Loading...
HomeMy WebLinkAboutENERGY CALCS & MANUAL J - 30 CALLE DE LAGOSFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit !Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�l442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= ft2 11. Ceiling Types (1476.0 sgft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(141.3 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl, U=1.04 101.25 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14. Heating systems kStu/hr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1445.5 sgft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.098 Total Proposed Modified Loads: 44.57 PASS Total Baseline Loads: 45.19 1 hereby certify that the plans and specifications covered by Review of the plans and��� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance rl+ with the Florida Energy Code. ' �=3` ��• 'rp PREPAR D Y' Before construction is completed r # G DATE' '�'zo2 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energyi ode.'t9,p was OWNERI T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2). 1/12/2021 12:02 PM EnergyGauge(D USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 301 ft' ---_ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ---_ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ---_ 0 1 0 5SIab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ---_ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _--_ 0 1 0 1/12/2021 12:02 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft' ---- 0 1 0 98Iab-On-Grade Edge lnsulatio GREAT/DINING 46ft 0 488 ft' --_- 0 1 0 ROOF _ / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 W 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block - Int InsrBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int Insu6EDROOM 4.1 28 0 8 0 224.0 ft' 0 0 0.4 0 3 NW=>SE Exterior Concrete Block - Int InsuBEDR00M 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 a 0 64.0 ft' 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InsREDROOM 2 4.1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Int InsREDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int Ins8EDRGGM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Int InsSIEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 a 0 8.0 ft' 0 0 0.4 0 _12 SW=>NE Exterior Concrete Block - IntlnsuLAUNDRY 4.1 6 0 8 0 48.0ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int lnst6REAT/DINT 4.1 26 0 8 0 208.0 ft' 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstBREAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT Sl1MMORV rWFr fI IQT 1211=112nl2T WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft- 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.611' WINDOWS Orientation shown Is the entered orientation => chanced to Worst Case. Wall V # Ornt ID Frame Overhang Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal _ 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE 14 Metal Low-E Single Yes 1.04 0.29 Y 32.9 ft° 1 ft 0 in 1 ft5ln Low-E Single Yes 1.04 0.29 Y 6.9 IV 1 ft 0 in 1 ft5In Low-E Single Yes 1.04 0.29 Y 24.0 ft' 6 ft 0 in 1 ft 5 in Low-E Single Yes 1.04 0.29 Y 37.5 V 1 ft 0 in 1 ft5ln Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 In 1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft- 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Seed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBlulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use Se1Pm Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT RIIMMARV rWl=rtkl ICT wGnnwT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre,Thermostat: Ceiling Fans: 'jN Heating Jan Feb r[ Mar € X� Jun E ]Jul (X� [ ]Aug rX� [ [ ] ]Sep L 1 Oct Nov Nov Dee € Venting [ 1 Jan O Feb l l l l (Xl Mar lhl Apr May Jun [ 1 Jul [ 1 Aug [ 1 Sep lXl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Healing (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft. Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 it 0.3 WIC Default(B Ibs/sq.ft. ft2 it 0.3 M. BATH Default(8 lbs/sq.ft, ft2 it 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 it 0.3 BATH Default(8 lbs/sq.ft. ft2 it 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 it 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft2 it 0.3 GREAT/DINING 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FIsRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barter. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures Installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall .�.nd h.hind pining and wiring Shower/tub The air barrier Installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phons box or The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill volds a. In addition, inspection of log walls shall be in accordance vnth the provisions of ICC-400. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 11. Ceiling Type and Insulation level Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area (ft') 1446 b. Knee Wall (Vented) R=19.0 30.00 ft' 7. Windows" Description Area c. N/A R= ft' a. U-Factor: Sgl, U=1.04 101.25 ft' 12. Ducts, location & Insulation level R ft' SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 b. U-Factor: Sgl, U=1.11 40.00 ft' SHGC: SHGC=0.27 13. Cooling systems kBlulhr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. N/A ft' SHGC: H SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft' a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' Credits (Performance method) None b. N/A R= ft' c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. .. Builder Signature: �' Date: Address of New Home: 30 ZA WK -\%>Z\-A 901G City/FL Zip: 7 `- RS \ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wriphtsoft° Project Summary J Entire House By. QUICK CALCS, INC. 317 SL LUCIE LN., Fr. PIERCE, FL 34946 Pivre: 772-466-6799 Fax 772466-6796 Emit: QUICKCALCS AOL.COM For: WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL Notes: Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Insidedb 70 OF Inside do 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Duds 5900 Btuh Duds 8919 Buh Central vent (0 cfm) 0 Btuh Central vent (0 cf n) 0 Btuh (none) (none) Humidification 0 Stuh Blower 0 Btuh Piping 0 Btuh Equipmentload 25591 Btuh Use manufacturers data n Rate/swingg multipplier Equipmentsensibleload 0.95 Infiltration 24418 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Btuh Duds 2429 Btuh Central vent (0 cfm) 0 Btuh Heath Coolingg (none) Area (tt=) 1602 1602 Equipment latent load 4493 Btuh Volume (flo) 14827 14827 Airchan Whour 0.38 EquivA94 0.20 49 Equipment Total LoadSen+Lat) Re. 8 28912 Btuh MIT) SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carver Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIRCONDITIONING Model 25HBC536AO30 Cond 25HBC536AO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Effidency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latent000ling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actualairflow 1160 chm Actual air flow 1160 cfm Airflowfador 0.045 cfm/Btuh Airflowfador 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=7kW, Output =23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed 'r wri htso• 2021-Jarv121294:36 t.' Wn%oft FNAC\WYNNE-TH•w*-+�ft+�+ RigIt-Sine® Uriversal 201919,021 RSM8101 Pagel Ak.:(l� ... \gE GRAND CARLIONRp Calc=W8 Frort Doorfams: N wrghtsofr Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.. LUCIE UN„ FL PIERCE, FL 34946 Phone: 772466-6799 Fax 772A66-6796 Email: QUICKCALCS a�i OL,COM 1 