HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 13945 CEDROFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. LUcle(Florlda Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(1718.3 sgft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0 240,00 ft
3. Number of units, if multiple family
1
c. NIA
R= ft2
4. Number of Bedrooms
1
d. NIA
R= ft2
5. Is this a worst case?
Yes
11, Ceiling Types(1336.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft2)
1306
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2)
0
c. NIA
R= ft2
7. Windows(128.9 sqft.) Description
Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Sgl, U=1,02
76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 120
SHGC: SHGC=0.29
b.
b, U-Factor: Sgl, U=1,03
40.00 ft2
c,
SHGC: SHGC=0.27
13. Cooling Systems
kBtulhr Efficiency
c. U-Factor: Sgl, U=1.02
12.85 ft2
a. Central Unit
29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 ft
Area Weighted Average SHGC:
0.281
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
27.0 HSPF:8.20
U-Factor:(AVG) NIA
NIA ft2
SHGC(AVG): NIA
15. Hot Water Systems
9. Floor Types Insulation
Area 2
a. ElectricTankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R= 0.0
1306.00 ft2
EF: 0.600
b. NIA R=
ft
b. Conservation features
c. NIA R=
ft2
None
16. Credits
None
GiasslFloor Area: 0.099 Total Proposed Modified Loads: 41.30
PASS
Total Baseline
Loads: 43.21
hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida
Energy
specifications covered by this
gifts
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED 8Y:
Before construction is completed
this building will be inspected for
DATE: 6-7-2021
compliance with Section 553.908
Florida Statutes.
'
we
I hereby certify that this building, as designed, i compliance1^,O
with the Florida Energy C te��w
-c
OWNE EST:
BUILDING OFFICIAL:
DATE:- �
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 111403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSIIRESNET)ICC 380, is not greater than 0.000 Qn for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE COTTAGE IMPACT
Addresstype:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
---
Owner: WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDivision:
---
Total Stories: 1
PlatBook:
---
Builder Name: WYNNE BUILDING CORP.
Worst Case: Yes
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St. Lucie
Jurisdiction:
CrossVentilation: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
VDesign
Design Temp
Int Design Temp
Heating
Design
Dailytemp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
_FL, Fort Pierce
FL_VERO-SEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13K076.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_ 1 MASTER BEDROOM
234
1895.4 No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINK AREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_5 GREAT ROOM
452
3661.2 No 2
Yes
Yes
Yes
8 MASTER BATH
50
406 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
1879.2 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# FloorType
Space
Exposed Perim Perimeter R-Value Area U-Factor JoistR-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234 It 0.473
---
0.00
1.00 0.00
-2 Slab -On -Grade Edge Ins
DEN
24 0
144 ft 0,473
--
0.00
1.00 0.00
_ 3 Slab -On -Grade Edge Ins
SINK AREA
7 0
42 ft 0.473
---
0.00
1.00 0.00
_ 4 Slab -On -Grade Edge Ins
CLOSET
1 0
63 ft 0.473
---
0.00
1.00 0.00
_ 5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452 ft 0.473
---
0.00
1.00 0.00
_ 6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50 ft 0.473
--
0.00
1.00 0.00
_7 Slab -On -Grade Edge Ins
POWDER
1 0
25ft 0.473
--
0.00
1.00 0.00
_ 8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232 ft 0.473
---
0.00
1.00 0.00
_9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40it 0.473
--
0.00
1.00 0.00
10 Slab -On -Grade Edge Ins
STORAGE
21 0
24 it 0.304
-
0.00
0.00 1.00
6/7/2021 11:47:00 AM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof Gable Roof
Red Solar
SA Emitt Emitt
Deck Pitch
V# Type
Materials Area Area Color
Barr Absor. Tested Tested
Insul. (deg)
_ 1 Hip
Metal 1376 ft2 0 ft2 Light
N
0.6
No 0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area
RBS
IRCC
1 Fullattic
Vented 150 1306 ft2
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# CeilingType
Space R-Value Ins.Type
Area
U-Factor Framing Frac.
