Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED shingle underComments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathieu@soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D,
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert 3. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
Certificate of Independence
Referenced Standard and Year (of Standard)
Validation Checklist - Hardcopy Received
FL2569 R21 COI 2020 01 COI NIEMINEN pdf
Standard
ASTM D1970
ASTM D4798
ASTM D6163
FM 4474
FRSA/TRI Sixth Edition
Year
2015
2011
2015
2011
2018
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FL #
2569.1
Method 1 Option D
12/16/2020
12/1712020
12/26/2020
02/09/2021
Model, Number or Name
Soprema Roof Underlayments
Limits of Use —�
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underlayment systems
used beneath adhesive -set the systems. Refer to ER Section
5.8.3 for details.
Description
Self adhering roof underlayments
Installation instructions���
FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569
R21.pdf
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569
R21. pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
ITlow I
00 ® EGh2CR
Crediti
eLlrity"tl l,Ries-
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
a a s .e
Soprema, Inc. Evaluation Report S18010.06.09-1119
1640 rue Haggerty FL2569 R21
Drummondville, Quebec J2C 5P8 Canada
(819) 478-2400 Date of Issuance: 06/15/2009
Revision 19:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 711 Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
The facsimile seal a ppearing was authorized by Robert
Florida Registration No. 59166, Florida DCAANE1983 Nieminen. P.E. on 12/16(2020. This does not serve as
CERTIFICATION OF INDEPENDENCE: an electronically signed document.
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, R.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 MEMO ETC, LLC
ROOFING COMPONENT EVALUATION: ONEMO I etc.
r•
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 7" Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
Section
1504.3.1
Property
Standard
Year
1504.3.1
Wind resistance
Wind resistance
FM 4474
2011
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
UL 1897
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
2015
1507.3.3 / R905.3,3
1507.11.2 / R905.11.2
Material standard
Material standard
FRSA/TRI, Sixth Edition
2018
TAS 110
Accelerated Weathering
ASTM D6163
ASTM D4798
2015
2011
Ent"
ERD (TST6049)
Examination�
Wind Resistance
Reference
Date
ERD (TST6049)
ASTM D1970 TAS 110 QC
/ ( )
2778.0.03.
531370.03.10-1-R1
04/07/2010
ERD (TST6049
ERD (TST6049)
FRSA/TRI04-12(OH)
S11150.05.09-R2
04/07/2010
10105/2010
ERD (TST6049)
ASTM D1970 (OH)
ASTM D1970 (MS)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 MS
S37210.12.11
12/01/2011
ERD (TST6049)
FRSAJTR104-12 MS )
S40540.02.13-1
02/19/2013
ERD (TST6049)
ASTM D1970 (BC)
S43530A2.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 ( QC)
544870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 OH
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
544870.04.14-4
04/10/2014
ERD (TST6049)
( )
Tensile Adhesion / Long Term Aging
S40540.10.14
SOPC-SC7645.02.15
10/31/2014
ERD (TST6049)
ERD (TST6049)
Accelerated Weathering g
50PC-SC8520.04.14
04/27/2015
0J/2015
M-D (CER1592)
Wind Resistance
HVHZ Compliance
SOPC-SC14045.05.17-R1
ICC-ES (EVL2396)
2015 IBC Compliance
3
06//28/201/2018
NEMO (TST6049)
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
ESR-1524
SOPC SC8970.08.1S-Rl
3/O017
04J5/2018
NEMO (TST6049)
Wind Resistance
ASTM D4798/D2970 OH & MS
( )
4-SOPC-18-003.08.18
08/27/2018
NEMO TST6049
(TST6049)
NEMO
Tensile Adhesion / Long Term Aging
4S-SOPC-18-002.05.19.A
4p-DOW-I9-SSLAP-01.A.R2
05/31/2019
(TST6049)
MEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
02/10/2020
03/12/2020