Room name Enh're House BEDROOM 2 E)posedvall 1762 ft 41.0 ft 3 Room height 9.3 ft d 8.0 ft heaVcool 4 Room dimensions 14.0 x 18.0 ft 5 Room area 1601.5 ft2 252.0 ft2 Ty Constudon U-value Or HTM Area Load s (" Load number (BWhW--'F) (BWh4t°) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 13A4= 0.143 ne 4.00 2.55 551 513 2055 1306 72 72 - 288 - 183 1Acton 1270 ne 35.56 70.43 38 0 1344 2662 0 0 0 -0 13A4ocs 0.143 se 4.00 2.55 128 87 348 221 0 0 0 0 tAclom 1270 se 35,56 70.95 20 0 711 1419 0 0 0 0 11 11DO 0.390 se 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 13A4os 0,143 9n2 4.00 2.55 416 390 1562 993 144 144 577 367 G lWon 1270 sv 35,56 70.95 6 0 213 426 0 0 0 0 1Arotom 1270 av 35M 70.95 20 0 711 1419 0 0 0 0 YY��11 13A4os 0.143 nw 4.00 2.55 352 288 1151 732 112 88 354 225 1-G 1Aclon 1270 nw 35.56 4524 12 0 415 528 12 0 416 528 1Aclorn 1270 nw 35.56 4524 12 0 427 543 12 0 427 543 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P 12C-0sx 0.091 - 2.55 128 120 120 306 154 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 1602 1602 1435 3715 252 252 226 w F 22A-tpl 0.989 - 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)AED exarsion 23 197 Envelope L-digain 16802 15970 3421 2627 12 a) Infilbalon 2890 815 640 180 b) Roommantilafion 0 0 0 0 13 Internal gains: Omlpanls@ 230 0 0 6 0 ApplianoaJolher 0 1 0 Subtotal (11nes6to 13) 19691 16785 4061 2807 Less exlemal load 0 0 0 0 Lesstrander 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19691 16785 4061 2807 15 Ductloads 30% 53% 5900 8919 300A 53% 1217 1491 Total room load 25591 25704 5278 4298 Air required(dm) 1160 1160 239 194 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. =j MtiBO/'C^ 2021-Jar,121294:36 " ""`"""""""° Ri9H-Sute6Jlhiversal 201919.021 RSU08101 ...Hs1Wd91-fsoft WAC1WYNNE-THE GRAND CARLTON.np CaIc=M78 FrorRWortzces: N Page -� wrightsofr RighW@ Worksheet Job: Entire House Date: By.QUICK CALCS, INC. 317 ST LUCIE LN., Fr. PIERCE, FL 34946 Phow 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name WIC MASTER BATH 2 FVosedxall 0 ft 17,0 ft 3 Room height 8.0 ft heaV=1 8.0 It hea%mol 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 7F 7.0 x 17.0 ft 119.0 w Ty Construction U-value Or HTM Area (W) Load Area (W) Load number (BWh4P--°F) (BWh4P) or penmeter (ft) (BWh) or perimeter (ft) (BWh) Heat T Cool Gross N/Pro Heat Cool Gross NVP/S Heat Cool 6 W, 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 - 0 0 0 -G 1Aclw 13A-4ocs 1270 OAQ ne se 36.56 4.00 70.43 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 11 tAclan 11DO 1270 0.390 se se, 35.56 10.92 70.95 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W �l ♦-G 13A-4ocs 13A4as 0.143 0.143 a sw 4.00 4.00 2,55 2.55 0 0 0 0 0 0 0 0 0 136 0 130 0 521 0 331 1Ac1an 1270 six 35.66 70.95 0 0 0 0 6 0 213 426 �-G 1A-clom 1270 sx 35.56 70.95 0 0 0 0 0 0 0 0 13A-4= 0.143 nw 4.00 2.55 0 0 0 0 0 0- 0 0 IA-olw 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 1Ao1om 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4AS-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 119 119 107 276 F 22A-ml 0.989 - 27.69 0.00 63 0 0 0 119 17 471 0 6 c)AED e=rsion -13 55 Envelopeloss/gain 56 133 1311 1087 12 a) Infiltration 0 0 265 75 b) Roomvenflation 0 0 0 0 13 Internal gains: Ocwpants@ 230 0 0 0 0 Appliance-9/other 0 0 Subtotal (lines 6to 13) 56 133 1577 1162 Lessextemalload 0 0 0 0 Lose; Mnsier 0 0 0 0 Redistribulon 0 0 0 0 14 Subtotal 56 733 1577 1162 15 Dud toads 30% 53% 17 71 30% 53% 472 618 Total room load 73 204 2049 1780 Air requi11(dm) 3 9 93 80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr79M[a4M. 2021-Jan1212:04:36 . A Rigtt-Sate@ Uriversal 201919.021 RSUD8101 Paga2 ...rtAWnghsoft HVAC\WYNNE-THE GRAND CARLTON.rup CaIc=W8 