Loading...
HomeMy WebLinkAboutAPPROVED 3150 NORTH A1A-NOA 21-1012.03 BRACKETCOtJNTyx MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade,eov/economy RectorSeal, LLC 2601 Spenwick Drive Houston, TX 77055 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER — Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Hurricane Rated Wall Steel Condenser Bracket APPROVAL DOCUMENT: Drawing No 08-03739, titled "Hurricane Rated Wall Condenser Bracket", sheets 1 through 4 of 4, dated 07/12/2021, prepared by L. Roberto Lomas, P.E., signed and sealed by Luis R. Lomas, P.E. on 12/02/2021, bearing the Miami —Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 19-0411.04 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P. E. MIAMI•DADE COUNTY NOA No. 21-1012.03 Expiration Date: October 6, 2026 Approval Date: January 6, 2022 Page 1 RectorSeal, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under NOA # 15-0820.06 A. DRAWINGS 1. Drawing No RS1508-1, titled "Wall Condenser Bracket", sheets 1 through 4 of 4, dated 08/26/2016, prepared by Ted Berman and Associates, LLC, signed and sealed by Theodore Berman, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014, 51h edition, prepared by Ted Berman and Associates, LLC, signed, and sealed by Theodore Berman, P.E., dated 08/17/2016 and revised 09/08/2016. D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance and of no financial interest, issued by Ted Berman and Associates, LLC, dated 08/17/2015, signed and sealed by Theodore Berman, P.E. G. OTHERS 1. None. E-1 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 21-1012.03 Expiration Date: October 6, 2026 Approval Date: January6, 2022 RectorSeal, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. Evidence submitted under NOA # 19-0411.04 A. DRAWINGS 1. Drawing No RS1508-1, titled "Wall Condenser Bracket", sheets I through 4 of 4, dated 04/05/2019 and 08/26/2016, prepared by Ted Berman and Associates, LLC, signed and sealed by Theodore Berman, P. E. on 04/05/2019 and 09/07/2016. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 61' edition (2017) of the FBC and of no financial interest, issued by Ted Berman and Associates, LLC, dated 04/05/2019, signed and sealed by Theodore Berman, P.E. G. OTHERS 1. None. E-2 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 21-1012.03 Expiration Date: October 6, 2026 Approval Date: January 6, 2022 RectorSeal, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. New evidence submitted A. DRAWINGS 1. Drawing No 08-03739, titled "Hurricane Rated Wall Condenser Bracket", sheets 1 through 4 of 4, dated 07/12/2021, prepared by L. Roberto Lomas, P.E., signed and sealed by Luis R. Lomas, P.E. on 12/02/2021. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations, prepared by L. Roberto Lomas, P.E., dated 09/27/2021, signed and sealed by Luis R. Lomas, P.E. D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 7`h edition (2020) of the FBC and of no financial interest, issued by L. Roberto Lomas, P.E., dated 09/27/2021, signed and sealed by Luis R. Lomas, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 21-1012.03 Expiration Date: October 6, 2026 Approval Date: January 6, 2022 E-3 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REOUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 3. BRACKET MATERIAL: STEEL WITH Fy-59KSI, AISI 1045 STEEL OR BETTER. 4. FOR ANCHORING INTO WOOD FRAMING USE 1/4" LAG SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 2 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 5. FOR ANCHORING INTO MASONRY/CONCRETE USE 1/4" TAPCONS. LOCATE ANCHORS AS SHOWN IN ELEVATIONS INSTALLATION DETAILS. 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm-2,000PSI MINIMUM. 7. ALL SCREWS AND FASTENERS SHALL BE CORROSION RESISTANT. PRODUCT REVISED as complying with the Florida Building Code NOA-No. 21-1012.03 TABLE OF CONTENTS Expiration Date 10/06/2026 SHEET NO. DESCRIPTION A o By -/ 1 NOTES 2 ELEVATION Miami -Dade Product Control 3 INSTALLATION DETAILS 4 COMPONENTS REVISIONS DESCRIPTION DATE I APPROVED REVISED PER MD COMMENTS 1 12/01/20211 R.L. SIGNED: 1210212021 RECTORSEAL 2601 SPENWICK DRIVE \�\ �5 R; LO,y HOUSTON, TX 77055 VJ' VCENS,, _ No. 62514 HURRICANE RATED WALL CONDENSER BRACKET WBB500HR = NOTES 0, STATE OF DRAWN: DWG N0. REV A.R. OS-03739 A F '' %�S �?ORIo�.