.... 10x3 _-lo, , DN. TO G4.. _.. WATER SERVICE G-3 s m GRILLE REAR VESTIBULE CA � 14x3 100 CfM , ; 550 CFM ROOM 60CFM I G4 Y AC-1 E ECTR CA ROOM I 1 6 i LR 13 EF-2 11 8s E i 16"e DROP - CD-3 G4 : CD-3 ..CD-3 100 CFM _, DROP } DROP 50 CFM 12 60 CFM 6'm 15 40 CFM ;, 1 100 CFM 6W"a �'- - ( 12"el 550 CFM ---- 8 fi m STAGING G5 ... II 1040 CFM 15 i 60 CFM _ s"0. io 6"o .. b, _ io G-4 Wo 100 CFM UP FROM i6 a _i 6, „6 ! I ( EXHAUST GRILLE 6 0 6"m WOMEN'S RESTROOM Os MEN'S RESTROOM 6-0 NASH ROOM WO EXHAUST RETAILWA,K-IN `�. J0"o ( ( 6 14¢ % 10 -11 10 .. �B .. .. 10,o Lai : G1 - 270 OfM ..... -- DUCT UP ..UP TO ,_.-.._.. _. K j EF-1 t ___.-... _... 74"o t I 250 CFM 550 CFM' REFRIGi G-1 G-1 G 1, G 1 G 1- m Y- slo"o __ WALK-IN FREEZER -- 700 CFM 705 CFM' -1 .6. --700 CFM------i 700 CFMj-- 650 CFM II(� '� B o - v Wo I 14"m 6 /-<O 14"o 14"e - 625 CFM .-..__- (3 TYP.) I ` _ ''� \ -_' 14 0 L0.1 14"o 14 "0, _ r -22x20 ' 270 CFM UP TO 6 �> G-1- -.0 14 m ! Ji /iJ20"m i O 300 CFM 10 �) 400 CfM 100�.. L0.i_ 1 24x20 ;_.. _... WALK-IN REFRIG. '. O 10'0 H 290 CFM LD-1 ; _. LD 1 4.. FROM ----}- _.._._._.. lwlo,o 400 CFM 400 CFM ,. RTU-2 40Q CFM 540 CFM 67 LO1290 CFMJJ����///pipGi ILYj�500 CFM0 0 s 6 FOOD;'SERV19E 16'o LD-I AC-2 20x20 ° G- `' _.._ _ - . 3 I 330CFM �.,..._.. - UPTO -.- r -.._. .__. OCFM ;-..._ .6{ .. x 6 , : ___ iq•s .._-.._;. ._.. RTU-1 G_1 _ 200 CFM ��� O.. i 6 12"0 Wo IV, 810 CFM DELIVERYVESTIB�ILE ` sm 0__._-- 9 `2OX2o T�o�Rru-2 k __ - 6 14"m m"0 a o -1 o m^m „ Wo m DN. FROM o o ' - RTU-1.. 'Lp t G-1 '540 CFM --. O 10.0 L0.1 400 CFM - - 10"0 -. - - - 290 CFM m I LD-1 10"e - LD-1 �; n. o LD 1 400 CFM 400 CFM .. o .. _ .330 CFM 6 14"0 G6 •L „..-_ ? .__3 .�.__ mxiz� s iz"m 1O"m SELF SERVICE _ uPTo 9 , .-__ + 3 RTU 3 WALK-IN REFRIG. F AREA LD 1 1 o 330 CFM .._ - - -.. RETAI �2Qx2Q DN. FROM 14 e 6 F ,_..G_i. O --. -RTU-3 __. a ..... o. j 6s5cFM 14^0 COFFEE 1 HVAC FLOOR PLAN M1.0 114" = V-0" KEY- Oi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i6 GRILLE OPEN TO ABOVE CEILING. SHEET GENERAL NOTE: A. MECHANICAL CONTRACTOR SHALL ADJUST ALL LINEAR SLOT DIFFUSERS TO A GENERALLY VERTICAL FLOW. ADJUSTMENT SHALL BE MADE SO AS TO AVOID AIRFLOWS ON SENSORS, REFRIGERATION CASES, OR OPEN FOOD REFRIGERATION EQUIPMENT. HVACLEGEND SYMBOL DESCRIPTION _ 10x8 NEW RECTANGULAR OR ROUND DUCT 12"m FLEXIBLE DUCT 8 SUPPLY AIR DUCTWORK UP THROUGH PLAN Q RETURN AIR DUCTWORK UP THROUGH PLAN EXHAUST AIR DUCTWORK UP THROUGH PLAN J 90` ELBOW WITH TURNING VANES MANUAL AIR VOLUME CONTROL DAMPER ® 4 WAY SUPPLY DIFFUSER 3 WAY SUPPLY DIFFUSER f ®y 2 WAY OPPOSED SUPPLY DIFFUSER ®—� 2 WAY CORNER SUPPLY DIFFUSER RETURN AIR DEVICE ® EXHAUST AIR DEVICE AC-X AIRCURTAIN L0.X LINEAR SLOT DIFFUSER WITH PLENUM 0 COMBINATION TEMPERATURE/HUMIDITY SENSOR OT TEMPERATURE SENSOR © CO2SENSOR A TYPE MARK XXX CFM CFM RTU-10 MECHANICAL EQUIPMENT TAG S—� CONDENSATE PIPING EF-X ROOF MOUNTED EXHAUST FAN EF-X INUNE EXHAUST FAN ! L RTU-X --J PACKAGED ROOFTOP AIR CONDITIONER i M (O Y rn a� M Z Q O m Q Z Lu w < z w Q W o ¢ cm 0 co cle) 4t Lu o / v, r GV O N = sn m o LL Z L0 0 J LL j ILL LLI Q Q U Ltl CDw d w'o fif O l n Z N n' Om W o 6 aa W M1.0 WIND SPEED ZONE BUILDING