FrortDoorfaces: N wrightsoft' Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Plow 772-466-6799 Fan 772-4666796 Emil: QUICKCALCS@AOL COM 1 Room name KITCHEN BATH oosedwall Oft 5.0 It 3 Room om Wght 8.0 It heaYbool 9.4 R hwVcool 4 Room dimensions 1.0 x 192.0 R 9.0 x 5.0 It 5 Room area 192.0 W 45.0 W Ty Construction U-value Or HTM Area (et Load Area (W) Load number (BWhM'--°� (fiWh4V) or perimeter (ft) (BWh) or perimeter (fl) (BWh) Heat Cool Gross N/PS Heat Cool Grass NrP/S Heat Cool 6 W 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 41 41 188 120 �-G 1Aalom 1270 re 35.56 70.43 0 0 0 0 0 0 0 -0 13A-0as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 70.95 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4os 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 IN 13A-4= 0.143 av 4.00 2.55 0 0 0 0 0 0 0 0 IA -clan 1270 su 35.56 70.95 0 0 0 0 0 0 0 0 1Aclom 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 13A-4os 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 nw 35.56 4524 0 0 0 0 0 0 0 - 0 to -atom 1270 nw -35,56 4524 0 0 0 0 0 0 - 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 - 0 0 - 0 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 192 192 172 445 45 45 40 104 F 22A-tol 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AEDemrsion -39 -22 Envelopeloss/gain 172 406 367 202 12 a) Infiltnoon 0 0 92 26 b) Roomventlation 0 0 0 0 13 Intemalgains: O=pants@ 230 0 0 0 0 Appliancesrolher 0 0 Subtotal (lines 6 m 13) 172 406 459 228 Less enamel load 0 0 0 0 Lesstanser 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 172 406 459 228 15 Duct loads 30°% 53% 52 216 30% 53% 137 121 ToaI- room load 224 622 598 349 Air ruired(c8n) 10 28 27 16 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wr!lall solR^ 20214arvl 212A4:36 C Ak RIgH-Sine® Un.raal 201919.021 RSU08101 Page ...rtsftngttsofl WACWYNNE-THE GRAND CARL10N.np Calc=NU8 FrontDoorfaces: N wrightsoW Right -A) Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN.,Fr..PIERCE, FL34946 Phore: 772466-6799 Faz772A66-6796 Email:OUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 Exposdwall 302 ft 6.0 ft 3 Room height 8.0 ft heaV000l 8.0 ft heatbool 4 Room dimensions 1.0 x 190.5 A 6.0 x 10.0 ft 5 Room area 190.5 ft' 60.D ff Ty Consbuc4'on U-value Or HTM Area (fl°) Load AM (ft') Load number (BtiWF) (BbrhW) or perimeter (ft) (BWh) or perimeter (ft) (Bbih) Heat Cool Gros NIPS Heat Cod Gross NIPS Heat Cool 6 VL-G 13A-0as 0.143 ne 4.00 2.55 120 120 480 305 0 0 0 0 1Ac1om - 1270 re 35.56 70.43 0 0 0 0- 0 0 0 - 0 13A-4m 0.143 s 4.00 2.55 80 60 240 153 48 27 108 69 1Ac1om 1270 se 35.56 70.95 20 0 711 1419 0 0 0 0 11 1100 0.390 se 10.92 11.31 0 0 0 0 21 21 229 238 W 13A-0ars 0.143 a 4D0 2.55 34 34 136 86 0 0 -0 0 13A-0ps 0.143 sw 4.00 2.55 8 8 32 20 0 0 0 0 1Ac1w 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 1Aciom 1270 sw 35.66 70.95 0 0 0 0 0 0 0 0 13A-4ors 0.143 nw 4.00 2.55 0 0 0 0 0 0 0- 0 1Ac1am 1270 nw 3556 4524 0 0 0 0 0 0 0 - 0 1Ac1om 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4AS2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-O w 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 191 191 171 442 60 60 64 139 F 22A-tpl 0.989 - 27.69 0.00 191 30 835 0 60 6 166 0 6 c)AFD exwrsion 209 41 Envelope lossIgain 2606 2635 1 657 404 12 a) Infiltrafion 472 133 94 26 b) Roommenblabon 0 0 0 0 13 Internal gaim O=panta@ 230 0 0 0 0 Applianowolher 0 1 0 Subtotal (lines 6to 13) 3078 1768 651 430 Leas extamal load 0 0 0 0 LesbanSer 0 0 0 0 Redistrbution 0 0 0 0 14 Subtotal 3078 2768 651 430 15 Dud loads 30% 53% 922 1471 309% 53% 195 229 Total room load 1 4000 4239 846 659 Air required(dm) 181 191 38 30 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021-JaM21204:36 RiGRAN C RLTD .rup