Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3150 NORTH A1A-MECHANICAL SUBMITTAL
M-SE _ IES SUBMITTAL DATA: i i & i i MITSUBISHI (' BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM AIFW ELECTRIC Job Name: System Reference: Date: --..................................._............_.................................................................._...._.. -.................._...._.._............._............................................................__.........._....._...._....—............. ............. —..._...._..---.......................................--, Indoor Unit: Outdoor Unit: Wireless Remote Controller MSY-GL24NA I MUY-GL24NA ---..._..............—._..............................................................................................................._......_.... .. —{..........._............._........................................................................................................................................._.....__........ _..._...__............ jI sY'"3�py'��hk j I GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options:Quiet,Low,Medium,High,Super-high,Auto Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud®smart device app for remote access Third-party interface options -Wired or wireless controllers • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ( 1 I 1 Maximum Capacity Btu/h 31,400 Rated Capacity Btu/h 22,500 1 Minimum Capacity Btu/h 8,200 Maximum Power Input W I 3,522 Cooling -- --- --- - -- Rated Power Input W 1,800 - -- ---- Moisture Removal Pints/h 5.1 ! I Sensible Heat Factor 0.75 Power Factor % 99/99 SEER — 20.5 Efficiency EERY I 12.5 .............._.._....._.........._— ...._...._.......--......................_.__.................._...-..........._..._.._..- - ...._...- --._..._....._--..................-----........................................---.._-_..._........... ENERGY STAR®(ENERGY STAR products are third party certified by an EPA- YES recognized Certification Body.) Voltage,Phase,Frequency I 2081230V,1 phase,60Hz - ------- J Guaranteed Voltage Range V AC 187-253 Voltage:Indoor-Outdoor,S1-S2 V AC 208/230 :............_......—..— - -- —._...__.._._........_.__..........._.._......-- ----.-._......__...-- .... -._...-.__......_........ --.._._......._........._.-................. -_.........._..._; Electrical Voltage:Indoor-Outdoor,S2-S3 V DC 24 _..............- -. - - -.............._._......._._..._..._._......... _ .....----.._..-__.-._.._. Voltage:Indoor-Remote Controller 1 Wireless Type Recommended FuseBreaker Size A ---_^20 I Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A ! 1 MOCP A 15 Blower Motor Full Load Amperage A i 0.76 —.__...._.:._...:_..__._........................... ----._ ........ __..... ------------------- --.._.._..- ...--.....__..._-.._..._.._....---._...._......-.............. Blower Motor Output W 56 _...._......__......_............. — -- -.—..... -_.........._.........._.. .......----.................._..---------- ._................._............... - ---- Airflow Rate at Cooling,Dry CFM i 738-628-544-469-388 - Airflow Rate at Cooling,Wet CFM 661-562-487-420-347 Sound Pressure Level(Cooling) dB(A) 53-49-45-41-34 Drain Pipe Size In.(mm) 5/8(15.88) Indoor Unit Heat Exchanger Type Plate fin coil �--- -- - External Finish Color Munsell 1.OY 9.2/0.2� W: -5/16(1,100) In-(mm) 43 Unit Dimensions D:In.(mm) 9-3/8(238) - ---i --....-- _ - H:In.(mm)- �_ 12-13/16(325) - ---- W:In.(mm) 45-1/2(1,160) Package Dimensions D:In.(mm) 12-3/4(320) i -_ H:In.(mm) 15-1/2(390) Unit Weight Lbs.(kg) 37(17) Package Weight ......................_. ---- - -....._..........-.._....._.............- ._._.._..Lbs.(kg) __.......__........:..._37(17) f Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)" °F 90 DB,73 WB 167 DB,57 WB Temperature Range MCA A 17.1 -- � — ......._....... A 20_. Outdoor Unit MOCP I Fan Motor Full Load Amperage A 0.93 Specifications are subject to change without notice. 0 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. • MSY-GL24NAi a --......_... _ ...._.._..........._._......_..._. ---._._._._.....——._.—._.....__.... _......_.........--..............—....._...__..... —_._.__................ ----..... ...._.._.._... —......_..._...._..-- Fan Motor Output I W i 77 - I} Airflow Rate CFM 1,769 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil i-- Sound Pressure Level,Coolingi dB(A) 55 Compressor Type DC INVERTER-driven Compressor Model SNB172FQKMT - —...—.....---............... ------ --.._..� Compressor Rated Load Amps A 12.9 t ' Compressor Locked Rotor Amps A j 16.1 j Compressor Oil Type//Charge oz. FV50S//13.5 External Finish Color i Munsell 3Y 7.8/1/1 Base Pan Heater I N/A W:In.(mm) 33-1/16(840) Unit Dimensions D:In.(mm) 13(330) ............ _......._...----.._............_.--_........_............._..._..--•-_.._.._.-_...._............__._... H:In.(mm) 34-5/8(880) W In.(mm)—� 38-9/16(980) Package Dimensions D:In.(mm) 16-9/16(420) H:In.(mm) i 39(990) Unit Weight Lbs.(kg) 119(54) Package Weight Lbs.(kg) 139(63) ......_........_..........---._............................... -- --- -...--....... ....._..---...........................---- -- Outdoor Unit Operating Cooling Air Temp(Maximum/Minimum)* 'F j 115/14 Temperature Range _.- p g —i Cooling Thermal Lock-out/Re-start Temperatures- °F -4/0 Type ; R410A Refrigerant Charge Lbs,oz 4,3 Gas Pipe Size O.D.(Flared) In.(mm) 5/8(15.88) Liquid Pipe Size O.D.(Flared) In.(mm) 3/8(9.52) Piping j Maximum Piping Length Ft.(m) 100(30) Maximum Height Difference Ft.(m) 50(15) _._.—......._....._......----......----......_..........._...._..__._ -................ - - ---.._......_._.__ ..........._...._.......--..._ Maximum Number of Bends 10 -....