Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 13945 CEDROFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. LUcle(Florlda Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240,00 ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11, Ceiling Types(1336.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade (ft2) 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(128.9 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1,02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b, U-Factor: Sgl, U=1,03 40.00 ft2 c, SHGC: SHGC=0.27 13. Cooling Systems kBtulhr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 15. Hot Water Systems 9. Floor Types Insulation Area 2 a. ElectricTankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 EF: 0.600 b. NIA R= ft b. Conservation features c. NIA R= ft2 None 16. Credits None GiasslFloor Area: 0.099 Total Proposed Modified Loads: 41.30 PASS Total Baseline Loads: 43.21 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this gifts Code. calculation indicates compliance with the Florida Energy Code. PREPARED 8Y: Before construction is completed this building will be inspected for DATE: 6-7-2021 compliance with Section 553.908 Florida Statutes. ' we I hereby certify that this building, as designed, i compliance1^,O with the Florida Energy C te��w -c OWNE EST: BUILDING OFFICIAL: DATE:- � DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 111403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET)ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Addresstype: Street Address Building Type: User Bedrooms: 1 Lot#: --- Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: --- Total Stories: 1 PlatBook: --- Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: CrossVentilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE VDesign Design Temp Int Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO-SEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13K076.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes 8 MASTER BATH 50 406 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # FloorType Space Exposed Perim Perimeter R-Value Area U-Factor JoistR-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 It 0.473 --- 0.00 1.00 0.00 -2 Slab -On -Grade Edge Ins DEN 24 0 144 ft 0,473 -- 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins SINK AREA 7 0 42 ft 0.473 --- 0.00 1.00 0.00 _ 4 Slab -On -Grade Edge Ins CLOSET 1 0 63 ft 0.473 --- 0.00 1.00 0.00 _ 5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452 ft 0.473 --- 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 -- 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER 1 0 25ft 0.473 -- 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins KITCHEN 38 0 232 ft 0.473 --- 0.00 1.00 0.00 _9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40it 0.473 -- 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24 it 0.304 - 0.00 0.00 1.00 6/7/2021 11:47:00 AM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) _ 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fullattic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type -1 UnderAttic(Vented) MASTER BEDROOM 30.0 Blown 234.0ft2 0.053 0.10 Wood _2 UnderAftic(Vented) DEN 30.0 Blown 144.oft2 0.053 0.10 Wood _3 UnderAftle(Venfed) SINK AREA 30.0 Blown 42.0ft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.0ft2 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.Oft2 0.053 0.10 Wood 8 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.0ft2 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.0112 0.053 0.10 Wood B UnderAftio(Vented) KITCHEN 30.0 Blown 232.0112 0.053 0.10 Wood _9 UnderAftic(Venfed) LAUNDRY 30.0 Blown 40.0ft2 0.053 0.10 Wood _ 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.Oft2 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation Is modified by the rotate angle (180 degrees) as shown in the "Project' section on page 1. Cavity Width Height Area U- Sheath Frm. Solar Below JAdjacent # Ornl To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Free. Absor. Grade _ 1 S=>N Exterior Cone. Bik- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Cone. Elk - Intins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Cone. Bik -Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Bik- Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _ 5 S=>N Exterior Cone. Elk- Int Ins SINK AREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _ 6 N=>S Exterior Cone. Elk- Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _ 7 W=>E Exterior Cone. Elk- Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _ 8 S=>N Exterior Cone. Bilk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc.Blk- IntIns KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. Bilk - Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. BIk- Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. Elk -Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. Blk- Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Bilk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height V# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.0ft2 6/7/202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Page FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall ----Overhang----- �/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation IntedorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.4ft- 1.0 ft 5 in 1.0 ft 5 In None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft- 1.0 ft 5 In 1.0 It 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.02 1.0 ft 5 in 1.0 ft 5 in None None _4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.Oft2 12.0 Ito in 1.0 It in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.02 1.0 ft 5 in 1.0 ft 5 in None None 8 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8112 1.0 ft5 in 1.0 ft5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8 it 11 MASS # Mass Type Area Thickness FurnitureFraction Space _ 1 Default(81bs/sq.ft.) O ft2 O ft 0.30 MASTER BEDROOM _ 2 Default(81bs/sq.ft.) 0 112 0 ft 0.30 DEN _ 3 Default(81bs/sq.ft.) 0 ft2 0 ft 0.30 SINK AREA _4 Default(8lbs/sq.ft.) 0ft2 Oft 0.30 CLOSET -5 Dsfault(81bs/sq.ft.) 0 ft2 0 ft 0.30 GREAT ROOM _ 6 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 MASTER BATH _7 Defaull(8lbs/sq.ft.) Oft• Oft 0.30 POWDER _8 Default(BIbs/sq.ft) Oft• Oft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) Oft, Oft 0.30 LAUNDRY 10 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity ---Geothertnel HeatPuqDuctBlock k8tuthr Entry Power Volt _1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow kBtu/hr cfm _1 Central Unit Split/Single SEER:14.0 29.0 0 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length _ 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS JDuct---------Supply-----------------Return--------- # Location R-Value Area Location Air CFM 25 CFM 25 HVAC # R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling (]Jan []Feb (]Mar []Apr []May [XI Jun [)]Jul [)]Aug [X]Sep []Oct []Nov []Dec Heating [X] Jan [)] Feb [)] Mar [ ] Apr [ ] May [I Jun [ ] Jul [ ] Aug [ ] Sep [] Oct [X] Nov [)] Dec Venting []Jan []Feb [XI Mar [Xj Apr []May [j Jun []Jul []Aug []Sep [Xj Oct [X]Nov (j Dec VThermostat Schedule: HERS 2006 Reference Schedule Type 1 Hours 2 3 4 5 6 7 8 g 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoinls in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation andcantilevered shall be permitted to be in contact with the top side floors) ofsheathing, orcontinuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor Insulation, Insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and condilionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed lig ht fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing andwiring Batt insulation shall be out neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexterlorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes or air -sealed boxes shall be installed. HVAC register bootE HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 6/7/2021 11:47:OOAM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (W) Conditioned floor area below grade (ft2) 7. Windows** Description a. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 SHGC: SHGC=0.27 c. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: THE COTTAGE,FT. PIERCE,FL, New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area Detached a. Concrete Black - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft' 1 c. N/A R= ft2 1 d. N/A R= ft2 Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft' 1306 b. Knee Wall (Vented) R=19.0 30.00 ftz 0 c. N/A R= fit Area 12. Ducts, location & insulation level R ft2 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. 