LOCATION _ (FBC FIGURE 1609A) FT.PIERCE FL __ 160 MPH\FBC ROOFTOP UNIT (RTU) ) REFER TO STRUCTUPJ SHEETS FOR CURB ATTACHMENT TO FIRM 1 RTU TIE -DOWN DETAIL _ M3.0 NOT TO SCALE I I � I ALTERNATE LOCATION I / - I .TOP OF J015T CHORD I I I OPEN WEB JOIST ATTACHMENT - TOSTRUCTURE - SAFETY HANGER 1712 GA WIRE OR 1718 GA METAL STRAP UP TO 24' CEILING CEILING DIFFUSER C3 CEILING MOUNTED AIR DIFFUSER SUPPORT DETAIL 3A NOT TO SCALE 4'-0" MAXIMUM MAXIMUM SAG 1/2" PER FOOT OF SUPPORT SPACING. FLEXIBLE DUCT NOTES: 1. DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. 2, SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR CAUSE OUT OF ROUND SHAPE. FLEX DUCT SUPPORT DETAIL M3� NOT TO SCALE PIPE SUPPORT SHALL BE F "PIPE PROP" MODEL #APS-1 AS MANUFACTURED BY JMB INDUSTRIES, INC. SUPPORTS PIPE UP TO 1.5" DIAMETER SCHEDULE 40 PVC CONDENSATE PIPING - 3/4" SCH. 40 PVC PIPE CUT TO LENGTH AND GLUED TO BASE AND / SADDLE PER NOA - INSTRUCTIONS. --------- ADHESIVE THROUGH OOZE _ HOLES PER NOA INSTRUCTIONS. / \ 1 PRE-ENGINEERED CURB WITH P.T. WOOD NAILER BY RTU SUPPLIER % AW REFER TO RTU TIE -DOWN SUPPLIER I I INSTALLATION REQUIREMENTS _-� RTU BASE RAIL, SUPPLIED WITH RTU -----I- 1/4"-14X 1-t/4" LONG ZINC PLATED TEK SCREWS, 4 EA. THROUGH CLIP/ WOOD I I NAILER AND 4 EA. THROUGH CLIP/BASE RAIL. I g PRE-ENGINEERED RTU TIE DOWN CLIPS I I MANUFACTURED BY CURBS PLUS, INC. �y I I ROOFING MATERIALS, REF. ARCH i i STRUCTURAL SUPPORT FRAMING FOR RTU CURB. REFER TO �SHEETS FOR ATTACHMENT DETAILS. TYPICAL R FLEXIBLE RETURN D TAKEOFF1 BALANCIN DAMPER SEE PLAN FOR EXACT SIZES, DIRECTION, TYPE, ETC. OF RTU DROPS, FLEX DUCTS, AND RIGID DUCTS. TYPICAL DUCT PLENUM DETAIL M3.0 NOT TO SCALE 7W. JOIST TYPICAL RIGID SUPPLY DUCT WITH 45` TAKEOFF RIGID DUCT PLENUM FULL SIZE OF UNIT CONNECTION DOWN FROM RTU WITH END CAP (TYPICAL) CEILING BIRD SCREEN --- EXHAUST FAN GASKET METAL STRAP FASTENERS FAN CURB BASE 1-1Y[° (SEE NOTE) PRESSURE TREATED MINIMUM PREFABRICATED, _ WOOD NAILER INSULATED CURB. GRAVITY DAMPER \ DAMPERTRAY :18'MIN' BASE FLASHING ROOF INSULATION - ROOF MEMBRANE // `REFERENCE STRUCTURAL METAL ROOF DECK J DRAWINGS FOR CURB ATTACHMENT TO STRUCTURE. DUCT SUPPORT ALL FASTENERS NOTE: INSULATION (WHERE REQ'D) AROUND FASTENED TO PROVIDE MIN. (3) 5/16'x2" CADMIUM PLATED DECK &DUCT FASTENERS PER SIDE. ONE MAX 4" FROM EACH CORNER AND ONE IN CENTER MAX. WIND SPEED =160 MPH. ROOF FAN MOUNTING_ DETAIL M3.0 NOT TO SCALE ACTORY PROVIDED PIPE STRAP NOTE: DETAIL FOR CLARIFICATION PURPOSES ONLY. INSTALL PIPE SUPPORTS PER NOA 07-0504.08 SPECIFIC INSTALLATION INSTRUCTIONS. -- FACTORY PROVIDED 1-1/2' PIPE PROP SADDLE l FACTORY PROVIDED PIPE % PROP BASE. SUPPORT@ MAX. 4'-D' O. C. / ADHERE PIPE SUPPORT TO WALK PAD SECTION USING ADCO MILLENNIUM LPS ELASTOMERIC ROOFING SEALANT PER NOA INSTRUCTIONS. 