Truss Type
-1 UnderAttic(Vented)
MASTER BEDROOM 30.0 Blown
234.0ft2
0.053
0.10
Wood
_2 UnderAftic(Vented)
DEN 30.0 Blown
144.oft2
0.053
0.10
Wood
_3 UnderAftle(Venfed)
SINK AREA 30.0 Blown
42.0ft2
0.053
0.10
Wood
_4 UnderAttic(Vented)
CLOSET 30.0 Blown
63.0ft2
0.053
0.10
Wood
_5 UnderAttic(Vented)
GREAT ROOM 30.0 Blown
452.Oft2
0.053
0.10
Wood
8 UnderAttic(Vented)
MASTER BATH 30.0 Blown
50.0ft2
0.053
0.10
Wood
_7 UnderAttic(Vented)
POWDER 30.0 Blown
25.0112
0.053
0.10
Wood
B UnderAftio(Vented)
KITCHEN 30.0 Blown
232.0112
0.053
0.10
Wood
_9 UnderAftic(Venfed)
LAUNDRY 30.0 Blown
40.0ft2
0.053
0.10
Wood
_ 10 UnderAttic(Vented)
STORAGE 30.0 Blown
24.Oft2
0.030
0.11
Wood
11 Knee Wall(Vented)
GREAT ROOM 19.0 Blown
30.0ft2
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation Is modified by the rotate angle (180 degrees) as shown in the "Project' section on page 1.
Cavity Width
Height
Area
U- Sheath Frm.
Solar Below
JAdjacent
# Ornl To
Wall Type
Space R-Value Ft In
Ft In
sq.ft.
Factor R-Value Free.
Absor. Grade
_ 1 S=>N Exterior
Cone. Bik- Int Ins
MASTER BEDROOM 4.1 18.0 0
8.0 1
145.5
0.149 0 0
0.30 0%
_2 W=>E Exterior
Cone. Elk - Intins
MASTER BEDROOM 4.1 13.0 0
8.0 1
105.1
0.149 0 0
0.30 0%
_3 N=>S Exterior
Cone. Bik -Int Ins
DEN 4.1 12.0 0
8.0 1
97.0
0.149 0 0
0.30 0%
_4 W=>E Exterior
Conc. Bik- Int Ins
DEN 4.1 12.0 0
8.0 1
97.0
0.149 0 0
0.30 0%
_ 5 S=>N Exterior
Cone. Elk- Int Ins
SINK AREA 4.1 7.0 0
8.0 1
56.6
0.149 0 0
0.30 0%
_ 6 N=>S Exterior
Cone. Elk- Int Ins
GREAT ROOM 4.1 22.0 0
8.0 1
177.8
0.149 0 0
0.30 0%
_ 7 W=>E Exterior
Cone. Elk- Int Ins
GREAT ROOM 4.1 10.0 0
8.0 1
80.8
0.149 0 0
0.30 0%
_ 8 S=>N Exterior
Cone. Bilk - Int Ins
MASTER BATH 4.1 5.0 0
8.0 1
40.4
0.149 0 0
0.30 0%
_9 N=>S Exterior
Conc.Blk- IntIns
KITCHEN 4.1 17.0 0
8.0 1
137.4
0.149 0 0
0.30 0%
_ 10 E=>W Exterior
Conc. Bilk - Int Ins
KITCHEN 4.1 16.0 0
8.0 1
129.3
0.149 0 0
0.30 0%
_ 11 S=>N Exterior
Conc. BIk- Int Ins
KITCHEN 4.1 5.0 0
8.0 1
40.4
0.149 0 0
0.30 0%
_ 12 N=>S Exterior
Conc. Elk -Int Ins
KITCHEN 4.1 35.0 0
8.0 1
282.9
0.149 0 0
0.30 0%
_ 13 N=>S Exterior
Conc. Blk- Int Ins
STORAGE 4.1 6.0 0
8.0 0
48.0
0.149 0 0
0.30 0%
_ 14 N=>S Exterior
Conc. Bilk - Int Ins
STORAGE 4.1 5.0 0
8.0 0
40.0
0.149 0 0
0.30 0%
15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0 30.0 0
8.0 0
240.0
0.092 0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width Height
V# Ornt Adjacent To
Door Type
Space Storms
U-Value
Ft
In Ft In
Area
1 E=>W
Insulated
KITCHEN None
0.32
3.00
0 6.00 8
20.0ft2
6/7/202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Page
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
/ Wall
----Overhang-----
�/ # Ornt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation IntedorShade
Screening
-1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.4ft-
1.0 ft 5 in 1.0 ft 5 In None
None
_ 2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft-
1.0 ft 5 In 1.0 It 5 in None
None
_ 3 N=>S 6 Metal
Low-E Single
Yes 1.02
0.29 N N 18.02
1.0 ft 5 in 1.0 ft 5 in None
None
_4 W=>E 7 Metal
Low-E Single
Yes 1.03
0.27 N N 40.Oft2
12.0 Ito in 1.0 It in None
None
-5 S=>N 8 Metal
Low-E Single
Yes 1.02
0.29 N N 6.02
1.0 ft 5 in 1.0 ft 5 in None
None
8 E=>W 10 Metal
Low-E Single
Yes 1.02
0.26 N N 12.8112
1.0 ft5 in 1.0 ft5 in None
None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Space(s)
1 Wholehouse Proposed ACH(50)
0.00026
881 48.35 90.78
0.0907 5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 280 ft2
280 ft2
35 ft
8 it 11
MASS
# Mass Type
Area
Thickness FurnitureFraction Space
_ 1 Default(81bs/sq.ft.)
