HomeMy WebLinkAboutAPPROVED 1233 Nettles BoulevardJoseph P. McCarty, Architect, Inc. 900 East Osceola Street Stuart, Florida, 34994 772-287-6735 fax: 772-287-461 S DPR Registration Number 9639 March 21, 2020 St. Lucie County Code Zoning Department 2300 Virginia Avenue Fort Pierce, Florida 34962 RE: 1233 Nettles Boulevard To whom it may concern: Building is being re -roofed to the following design standards Design Pressures -160 Vult- Exposure "D" mean roof height 30' Note sheathing to be 19/32" CDX plywood with 2 X" x 0.131, or 3" x 0.120 ring shank nails 4" on center on edges and in field Gable Roof > 20 to 27 degrees 1.2e 10 +30.3 -75.0 L2e 20 +26.2 -75.0 1.2e 5o +20.5 -45.8 1.2e 100 +16.5 -23.3 2n,2r,3e 10 +30.3 -109.5 2n,2r,3e 20 +26.2 -94.5 2n,2r,3e 50 +20.5 -74.5 2n,2r,3e 100 +16.5 -60.0 3r 10 +30.3 -130.0 3r 20 +26.2 -111.6 3r 5o +20.5 -86. 3r 100 +16.5 -68.2 Hip Roof > 20 to 27 degrees 1 10 +30.2 -54.4 1 20 +26.2 -48.2 1 so +20.6 -40.0 1 100 +16.4 -38.7 2e,2r,3 10 +30.2 -75.0 2n,2r,3e 20 +26.2 -67.0 2n,2r,3e 50 +20.6 -56.4 2n,2r,3e 100 +16.4 -48.5 Roof Underlayment - Soprema FBC FL 2569.2 Roof Shingles - Tamko Heritage FBC FL 35321 Low Slope Roof - Polyglass modified bitumen FBC FL 1654-R38 Sheathing and underlayment have been installed, shingles and low slope roof are in progress. I hereby certify that sheathing and underlayment have been installed to the standards listed above and in compliance with the Florida Building Code 2020. Sincerely, Joe McCart II Digitally signed by Joe McCarty Date: 2022.03.21 15:08:38-04'00'