Loading...
HomeMy WebLinkAboutAPPROVED 3150 NORTH A1A-MECHANICAL SUBMITTALJob Name: System Reference: Date: GENERAL FEATURES • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options - Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 31,400 Rated Capacity Btu/h i 22,500 ._..._.........._.__... ........... -...__..... _.............._._.... _-................. _........._.._--- - ...._._.... _J Minimum Capacity Btu/h I 8,200 .........-.... ----........ _ .... .. --..... .._.... --............... _._._..._._..-._..._—_._._.........-....... _.._... - .... __............. .... _........ _........_..--_._._......._-.._......._- -.- — Maximum Power Input W I 3,522 Cooling -- ---- ---- - _-._ Rated Power Input W 1,800 Moisture Removal Pints/h 5.1 I Sensible Heat Factor 0.75 Power Factor % 99 / 99 - SEER 20.5 Efficiency EERY 12.5 .............. _.._..... _.......... --............... ....... --...................... _.__........................ -..........._...... _..- - ...._...---._..._....._-- .................. --._.._.._......_._.... _........_... __-.._.__...... .._.. ENERGY STAR® (ENERGY STAR products are third party certified by an EPA- YES recognized Certification Body.) Voltage, Phase, Frequency I 2081230V, 1 phase, 60Hz _ Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 AC.208 / 230 ............_......— __......._.._-.._...... —...........___._...-.__..........-----.._._......._........._.-................. : .......__.......... ..-; Electrical Voltage: Indoor- Outdoor, S2-S3 V DC 24 _.............. --. - - -........_._._._......._._..._..._._......... Voltage: Indoor - Remote Controller 1 Wireless Type I Recommended FuseBreaker Size A 20 I Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A i 0.76 —.__...._.:._...:_..__._........................... ----._ Blower Motor Output _...---------- ........- -, ......_..-...--.....__..._-.._..............--_ ......_......_.-.... W 56 _...._......__......_..................— -- -. —..... --.. Airflow Rate at Cooling, Dry __ _........... ---.........._....._ - - ----......._.................................. - ---._. CFM 738-628-544 469-388 Airflow Rate at Cooling, Wet CFM _ �_— 661-562-487-420-347 Sound Pressure Level (Cooling) dB(A) 53-49-45-41-34 Drain Pipe Size In. (mm) 5/8 (15.88) j Heat Exchanger Type Plate fin coil Indoor Unit -- -- - External Finish Color Munsell 1.OY 9.2/0.2 W: In. (mm) 43-5/16 (1,100) ...... -----...._................ Unit Dimensions -- —.... -— ......... —_i D: In. (mm) 9-3/8 (238) -_ - ---- - —'------------- H: In. (mm) �_ 12-13/16 (325) W: In. (mm)~ 45-1/2 (1,160) Package Dimensions D: In. (mm) 12-3/4 (320) i H: In. (mm) 15-1/2 (390) -_ Unit Weight Lbs. (kg) 37 (17) Package Weight Lbs. (kg) - 37 (17) ---......_.........--........................__............... -----------......................... -- ..... ---------............. _-.._..... _..... ........- Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)" ._._..-----—_......... __..... ..._--............... _.__....... __............ __.... _-._ _...._...._ °F 90 DB, 73 WB 167 DB, 57 WB Temperature Range MCA — A 17.1 -- Outdoor Unit MOCP .... _._....... _. A 20 i Fan Motor Full Load Amperage A 0.93 Specifications are subject to change without notice. 0 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. --......_......._.._........... _._...... _..._..--.._....._._._......_._._.....- _ -- --.... _...... _... ...... _-- ....._..... _...__...� Fan Motor Output I W 77 - I} Airflow Rate CFM j 1,769 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil i-- Sound Pressure Level, Coolingi dB(A) 55 Compressor Type DC INVERTER -driven Compressor Model SNB172FQKMT - ,._......... - ... - ..... --- ............... --------.._..- __............ -.... _.... .....----....-t.--..._..... Compressor Rated Load Amps A 12.9 ; Compressor Locked Rotor Amps A j 16.1 j Compressor Oil Type // Charge oz. FV50S // 13.5 External Finish Color i Munsell 3Y 7.8/1/1 Base Pan Heater I N/A - W: In. (mm) I 33-1/16 (840) Unit Dimensions D: In. (mm) 13 (330) ... ........ _........................ -_.._...._...... -.._............ _.--_....................... .......... -...... _.__...._............ __.._... H: In. (mm) 34-5/8 (880) WIn. (mm)-� 38-9/16 (980) Package Dimensions D: In. (mm) 16-9/16 (420) H: In. (mm) 39 (990) Unit Weight Lbs. (kg) 119 (54) Package Weight Lbs. (kg) 139 (63) ...... ......... ........ ...---._...............................- -- -.._-. _...--....... ....._.. ...... Outdoor Unit Operating Cooling Air Temp (Maximum / Minimum)* -F j 115 / 14 Temperature Range �- ...._....---...---....._...._.._...........__........_.. ---- ....--...__......_...----- - p g -i Cooling Thermal Lock -out / Re -start Temperatures- °F -4 / 0 i -.._ Type i R410A Refrigerant �- - --- - - ---_-..- - Charge Lbs, oz 4,3 Gas Pipe Size O.D. (Flared) In. (mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Piping Maximum Piping Length Ft. (m) 100 (30) Maximum Height Difference 50 (15) _... -....... -..... _...... ----...... ---- ..................._.... _..__._................. - - - - -----.._......_._.__ _ ._.........._.......--- Maximum Number of Bends 10 -------.............. _...__..-_._...:--........... _.._............. -.............. _......................... _..... __........ _.................... _..... - - ..._......-. -. _..._....... _.......... _.___-._...^_.._.._..... ........... _..........__..._ Notes -........ .... ..... ----- -- - - _....----- AHRI Rated Conditions lCooling (Indoor // Outdoor) "F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) i *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. -System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. i Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter MAC-2310FT-E Backlit, Wall -mounted, Wireless Controller ❑ MHK1 Portable Central Controller MCCH1 Wired MA Controller' o PAR-33MAA Simple MA Controllers ......... . .......... . ... . ............. . . ...... . .... . ...... . . . . . ....... . . . ...... Touch MA Controller' n PAC-YT 3CRAU . ......... _J o PAR-CT01MAU--SB Wireless Temperature and Humidity Sensor o PAC-USVVHS003-TH-1 Outside Air Sensor for MHK1 ❑ most System Control Interface2 o MAC-3331F-E Wireless Interface o PAC-USWHS002-WF-1 Thermostat Interface o PAC-US444CN-1 kumo station® .... . .. . . ............. ............................. . __ ........ . .... - ------- .... . . . . ......... . . . ..... . . ................ . ........... . . .. . . . ............ . . .......... . . . USNAP Interface - - - -------------------------- . . ................. . . . . .. . ... . ... . . . . . .............. . ....... ... . . . .......... . ... .... IT Extender o PAC-WHS01HC-E ................. ............. . . . . - ---- ------------ 0 PAC-WHS01UP-E ......... 1____ .. . . . . ....... . . ............. o PAC-WHS01IE-E BACnet4D and MODBUSID Interface o PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers c RCMKP1CB Blue Diamond Sensor Extension Cable — 15 Ft. o C13-103 Blue Diamond Alarm Extension Cable — 6.5 Ft. i o C13-192 Blue Diamond MultiTank— collection tank for use with multiple pumps o C21-014 ....... ... . ...... ­­ ­..._..._..__..____­. . ..... .... . ..... . ..... . . . . . . . ...... . ............................. .... Blue Diamond Rubber Foot Pads o F1 0-010 ........... ...... . ... . ........ Mini Condensate Pump-230 volt application o S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor . ........ . . . . .. . . . . ........................ . ....... .. . . . . . ....... - ------------ ------------- -1 o X87-835 - 110 to 250V --- MaxiBlue Advanced Blue Diamond Mini Condensate Pump wl Reservoir & Sensor (11 OV) up to 48,000 Btu/h [recommended] in X87-711 - 11 OV . . ............ . . ........................ . Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] . . . . . . ........ . .............. . .......... . ............... . . ..... . ... . ........................ . . .. MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btuth I o X87-721 - 2081230V . ........... .. . ... . .............. o X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit o T18-016 Drain Pan Level Sensor o DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black j o TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White . ............. o TAZ-MS303W I Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. @ 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide I o MAC-886SG-E Drain Socket o MAC-860DS Hail Guard o HG-A7 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic j o DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" . ..................... . ...... . ......... . ....... . . .... ...... ................. ___ . ........ . .. . ....... .... . . .................. . .. Outdoor Unit Stand 12" High ❑ ULTRILITE1 . ......... . ...... . ........... . ........ . QSMS1 201 M Outdoor Unit Stand 18" High ❑ QSMS1 801 M Outdoor Unit Stand 24" High L],Q'i'MS2401M Heavy Duty Wall Mounting Bracket —Coated Steel I o QSWB2000M-1 Heavy Duty Wall Mounting Bracket— 316 Series Stainless Steel . QSWBSS 1 O'x 3/8" x 1 O'x 5/8" Lineset (Twin -Tube Insulation) 15'x 3/8" x 15'x 5/8" Lineset (Twin -Tube Insulation) . ...... . ... . ........... . ........ . ............. .. __ . . . . . . ... . ........... . ............... . . . . . . ................ . ... . ..... .. 30'x 3/8" x 30'x 5/8" Lineset (Twin -Tube Insulation) 50'x 3/8" x 50'x 5/8" Lineset (Twin -Tube Insulation) . o MPL5385812T-10 o MPLS385812T-1 5 . . ....... . ........ . . ...................... . . .............. . .... . . . ..... ... . ....... . . . ........... ----- -------- .......... . . ------- ❑ MPLS385812T-30 ❑ MPLS385812T-50 . . . . . . ............... 65'x 3/8" x 65'x 5/8" Lineset (Twin -Tube Insulation) . ❑ MPLS385812T-65 ........... ..... . ... ....... 1 00'x 3/8" x I 00'x 5/8" Lineset (Twin -Tube Insulation) o MPLS385812T-100 Specifications are subject to change without notice. @ 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cm ■i1 �iiii' Unit: inch �® Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE *1 20 in. or more when front and sides of the unit are clear N [7 tf) N n FORM# MSY-GL24NA / MUY-GL24NA - 201902 Unit: inch and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (Flared) o 1/4 (18 kBtulh) Refrigerant pipe (Flared) o 3/8 (24 kBtu/h) Gas refrigerant pipe joint Refrigerant pipe (Flared) o 1/2 (18 kBtu/h) Refrigerant pipe (Flared) o 5/8 (24 kBtulh) AkMITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800.433-4822 www.mehvac.com Eilr . Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.