•'G�? "'i,,ZONAL 0%\\\ Luis R. Lomas P.E. scuE NTS DATE 07�12�2021 SNEETI OF 4 LR09ERTOLOAI4SP.E 1432 WOODFORD RD LEMSVALE, AC 27027 434-668-OSM r1bm�bbrtwo..mm fL No.: 62514 o / I \ b CONDENSN R � \ \ / 23 5/8" c 2 33 1 /2" WALL CONDENSER BRACKET REVISIONS REV DESCRIPTION —E APPROVEO A REVISED PER MD COMMENTS 12/01/2021 R.L. CONDENSER TO BE INSTALLED W ITH BRACKET DIMENSION SIGUNT IMEDIUM UNIT SMALL UNIT e In 17' 12' 11' b(in) 45' 34' 18' c (in) 42' 35' 26" WelgN 5001bs I 3181bs I 150lbs BILL OF MATERIALS ITEM NO.- DESCRIPTION QUANTITY MATERIAL PARTNUMBER 1 CROSSBAR 1 1045# G90 GALVANIZED STEEL 0.078" THICK FABOO914 2 VERTICAL ARM 2 10459 G90 GALVANIZED STEEL 0.078" THICK FABOO896 3 HORIZONTALARM 2 1045# G90 GALVANIZED STEEL 0.078'THICK FAB00915 4 ANGLE ARM 2 1045# G90 GALVANIZED STEEL 0.078"THICK FABOO920 5 M8 X65 MM HH BOLT 4 GALVANIZED STEEL GRADE 4.8 STKO0129 6 NO FLAT WASHER 20Md OD IIAW THICK 4 GALVANIZED STEEL GRADE 4.0 STKO0130 7 MS LOCK NUT 4 IGALVANIZED STEEL GRADE 4.8 STKO0131 8 MB ADJUSTMENT BOLT 2 IGALVANIZED STEEL GRADE 4.8 AS BOO 190 9 CLEAN CLIP WITH NUT 4 PVC ASBOO189 10 RUBBER MOUNT 4 TPUIFLEXIBLE PVC FAB00632 11 M10 X65 MIA HH BOLT 2 GALVANIZED STEEL GRADE 4.8 STKO0195 12 M10 FLAT WASHER 20MMOD 2MM THICK 2 GALVANIZED STEEL GRADE 4.8 STK00194 13 M10 LOCK NUT 2 GALVANIZED STEEL GRADE 4.8 STK00196 PRODUCT REVISED as complying with the Florida Building Code NOA-No. 21-1012.03 Expiration Date 10/06/2026 By ,:o Miami -Dade Product Control RECTORSEAL 2601 SPENWICK DRIVE HOUSTON, TX 77055 HURRICANE RATED WALL CONDENSER BRACKET WBB500HR ELEVATION A.R. 1 08-03739 srxE NTS I DATE 07/12/2021 1SHEE72 OF L ROBERTO LCMAS P.E. 1432 WOODFORD RD LEWISVXLE, NO 27023 434-688-0609 rll=m _Tkbmaspe.n SIGNED: 1210212021 ... :.LOM 4\CENSF'.'gS i No.6 514 �0' STATE OF [V-� COR101" �G\? V7, 0NAL'10111110%11•• Luis R. Lomas P.E. FL No.: 62514 SEE CHART #1 1RT # 1 HEET ;E DISTANCE #1 T ANCHORS LOCATIONS NOTE OTHER ANCHORS MAYBE USED AS LONG AS ANCHOR CAPACITIES EXCEED CAPACITIES SHOWN IN CHART Nf Chart N1 ANCHOR MANCHORS ANCHORCAPACITY DESIGN MIN. MIN. ANCHOR SUBSTRATE TYPE PER TOTAL TENSION SHEAR PRESSURE EDGE EMBEDMENT LOCATIONS (IDs) (IDs) (p DISTANCE 1/4' Leg 3 8 74.2 A, C 8 E Woad Screw 4 8 441 236 112.5 5/8' 2 1/2' A, B. D & E 5 10 150.0 A,B,C.DBE 114" 3 B 25.6 A, C 8 E Hollow CMU Tapcon 4 8 118 202 40.2 4 1 114' A. B. D & E 5 10 54.7 1 A,B.C,DBE Concrete or 114' 3 6 113.9 A. C & E Grout filled Topcon 4 B 443 421 150.0 3 1 1 3/4' A. B, D & E CMU 5 10 1 150.0 A R. C D a E REVISIONS REV DESCRIPTION I IATE AP .T D A REVI5ED PER MD COMMENTS 1 12/01/2021 R.L. PRODUCT REVISED as complying with the Florida Building Code NOA-No. 21-1012.03 Expiration Date 10/06/2026 By ^- Miami -Dade Product Control SIGNED: 1210212021 RECTORSEAL �oI'''%, 2601 SPENWICK DRIVE �•` v\ 4t , HOUSTON, TX 77055 V.•0CEN@f'•.•s — No. 62514 HURRICANE RATED WALL CONDENSER BRACKET WBB500HR =_ INSTALLATION DETAILS E OF � O STATE OF ((/� DRAWN: Dwc No. REv A.R. 08-03739 i •�`G��� �/S10NAL10`1_��`� SCALE DATE SHEET3 NTS 07/12/2021 OF 4 Lu's R. Lomas P.E. FL No.: 62514 L ROBERTO LOMAS RE 1422 WOODFORD RD LEVISVl1.lE, AC 27023 434-688-0609 rlb—Ok—gw.mm REVISIONS REV DESCRIPTION DATE I APPROVED A REVISED PER MD COMMENTS 1 12/01/2021 R.L. 1 3/4" —} ] 33 1/2- TA L 7/16" J O O O O O O O 1 3/4' Oi CROSS ARM —r 1/2" � 17 3/4" L 2 1/6" F O O O O 01 O f z ,/2" o � O2 VERTICAL ARM 2 5/I 16" 23 9/ 16" 1 15/16" F 1 15/16" 26 7/16" Q 1 1/2" —r 23 7/8" 1 1/2" O H 1 9/16" O ANGLEARM —r T 2 3/16" ° O3 HORIZONTAL ARM PRODUCT REVISED as complying with the Florida Building Code NOA-No. 21-1012.03 Expiration Date 10/06/2026 By 0 Miami -Dade Product Control SIGNED: 1210212021 RECTORSEALlLo 2601 SPENWICK DRIVEJ\5,....._4 tj HOUSTON, TX 77055 HURRICANE RATED WALL CONDENSER BRACKET = No.0251,/ WB8500HR COMPONENTS :A-;fw�DRAWN: DWG NO. REV STATES A.R. 08-03739 A ' SME NTS DATE 07/12/2021 SHEET4 OF 4 'i,, ZONAL L ROBERTO LOMASRE. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVLE, AC 27073 FL No.: 62514 I31-me-06M Illomwokt—P.,00m