HomeMy WebLinkAboutSt. Lucie County Roof Forms 45340 (4)
Section A (General Information)
Master Permit No. Process No.
Contractors Name: ____________________________________ License # _______________________________
Job Address
ROOF CATEGORY
Low Slope Mechanically Fastened Tile Mortar/Adhesive Set Tiles
Asphaltic Shingles Metal Panel/Shingles Wood Shingles/Shakes
Prescriptive BUR-RAS 150
ROOF ROOF TYPE
New roof Repair Maintenance Reroofing
ROOF SYSTEM INFORMATION
Recovering
Low Slope Roof Area (SF) ________ Steep Sloped Roof Area (SF) _________________
Section B (Roof Plan)
Total (SF) _______
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Total Home Roofing CCC1330489
X
SEE ATTACHED
2750430
5510 Eagle Dr Fort Pierce, FL 34951
Angi Roofing DBA Total Home Roofing
3180
Story Height: 1 Story No. Units: 1 Secondary Wall:
Interior Data
Bedrooms: 3 Electric: MAXIMUM Primary Int Wall:
Full Baths: 2 Heat Type: FrcdHotAir Avg Hgt/Floor: 0
Half Baths: 0 Heat Fuel: ELEC Primary Floors: Tile-Ceramic
A/C %: 100%Heated %: 100%Sprinkled %: N/A%
Sketch Area Legend
Sub Area Description Area Fin. Area Perimeter
BAS BASE AREA 1724 1724 218
GAA Garage Attached Average 504 0 90
PATA Patio Average (Plain Slab)364 0 82
SPAA Screen Porch Attached Average 336 0 80
SPAH Screen Porch Attached High 53 0 30
Special Features and Yard Items
Type Qty Units Year Blt
Driv-Concret 1 720 1985
CHAINLINK 4'1 196 2006
Current Year Values
Current Values Breakdown
Building:$136,800
Land:$55,900
Just/Market:$192,700
Ag Credit:$0
Save Our Homes or
10% Cap:
$86,021
Assessed:$106,679
Exemption(s):$75,500
Current Year Exemption Value Breakdown
Tax
Year
2021
Grant
Year
1999
Code
0500
Description
Homestead
Exemption
Amount
$25,000
Tax
Year
2021
Grant
Year
2008
Code
0550
Description
HomesteadExemption over $
50,000
Amount
$25,000
Tax
Year
2021
Grant
Year
2008
Code
0565
Description
Senior Homesteadover 65
Amount
$25,000
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:________________________
Product Approval No.:________________________
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1':_____ Zone 1:Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:______________________________________
Deck:
Type:___________________________________
Gauge Thickness:_________________________
Slope:__________________________________
Anchor/Base Sheet & No. df Ply(s):_______________
Anchor/Base Sheet Fastener/Bonding Material:
___________________________________________
Insulation Base Layer:_________________________
Base Insultation Size and Thickness: _____________
Base Insulation Fastener/Bonding Material:
___________________________________________
Top Insulation Layer:__________________________
Top Insulation Size and Thickness: _______________
Top Insulation Fastener/Bonding Material:
___________________________________________
Base Sheet(s) & No. of Ply(s):___________________
Base Sheet Fastener/Bonding Material:
___________________________________________
Ply Sheet(s)' & No. of Ply(s): ____________________
Ply Sheet Fastener/Bonding Material:
___________________________________________
Top Ply:_________________________________
Top Ply Fastener/Bonding Material:
Surfacing: ___________________________________
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':" oc @ Lap, # Rows
Zone 1:" oc @ Lap, # Rows
Zone 2:" oc @ Lap, # Rows
Zone 3:" oc @ Lap, # Rows
Number of Fasteners Per Insulation Board:
Zone 1':Zone 1:Zone 2:Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc. .
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 1 11 and Chapter 16.
FT.
FT.
Parapet
Height
Mean
Roof
Height
FL2533-R24
Certainteed
-60.3-34.6
Wood
-108.4
1/8”
-127.5
Flintlastic
Flintlastic
SA
SA
Flintlastic
Flintlastic
Drip Edge: 3” X 3” Galv Alum
15’
1/2"
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:Zone 2e:Zone 2n:Zone 2r:Zone 3e:Zone 3r:
Owens Corning
FL10674-R16
15’
Wood
N/A
N/A
N/A
N/A
Asphalt Shingles
1 1/4” Ring Shank Nails
6” OC Laps 12” OC Field
3” X 3” Galv Alum
-74 -74 -108 -108 -108 -128
4
YES
Weatherlock