40.00 ft2 C. 13. Cooling Systems kBtu/hr Efficiency 12.85 ft2 a. Central Unit 29.0 SEER:14.00 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= 4.701 ft 0.281 14. Heating Systems kBtu/hr Efficiency Area a. Electric Heat Pump 27.0 HSPF:8.20 N/A ft2 15. Hot Water Systems Area 2 a. ElectricTankless Cap' gallons allons 1306.00 ft z EF: 0.600 ftz b. Conservation features ft None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature Date: Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project SummaryJob: wrtghtsoft Entire House Br QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, R34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM Project For: WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Btuh Duds 5251 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 20340 Btuh Use manufacturers data n Rate/swingg multi Equipmenisensibleload 0.95 Infiltration 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft') 1306 IN Equipment latent load 3618 Btuh Volume (ft') 10579 10579 Airchangges/hour OA5 EquivAVF 79 0.23 41 Equipment Total Load((Sen+Lat) Req. total 0.70 SHR 23352 Btuh (cfm) capadtyat 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Cartier Trade CARRIER Trade CARRIER Model CHI4NBO3000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating input Sensible cooling 20300 Btuh Heating output 28000 Btuh @47-F Latentcooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual airflow 967 cfm Actual airflow 967 cf n Air flow factor 0.048 cfln/Btuh Airflowfactor 0.047 cfin/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=5kW, Output= 18005 Btuh, 100AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed A -Pk- WPI ht9ofR• 20214arv121321:40 04'w"^^', R914SUteSUmersa1201919.021 RSU08101 ...\whgttoft WAQWYNNEBUIDLINGTHECOT-rAGE.rLp Calc=M18 Front Doorfaoss:SW Pagel �f.:CrA ° wrightsW Right-J@ Worksheet Jab: Entire House Date: QUICKCALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone 772.466-6799 EMII:OUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E1posadwdll 145.0 ft 31.0 ft 3 Room height 8.1 It 8.1 ft heaUmol 4 Rcomdimensons 13.0 x 18.0 it 5 .Room area 1306.0 IF 234.0 ft Ty Construction U-value Or HTM Area 011) Load Area(q Load number (BWh41'--°F) (BWhAF) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross N/P5 Heat Cod Gross NIPS Heat Cool 6 W, 13A-4ocs 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 - 0 I-G 2glazing, droutr, 1.040 n 29.12 21.68 18 0 537 400 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 162 129 516 282 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39A2 13 2 368 498 0 0 0 0 11 D 11 0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 13A-4os 0.143 s 4.00 2.19 284 277 1107 605 146 146 684 319 (3 2glaang, droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 13A-4= 0.143 w 4.00 2.19 284 192 767 419 105 73 291 159 1Aa1on 1270 w 35.56 34.77 41 41 1451 1419 0 0 0 0 1A-h1om 1270 w 35.56 61.76 18 3 w 1139 0 0 0 0 lhhlom 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-30ml 0.032 - 0.90 1.20 1306 1306 1170 1672 234 234 210 300 F 22A-4N 02B9 - 27.69 0.00 1306 145 4015 0 234 31 858 0 6 c)AEDexaason 3591 997 Envelope lossrgaln 13M 13393 3105 3847 12 a) Infiltration 2441 668 522 143 b) Roomventlatron 0 0 0 0 13 Intemalgains: Omlpanls@ 230 2 460 0 0 Appliancesbther 1000 0 Subtotal Qines6to 13) 16327 15522 3627 3990 Less ekernal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16327 15522 3627 39N 15 Dud loads 25% 34% 4013 5251 25% 34% 892 1352 Total room load 20340 20773 4518 5342 Alr required(dm) 967 967 215 249 Calculations approved bVACCAt0 meet all requirements of Manual J 8th Ed. C-�-wrJofvt ft- 2021-Jan-121321:40 Rigft-SUIT Uriversal 201919.021 RSU08101 Page 1 .,.1Wri9%oftWAOWYNNEBUIDLING-THECOTTAGE.np Calc=M78 Front Door faces: SW wrightsoW Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. eY 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOL.COM 1 Room name DEN SINKAREA 2 EVosadxall 24.0 ft 7.0 it 3 Room height 8.1 ft heallwol 8.1 ft heaVmol 4 Room dimensions 12.0 x 12.0 fi 6.0 x 7.0 ft 5 Room area 144.0 IF 420 iP Ty Construction U-value Or HTM Area (ff) Load Area ( Load number (BbJW--'F) (BWh4P) or perimeter (it) (BWh) or perimeter (a) (131uh) Heat Cool Gross N11PS Heat Cod Gross NIPS Heat Cool 6 Vi/ 13A-0as 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 �C 2glaarg,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-0as 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13A-4ors 0.143 s 4.00. 2.19 0 0 0 0 57 57 227 124 �-G 2gla2i%droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 - 0 0 13A-4as 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 1AcIom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35.56 61.7E 18 3 656 1139 0 0 0 0 1A.hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30ml 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22A-tpl 0.989 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED exarsion 574 S Envelope lossbain 2154 2283 1 459 175 12 a) Infiltration 404 ill ila 32 b) Roomvenfilafion 0 0 0 0 13 Intemalgeins: Omlpant3@ 230 0 0 0 0 Applianoaslother 0 0 Subtotal(lines6tol3) 25M 2394 576 207 Lessexkmalload 0 0 0 0 Lesstransfer 0 0 0 0 Redishibuton 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Dudloads 25% 34% 629 811 25% 34A 142 70 Tofalroom load 3187 3205 I 718 278 Airrequired(crlm) 152 149 34 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wr79l�raoTC" 2021-Jan121321:40 AWA """ "'-' RigHSUV�lhiversal 201919.021 RSU08101 Page2 ...