HomeMy WebLinkAboutAPPROVED, 3150 NORTH A1A-ELECTRICAL PLANSAUSTEN ENT ISES INC. Austen EI ric Inc. &Austen Air Conditioning Inc. 6200 W j 1ST CT P H IALFAH FiA 33016 Off i c F EC 13001529 JC SHAWN CR CAC 1817770 RICHARD A. CARRY 5 805 8166 30 PROJECT NAME iara Tower 150 N AlA Ft Pierce Fl, 34949 21-024 To Elevator Equipment 1 1 /4" C 3#3 14 8 GND 100k AIC 100k AIC TO ELEVATOR EQUIPMENT 100 100 1/2" C .100 .100 3 # 12 250V 250V 130 130 LLX 3 X 15 15 1 1 /2" C===j 3#2 New Car 1 New Car 2 1#8GND 1/2"C 3#12 EXISTING A/C RISER DIAGRAM EMDP PNL 1-Carl 125 amp INSIDE MACHINE ROOM OUTSIDE MACHINE ROOM 2- Car 2 125 amp 3- Cab Lt 1 20 4- Cab Lt 2 20 A H U 5- Machine rm a/c 20 NO HEAT 208V 3ph WIRELESS 300A ML O r� ACU 1/2"C4#12 THHN 30 215 1 /2" C 4# 12 THHN 1/2�12Gnd 30 n 3 #Cu 1 # �-7 JB LV f' Conduit Nema 3R 2 # 12 Thhn Cu 1 # 12 Gnd GFCI WP RT RECEPTACLE I GFCI ELEVATOR MACHINE ROOM LAYOUT NTS Existing Ckt to Reuse Home Pnl ckt 10 411 LED vapor Proof Wrap Note : This it layout is typical of both cars. 1 & 2 SINGLE CAB ELEV. PIT NTS FEED FROM House Pnl CT# 20 4ft LED vapor Proof Wrap SCOPE OF WORN 1. Replace Main Line Safely Switch 2. Replace Cab Car Safety Switch. 3. Replace GFCI in Hoist way pit. 4. Replace GFCI in Machine room - 5. Replace lights in hoist way pit. 6. A/C connections JC Shawn Crow Digitally signed by JC Shawn Crow Date: 2022.02.18 13:58:30-05'00' AUSTEN ELECTRIC INC. 6200 W 21 ST CT HIALEAH, FL 33016 305-805-8166 305-805-8190 FAX EC 13001529 Drawn By: JCSA Tiara Tower 3150 N A1A Fort Pierce, FL 34949 21-024 FBC 2020 7th Edition —•—•--- BY OTHERS DATE 12/27/21 E 1 NATIONAL ELECTRIC CODE 2017 REUSE EXISTING NTS ELEVATORS 1 & 2 N.T.S. NEW / REPLACE CONDENSER AIR HANDLER MFG: MITSUBISHI MGF: MITSUBISHI MUY-GL24NA-U1 MSY-GL24NA-U1 BTU : 22,500 NO HEAT MAX BREAKER: 20 AMP MAX BREAKER: 20 AMP COPPER LINES CFM : 738 3/8 & 5/8 SEER 20.5 ATTACHED SEE WIND LOAD CALCULATION FOR CONDENSER & CONDENSER STAND MOUNTING BY ENGINEER. ROC NOT LESS THEN 12" 1 ROOF LEVEL FBC 2020 7th Edition 738 CFM Machine room Layout NTS 3/8" COPPER LIQ. LINE AHU �ll ii II 5/8 COPPER SUC. LINEII II 3/4" PVC DRAIN LINE--)) ACU ELEVATORS 1 & 2 N.T.S. U AIR HANDLER N.T.S. WATER LEVEL MONITORING 3/4 PVC DEVICE AS PER DRAIN TO ROOF DRAIN FBCM 307.2.3.1 CONDENSOR LOCATED ON MOUNTED ON ROOF EXTERIOR WALL OF MACHINE ROOM ON WALL BRACKET DUCT SCHEDULE N/A OPEN RETURN HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR X FIRE DAMPER X SMOKE DAMPER X FIRE RATED ROOF / FLOOR X FIRE RATED ENCLOSER X FIRE STOPPING X SMOKE CONTROL X ISCOPE OF WORKI 1. INSTALL (1) 2TON MINI SPLIT SYSTEM IN ELEVATOR MACHINE ROOM. Richard A Curry Digitally signed by Richard A Curry Date: 2022.02.18 14:06:54-05'00' AUSTEN A/C INC. 6200 W 21 ST CT HIALEAH, FL 33016 305-805-8166 305-805-8190 FAX CAC 1817770 Drawn By: JCSA Tiara Tower 3150 N A1A Fort Pierce, FL 34949 21-024 01 DATE 12/27/21 NTS IM 1 FBC 2020 7th Edition NATIONAL ELECTRIC CODE 2017 Work Location Machine room SCOPE OF WOR 1. Replace Main Line Safety Switch, 2. Replace Cab Car Safely Switch. 3. Replace GFCI in Hoist way pit. 4. Replace GFCI in Machine room . 5. Replace lights in hoist way pit. 6. A/C connections JC Shawn Crow Digitally signed by JC Shawn Crow Date: 2022.02.18 13:59:09-05'00' AUSTEN ELECTRIC INC. 6200 W 21 ST CT HIALEAH, FL 33016 305-805-8166 305-805-8190 FAX EC 13001529 Drawn By: JCSA Tiara Tower 3150 N A1A Fort Pierce, FL 34949 21-024 DATE 12/27/21 �NTS�L-1 Z 1 1