O ft2
O ft
0.30 MASTER BEDROOM
_ 2 Default(81bs/sq.ft.)
0 112
0 ft
0.30 DEN
_ 3 Default(81bs/sq.ft.)
0 ft2
0 ft
0.30 SINK AREA
_4 Default(8lbs/sq.ft.)
0ft2
Oft
0.30 CLOSET
-5 Dsfault(81bs/sq.ft.)
0 ft2
0 ft
0.30 GREAT ROOM
_ 6 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 MASTER BATH
_7 Defaull(8lbs/sq.ft.)
Oft•
Oft
0.30 POWDER
_8 Default(BIbs/sq.ft)
Oft•
Oft
0.30 KITCHEN
_9 Default(8lbs/sq.ft.)
Oft,
Oft
0.30 LAUNDRY
10 Default(8lbs/sq.ft.)
0 ft2
Oft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity ---Geothertnel HeatPuqDuctBlock
k8tuthr Entry Power Volt
_1 Electric Heat Pump
Split/Single
HSPF: 8.20 27.0 0.00 0.00
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency
Capacity Air Flow
kBtu/hr cfm
_1 Central Unit
Split/Single
SEER:14.0 29.0 0
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
_ 1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard
None
82
Recirculation
Recirc Control
Loop Branch Pump DWHR
Facilities Equal
DWHR
OtherCredits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
JDuct---------Supply-----------------Return---------
# Location R-Value Area Location
Air
CFM 25 CFM 25
HVAC #
R-Value Area Leakage Type
Handler
TOT OUT
ON
RLF Heat Cool
1 Attic
6.0 120 ft'
Attic
6.0 45 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling (]Jan
[]Feb
(]Mar
[]Apr
[]May [XI Jun [)]Jul
[)]Aug
[X]Sep []Oct
[]Nov
[]Dec
Heating [X] Jan
[)] Feb
[)] Mar
[ ] Apr
[ ] May [I Jun [ ] Jul
[ ] Aug
[ ] Sep [] Oct
[X] Nov [)] Dec
Venting []Jan
[]Feb
[XI Mar
[Xj Apr
[]May [j Jun []Jul
[]Aug
[]Sep [Xj Oct
[X]Nov (j Dec
VThermostat Schedule: HERS 2006 Reference
Schedule Type 1
Hours
2
3 4 5 6
7
8 g
10
11 12
_Cooling(WD)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
_Cooling(WEH)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
_Heating (WD)
PM
68
68
68 68 68 68
68
68 68
68
68 68
_Heating(WEH)
AM
68
68
68 68 68 68
68
68 68
68
68 68
PM
68
68
68 68 68 68
68
68 68
68
68 68
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CORP. Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be Installed in the building envelope.
Air-permeableinsulationshall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoinls in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
andcantilevered
shall be permitted to be in contact with the top side
floors)
ofsheathing, orcontinuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor Insulation, Insulation
with a Class l vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by Insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
condilionedspaces.
Recessedlighting
Recessed light fixtures installed in the building thermal
Recessed lig ht fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing andwiring
Batt insulation shall be out neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
onexterlorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
onexteriorwalls
communication boxes or air -sealed boxes shall be installed.