----.............._...__..—_._...:--..........._.._............._-_............_........................._.....---........_...................._.....--..._......—. —. _..._..... _.........._.___—._..^_ ................._....._.. Notes — ................. _ -- - - ---- AHRI Rated Conditions Cooling(Indoor//Outdoor) "F 80 DB,67 WB//95 DB,75 WB (Rated data is determined at a fixed compressor speed) *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. -System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. i Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES- MSY-GL24NA Anti-allergy Enzyme Filter MAC-2310FT-E Backlit,Wall-mounted,Wireless Controller ❑MHKII Portable Central Controller MCCH1 Wired MA Controller' o PAR-33MAA Simple MA Controllers n PAC-YT53CRAU ..........-....................................... ......................................................................... ------_.______....._.......... Touch MA Controller' o PAR-CT01MAU-SB Wireless Temperature and Humidity Sensor o PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑most System Control Interface2 o MAC-3331F-E Wireless Interface PAC-USWHS002-WF-1 Thermostat Interface o PAC-US44 CN-1 kumo station® o PAC-WHS01HC-E ............ ............... ....................... ................ ...................................................... ——---------------- USNAP Interface ❑PAC-IMS01UP-E ----------------------------- .................... IT Extender ❑PAC-WHS01IE-E BACnet4D and MODBUSID Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB Blue Diamond Sensor Extension Cable—15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. C1 3-192 Blue Diamond MultiTank—collection tank for use with multiple pumps o C21-014 .................................................. .................. .............................................. Blue Diamond Rubber Foot Pads ❑F1 0-010 ........... Mini Condensate Pump-230 volt application oS130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835-110 to 250V ---------------------------1 --- MaxiBlue Advanced Blue Diamond Mini Condensate Pump wl Reservoir&Sensor(11 OV)up to 48,000 Btu/h ❑X87-711-11 OV [recommended] ......................................... Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] I o X87-721-2081230V ........................................................ ..................................... ............... ..................... MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 Btuth o X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit ❑T18-016 ------- ------- Drain Pan Level Sensor ❑DPLS2 (30A/600V/UL)[fits 2"X 4"utility box]-Black TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White ❑TAZ-MS303W Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. @ 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: MUY-GL24NA Air Outlet Guide MAC-886SG-E Drain Socket o MAC-860DS Hail Guard o HG-A7 Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic j o DSD-400P Condensing Unit Mounting Pad 16"x 36"x 3" ❑ULTRILITE1 ............................................................................___......... ........... .......................... ............. ................... .......... Outdoor Unit Stand 12"High QSMS1 201 M Outdoor Unit Stand 18"High ❑QSMS1 801 M Outdoor Unit Stand 24"High L],Q'i' MS2401M Heavy Duty Wall Mounting Bracket—Coated Steel QSWB2000M-1 Heavy Duty Wall Mounting Bracket—316 Series Stainless Steel QSWBSS 1 O'x 3/8"x 1 O'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-10 15'x 3/8"x 15'x 5/8"Lineset(Twin-Tube Insulation) _�3 J�T_� o MPLS3858�112T-1 5 .................................................__........................................................................ ......................................................................... .......................-------------............ 30'x 3/8"x 30'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-30 50'x 3/8"x 50'x 5/8"Lineset(Twin-Tube Insulation) ❑MPLS385812T-50 ...................... 65'x 3/8"x 65'x 5/8"Lineset(Twin-Tube Insulation) o MPLS385812T-65 ............................ 1 00'x 3/8"x I 00'x 5/8"Lineset(Twin-Tube Insulation) o MPLS385812T-100 Specifications are subject to change without notice. 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: inch 7/16x1 Oblong hole 7/I6x13/I6 Oblong hole Installation plafe 5-1/16 8-7/8 8 7/8 4-5/16 Indoor unit IJ 43-5/16 z I ar "" b 3/16 42-7/8 -27/3 -27/3 m I-15/16 19-3/4 17-5/16 4-3/8 Air in Nall hale 03 3/16 9 3/8 t1 �7 Installation plale Pi 7in 2-112 �. aD Drain hose — 2 9/I6 3 33 I/8 1 I/8 Air out 4 7l8 6-5/I6 2-5/16 _ 7-1/4 ` — Insulation /2 O.D a Liquid line #318 19-11116 (flared ronncclion IlIB) Gus line /1/2 I6-15/I6 (flared connection 05/8) 3/16 a 2-9/I6 Drain hose Insulation 41-1/8 Connecled part 15/8 0 D 2-9/16 Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: inch REQUIRED SPACE *1 20 in.or more when front and sides of the unit are clear 16-7/16 Drain hole 01-5/8 oie Air in 1-9/16 4 op O2 Air in '6 Air out 00e 01 0/- 2=h.l. 13/32X13/16 —6-7/8 J. 19-11/16 *2 When any 2 sides of left,right and rear of the unit are clear 33-1/16 3-3/16 5/1 1 Service panel 7-' Liquid refrigerant pipe joint Refrigerant pipe(flared)o 1/4(18 kBtu/h) Refrigerant pipe(flared)o 3/8(24 kBtu/h) co N Cq rn L U L M I I Gas refrigerant pipe joint I!OL�t,- Refrigerant pipe(flared)o 1/2(18 kBtu/h) frig e eran R f g t t pipe(flared)o 5/8(24 kBtulh) 7-11/16 AkMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Tall Free:800-433-4822 www.mehvac.com FORM#MSY-GL24NA MUY-GL24NA-201902 Intertek Specifications are subject to change without notice. 2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.