12"X12' WALK PAD SECTION FULLY HEAT WELDED TO - / ROOF ROOF MEMBRANE SYSTEM / Eg C_ONDENSATE PIPE ROOF SUPPORT DETAIL 3.0 NOT TO SCALE MASTER BILT LAG BOLTS (TYPICAL). REFRIGERATION UNIT REFERENCE STRUCTURAL PROVIDED BY OTHERS DRAWINGS FOR TYPE, SIZE, SPACING ETC. CURBAND \\ -- REFRIGERATION REFER TO STRUCTURAL UNIT SEALED PER DRAWINGS FOR CURB ARCHITECTURAL CONSTRUCTION AND DETAILS. -- CURB TIE -DOWN TO STRUCTURE. _„__ FULLY COORDINATE =r; _- INSTALLATION WITH REFRIGERATION UNIT ' MANUFACTURER. THIS DETAIL SHOWN FOR COORDINATION PURPOSES ONLY. FOR SPECIFIC WIND LOADING REQUIREMENTS NOT TO EXCEED 160 MPH, SEE STRUCTURAL DRAWINGS, j 11 MASTER BILT MOUNT DETAIL M3.0 NOT TO S CALEALE BLOCKING BY OTHERS AIR CURTAIN - SEE SCHEDULE FACTORY ACCESSORY MODEL MB123 QUICK MOUNTING PLATE FASTENERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS N_ -'� ERINGFACTO VANEANGLESET AT ADJUST ATfACTORY-DO NOT ADJUST / I ALIGN BOTTOM OF AIR CURTAIN I [ WITH TOP OF DOOR FRAME �' I DOORJAMB EXTERIOR DOOR [ MAGNETIC REED DOOR SWITCH IlkW WAIR FLOW -�- OUTSIDE^ INSIDE - AIR CURTAIN INSTALLATION DETAIL M3.0 NOT TO SCALE 12 INLINE FAN MOUNTING DETAIL M3.0 NOT TO SCALE STRUCTURE-TYP UNI-STRUT-TYP ALL THREAD ROD WITH LOCK NUTS AND WASHERS PER MANUFACTURER'S INSTRUCTIONS - TYP EXHAUST FAN SUPPLY SPIN -IN FITTING WITH DUCT DAMPER. AFTER INSULATED ROUND BALANCING OF SYSTEM FLEXIBLE SCREW DAMPER IN PLACE WITH SHEET METAL SCREW. DUCT(MAX. 8'-0" LONG) SIZE TO MATCH DIFFUSER NECK. ROUND METAL DUCT(EXTERNAL INSULATION INSULATION) :: _.. CEILING CEILING DIFFUSER CEILING DIFFUSER RUNOUT DETAIL M3.0 NOT TO SCALE PROVIDE PLUG PROVIDE CLEANOUT AT EACH FOR MAINTENANCE CHANGE OF DIRECTION OR EVERY 30' DRAIN LINE. SLOPE WITH A FLOW 1/8'/FT MINIMUM TO REAR SCUPPER. CONNECT A WITH T AIR GAP DRAIN PLUG -------r A=FAN SUCTION PRESSURE, 1 INCH MAX, TONS CONDENSATE PIPE SIZE 30 1-1/4' 5 CONDENSATE DRAIN TRAP DETAIL M3.0 NOT TO SCALE WALLSCUPPER CONDENSATE LINE ROUTED TO DOWNSPOUT - °. CONDENSATE I LINE ROUTED TO ROOF DRAIN ROOF DRAIN COLLECTOR - DOWNSPOUT ROUTE CONDENSATE DRAIN PIPING TO ROOF DRAIN OR DOWNSPOUT AS INDICATED ON ROOF PLAN. CONDENSATION TERMINATION DETAIL NOT TO SCALE HVAC GENERAL NOTES 1. ALL MECHANICAL WORK SHALL BE IN STRICT ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE- MECHANICAL, SMACNA, ILL, LOCAL CODES, MANUFACTURER'S RECOMMENDATIONS, AND ALL AUTHORITIES HAVING JURISDICTION. ES BEFORE FABRICATION OF DUCTWORK AND PROVIDE ADDITIONAL OFFSET AND/OR CHANGES IN DUCT SIZES TO MEET FIELD CONDITIONS 00 2. CONTRACTOR TO VISIT SITE AND VERIFY ALL CLEARANCES IAND COORDINATE WITH ELECTRICAL, PLUMBING AND FIRE PROTECTION SUBCONTRACTOR BEFORE ANY CONSTRUCTION WORK, 3. SUPPLY AIR, RETURN AIR OUTSIDE AIR AND EXHAUST AIR DUCTWORK SHALL BE SHEET METAL CONSTRUCTION. DUCT SHALL BE INSTALLED SECURELY SUPPORTED, HUNG OR SUSPENDED FROM THE STRUCTURE. JOINTg SHALL BE SEALED WITH 3" WIDE GLASS FABRIC TAPE AND FOSTER 30/30 MASTIC OR EQUAL. DUCT CONSTRUCTION, SEALING AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH 2O17 FLORIDA BUILDING CODE - MECHANICAL AND THE JURISDICTION'S LATEST CODE ACCEPTED SMACNA STANDARDS. 4. OUTSIDE AIR INTAKE$ (ROOFTOP UNITS, GRAVITY ROOF VENTS, LOUVERS) SHALL MAINTAIN A MINIMUM OF 10'-0" FROM ANY EXHAUST OR SANITARY VENT. 5. PROVIDE ALL MECHANICAL EQUIPMENT WITH MANUFACTURER'S RECOMMENDED SERVICE AREA CLEARANCES. 6 ALL ROOFTOP UNITS SHALL BE AND INSTALLED TO WITHSTAND LOCAL WIND LOAD DESIGN. 