HomeMy WebLinkAbout5v metal ma pa BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts i Publications Contact Us BCIS Site Map Links Search
to id
r
Product Approval
� USER:Public User
Product Approval Menu>Product or Application Search>Application List
7770�
FL# FL31652-RI
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Metal Alliance Inc.
Address/Phone/Email 2120 SW Poma Dr.
Palm City, FL 34990
(844) 638-2548
orders@metalalliance.com
Authorized Signature Tara Faulkner
orders@metalalliance.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 05/06/2029
Validated By James R Wally, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL31652 R1 COI 26ga 5V plywood.pdf
Referenced Standard and Year(of Standard) Standard
Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/11/2020
Date Validated 08/13/2020
Date Pending FBC Approval 08/20/2020
Date Approved 10/13/2020
Summary of Products
F Model, um �C&nimp
me escription
31652.1 O1: 50ALLV 5V6ga T ��ood
V 5V Crimp panel from 26ga (min) on 15/32" (min)
i or 3/4" (min) wood plank
Li of Use _ i Installation Instructions
Approved or u�i �: s FL31652 R1 II 26ga 5V plywood.pdf
j Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
i Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-206 Evaluation Reports
Other: 206psf with 12"-12" pattern @ 8"oc, 117.75psf @ 16" ( FL31652 Rl AE 26ga 5V plywood.pdf
Created by Independent Third Party: Yes
31652.2 02: 50ALLV 5V Crimp 032 Aluminum 50ALLV 5V Crimp panel from nominal 0.032" aluminum or
thicker on 15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL31652 Rl II 32AI 5V plywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-183.5 i Evaluation Reports
Other: 183.5psf with 12"-12" pattern @ 12"oc, 116.25psf @ ; FL31652 Rl AE 32AI 5V plywood.pdf
16"oc Created by Independent Third Party: Yes
31652.3 03: 50ALLV 5V Crimp 26ga 50ALLV 5V Crimp panel from 26ga (min)on 15/32" (min)
plywood or 3J4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL31652 Rl II 26ga 5V plywood-nonHVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-206 Evaluation Reports
Other: 206psf with 12"-12" pattern @ 8"oc, 101psf @ 16" oc FL31652 R1 AE 26ga 5V plywood-nonHVHZ.pdf
Created by Independent Third Party: Yes
31652.4 04: 50ALLV 5V Crimp 032 Aluminum 50ALLV 5V Crimp panel from nominal 0.032" aluminum or
thicker on 15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL31652 R1 II 32AI 5V plywood-nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-183.5 }Evaluation Reports
Other: 183.5psf with 12"-12" pattern @ 12"oc 1 FL31652 Rl AE 32AI 5V plywood-nonHVHZ.pdf
Created by Independent Third Party:Yes
31652.5 05: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75" Corrugated panels from 26ga(min) on 2x4
(nom) battens
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL31652 R1 II 26ga 50AIICor battens-nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: 161psf with fastener every peak, 101psf with fastener I FL31652 Rl AE 26ga 50AIICor battens-nonHVHZ.pdf
every other peak, battens @ 24" Created by Independent Third Party: Yes
31652.6 06: 50ALLCOR Corrugated 26ga 50ALLCOR 0.75"Corrugated panels from 26ga(min) on 15/32"
(min) plywood or 3/4" (min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL31652 Rl II 26ga 50AIICor piywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161 Evaluation Reports
Other: 161psf with fastener every other peak @ 12"oc, 101 FL31652 R1 AE 269a 50AIICor plywood.pdf
psf @ 16"oc Created by Independent Third Party: Yes
Sack f± t
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.�opyriaht 2007 2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395,*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
E
Credit Card
Safe
METAULLIANCE
A Value Added Supplier of Metals
26ga 5V Crimp Panels
26ga (min) 5V Crimp exposed fastener panel over 15/32"
(min) plywood
Metal Alliance, Inc
2120 SW Poma Dr I Palm City FL 34990
Produced by Metal Alliance's Network of Approved Regional Manufacturers
Product Description
Exposed fastener 5V-style panel with a 24" coverage and a nominal rib
height of 0.375"
Product Material
26ga (min) steel
26ga is nominally 0.0185" with yield strength of at least 50ksi, and shall be corrosion
resistant per FBC 1507.4.3 where required.
