Loading...
HomeMy WebLinkAboutAPPROVED 3120 NORTH A1A-ELECTRICAL PLANS AUSTEN ENT ISES INC . A71H Elric Inc. & Aus /en Air Conditioning Inc. 200 W 1 / CT IAL AH 33016 Offic 5 805 8166 F 3058 51 0 PROJECT NAME EC 13001529 JC SHAWN CR Tiara Tower CAC 1817770 RICHARD A. RRY 3120 N AlA Fort Pierce, FL 34949 21 -024 To Elevator Equipment 1 1/4"C 3#3 ELEVATOR MACHINE ROOM LAYOUT NTS 1#8GND 100k AIC 100k AIC TO ELEVATOR EQUIPMENT 100 100 G SCOPE OF WORK 1/2"C 3100 3100 3#12 —. _ _ _ 1. Replace Main Line Safely Switch. — 1 2. Replace Cab Car Safety Switch. 3. Replace GFCI in 250V 250V J1O5 J 4. Replace GFCI in Matst chne room. way pit. 0 0 5. Replace lights in hoist way pit.3 3 6. A/C connections 3#2 1 2"C New Car 1 New Car 2 1 #8 GND 1/2"C 3#12 0 0 0 EXISTING A/C RISER DIAGRAM EMDP PNL GFCI 1-Carl 125 amp INSIDE MACHINE ROOM OUTSIDE MACHINE ROOM 101 on J C Shawn 2-Car 2 125 amp 3-Cab Lt 1 20 4-Cab Lt 2 20 Crow 5-Machine rm a/c 20 A H U NO HEAT Existing Ckt to Reuse 208V 3ph WIRELESS Home Pnl ckt 10 300AML O Digitally signed by JC Shawn Crow 4ftLEDvaporProofWrap A C u Date: 2022.02.18 1l2"C4#12 THHN 3� 71— 12:50:28-05'00' vz ca#,zTHHN Note:This it layout is typical of both cars. 1 &2 12'.conduit 3#12 Thhn Cu 20 SINGLE CAB ELEV. PIT NTS AUSTEN ELECTRIC INC. 1#12 Gnd Jg 6200 W 21 ST CT XISTING FEED FROM House Pni CT#20 H IALEAH, FL 33016 }"Conduit N—a 3R 305-805-8166 2#12 Thhn Cu 1#12 Gnd GFCI WP RT RECEPTACLE GFCI 305-805-8190 FAX EC 13001529 4ft LED vapor Proof Wrap Drawn By:JCSA Tiara Tower 3120 N A1A Fort Pierce,FL 34949 21-024 FBC 2020 7th Edition —•—•—•— BY OTHERS DATE 12/27/21 E 1 NATIONAL ELECTRIC CODE 201.7 REUSE EXISTING NTS ELEVATORS 1 & 2 N.T.S. NEW / REPLACE CONDENSER AIR HANDLER MFG: MITSUBISHI MGF: MITSUBISHI M UY-GL24NA-U 1 MSY-GL24NA-U 1 BTU : 22 500 NO HEAT 738 MAX BREAKER : 20 AMP MAX BREAKER : 20 AMP CFMLL U COPPER LINES CFM : 738 3/8 & 5/8 SEER 20.5 — / Austen ACInc. � SCOPE OF WORK �.— 1.INSTALL(1)2TON MINI SPLIT SYSTEM IN ATTACHED AIR HANDLER ELEVATOR MACHINE Machine room Layout NTS N.T.S. ROOM. SEE WIND LOAD CALCULATION FOR CONDENSER&CONDENSER STAND MOUNTING BY ENGINEER. WATER LEVEL ROOF DRAIN MONITORING 3/4 PVC DEVICE AS PER DRAIN TO ROOF DRAIN GON N.T.S SER FBCM 307.2.3.1 Richard A/H COND CONDENSOR LOCATED ON A Curry MOUNTED ON ROOF EXTERIOR WALL Digitally signed by OF MACHINE ROOM ON WALL BRACKET Richard A Curry Date: 2022.02.18 DUCT SCHEDULE 12:53:48 -05'00' N/A OPEN RETURN 3/8" COPPER LIQ. LINE U AUSTEN A/C INC. AHU _ _ _ _ HVAC DESIGN REQUIRES YES NO 6200 W21STCT T l DUCT SMOKE DETECTOR X HIALEAH, FL 33016 FIRE DAMPER X 66 NOT LESS THEN12" �: 11 305-805-81 FAX 9 ll II SMOKE DAMPER X CAC 1817770 1 / FIRE RATED ROOF / FLOOR X Drawn By: JCSA ROOF LEVEL ii 5/8 COPPER SUC. LINEII II FIRE RATED ENCLOSER X FIRE STOPPING X 3/4 PVC DRAIN LINE—� Tiara TowerJ SMOKE CONTROL X 3120NA1A — _ Fort Pierce,FL 34949 AC U 21-024 DATE 12/27/21 M 1 FBC 2020 7th Edition TS ELEVATORS 1 & 2 N.T.S. �. %1 SCOPE OF WORK a I ( al 1. Replace Main Line Safely Switch. 2. Replace Cab Car Safety Switch. � 'q " 3. Replace GFCI in Hoist way pit. r Machine room 4. Replace GFCI in Machine room. �,'}• t �, 5. Replace lights in hoist way pit. _ PA i • 4 6. A/C connections JC Shawn ;. •� Crow t ate• Digitally signed by JC Shawn Crow ar V. Date: 2022.02.18 e 12:50:59 -05'00' AUSTEN ELECTRIC INC. 1 '�$•�.• 6200 W 21 ST CT HIALEAH, FL 33016 ti 305-805-8166 y�r...} 305-805-8190 FAX EC 13001529 r..�..� Drawn By:JCSA Tiara Tower 3120 N Al Fort Pierce,FL 34949 21-024 FBC 2020 7th Edition DATE 12/27/21 NATIONAL ELECTRIC CODE 2017 Work Location NTS