7. SMOKE DETECTORS SHALL BE FURNISHED AND INSTALLED IN RTU BY THE UNIT MANUFACTURER, WIRED TO THE KEY SWITCH BY THE MECHANICAL CONTRACTOR AND WIRED TO THE FIRE ALARM BY THE FIRE ALARM CONTRACTOR. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 12 NATIONAL FIRE ALARM CODE' NFPA 90A STANDARD FOR INSTALLATION OF AIR-CONDITIONING AND SYSTEMS, 0FLORIDA C VENTILATINGY TEMS THE2 17 FL RADA BUILDING ODE•MECHANICAL, AND THE MANUF ACTURERS INSTALLATION INSTRUCTIONS. PROVIDER VISIBLElAUDIBLE NOTIFICATION PANEL. MAKE: SYSTEM SENSOR SSK451 OR EQUAL, COMPATIBLE WITH BUILDING FIRE ALARM SYSTEM. 8. PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. 9 HVAC CONTRACTORS RESPONSIBLE FOR ELECTRICAL COSTS WHICH MAY RESULT 0 SUBSTITUTED I NSI LE R ANY ADDED I I FROM S BSTIT TED EQUIPMENT. 10. PROVIDE EXTERNAL DUCT INSULATION FOR SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK. DUCTWORK INSULATION 1 I N 0 PL I ION SHALL BE FOIL FACED FIBERGLASS DUCT WRAP A MINIMUM THERMAL RESISTANCE fi 0 • N R OF ..() INSULATION SHALL HAVE VAPOR BARRIER. INSTALL PER MFR. REQUIREMENTS. 11. COORDINATE CEILING MOUNTED DIFFUSERS, REGISTERS, AND GRILLES AND OTHER CEILING MOUNTED EQUIPMENT WITH LIGHTING FIXTURES. 12. TURNING VANES SHALL BE PROVIDED IN ALL SUPPLY DUCT RECTANGULAR ELBOWS WITH ANGLES BETWEEN 15 DEGREES AND LESS THAN 90 DEGREES PER THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS MANUAL, 13. DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED. 14, DUCTWORK, DIFFUSERS, REGISTERS, GRILLES, AND OTHER ITEMS OF THE AIR HANDLING SYSTEM SHALL NOT BE SUPPORTED BY THE CEILING OR CEILING SUSPENSION SYSTEM. 15. UNLESS OTHERWISE NOTED, INSTALL DUCTWORK AS HIGH AS POSSIBLE, TIGHT TO BOTTOM OF STRUCTURE. COORDINATE DUCT ELEVATION WITH STORM LEADERS, WATER PIPING, SANITARY DRAINS AND MAJOR ELECTRICAL CONDUITS. 16. CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT & MATERIALS. INSTALLATION OF EQUIPMENT SHALL COMPLY WITH MANUFACTURER'S SPECIFICATIONS AND CLEARANCE REQUIREMENTS FOR SERVICING OF EQUIPMENT. 17. VERIFY VOLTAGE WITH ELECTRICAL CONTRACTOR BEFORE ORDERING EQUIPMENT. i 18, PROVIDE A TRAP IN ALL CONDENSATE PIPING SERVING AIR HANDLING UNITS AND ROOFTOP UNITS. SLOPE CONDENSATE LINE 1/8" PER FOOT. CONDENSATE LINES SHALL BE PVC SCH. 40. ALL CONDENSATE DRAIN PIPING SHALL BE PROPERLY SUPPORTED. SEE "CONDENSATE DRAIN TRAP' DETAIL 19. GUARANTEE, FOR ONE YEAR AFTER DATE OF ACCEPTANCE BY THE OWNER, ALL EQUIPMENT, MATERIALS AND WORKMANSHIP TO BE FREE FROM DEFECT. 20. DO NOT CUT STRUCTURAL MEMBERS WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER 21. FLEXIBLE AND RIGID ROUND DUCT TAKE -OFFS FOR DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSE R NECK. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 8'-0'. FLEXIBLE DUCT SHALL BE THERMAFLEX TYPE M-KC OR EQUAL, FLEXIBLE DUCT SHALL BE INSULATED FIBERGLASS, R3, CLASS 1, UL181 LISTED AND COMPLY WITH NFPA 90A AND NFPA 90B. 22. ALL WALL MOUNTED TEMPERATURE, HUMIDITY, AND CO2 SENSORS SHALL BE INSTALLED AT AN ELEVATION OF 54" ABOVE FINISHED FLOOR TO THE TOP UNLESS OTHERWISE NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED SENSORS SHALL BE COORDINATED WITH OTHER TRADES FOR A NEAT APPEARANCE. FINAL LOCATION OF SENSORS SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER OR THEIR REPRESENTATIVE IN THE FIELD. 