HVAC register bootE
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
6/7/2021 11:47:OOAM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (W)
Conditioned floor area below grade (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor: Sgl, U=1.02
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
THE COTTAGE,FT. PIERCE,FL,
New (From Plans)
10.
Wall Types(1718.3 sqft.)
Insulation
Area
Detached
a. Concrete Black - Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft'
1
c. N/A
R=
ft2
1
d. N/A
R=
ft2
Yes
11.
Ceiling Types(1336.0 sgft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 ft'
1306
b. Knee Wall (Vented)
R=19.0
30.00 ftz
0
c. N/A
R=
fit
Area
12.
Ducts, location & insulation level
R ft2
76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic
6 120
b.
40.00 ft2
C.
13.
Cooling Systems
kBtu/hr
Efficiency
12.85 ft2
a. Central Unit
29.0 SEER:14.00
8. Skylights Description
U-Factor:(AVG) N/A
SHGC(AVG): N/A
9. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R= 0.0
b. N/A R=
c. N/A R=
4.701 ft
0.281
14. Heating Systems
kBtu/hr Efficiency
Area
a. Electric Heat Pump
27.0 HSPF:8.20
N/A ft2
15. Hot Water Systems
Area
2
a. ElectricTankless
Cap' gallons
allons
1306.00 ft
z
EF: 0.600
ftz
b. Conservation features
ft
None
16. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature Date:
Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
® Project SummaryJob:
wrtghtsoft Entire House Br
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, R34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM
Project
For: WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
Notes:
Design Information
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 16327
Btuh
Structure
15522
Btuh
Duds 4013
Btuh
Duds
5251
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipmentload 20340
Btuh
Use manufacturers data
n
Rate/swingg multi
Equipmenisensibleload
0.95
Infiltration
19734
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2094
Btuh
Ducts
1524
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Coolingg
(none)
Area (ft') 1306
IN
Equipment latent load
3618
Btuh
Volume (ft') 10579
10579
Airchangges/hour OA5
EquivAVF 79
0.23
41
Equipment Total Load((Sen+Lat)
Req. total 0.70 SHR
23352
Btuh
(cfm)
capadtyat
2.3
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Cartier
Trade CARRIER
Trade CARRIER
Model CHI4NBO3000GOA0
Cond CH14NBO3000GOA0
AHRI ref 9162387
Coil FX4DNBO43L
AHRI ref 9162387
Efficiency 8.2 HSPF
Efficiency 11.5 EER,14
SEER
Heating input
Sensible cooling
20300
Btuh
Heating output 28000
Btuh @47-F
Latentcooling
8700
Btuh
Temperature rise 26
OF
Total cooling
29000
Btuh
Actual airflow 967
cfm
Actual airflow
967
cf n
Air flow factor 0.048
cfln/Btuh
Airflowfactor
0.047
cfin/Btuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.85
Capacity balance point = 34 OF
Backup:
Input=5kW, Output= 18005 Btuh, 100AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
