BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
03/31 /2022 Permit #: 2102-0148
Contractor:
DELAHUNTY CONSTRUCTION & CUSTOM HOMES, LLC
Job Address: 10851 S PCEAN DRIVE UNIT 89 JENSEN BEACH FLORIDA, 34957
Construction: ( Ll New Construction — Complete ( ) Existing — After Addition
House Infiltration Test esuits SLC Climate Zone 2
CFM (50) _
Volume =yj
ACH (50) = CFM (50) x 60 / Volume = _
Passing results must be & ACH (50) or less
Test Date* l
Mec onical Ventilation required less than 3 ACH
(Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489,105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company ECO-INNOVATIVE LLC
Company Name:
Address: 10570 S US HWY 1, STE 300, PORT ST LUCE, FL 34952
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordancg wit cR402.4.1.2 Climate Zone 2.
Signature:
Printed Name: KATHLEEN CONNOLLY
License/Certification #: 5060036