C19.021 From o Page ...ds\WdgFLmfl HVACiWYNNE-THE GRAND CARLTON np Calc=MIB Frort �orfaces: N wrightsoft° Right,J® Worksheet Job: Entire House Date: QUICK CALCS, INC. ey. 317 ST. LUCIE LN, Fr. PIERCE, FL 34946 Ptone:772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM 1 Room name LAUNDRY GREAT/DINING 2 Exposedmll 6.0 ft 46.0 IT 3 Room height 8.0 a ImV000l 12.0 It heat1=1 4 Room dimensons 7.0 x 6.0 It 1.0 x 488.0 It 5 Room area 42.0 IF 4B8.0 IF Ty Construction U-value Or HTM Area Load Area (ft) Load number (Bbh4F--°F) (Bbh4F) or perimeter (11) (Bhih) or perimeter (ft) (BNh) Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13AA= 0.143 ne 4.00 2.55 0 0 0 0 312 274 1098 698 t-G 1Aclom 1270 na 36.56 70.43 0 0 0 0 38 0 1344 2662 13A-4= 0.143 se 4.00 2,55 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 70,95 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 134-4as 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 W 13A-4ors 0.143 sx 4.00 2.55 48 48 192 122 0 0 0 0 1Aclom 1270 ex 35.56 70.95 0 0 0 0 0 0 0 0 1Ac1an 1270 sw 35.56 70.95 0 0 0 0 0 0 0 0 UUU���111 13A-4= 0,143 nw 4.00 2.55 0 0 0 0 240 199 798 507 4---G 1Aciom 1270 nw 35M 4524 0 0 0 0 0 0 0 0 IL-f; lWom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 G 4A5-2=d 0.770 nw 21.56 36.90 0 a 0 0 41 0 880 1505 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-bl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 0)AED ew sion -22 1 -597 Envelope lose/gain 396 198 58W 5908 12 a) Infilbaion 94 26 1077 304 b) Rcom Ienblabon 0 0 0 0 13 Intemalgais: O=pants@ 230 0 0 0 0 Applianmsblher 0 0 Subtotal(Vnes 6b 13) 490 224 6907 6212 Leese)d9mal load 0 0 0 0 LestranSer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 490 224 6907 6212 15 Ductloads 30% 539/6 147 119 30% 53% 2070i 3301 Total room bad 636 344 8977 9512 Air required(rim) 29 16 407 429 Calculations approved byACCAto meet all requirements of Manual J 8th Ed , -rw v!!, r�ft+>��` 2021-Jarv1212:04:36 105A Rigtt-SUte®UHv rwl201919.021 RSU08101 Page 5 ...rtsm6gttsoft HVAC\WYNNE-THE GRAND CARLTON rtp Calc=WII FrontDoorfaces: N wrightsoft- Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317ST. LUCIE LN-Fr..PIERCE, FL 34946 P1ure: 772466.6799 Fax: 77246M796 Email: QUICKGALCS AOL.COM 1 Room name BEDROOM3 2 Exposdwall 25.0 it 3 Room height 8.0 ft heaVmol 4 Roomdimensions 15.0 x 10.0 a 5 Room area 150G ft' Ty Construction U-slue Or HTM Area M) Load Area Load number (BWhM'---F) (BWIM') or perimeter (ft) (BWh) or perimeter Heat Cool Gros NrPS Heat Cool Gross tN/PIS Heat Cool 6 VN 13A-4m 0.143 ne 4.00 2.55 0 0 0 - 0 I-G 1Aclom 1270 ne 35.56 70.43 0 0 0 0 V+1 13A-4ors 0.143 se 4.00 2.5E 0 0 0 0 L--G tAclan 1270 % 35.56 70.950 0 0 0 11 11D0 0.390 se 10.82 11.31 0 0 0 0 w 13AA003 0.143 s 4.00 2.55 0 0 0 0 13A4o s 0.143 sw 4.00 2.55 80 60 240 153 1Aclom 1270 sw 35.56 70.95 0 0 0 0 lWom 1270 sw 35.56 70.95 20 0 711 1419 V+/ 13A-0as nw 0 0 0 0 1Aclorn 1270 1270 nw 3556 556 524 4624 0 0 0 0 tAclon 1270 nw 4524 0 0 0 0 LEI--(G' G 4A5-2omd 0.770 nw 21.56 21.56 36.90 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 120 120 306 154 c 16A-30md 0.032 - 0.90 2.32 150 150 134 348 F 22A-tnl 0.989 - 27.69 0.00 150 25 692 0 6 c)AEDe rson 296 Envelope loss/gain 2084 2369 12 a) Infiltraton 156 44 b) Roomventlation 0 0 13 Internal gains: Cc upants oQ 230 0 0 Applla ooslother 0 Subtotal(lines6b13) 2240 2413 Les external load 0 C Lesiransier 0 0 Redistribution 0 0 14 Subtotal 2240 2413 15 Ductloads 30% 53% 671 1282 Toal room load 2911 3695 Airrequired(cfm) 132 167 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. I -r w w !r[soT[^ 2021-Jan1212L4:36 """-"""'-' RigitSdte®Uriversal 201919.021 RSU08101 ...rtsXWrighIso1HVAQWYNNE-THE GRAND CARLTON.np Calc=W8 Front Doorfaws: N Page