HomeMy WebLinkAboutTruss Placement PlanVERIFY ALL DIM's., WALL & COL. HGT's. , GIRDER ,CLG. COFFER CLG. & COL. LOCATIONS, END DETAIL, PITCH, FASCIA, O.H & CANT. DIM. 's SOME DOWN FRAMING REQ. BY BLDR. @ DROP CLG. , CLG. CHANGE & COFFER CLG. AREAS
---------------------
BEAM SCHEDULE
20'0"
-------------
CJ
CJ +
c J a
4
CJ `L
U U U U 1�
TYPICAL CORNER SET
APPROVED TRUSS ANCHOR BY BUILDER
2x4 MINIMUM TOP AND BOTTOM CHORDS
PLUMB CUT CANTLIVER
12
5
2 1
1.5 Q o
UNLESS NOTED 12
OTHERWISE BRG.
A - TRUSS END DETAIL
APPROVED TRUSS ANCHOR BY BUILDER
2x4 MINIMUM TOP AND BOTTOM CHORDS
PLUMB CUT CANTLIVER
12
1-1/2'L 6
HEEL --�-'
11"
BRG
B - TRUSS END DETAIL
N_
�1
O
4-U4"
12
6
N I I
r 21'8-1 /2"
0
A4
RECEIVED
MAR 1 7 2021
Pe,'rm(4iin j f?p.p�jgMgnt
St. L wde C-PurRy
\INDICATES LEFT END OF TRUSS
WHEN RENEWING ENGINEERING SHEETS
THIS WILL BE THE LEFT SIDE OF THE PAGE
DESIGN CRITERIA
FBC 7th Ed. 2020 Res. ASCE 7-10
10 FCF
TRUSS TO TRUSS CONNECTIONS THAT EXCEED THE CAPACITY OF A
STANDARD HANGER ARE THE RESPONSIBBITYOFTHE BUILDER
HANDLING AND ERECTION
CARELESS HANDLING OFTRUSS(ES) SHALL NOT BE PERMITTED. TEMPORARY
AND PERMANENT BRACING FOR HOLDING IRUSSA PLUMB AND FOR
RBISTING LATERAL FORCES SHALL BE DFSIGNEDANDINSTALLEDBY
OTHERS. NO LOADS (FIBER THAN THE ERECTORS, ARE TO BE APPLIED TO
TRUSS(ES) UNTIL AFTERALL BRACING AND FASTENINGS ARE COMPLETEDAT
NO TIME SHALL CONCENTRATED LOADS GREATER THAN DESIGN LOADSBE
APPLIEDTOTRUSS(ES).
BEEN GIVEN A COPY OFTHIS TRUSS REPLACEMENT PLAN WITH TRUSS
ENGINEERING, FOR REVIEW AND COMMENT.PURTHER, THAT THESE
DOCUMENT ARE IN CONFORMANCE WITH BEARING CONDITIONS, ROOF PITCH
HEEL HEIGHT, OVERHANG, AND SPECIAL LOADING CONDITIONS, TO INCLUDE
BUT NOT LIMITED TO, AIR HANDLERS, LIGHT FIXTURES, AND ATTIC ACCESS
STAIRS, WHICH HAVE BEEN SPECIFIED BY RESPONSIBLE PARTYALSO THAT
FOR OR RESPANSIBLE PARTY HAVE REVIEWED AND ARE IN AGREEMENT WITH
, TRUSS PLACEMENT PLAN AND TRUSS ENGINEERING NOW PRESENTED, AND
READY MR FABRICATION. ALL DIMENTIONS @ CONDITIONS THAT EFFECT
WDOD TRUSSES MUST BE VERIFIED BY BLDR AND/OR ARCHITECT AND FOR
BEFORE ANY PRODUCTION OF WOOD TRUSSES.
imam R MR
FOR APPROVAL PURPOSES ONLY. DO NOT USE TO SET TRUSSES
UNLESS STAMPED -FINAL- HERE
REVISIONS
9/24/1II9 I 3/2/1021
Carl G.Forbes
(,
P'. E.820699
1000S: Diode HWYW.�L
qq '
1
Pompano Beach F133060
RATE
10
fsanseb Moro
SPEC BASS
FA)66bD6H M4
us TRUSS
vEWW&7WS=
vEff 4M 00 WEST W WAaUUM IfIPI
CUSTOMER
NAME Jack.Early
NAME Early Res
JOB
110851 S Ocean Drive Lot#109
Jensen Beach,FL,34957
TRUSS PLACEMENT PLAN
DATE 8/19/2019 JOB