A -Pk- WPI ht9ofR• 20214arv121321:40
04'w"^^', R914SUteSUmersa1201919.021 RSU08101
...\whgttoft WAQWYNNEBUIDLINGTHECOT-rAGE.rLp Calc=M18 Front Doorfaoss:SW Pagel
�f.:CrA °
wrightsW Right-J@ Worksheet Jab:
Entire House Date:
QUICKCALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone 772.466-6799 EMII:OUICKCALCS@AOL.COM
1
Room name
Entire House
MASTER BEDROOM
2
E1posadwdll
145.0 ft
31.0 ft
3
Room height
8.1 It
8.1 ft heaUmol
4
Rcomdimensons
13.0 x 18.0 it
5
.Room area
1306.0 IF
234.0 ft
Ty
Construction
U-value
Or
HTM
Area 011)
Load
Area(q
Load
number
(BWh41'--°F)
(BWhAF)
or perimeter (ft)
(BWh)
or perimeter (ft)
(BWh)
Heat
Cool
Gross
N/P5
Heat
Cod
Gross
NIPS
Heat
Cool
6
W,
13A-4ocs
0.143
n
4.00
2.19
446
427
1710
934
0 0
0
- 0
I-G
2glazing, droutr,
1.040
n
29.12
21.68
18
0
537
400
0 0
0
0
13A4ocs
0.143
a
4.00
2.19
162
129
516
282
0 0
0
0
2glaang,droutr,
1.040
a
29.12
39A2
13
2
368
498
0
0
0
0
11
D
11 0
0.390
a
10.92
10.34
20
20
223
211
0
0
0
0
13A-4os
0.143
s
4.00
2.19
284
277
1107
605
146
146
684
319
(3
2glaang, droutr,
1.040
s
29.12
21.68
7
7
202
150
0
0
0
0
13A-4=
0.143
w
4.00
2.19
284
192
767
419
105
73
291
159
1Aa1on
1270
w
35.56
34.77
41
41
1451
1419
0
0
0
0
1A-h1om
1270
w
35.56
61.76
18
3
w
1139
0
0
0
0
lhhlom
1270
w
3556
63.40
33
5
1162
2072
33
5
1162
2072
C
16C-30ml
0.032
-
0.90
1.20
1306
1306
1170
1672
234
234
210
300
F
22A-4N
02B9
-
27.69
0.00
1306
145
4015
0
234
31
858
0
6
c)AEDexaason
3591
997
Envelope lossrgaln
13M
13393
3105
3847
12
a) Infiltration
2441
668
522
143
b) Roomventlatron
0
0
0
0
13
Intemalgains: Omlpanls@ 230
2
460
0
0
Appliancesbther
1000
0
Subtotal Qines6to 13)
16327
15522
3627
3990
Less ekernal load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
16327
15522
3627
39N
15
Dud loads
25%
34%
4013
5251
25%
34%
892
1352
Total room load
20340
20773
4518
5342
Alr required(dm)
967
967
215
249
Calculations approved bVACCAt0 meet all requirements of Manual J 8th Ed.
C-�-wrJofvt ft- 2021-Jan-121321:40
Rigft-SUIT Uriversal 201919.021 RSU08101 Page 1
.,.1Wri9%oftWAOWYNNEBUIDLING-THECOTTAGE.np Calc=M78 Front Door faces: SW
wrightsoW Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. eY
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM
1
Room name
DEN
SINKAREA
2
EVosadxall
24.0 ft
7.0 it
3
Room height
8.1 ft heallwol
8.1 ft heaVmol
4
Room dimensions
12.0 x 12.0 fi
6.0 x 7.0 ft
5
Room area
144.0 IF
420 iP
Ty
Construction
U-value
Or
HTM
Area (ff)
Load
Area (
Load
number
(BbJW--'F)
(BWh4P)
or perimeter (it)
(BWh)
or perimeter (a)
(131uh)
Heat
Cool
Gross
N11PS
Heat
Cod
Gross
NIPS
Heat
Cool
6
Vi/
13A-0as
0.143
n
4.00
2.19
97
97
389
213
0
0
0
0
�C
2glaarg,droutr,
1.040
n
29.12
21.68
0
0
0 0
0
0
0
0
13A-0as
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
2glaang,droutr,
1.040
a
29.12
39.42
0
0
0
0
0
0
0
0
11
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
W
13A-4ors
0.143
s
4.00.