\WrigttoftWAQWYNNEBUIDLING-THECOTrAGE.np Calc=W8 FrortWorbces:SW wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 77246"799 Emil: QUICKCALCSa�O DOM 1 Room name CLOSET GREAT ROOM 2 Exposedwall 0 It 32.0 t 3 Room height 8.1 ft heaVrool 8.1 ft heaGowl 4 Room dimensions 9.0 x 7.0 It 1.0 x 452.0 It 5 Room area 63.0 P 452.0 iP Ty ConsWction U-value Or HTM Area (P) Load Area (fF) Load number (BWh4F°F) (BWh4F) or perimeter (fi) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPIS Heat Cool Gros NVPl9 Heat Cod 6 Vi/ 13AAM 0.143 n 4.00 2.19 0 0 0 0 176 160 640 350 �G 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 13AAors 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2gglaarg, dr oub, o 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 D it 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 134-0as 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 �G 2glaarg,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0. 0 1344ocs 0.143 w 4.00 2.19 0 0 0 0 81 40 161 88 1Aclom 1270 w 35.56 34.77 0 0 0 0 41 41 1451 1419 G 1A-h1om 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 to-hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 1.28 63 63 56 81 452 452 405 579 F 22A-tpl 0.989 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AEDexorrson -1 2069 Envelope loWigain 56 801 1 40801 4903 12 a) Infilhafion 0 0 539 148 b) Roomwntlabon 0 0 0 0 13 Intsmalgains: Occupants@ 230 0 0 2 460 Applianoeslolher 1 0 0 Subfotal(lines6b13) 56 80 4619 5511 Less e)demal load 0 0 0 0 Lesstransfer 0 0 0 0 Rodisbibufon 0 0 0 0 14 Subtotal 56 80 4619 5511 15 Dudloads 25% 34% 14 27 25% 34% 1135 1868 Total room lead 70 107 1 5754 7379 Air required(dm) 3 5 274 343 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -"W WrIuftC ft- 2021-Jan-121321AO A&k RigttSute®UNverse1201919.021 RSW8101 Page3 ...\WrigFEoft HJACrWYNNE BUIDLING-THE COTiAGE.nM1 p Calc=8 Front Door faces: SW wrightsoft° Right-M Worksheet Job., Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: OUICKCALCS@AOLCOM 1 Room name M1NISTER BATH POWDER 2 Exiosadwall 5.0 it 0 it 3 Room height 8.1 it heall000l 8.1 It heaVocol 4 Room dimensions 10.0 x 5.0 It 5.0 x 5.0 it 5 Room area 50.0 fF 25.0 1F Ty Construction U-value Or HTM Area s (fly Load number (IstJft'-T) (Btuhr) or perimeter (it) (eWh) or perimeter (it) (Btuh) Heat Cool Gross NJPS Heat Cool Gros N1P5 Heat Cool 6 Vj/ 13A4o s 0.143 In 4.00 2.19 0 0 0 0 0 0 0 0 t-G 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 ' 13A-4as 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 G 2glazing, oroutr, 1.040 a 29.12 39A2 0 0 0 0 0 0 0 0 11 �D 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 G 13A4o s 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 2glaarlg,droutr, 1,040 s 29.12 21.68 7 1 202 150 0 1 0 0 13A4ocs 0.w w 4.00 2.19 0 0 0 0 0 0 0 0 1Aclon 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C-qoml 0,032 - 0.90 128 50 50 45 64 25 25 22 32 F 22A-¢I 0.989 - 27.69 0.00 50 5 138 0 25 0 0 0 6 c) AED ewslm 4 0 Envelopelowigain 52C 284 22 32 12 a) Infiltration 84 23 0 0 b) Ro invantlation 0 0 0 0 13 Internal gains: Ocoupants@ 230 0 0 0 0 Applianoestolher 0 0 Subtolai (lnas6to13) 6041 307 22 32 Lesextemalload 0 0 0 0 Les tranSer 0 0 0 0 Redistributon 0 0 0 0 14 Subtotal 604 307 22 32 15 Dudloads 25% 34% 148 104 25% 34A 6 11 Total room bad 752 411 28 42 Air required(rim) 36 19 1 2 Calculations approved bvACCAto meet all requirements of Manual J th Ed TLF wrl9bbof!