30'
Note sheathing to be 19/32" CDX plywood with 2 X" x 0.131, or 3" x 0.120 ring shank nails 4" on center on edges and in field
Gable Roof > 20 to 27 degrees
1.2e
10
+30.3
-75.0
L2e
20
+26.2
-75.0
1.2e
5o
+20.5
-45.8
1.2e
100
+16.5
-23.3
2n,2r,3e
10
+30.3
-109.5
2n,2r,3e
20
+26.2
-94.5
2n,2r,3e
50
+20.5
-74.5
2n,2r,3e
100
+16.5
-60.0
3r
10
+30.3
-130.0
3r
20
+26.2
-111.6
3r
5o
+20.5
-86.
3r
100
+16.5
-68.2
Hip Roof > 20 to 27 degrees
1
10
+30.2
-54.4
1
20
+26.2
-48.2
1
so
+20.6
-40.0
1
100
+16.4
-38.7
2e,2r,3
10
+30.2
-75.0
2n,2r,3e
20
+26.2
-67.0
2n,2r,3e
50
+20.6
-56.4
2n,2r,3e
100
+16.4
-48.5
Roof Underlayment - Soprema FBC FL 2569.2
Roof Shingles - Tamko Heritage FBC FL 35321
Low Slope Roof - Polyglass modified bitumen FBC FL 1654-R38
Sheathing and underlayment have been installed, shingles and low slope roof are in
progress.
I hereby certify that sheathing and underlayment have been installed to the standards
listed above and in compliance with the Florida Building Code 2020.
Sincerely,
Joe
McCart
II
Digitally signed
by Joe McCarty
Date:
2022.03.21
15:08:38-04'00'