2.19
0
0
0
0
57
57
227
124
�-G
2gla2i%droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
- 0
0
13A-4as
0.143
w
4.00
2.19
97
79
315
172
0
0
0
0
1AcIom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
1A-hlom
1270
w
35.56
61.7E
18
3
656
1139
0
0
0
0
1A.hlom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C-30ml
0.032
-
0.90
128
144
144
129
184
42
42
38
54
F
22A-tpl
0.989
-
27.69
0.00
144
24
665
0
42
7
194
0
6
c)AED exarsion
574
S
Envelope lossbain
2154
2283
1
459
175
12
a) Infiltration
404
ill
ila
32
b) Roomvenfilafion
0
0
0
0
13
Intemalgeins: Omlpant3@ 230
0
0
0
0
Applianoaslother
0
0
Subtotal(lines6tol3)
25M
2394
576
207
Lessexkmalload
0
0
0
0
Lesstransfer
0
0
0
0
Redishibuton
0
0
0
0
14
Subtotal
2558
2394
576
207
15
Dudloads
25%
34%
629
811
25%
34A
142
70
Tofalroom load
3187
3205
I
718
278
Airrequired(crlm)
152
149
34
13
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
wr79l�raoTC" 2021-Jan121321:40
AWA """ "'-' RigHSUV�lhiversal 201919.021 RSU08101 Page2
...\WrigttoftWAQWYNNEBUIDLING-THECOTrAGE.np Calc=W8 FrortWorbces:SW
wrightsoft Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 77246"799 Emil: QUICKCALCSa�O DOM
1
Room name
CLOSET
GREAT ROOM
2
Exposedwall
0 It
32.0 t
3
Room height
8.1 ft heaVrool
8.1 ft heaGowl
4
Room dimensions
9.0 x 7.0 It
1.0 x 452.0 It
5
Room area
63.0 P
452.0 iP
Ty
ConsWction
U-value
Or
HTM
Area (P)
Load
Area (fF)
Load
number
(BWh4F°F)
(BWh4F)
or perimeter (fi)
(BWh)
or perimeter (ft)
(BWh)
Heat
Cool
Gross
NIPIS
Heat
Cool
Gros
NVPl9
Heat
Cod
6
Vi/
13AAM
0.143
n
4.00
2.19
0
0
0 0
176
160
640
350
�G
2glaang,droutr,
1.040
n
29.12
21.68
0
0
0 0
18
0
537
400
13AAors
0.143
a
4.00
2.19
0
0
0 0
0 0
0
0
2gglaarg, dr oub,
o
1.040
a
29.12
39.42
0
0 0
0
0 0
0
0
11
D
it
0.390
a
10.92
10.34
0
0
0
0
0 0
0
0
W
134-0as
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
�G
2glaarg,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0.
0
1344ocs
0.143
w
4.00
2.19
0
0
0
0
81
40
161
88
1Aclom
1270
w
35.56
34.77
0
0
0
0
41
41
1451
1419
G
1A-h1om
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
to-hlom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0.90
1.28
63
63
56
81
452
452
405
579
F
22A-tpl
0.989
-
27.69
0.00
63
0
0
0
452
32
886
0
6
c)AEDexorrson
-1
2069
Envelope loWigain
56
801
1
40801
4903
12
a) Infilhafion
0
0
539
148
b) Roomwntlabon
0
0
0
0
13
Intsmalgains: Occupants@ 230
0
0
2
460
Applianoeslolher
1
0
0
Subfotal(lines6b13)
56
80
4619
5511
Less e)demal load
0
0
0
0
Lesstransfer
0
0
0
0
Rodisbibufon
0
0
0
0
14
Subtotal
56
80
4619
5511
15
Dudloads
25%
34%
14
27
25%
34%
1135
1868
Total room lead
70
107
1
5754
7379
Air required(dm)
3
5
274
343
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
-"W WrIuftC ft- 2021-Jan-121321AO
A&k RigttSute®UNverse1201919.021 RSW8101 Page3
...\WrigFEoft HJACrWYNNE BUIDLING-THE COTiAGE.nM1 p Calc=8 Front Door faces: SW
wrightsoft° Right-M Worksheet Job.,
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOLCOM
1
Room name
M1NISTER BATH
POWDER
2
Exiosadwall
5.0 it
0 it
3
Room height
8.1 it heall000l
8.1 It heaVocol
4
Room dimensions
10.0 x 5.0 It
5.0 x 5.0 it
5
Room area
50.0 fF
25.0 1F
Ty
Construction
U-value
Or
HTM
Area
s (fly
Load
number
(IstJft'-T)
(Btuhr)
or perimeter (it)
(eWh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