23. PROVIDE FLEXIBLE NEOPRENE DUCT CONNECTORS ON THE DISCHARGE AND ENTERING SIDES OF PACKAGED ROOFTOP UNITS, FANS, AND OTHER VIBRATING EQUIPMENT TO WHICH DUCTWORK IS ATTACHED. 24. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TRADES' INSTALLATION SCHEDULES. COORDINATE WORK SCHEDULE WITH GENERAL CONTRACTOR 25. REFER TO ARCHITECTURAL. DRAWINGS FOR ALL RELATED CONSTRUCTION DETAILS AS APPLICABLE TO THE HVAC SYSTEM. CHASE AND WALL PENETRATIONS INTENDED FOR DUCTWORK AND PIPING SHALL BE VERIFIED WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. 26. MECHANICAL EQUIPMENT, DUCTWORK AND PIPING IS SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK AND PIPING LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK AND PIPING WITHIN THE AVAILABLE SPACE. FIELD VERIFY FINAL LOCATIONS TO INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 27. WHEN THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS NOT CLEAR, OR IS. CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS. THE ARCHITECT/ENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING.- 28. PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL, AND ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE HIMSELF/ HERSELF WITH THE PLANS. 29. CONTRACTOR TO ALLOW SUFFICIENT TIME (APPROXIMATELY 2 WEEKS) FOR EQUIPMENT REVIEW. CONTRACTOR SHALL SUBMIT THE FOLLOWING EQUIPMENT FOR REVIEW (1 HARD COPY) PRIOR TO ORDERING AND INSTALLATION: ROOFTOP UNITS, AIR HANDLING UNITS AND AIR COOLED CONDENSERS, DIFFUSERS AND REGISTERS, EXHAUST FANS AND MAKEUP AIR FANS, DUCT INSULATION, DUCT CONSTRUCTION STANDARDS, 30. AFTER THE HEATING AND AIR CONDITIONING SYSTEM INSTALLATIONS ARE COMPLETE, THE CONTRACTOR SHALL HAVE EACH SYSTEM TESTED, ADJUSTED, AND BALANCED BY AN INDEPENDENT TESTING AND BALANCING CONTRACTOR. SEE SPECIFICATIONS FOR TESTING AND BALANCING CONTRACTOR CERTIFICATIONS AND REQUIREMENTS. UPON COMPLETION OF TEST AND BALANCE OF ALL SYSTEMS, THE CONTRACTOR SHALL PRESENT THE OWNER AND ARCHITECT WITH A WRITTEN TEST AND BALANCE REPORT IN A TIMELY MANNER PER SPECIFICATIONS. HVAC ROOFTOP UNIT SCHEDULE SUPPLYAIRFAN DATA ELECTRIC HEAT UNIT POWER WEIGHT COOLING CAPACITY BASISOFDESIGN KW @ (LBS. TOTAL SENSIBLE AREA NOMINAL SUPPLY OUTSIDE ES,P. VOLTAGE CONTROL RTU COOUNG COOLING EDB EWB AMBIENT EER MANUFACTURER MARK SERVED TONS AIR(CFM) AIR (IN.) HP LISTED STAGES VOLTAGE PHASE MGA MOCP ONLY) MBH MBH (7) (`F) (DB°F/WB`F) [JEER] PRODUCT LINE MODEL NOTES RTU-1 RETAIL 8.5 3400 595 0.5 2.0 22.5 1 208V 3 69 70 1266 102.9 75.4 77.2 64.8 96/79 12.4 LENNOX LCH102H4B 1-20 __ [129] ENERGENCE RTU-2 FOOD 10 400D fi65 0.5 3.0 WA WA 208V 3 52 60 1220 113,3 96.2 76,0 62.9 95I79 12.2 LENNOX LCH120H4B 2-20 _SERVICE [13.21 ENERGENCE RTU3 RETAIL 7.5 3600 000 0.5 20 15 1 208V 3 49 50 1228 87.7 67.2 75.8 fi3.3 9Y/9 127 LENNOX LCHD9YH4B 2.2D NOTES: 1. PROVIDE CO2 SENSOR FOR INTERLINK WITH BUILDING AUTOMATION SYSTEM. 2. PROVIDE LENNOX HUMIDITROL HOT GAS REHEAT OPTION, 3. PROVIDE REMOTE WALL MOUNTED COMBINATION TEMPERATUREIHUMIDITY SENSOR MODEL 21W06 4. REFER TO CONTROL SYSTEM NOTES FOR CONTROL COMPONENTS REQUIREMENTS. 