PRI (TST5878)
Peel adhesion (existing underlayments)
ASTM D1970 (MS)
4j-SOPC-20-SSUDL-01
12/
Soprema, Inc. (PDM3511)
Equivalency Declaration
SOP- 01
3/2013
16/29/205
LIL, LLC (QUA9625)
Quality Control
SA SMOOOTOT H PLY 40
0
J/201y
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
Florida BCIS
Current
MEMO ETC, LLC
Cert!/icate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R19
Soprema Roof Underiayments FL2569-RZI
Revision 19: 12/15/2020
Page 2 of 9
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14 1
4.15 f
4.16 7
Description
self -adhering, non -woven polyester fabric
Product
Material
Standard
Plant(s)
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
self -adhering, non -woven polyester fabric
Tri-Built S/A HT TU
Underlayment
ASTM D1970 and
Gulfport, MS
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
Lastobond Shield
ASTM D1970
Drummondville, QC
underlayment
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
self -adhering, woven polyethylene
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
40
surfaced, SBS
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
underlayment
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
two widths; 36 and 45 inch
self -adhering, woven polyethylene
surfaced, high
temperature, SBS modified bitumen roof
EnviroShield
ASTM D1970
Drummondville, QC
underlayment
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
Lastobond 195
ASTM D1970
Gulfport, MS
underlayment
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
Lastobond Eaves
Protection Sheet
ASTM D1970
Gulfport, MS
underlayment
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
Lastobond Eco
ASTM D1970
Drummondville, QC
underlayment
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Lastobond Smooth Seal
HT
ASTM D1970
Wadsworth, OH
Gulfport, MS
underlayment
self -adhering, glass -mat reinforced, film -
Wadsworth, OH
surfaced, SBS modified bitumen roof
Fri -Built Smooth HT S/A
Jnderlayment
ASTM D1970
Gulfport, MS
underlayment
self -adhering, glass -mat reinforced, film-
Wadsworth, OH
surfaced, SBS modified bitumen roof
IrimeSource Grip -Rite
imooth Seal HT
ASTM D1970
Gulfport, MS
underlayment
self -adhering, glass -mat reinforced, film-
Wadsworth, OH
surfaced, SBS modified bitumen roof
IESISTO L81236
ASTM D1970
Drummondville, QC
underlayment
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RI -BUILT Sand-R SA
hingle Underlayment
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R19
Soprema Roof Underlayments F1.2569-1121
Revision 19: 12/15/2020
Page 3 of 9
4.17
4.18
I
I
4.19
4.20
n(4 Kit— . — 0 — - —
—
Product
Material
— ®@L.fiYFiJ l C;L
Standard
Plant(Sj
Description
PrimeSource Grip -Rite
Eave & Valley Protector
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
WATER DEFENDER
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Colphene FR GR
ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC5ectivn: 1507.2 1507.3 1307.4 & 1507.5 1507.7 1507.8 & 1507.9
Asphalt clay and Concrete Tile Metal State or
underlayment Mechanical Adhesive- Wood Shakes or
Shingles Panels Shingles Slate -Type Shingles
Attach Set Shingles g
Lastobond TU HT, Tri-Built 5/A HTTU
underlayment Yes Yes Yes Yes Yes
See 5.6.1 Yes Yes (joint strips, 1507,1.1.3/
Lastobond Shield, Pro HT-N, RESISTO SA R905.1.1.3)
SMOOTH PLY 40 Yes No No No No Yes Yes
(joint strips, 1507.1.1.3 /
R905.1, 1.3)
Lastobond Shield HT, Pro HT-5 Yes No Yes
No Yes Yes Yes
(joint strips, 1507.1.1.3
R905.1.1.3)
EnviraShieid yes No Yes
No Yes Yes Yes
(joint strips, 1507.1.1.3 /
Lastobond Eaves Protection Sheet, R905.1.13)
Lastobond 195 Yes No No No No Yes Yes
(jointstrips, 1507.1.1.3 /
R905.1.1.3)
NEMO ETC, LLC
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVAWA€ION Evaluation Report S18010.06.09-R19
Soprema Roof Underlayments FL2569-R21
Revision 19: 12/15/2020
Page 4 of 9
(NNEMOjetc.