Fastener
#10 1.5-inch fastener with sealing washer
Nominally 12"-12" fastener pattern
Fasteners compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
���ttllll�,
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL * � •
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
No.81377
STATE OF [(�
CORIDA
NAL
1rlttlt v
50ALLV 2020. E Eng
07:44:57-04'00'
This item has been digitally signed and seated
5V CRIMP 26GA by D.E.Eng,PE,on the date indicated.Printed
copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required.
Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511/1521, provided the existing roof meets the conditions required
by the applicable code.
Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required.
79
m Allowable Loads & Installation Requirements:
(Metho . #10 x 1.5" fasteners in 12"-12" pattern at 16" o c • 117.75 PSF
Me ht od B: #10 x 1.5" fasteners in 12"-12" pattern at 8" o c . 206 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the TAS 125 / UL 580 standard by Intertek Testing (TST-1527),
report J6368.19-450-44 RO and to TAS 100 under report J6368.06-450-44 RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2
(non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
• TAS 125 - Standard Requirements for Metal Roofing Systems
• TAS 100 - Wind and wind-Driven Rain
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any
company manufacturing or distributing products under this evaluation. The same entities do
not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be
completed by others. Fire classification and shear diaphragm design are outside the scope of
this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as
required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible
for any conclusions, interpretations, or designs made by others based on this evaluation
report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no
express or implied warranty regarding performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use
of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
MEIA '
A Value Added Supplier of Metals
ENGINEERING LOAD TABLES
Instructions: �, a
Select the appropriate load table that applies to a- 2 2
the structure in question, 3
ti
Determine the design wind speed for the project \ 2,� 1 1 2
location. 2 \
Use the attachment method indicated for that 2 1 2 2 3 —
windspeed within each roof zone. 2-- - 2 3 t o
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone ;2 1
1 2
concept. For the load tables below, the worst case f i
was taken for each zone and reported using the a 2
standard zones 1-2-3: —2 -
3 a
Zone 1 includes zones 1 and 1' �-�ai HIP ROOF GABLE ROOF --IaL
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3 e and 3 r a:10%OF LEAST HOIZONTAL DIMENSION OR 04h,WHICHEVER IS SMALLER,BUT NOT
LESS THAN EITHER 4%OF LEAST HORIZONTAL DIMENSION OR 3FT(0.9M).
Combining these zones creates a clear, simple OR AS DETERMINED 8Y DESIGN OR OTHER APPLICABLE CODE"
scheme, at the expense of some design efficiency. ROOF ZONES FOR GENERIC BUILDING
Contact Metal Alliance Inc for further information,
or consult a licensed design professional.
METHOD A; 16" O.C. METHOD B: 8" O.C.
-------12" {NOM) 12" (NOM) i
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof,or gable/hip roof with max slope of 45° Have either a flat roof,or gable/hip roof with max slope of 45°
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL31652.,01: 26 a 50ALLV on 15132" 1 ood FL31652.01: 26 a 50ALLV on 15/32"2!Xwood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A B B
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A B g 'B
Zone 3: A A A A A A A A A 8 B Zone 3: A A A A A B B B B
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have either a flat roof less than 70,hip roof with Have either a flat roof less than 7°,hip roof with
max slope of 450,or gable roof with slope between 200 and 450 max slope of 450,or gable roof with slope between 200 and 450
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL31652.01: 26 a 50ALLV on 15/32" Plywood FL31652.01: 26 a 50ALLV on 15/32" P1 ood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A B
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A
B
Zone 3: A A A A A A A A A A B Zone 3: A A A A A B B g g
META' LALLIANCIA
_ A Value Added Supplier of Metals