5. PROVIDE 5-MINUTE ANTI -SHORT CYCLE TIMER. 6. PROVIDE THRU THE BASE ELECTRICAL AND SINGLE POINT CONNECTION. 7. PROVIDE WITH FACTORY 2" THROW AWAY PLEATED MERV 8 FILTERS. 8. PROVIDE WITH 18" ROOF CURB. 9. PROVIDE FACTORY 15 AMP GFCI SERVICE OUTLET WITH WEATHERPROOF COVER. COORDINATE WITH ELECTRICAL CONTRACTOR TO PROVIDE FIELD WIRING TO RECEPTACLE. 10. PROVIDE WITH FACTORY INSTALLED DISCONNECT. 11. PROVIDE WITH MOTORIZED DAMPERAND OUTSIDE AIR INTAKE HOOD. 12. PROVIDE MANUFACTURER'S MOTOR AND DRIVE PACKAGE AS REQUIRED TO MEET SCHEDULED AIR CAPACITIES AND PRESSURE DROP. 13. PROVIDE FACTORYAPPLIED PHENOLIC COATING FOR CORROSION PROTECTION ON CONDENSER COILS WITHIN 10 MILES OF SALT WATER. 14. PROVIDE BUILDING AUTOMATION SYSTEM (BAS) EQUIPMENT - REFER TO SAS SYSTEM MASTER SPEC FOR SYSTEM DETAILS AND EQUIPMENT PART NUMBERS. 15. PROVIDE FACTORY INSTALLED BACNET BAS INTERFACE. 16. PROVIDE LENNOX DIRTY FILTER SWITCH. 17. PROVIDE LENNOX IMC CONTROL BOARD (STANDARD ON L-SERIES UNITS) 18. TEMPERATURE SETPOINT: 74"F COOLING, 68'F HEATING HUMIDITY SETPOINT: 50% RELATIVE HUMIDITY. 19. PROVIDE WITH FACTORY CONDENSATE PAN WATER LEVEL MONITORING DEVICE FOR COMPLIANCE WITH FBC 2020 MECHANICAL, SECTION 307.2.3. 20. PROVIDE WITH FACTORY INSTALLED SUPPLY AND RETURN SMOKE DETECTORS. OUTSIDE AIR CALCULATION AREA SERVED AREA (SOFT) CFM /SQFT UNOCCUPIED MIN. O/A REQUIRED # PEOPLE CFM/ PERSON PEOPLE O.A. REQ'D(CFM) COMBINED O.A. REQ'D(CFM) TOTAL O.A. REQ'D (CFM) TOTALOA. SUPPLIED (CFM) OFFICES 169 0.06 11 2 5 10 21 21 RETAIL 2109 0.12 253 42 7.5 315 568 568 CORRIDORS 45 0.06 3 0 0 0 3 3 RTU-1 592 595 FOOD SVC 1 805 1 0.18 1 145 5 1 7.5 1 38 1 183 1 1185 RTU-2 185 665 RETAIL 822 1 0.12 99 13 7.5 98 197 WASH RM. 297 0.18 54 2 7.5 15 09 IjU RTU-1 ON TES: 1. OCCUPANCY LOAD VENTILATION RATES ARE BASED ON NET OCCUPIABLE SPACE IN ACCORDANCE WITH THE 2020 FLORIDA MECHANICAL CODE, TABLE 403.3.1.1. 2. ANTICIPATED NUMBER OF PEOPLE IS BASED ON AN OCCUPANCY LOAD FACTOR (# PEOPLE/SF) VALUE (BASED ON THE 2020 FLORIDA MECHANICAL CODE, TABLE 403.3,1.1). RTU-1, 2, & 3 TEST AND BALANCE NOTES 1. TEST AND BALANCE CONTRACTOR TO OBTAIN INITIAL BALANCE OF COOLING CFM FOR RTU USING FAN SHEAVE ADJUSTMENT TO WITHIN -A 5% SCHEDULED SUPPLY AIR CFM. PRODIGY CONTROLLERUSED MAYBE FOR R FINAL 5%TO OBTAIN SCHEDULED H D SUPPLY AIR CFM. 2. SET MINIMUM OUTSIDE AIR DAMPER POSITION FOR COOLING AND VERIFY OUTSIDE AIR CFM PER RTU SCHEDULE. 3. USING PRODIGY CONTROLLER, VERIFY HEATING CFM EQUALS COOLING CFM. 4. ALL PRODIGY CONTROLLER SETTINGS OTHER THAN THOSE MENTIONED ABOVE SHALL REMAIN AS THEIR DEFAULT VALUE AS SET FROM THE FACTORY. 5. VERIFY POSITIVE BUILDING PRESSURE. AIR BALANCE SCHEDULE SYSTEM CFM RTU-1 +595 RTU-2 +fi65 RTU-3 +400 EF-1 .200 EF-2 -60 EF3 -900 BUILDING POSITIVE PRESSURE +500 RTU-1, 2, & 3 SEQUENCE OF OPERATION SUPPLY AIR BLOWER SPEED UNIT HAS FOLLOWING SUPPLY AIR BLOWER SPEED SETTINGS THAT PERTAIN TO THIS INSTALLATION: • COOLING SPEED • HEATING SPEED COOLING MODE • Y1 DEMAND: COMPRESSOR 1 OPERATES AND SUPPLY AIR BLOWER OPERATES AT COOLING SPEED. • Y2 DEMAND: ALL COMPRESSORS OPERATE AND SUPPLY AIR BLOWER OPERATES AT COOLING SPEED. DEHUMIDIFICATION MODE • IF