TABLE 1: ROOF COVER OPTIONS
FBC Sectlon: 1507.2 1507.3 1507.4 & 1507.5 1507.7 15028 & 1507.9
Underlayment
Asphalt clay and Concrete Tile Metal Slate or
Mechanical Adhesive- Wood Shakes or
Slate -Type
Shingles Panels Shingles
Attach Set Shingles Shingles
Lastobond ECO, RESISTO LB1236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector, Yes No No No Yes
TopShield ICE & WATER DEFENDER, NO Yes (joint strips, 1507.1.1.3/
RESISTO LB1244 R905.2.1.3)
Lastobond Smooth Sea[ HT, Tri-Built
Smooth HT S/A Underlayment, Grip -Rite Yes No No Yes
Smooth Seal HT Yes Yes:TUoint
trips, I507.1.13 /
R905.1,i.3}
Coiphene FR GR Yes Yes No No NoYes
trips, 507.1.1.3 /
R905.i.1.3j
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
Lastobond TU HT, Tri-Built S/A Dupont "Tile Bond— Roof Tile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants "Polyset® AH-160"
_ FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE
OPTIONS
FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to
meet wind loads for project)
Type
Primer
Material(s)
Lastobond Shield, Lastobond Pro
plywood, OSB or Southern Yellow Pine
HT-N, RESISTO SA SMOOTH PLY
Deck J
(Optional) ASTM
D41, Elastocol Stick,
40, Lastobond Shield HT,
sheathing
Elastocol Stick Zero
(SYP)
Lastobond Pro HT-S,
i EnviroShield, Lastobond TU HT,
ASTM D41
structural concrete
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Underlayment, Lastobond Eaves
Stick Zero
Fiber Roof Board
Protection Sheet, Lastobond 195,
Lastobond
Lastobond ECO, RESISTO LB1236,
self-
Sand-R SA Shingle
adhering
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
WATER DEFENDER, RESISTO
Base Sheet
(Optional) Elastocol
Stick Zero
ASTM D226, Type 11 felt or Modified Sopra-
LB1244, Lastobond Smooth Seal
G
HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
I
Deck j
(Optional) ASTM
Plywood
ywood
sheathing
Coiphene FR GR
self
ASTM D41
structural concrete
adhering
Insulation
(Optional) Elastocol
Dens Deck Prime or SECU ROCK Gypsum -
Stick Zero
Fiber Roof Board
Base Sheet
(Optional) Efastocoi
ASTM D226, Type 11 felt or Modified Sopra-
Stick Zero
G
I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEIVIO ETC, LLC
Certificate of Authorization #32455 7T"EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R19
Soprema Roof Underlayments Fl/15 202
Revision 19: Y2(15J2020
Page 5 of 9
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type
Primer
Material(s)
Lastobond TU HT, Tri-Built S/A HT
I
TU Underlayment, RESISTO
f LB1236, TRI-BUILT Sand-R SA
self-
Existing
RESISTO EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
I Shingle Underlayment, Grip -Rite
adhering
substrate
PRIMER
mineral -surfaced or film -surfaced roof
Eave & Valley Protector or
underlayment*
TopShield ICE & WATER
DEFENDER
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT, Tri-Built s/A HT
TU Underlayment, RESISTO LB1236, TRi-BUILT Sand-R SA Shingle Underlayment; Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Instrallation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 _Maximum Design Pressure = -45 0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67 5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction,
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
MEMO ETC, LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization ##32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
#3 Maximum Design Pressure = -120 0 psf: 01NEM01etc.
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
44 Maximum Design Pressure = -150 0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSAJTRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60 0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO L61236, TRI-
installation Type Exposure (days)
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE Mechanically
& WATER DEFENDER or RESISTO LB1244 attached 30
Lastobond TU HT, Tri-Built S/A HT TU Underlayment Adhesive -set tile roof
system 30
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Mechanically
Underlayment or Grip -Rite Smooth Seal HT attached 90
Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically
attached 180
NEMO ETC, LLC
Certificate of Authorization #32455 71" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 518010.06A9-R19
Soprema Roof Underiayments FL /22
Revision 19: 22/1J15J2020
Page 7 of 9
(NNEMOletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method
Maximum Scope
Flat
Max.10-tile stack
Lugged
Max..12
ax. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
Lastobond TU HT, Tri-
Built SJA HT TU
l
Underlayment
Lugged
r
Max.10-tile stack
Colphene FR GR
Flat
5:12
Lugged
Max. 10-tile stack
6:12
� 0
6.1 Soprema Roof Underlayments shalt be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Built SJA HT TU Underlayment, Lastobond ShieldLastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, ,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO L61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or F8C Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
MEMO ETC, LLC
Certificate ofAuthorizatian #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R19
Soprema Roof Underla FL
yments Revision 19: 12f /1 is/202/2020
Page 8 of 9
6.3.2 Tile Applications:
t#NEMOjetc.
Limited to Lastobond TU HT, Tri-Built S/A HTTU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
As required by the Building Official or Authority Having Jurisdictionooperly evaluate the installation of this
product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC—QUA9625; (314) 578-3406; k.chanceilor@us.ui.com
- END OF EVALUATION REPORT -
NEW ETC, LLC
Certtftcote of Authorization #32455 7"" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R19
Soprema Roof Underlayments FL2569-R21
Revision 19:12/1S/2020
Page 9 of 9