- 2021-Jan AWA RigH-HEC UTAGE1 p Calc.0218 Frort o Page4 ...1Wrigt6rofl NVACIWYNNE BUIDLING-THE COTTAGE Catc=MI8 Frort Door ta�s:SW wrightsoft` Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Pierre: 772A66-6799 Email: QUICKCALCS@(iAOL.COM 1 Room name KITCHEN LAUNDRY 5posedwall 38A ft O R 3 Ro Room height 8.1 R heaVrool 8.1 It heat/cool 4 Room dimensons 1.0 x 232.0 ft 4.0 x 10.0 ft 5 Room area 232.0 R° 40.0 fF Ty Construction U-value Or HTM Area (ft') Load Area (R') Load number (BWhtP-'F) (BWhM) or perimeter (ft) (BWh) or Perimeter (R) (BWh) Heat TCool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 N/ 13A-4= 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 �G 2glazig, dr out-, 1.040 In 29.12 21.68 0 0 0 0 0 0- 0 0 13A4ocs 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 V6 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 lM lak4os 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 t-G 2glabng,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 _ 0 13A4ars 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aaiorn 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 G 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 232 232 208 297 40 40 36 51 F 22A-tPI 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)AED e=rslon 37 -1 Envelope losstgain 2951 1570 36 51 12 a) Infiltration 640 176 0 0 b) Roomventlaton 0 0 0 0 13 Intemal gains: Oovpants@ 230 0 0 0 0 Applianoes(other 1000 0 Subtotal(liw6 to 13) 35911 2745 136 61 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Duct loads 25% 34% 883 931 25% 34% 9 17 Total room bad 4474 3676 45 68 Air required(dm) 213 171 2 3 Calculations approved byACCAto meet all requirements of Manual J 8th Ed ,e -�{►- wr19tiffioT[^ 2021-Jan�121321;40 cp RigIt-Sute®UdvemI201919.021 RSU08101 Pages ...1Wrigtboft FNAC\WYNNEBUIDLING-THECOTrAGE.nq CaIc=M18 FmrtDoorfams:SW wrightsoft` Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. Ii 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 77246"799 Email: OUICKCALCSaUi OL.00M 1 Room name STORAGE 2 Bposedmll 8.0 It 3 Room height 8.1 it heatlmol 4 Room dimensions 4.0 x 6.0 ft 5 Room area 24,0 fe Ty Construction U-value Or HTM Area (ft') Load Area Load number (BWhW-9 (BNh/P) or perimeter (ft) (BWh) or perimeter Heat Cool Gross NrPrS Heat Cool Gras NIPS Heat Cool 6 W " 13AAow 0.143 n 4.00 2.19 32 32 130 71 L—G 2glazig, droutr, 1.040 n 29.12 21.68 0 0 0 0 13AAm 0.143 a 4.00 2.19 32 32 130 71 2glazing, oroutr, 1.040 a 29.12 39.42 0 0 0 0 11 D 1100 0.390 a 10.92 10.34 0 0 0 0 W 13A-4= 0.143 s 4.00 2.19 0 0 0 0 T—G 2glabng,d1outr, 1,040 s 29,12 21.68 0 0 0 0 1AAclw w 4.56 2.77 0 0 0 0 1A-h1om 1270 1270 w 35.56 0 0 0 0 1A-hlom 1270 w 35.56 61.76 61.76 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 C 16C-3Onl 0.032 - 0.90 128 24 24 22 31 - F 22A-tpl 0.989 - 27.69 0.00 24 8 222 0 6 c)AED e=rdon .3 ErnelopeloWgain 502 170 12 a) Infiltration 135 37 b) Roomlentlaton 0 0 13 Intemalgairs: Omrpants@ 230 0 0 Applianceslother p Sub1o6l(lines6m13) 637 207 Less external load 0 0 Lesstransfer 0 0 Redisbibullon 0 0 14 Subtetal 637 217 15 Dudloads 25% 299% 157 60 Total room load 794 266 Airrequired(dm) 38 12 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed G - wr19ti'moTe- 2021-JanF121321:40 ACrk RigHSule5l Unwrsa1201919.021 RSU08101 Page6 ...\Wrightoft H/AC\WYNNEBUIDLING-THECOTTAGE.np Calc=W8 Fort Door faces: SW wrightsoftf Duct System Summary Job:Y rY Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34M Phone: 772466-6799 Email: QUICKCALCS@AOL.COM Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available staflc pressure Supply/ return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/1001 967 cfin 126 Supply Branch Detail Table Cooling 0.50 in H2O 0,28 in H2O 0.22 in H2O 0,110/0.110 in H2O 0.080 in/100ft 967 cfrn Name Design (Btuh) Htg (cfm) Clg (ft Design FR Diam (in) HxW (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO MFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO MFx 33.5 90.0 st1 GREATROOM c 3689 137 172 0.080 8.0 OxO MFx 14.6 70.0 GREAT ROOM -A c 3689 137 172 0.080 8.0 OxO MFx 16.1 70.0 KITCHEN h 4474 213 171 0.080 7.0 Ox0 MFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox0 MFx 5.4 70.0 MASTERBATH h 752 36 19 0.080 4.0 OxO MFx 32.9 90.0 st1 MASTERBEOROOM C 2671 107 124 0.080 7.0 OXO VIFX 27.9 90.0 st1 MASTERSEDROONM c 2671 107 124 0.080 7.0 Ox0 MFx 35.9 90.0 st1 POWDER c 42 1 2 0.080 4.0 OxO MFx 29.2 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 Ox0 MFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 Ox0 MFx 1 11.2 70.0 Supply Trunk Detail Table Name Trunk Type Htg (Cfm) Clg (ctm) Design FIR Veloc (fpm) Diam (in) H x W (in) Dud Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VnIFIX t # wrightsoft- 20214arv121321:41 RigH-SUte®Unverml201919.021 R8U08101 Page 1 A ...\Wrigtt ftWADWYNNEBUIDLING-T ECOTrAGE.rtp Calc=MJ9 Fror Doorfaas:$W IReturn Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Ueloc (fpm) Diam I (in) HxW (in) Stud/Joist Opening (in) Duct Mad Trunk rb1 OxO 967 967 0 1 0 0 0 Ox 0 VIFx -Pk- wrightsoft- 2021-Jan121321:41 9glbSUtc4JUnversal 201919.021 RSU08101 Page ...\Wrigtcufl WAQWYNNEBUIDLING-THECOTTAGE.np Calc=M18 FrortWorfaces:SW