THE UNIT RECEIVES A CALL FOR DEHUMIDIFICATION, ECONOMIZER FREE COOLING IS LOCKED OUT (ON UNITS EQUIPPED WITH ECONOMIZER). • CALL FOR DEHUMIDIFICATION, NO YI, Y2 DEMAND: 15T STAGE COMPRESSOR OPERATES, SUPPLYAIR BLOWER OPERATES AT COOLING SPEED, AND THE REHEAT VALVE IS ENERGIZED. • Y1 DEMAND WITH A CALL FOR DEHUMIDIFICATION: ALL COMPRESSORS OPERATE, SUPPLY AIR BLOWER OPERATES AT COOLING SPEED AND THE REHEAT VALVE IS ENERGIZED. • Y2 DEMAND WITH A CALL FOR DEHUMIDIFICATION: ALL COMPRESSORS OPERATE, SUPPLYAIR BLOWER OPERATES AT COOLING SPEED, AND THE REHEAT VALVE IS DE - ENERGIZED. HEATING MODE (ELECTRIC HEAT) • W1 DEMAND: 1ST STAGE ELECTRIC HEAT IS ENERGIZED AND THE SUPPLY AIR BLOWER OPERATES AT HEATING SPEED. • W2 DEMAND: 2ND STAGE ELECTRIC HEAT IS ENERGIZED AND THE SUPPLY AIR BLOWER OPERATES AT HEATING SPEED. MODULATING OUTDOORAIR DAMPER • THE MINIMUM DAMPER POSITION FOR "OCCUPIED HIGH BLOWER' IS ADJUSTED DURING UNIT SETUP TO PROVIDE MINIMUM FRESH AIR REQUIREMENTS PER RTU SCHEDULE, • WHEN SUPPLY AIR BLOWER IS OFF, THE OUTDOOR AIR DAMPER IS CLOSED. • WHEN UNIT IS IN OCCUPIED MODE AND SUPPLY AIR BLOWER IS OPERATING, THE OUTDOORMR DAMPER IS AT MINIMUM "HIGH BLOWER° POSITION. I HVAC EXHAUST FAN SCHEDULE EXT. STATIC UNIT POWER BASIS OF DESIGN MARK CFM PRESSURE FAN TYPE DRIVETYPE SONES HP FAN RPM NOTES VOLTAGE PHASE MANUFACTURER MODEL EF-1 200 CFM 0.25 in-wg DOWNBLAST DIRECT 5.0 125 1100 120V 1 LOREN COOK ACED 90C10D 1,2 EF-2 60 CFM 025in-wg INUNE DIRECT 0.6 _ 28 WATTS 685 120V 1 LOREN COOK GN-148 2,3 EF3 900 CFM 0.25 irnwg DOWNBLAST DIRECT 6.0 116 1075 120V 1 LOREN COOK ACED 12OC10D 1,9 NOTES: -NO SUBSTITUTIONS PERMITTED- 1. PROVIDE WITH FACTORY DISCONNECT, FACTORY WIRED SOLID STATE SPEED CONTROLLER, 18" HIGH ROOF CURB WITH DAMPER TRAY, BACKDRAFT DAMPER, AND BIRD SCREEN. 2. WIRE FOR CONTINUOUS OPERATION. 3. PROVIDE WITH FACTORY DISCONNECT & FACTORY WIRED SOLID STATE SPEED CONTROLLER. FAN SHALL BE WIRED TO EMERGENCY SHUTOFF SWITCH PROVIDED BY OTHERS. REFERENCE ARCHITECTURAL AND ELECTRICAL DRAWINGS. HVAC AIR DEVICE SCHEDULE TYPE MARK MANUFACTURER MODEL SERVICE DESCRIPTION MOUNTING TYPE MATERIAL NECK SIZE FACE SIZE NOTES CD-1 PRICE AMD SUPPLY LOUVERED FACE DIRECTIONAL DIFFUSER LAY4N ALUMINUM 18'X18' 24X24' 1,7 CD -2 PRICE_ AMD SUPPLY LOUVERED FACE DIRECTIONAL DIFFUSER LAY4N ALUMINUM ALUMINUM 18'Xl 6X6 24'X24' NECK+6" 6,7 5,7 CD3 _ PRICE _AMD SUPPLY LOUVERED FACE DIRECTIONAL DIFFUSER SURFACE G1 PRICE 63OFF RET/TRANS/EXH LOWERED FACE FILTER RETURN GRILLE LAY4N SURFACE ALUMINUM 205Q0' NECK+33/4• 4 G2 _ PRICE 63OFF RETURWTRANSFER LOUVERED FACE FILTER RETURN GRILLE ALUMINUM 16"x16" NECK-3-3/4' 4 G3 PRICE 630D EXHAUST LOUVERED FACE RETURN GRILLE SURFACE ALUMINUM ALUMINUM ALUMINUM lWxl0" 81x8' 6'x6" NECK+IJ/4" NECK+344" NECK+1.3/4' 4 - G-4 PRICE 630FF RETURN/EXHAUST LOUVERED FACE FILTER RETURN GRILLE SURFACE Gb PRICE 630 D TRANSFER LOUVERED FACE RETURN GRILLE SURFACE LAY -IN G-6 PRICE 82F TRANSFER EGG CRATE FACE RETURN GRILLE ALUMINUM IALUMINUM 225Q2• SEE PLAN NECK-11/16' WA 2,3 LD-1 PRICE TBDI4 SUPPLY 48" INSULATED PLENUM W/ (4) 1' SLOTS LAY4N NOTES : -NO SUBSTITUTIONS PERMITTED- 1. FOR LAY411 CEILINGS PROVIDE WITH 18"X18" FULL FACE APPEARANCE DIFFUSER NECK. PROVIDE WITH FACTORY SQUARE TO ROUND NECK ADAPTER MODEL "SR'. ROUND NECK SIZE SHALL BE EQUAL TO FLEX SIZE SERVING DIFFUSER. 