NJPS
Heat
Cool
Gros
N1P5
Heat
Cool
6
Vj/
13A4o s
0.143
In
4.00
2.19
0
0
0
0
0
0
0
0
t-G
2glaang,droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0
0
0
'
13A-4as
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
G
2glazing, oroutr,
1.040
a
29.12
39A2
0
0
0
0
0
0
0
0
11
�D
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
G
13A4o s
0.143
s
4.00
2.19
41
34
134
73
0
0
0
0
2glaarlg,droutr,
1,040
s
29.12
21.68
7
1
202
150
0
1
0
0
13A4ocs
0.w
w
4.00
2.19
0
0
0
0
0
0
0
0
1Aclon
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
1A-h1om
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
16C-qoml
0,032
-
0.90
128
50
50
45
64
25
25
22
32
F
22A-¢I
0.989
-
27.69
0.00
50
5
138
0
25
0
0
0
6
c) AED ewslm
4
0
Envelopelowigain
52C
284
22
32
12
a) Infiltration
84
23
0
0
b) Ro invantlation
0
0
0
0
13
Internal gains: Ocoupants@ 230
0
0
0
0
Applianoestolher
0
0
Subtolai (lnas6to13)
6041
307
22
32
Lesextemalload
0
0
0
0
Les tranSer
0
0
0
0
Redistributon
0
0
0
0
14
Subtotal
604
307
22
32
15
Dudloads
25%
34%
148
104
25%
34A
6
11
Total room bad
752
411
28
42
Air required(rim)
36
19
1
2
Calculations approved bvACCAto meet all requirements of Manual J th Ed
TLF wrl9bbof!- 2021-Jan
AWA RigH-HEC UTAGE1 p Calc.0218 Frort o Page4
...1Wrigt6rofl NVACIWYNNE BUIDLING-THE COTTAGE Catc=MI8 Frort Door ta�s:SW
wrightsoft` Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST LUCIE LANE, FORT PIERCE, FL34946 Pierre: 772A66-6799 Email: QUICKCALCS@(iAOL.COM
1
Room name
KITCHEN
LAUNDRY
5posedwall
38A ft
O R
3
Ro
Room height
8.1 R heaVrool
8.1 It heat/cool
4
Room dimensons
1.0 x 232.0 ft
4.0 x 10.0 ft
5
Room area
232.0 R°
40.0 fF
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (R')
Load
number
(BWhtP-'F)
(BWhM)
or perimeter (ft)
(BWh)
or Perimeter (R)
(BWh)
Heat
TCool
Gross
NIPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
N/
13A-4=
0.143
n
4.00
2.19
138
138
551
301
0 0
0
0
�G
2glazig, dr out-,
1.040
In
29.12
21.68
0 0
0 0
0 0-
0
0
13A4ocs
0.143
a
4.00
2.19
130
97
387
211
0 0
0
0
V6
2glaang,droutr,
1.040
a
29.12
39.42
13
2
368
498
0 0
0
0
11
11D0
0.390
a
10.92
10.34
20
20
223
211
0
0
0
0
lM
lak4os
0.143
s
4.00
2.19
41
41
162
89
0
0
0
0
t-G
2glabng,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0
_
0
13A4ars
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1Aaiorn
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
G
1A-hlom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0.90
128
232
232
208
297
40
40
36
51
F
22A-tPI
0.989
-
27.69
0.00
232
38
1052
0
40
0
0
0
6
c)AED e=rslon
37
-1
Envelope losstgain
2951
1570
36
51
12
a) Infiltration
640
176
0
0
b) Roomventlaton
0
0
0
0
13
Intemal gains: Oovpants@ 230
0
0
0
0
Applianoes(other
1000
0
Subtotal(liw6 to 13)
35911
2745
136
61
Less external bad
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3591
2745
36
51
15
Duct loads
25%
34%
883
931
25%
34%
9
17
Total room bad
4474
3676
45
68
Air required(dm)
213
171
2
3
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
,e -�{►- wr19tiffioT[^ 2021-Jan�121321;40
cp RigIt-Sute®UdvemI201919.021 RSU08101 Pages
...1Wrigtboft FNAC\WYNNEBUIDLING-THECOTrAGE.nq CaIc=M18 FmrtDoorfams:SW
wrightsoft` Right-J@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. Ii
317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 77246"799 Email: OUICKCALCSaUi OL.00M
1
Room name
STORAGE
2
Bposedmll
8.0 It
3
Room height
8.1 it heatlmol
4
Room dimensions
4.0 x 6.0 ft
5
Room area
24,0 fe
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area
Load
number
(BWhW-9
(BNh/P)
or perimeter (ft)
(BWh)
or perimeter
Heat
Cool
Gross
NrPrS
Heat
Cool
Gras
NIPS
Heat
Cool
6
W "
13AAow
0.143
n
4.00
2.19
32
32
130
71
L—G
2glazig, droutr,
1.040
n
29.12
21.68
0
0
0
0
13AAm
0.143
a
4.00
2.19
32
32
130
71
2glazing, oroutr,
1.040
a
29.12
39.42
0
0
0
0
11
D
1100
0.390
a
10.92
10.34
0
0
0
0
W
13A-4=
0.143
s
4.00
2.19
0
0
0
0
T—G
2glabng,d1outr,
1,040
s
29,12
21.68
0
0
0
0
1AAclw
w
4.56
2.77
0
0
0
0
1A-h1om
1270
1270
w
35.56
0
0
0
0
1A-hlom
1270
w
35.56
61.76
61.76
0
0
0
0
1A-h1om
1270
w
35.56
63.40
0
0
0
0
C
16C-3Onl
0.032
-
0.90
128
24
24
22
31
-
F
22A-tpl
0.989
-
27.69
0.00
24
8
222
0
6
c)AED e=rdon
.3
ErnelopeloWgain
502
170
12
a) Infiltration
135
37
b) Roomlentlaton
0
0
13
Intemalgairs: Omrpants@ 230
0
0
Applianceslother
p
Sub1o6l(lines6m13)
637
207
Less external load
0
0
Lesstransfer
0
0
Redisbibullon
0
0
14
Subtetal
637
217
15
Dudloads
25%
299%
157
60
Total room load
794
266
Airrequired(dm)
38
12
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
G - wr19ti'moTe- 2021-JanF121321:40
ACrk RigHSule5l Unwrsa1201919.021 RSU08101 Page6
...\Wrightoft H/AC\WYNNEBUIDLING-THECOTTAGE.np Calc=W8 Fort Door faces: SW
wrightsoftf Duct System Summary Job:Y rY Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34M Phone: 772466-6799 Email: QUICKCALCS@AOL.COM
Project Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
External static pressure
Pressure losses
Available staflc pressure
Supply/ return available pressure
Lowest fiction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/1001
967
cfin
126
Supply Branch Detail Table
Cooling
0.50
in H2O
0,28
in H2O
0.22
in H2O
0,110/0.110
in H2O
0.080
in/100ft
967
cfrn
Name
Design
(Btuh)
Htg
(cfm)
Clg
(ft
Design
FR
Diam
(in)
HxW
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
c 107
3
5
0.080
4.0
OxO
MFx
24.6
90.0
st1
DEN
h 3187
152
149
0.080
7.0
OxO
MFx
33.5
90.0
st1
GREATROOM
c 3689
137
172
0.080
8.0
OxO
MFx
14.6
70.0
GREAT ROOM -A
c 3689
137
172
0.080
8.0
OxO
MFx
16.1
70.0
KITCHEN
h 4474
213
171
0.080
7.0
Ox0
MFx
4.5
70.0
LAUNDRY
C 68
2
3
0.080
4.0
Ox0
MFx
5.4
70.0
MASTERBATH
h 752
36
19
0.080
4.0
OxO
MFx
32.9
90.0
st1
MASTERBEOROOM
C 2671
107
124
0.080
7.0
OXO
VIFX
27.9
90.0
st1
MASTERSEDROONM
c 2671
107
124
0.080
7.0
Ox0
MFx
35.9
90.0
st1
POWDER
c 42
1
2
0.080
4.0
OxO
MFx
29.2
90.0
st1
SINKAREA
h 718
34
13
0.080
4.0
Ox0
MFx
30.9
90.0
st1
STORAGE
h 794
38
12
0.080
4.0
Ox0
MFx 1
11.2
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(Cfm)
Clg
(ctm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
441
437
0.080
561
12.0
0 x 0
VnIFIX
t # wrightsoft- 20214arv121321:41
RigH-SUte®Unverml201919.021 R8U08101 Page 1
A ...\Wrigtt ftWADWYNNEBUIDLING-T ECOTrAGE.rtp Calc=MJ9 Fror Doorfaas:$W
IReturn Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Ueloc
(fpm)
Diam
I (in)
HxW
(in)
Stud/Joist
Opening (in)
Duct
Mad
Trunk
rb1
OxO
967
967
0
1 0
0
0
Ox 0
VIFx
-Pk- wrightsoft- 2021-Jan121321:41
9glbSUtc4JUnversal 201919.021 RSU08101 Page
...\Wrigtcufl WAQWYNNEBUIDLING-THECOTTAGE.np Calc=M18 FrortWorfaces:SW