2. PROVIDE WITH PLENUMINTERNALLY LINED NTH COATED FIBERBOARD.EXTERNALLY INSULATE PLENUM UPON INSTALLATION WITH DUCT WRAP INSULATION. 3. PROVIDE WITH CENTER NOTCH OPTION (CN) AS REQUIRED WHEN USED IN 24' T-BAR CEILING. 4. "QR' STYLE (114 TURN FASTENERS ONLY) -OMIT HINGE. FILTER TYPE RETURN GRILLES PROVIDED SOLELY FOR MAINTENANCE PURPOSES. OMIT FILTER UPON INSTALLATION. 5. PROVIDE WITH TYPE 6 BEVELED SURFACE MOUNT FRAME AND FACTORY SQUARE TO ROUND NECK ADAPTER MODEL "SR". 6. PROVIDE LAY -IN STYLE FACE DIFFUSER AND ALUMINUM PLASTER FRAME MODEL APF. COORDINATE LOCATION WITH CEILING FRAMING INSTALLER. 7. PROVIDE WITH FACTORY BACK PAN INSULATION. HVAC AIR CURTAIN SCHEDULE BASIS OF DESIGN UNIT POWER MOUNTING MANUFACTURER MODEL VOLTAGE 120V PHASE 1 MARK_ AREA SERVED NOZZLECFM HP 0.5 HEIGHT T-2" NOTES 1-0 AC-1 STAGING POWEREDMRE BCE-lA8 2155CFM AG2 LIVE DERY VESTIBULE POWEREDMIRE BCE-1-0e 2155 CFM 0.5 120V 1 T-2" 1-4 NOTES; -NO SUBSTITUTIONS PERMITTED- 1. MOUNT INSIDE BUILDING ABOVE DOOR AT T-2" A.F.F. MOUNTING HEIGHT IS FROM BOTTOM OF AIR CURTAIN. 2. PROVIDE ALL NECESSARY MOUNTING BRACKETS AND ACCESSORIES. 3. PROVIDE WITH MODEL SM-WO COMMERCIAL MAGNETIC REED DOOR SWITCH. 4, AIR CURTAIN CONTROLLED BY MAGNETIC REED DOOR SWITCH, FAN ON WHEN DOOR IS OPEN. LENNOX SETUP PARAMETERS - FLORIDA STORES (R2) UNIT 1DUNIT 1D CONFIGURATIONS (MECHANICAL CONTRACTOR TO DEFINE I AS APPLICARI P\CONT�CTOR TO DEFINE I AS APPLICABI�i • BACNET CONFIGURATION: GO TO SETTINGS>GENERAL>CONFIGURATION ID1 POSITION 5 SET TO'B" • NETWORK CONFIGURATION: GO TO SETUP>NETWORK INTEGRATION, SET TO BACNET • CONTROL MODE, SET CONTROL MODE TO ROOM SENSOR: CO2, TEMP & HUMIDITY (PER UNIT, AS NEEDED) INDIVIDUAL PARAMTER CONFIGURATIONS (MECHANICAL CONTRA IO-RIODEEINEIASAPPLICABLEI, • PARAMETER 105 DEHUMID MODE:7 NO CONDITIONS • PARAMETER 106 DEHUMID SETPOINT: 50, THIS IS CENTERED SET POINT • PARAMETER 107 DEHUMIID DEADBAND: 3 (DEFAULT) THIS IS THE ACTUAL+/ -VALUE • PARAMETER 117 CO2 DAMPER MAX OPEN %: 50 • PARAMETER 118 CO2 START OPEN PPM: 1200 • PARAMETER 119 CO2 FULL OPEN PPM: 1500 PARAMETER 137 OCCHEAT SET POINT: 68 (BACK UP) PARAMETER 139 OCC COOLING SET POINT: 72 (BACK UP) • PARAMETER 154 OCC BLOWER MODE: ON- CONTINUOUS 1 CFM VALUES / MSAV FAN SPEEDS (AIR BALANCER TO DEFINE I IF APPLICABLEI • HEAT CFM VALUE: PER THE HVAC SCHEDULE • HIGH COOL CFM VALUE: PER THE HVAC SCHEDULE • LOW COOL CFM VALUE: MATCH THE HIGH COOL CFM VALUE • VENTILATION CFM VALUE: MATCH THE HIGH COOL CFM VALUE I' l II( 'IY t �` II1Ji I i/1 l ill , V,LS; u} M LU O Y rn aQ W Z O > J } J z m Z u Q H LU LU T 4 a co 00 CM u') Lu 13J O r C N `- o N SC C/) m GD L Z Y LC'i 00 J j LL LLi a LU 0, z z a < 0 O t~i a J LLj 0 z U) Lu F- O Z in LLJ Lij 10 0 0 •`�� p1AZ VF�'% <Ft �\GENSR P NO/04/4 ✓U7�%USBF,,.. %I 3/10/2022 � N 0 N r_inm pp 0 N 0 N N 0 N 0 N N 0 N 0 N m O 0 N 0 N N 0 N 0 N am O _ N 0 N O 0 m o' ti O C 0 O Z j 0 m O w 0 r F F •> yVj W m o N W 0 U 0 O 0 rc 0 crag m `•• o � N w w w w o w mama Clw 0 2 Q d Z Z SSW u a c o 111_[�YIlJ