HomeMy WebLinkAboutAPPROVED M ENERGY CALCS & MANUAL J - 24 SAN ROBERTOFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GEMINI IMPACT Street: City, State,Zp: FT. PIERCE, FL, Owner: DesignLocation: FL, Fort Pierce BuilderName: WYNNE BUILDING CORP. PermitOffioe: ST. LUCIE COUNTY PermitNumber: Jurisdiction: County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Types(1763.8 sqft,) Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Ent Insul, Exterior R=4A 1507.80 ft 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent R=11.0 256.00 ft2 c NIA R= fF 4. Number of Bedrooms 2 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1839.0 sqft.) Insulation Area a. UnderAttic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area above grade (ft2) 1839 b. NIA R= ft2 Conditioned floorarea belowgrade (ft2) 0 c. NIA R= ft2 7. Windows(155.3 sqft.) Description Area 12. Ducts R ft' a. U-Factor: Sgl, U=1.02 115.28 fE= a. Sup: Attic, Pet: Attic, AH: Attic 6 125 SHGC: SHGC=0.27 b. U-Factor. SgI, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC-- Area Weighted Average Overhang Depth: 3,318 ft. 14. Heating systems k13hJhr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA 9. F]oorTypes (1839.0 sqft.) insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation features EF:0.950 b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.084 Total Proposed Modified Loads: 51.52 PASS Total Baseline Loads: 52.9Fi I hereby certify that the plans and specifications covered by Review of the plans and -tl0 s this calculation are in compliance with the Florida Energy specifications covered by this a0 Code calculation indicates compliance '; with the Florida Energy Code. +� irr� ,. y. ;.:- •+ U. PREPARED BY: Before construction is completed W r� � DATE: 1-'1 -2 1 this building will be inspected for � �} compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Energy Florida Statutes. with the Code.WS �'��, OWNER/ N BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/13/2021 7:44 AM 7.0,00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GEMINI IMPACT Bedrooms: 2 Address Type: Street Address Building Type: User ConditionedArea: 1839 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBock: BuilderName: WYNNE BUILDING CORP. RotateAngle: 270 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / V Design Location Design Temp TMY Site 97.5% 2.5% Int Design Temp Winter Summer Heating Design Degree Days Moisture DailyTemp Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY 83 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes 9 CLOSET 56 448 No 0 1 No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING ROOM 110 880 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Insulation BEDROOM 43 ft 0 343 ft2 ---- 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63 ft2 --_- 0 1 0 3 Slab -On -Grade Edge Insulation M.BATH 8ft 0 56 ft- ---- 0 1 0 4 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 172 ft2 __-- 0 1 0 5 Slab -On -Grade Edge Insulation MASTERBEDRO 51ft 0 256 ft' ---_ 0 1 0 1/13/2021 7:44 AM 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JolstR-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation ENTRY 7ft 0 83 ft2 -___ 0 1 0 7 Slab -On -Grade Edge Insulation LAUNDRY 6ft 0 42 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulation GREAT/DINING 39ft 0 568 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulation CLOSET2 1ft 0 56 ft2 ___- 0 1 0 10SIab-On-Grade Edge Insulation BATH aft 0 48W -___ 0 1 0 11SIab-On-Grade Edge Insulation POWDER 1 ft 0 42W _--- 0 1 0 12SIab-On-Grade Edge Insulation SITTING ROOM 22ft 0 110 ft2 _--- 0 1 0 ROOF J Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft2 Oft= Light N 0.6 No 0.7 No 0 18.43 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fullattic Vented 150 1839ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) BEDROOM 30 Blown 343 f12 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 ft' 0.1 Wood 4 UnderAftic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 UnderAttic(Vented) MASTER BEDRO 30 Blown 256 fP 0.1 Wood 6 UnderAttic(Vented) ENTRY 30 Blown 83 ft2 0.1 Wood 7 UnderAttic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 8 Under Attic (Vented) GREAT/DINING 30 Blown 568 ft' 0.1 Wood 9 UnderAttic(Vented) CLOSET2 30 Blown 56 ft2 0.1 Wood 10 UnderAtfic(Vented) BATH 30 Blown 48ft2 0.1 Wood 11 UnderAttic(Vented) POWDER 30 Blown 42 ft2 0.1 Wood 12 UnderAttic(Vented) SITTING ROOM 30 Blown 110ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>E Exterior Concrete Block- Int lnsul BEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.4 0 _2 W=>S Exterior Concrete Block- Int lnsul BEDROOM 4.1 14 0 8 0 112.Oft2 0 0 0.4 0 _3 S=>E Exterior Concrete Block-Int lnsul M.BATH 4.1 8 0 8 0 64.0W 0 0 0.4 0 4 N=>W Exterior Concrete Block- Int lnsuMASTER BE 4.1 24 0 8 0 192.0 ft2 0 0 0.4 0 1/13/2021 7:44 AM 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY rH;:rKI IRT PFPnPT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _5 E=>N Exterior Concrete Block- Int lnsuMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 6 S=>E Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0 fF 0 0 0.4 0 _7 E=>N Exterior Concrete Block -Int lnsul ENTRY 4.1 6 0 8 0 48.0 fF 0 0 0.4 0 _8 $=>E Exterior Concrete Block-Intlnsul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 9 S=>E Exterior Concrete Block -Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 10 N=>W Exterior Concrete Block- Int lnsulGREAT/DINI 4.1 30 0 8 11 267.5 If 0 0 0.4 0 11 W=>S Exterior Concrete Block -Int lnsUGRE4T/DIN1 4.1 9 0 8 11 80.3 ft2 0 0 0.4 0 _12 N=>W Exterior Concrete Block-Intlnsul BATH2 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 13 N=>W Exterior Concrete Block- Int InsuSITTING RO 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _14 S=>E Exterior Concrete Block- Int InsuSITTING RO 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 15 W=>S Exterior Concrete Block- Ind InsuSITTING RO 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _16 N=>W Garage Frame -Wood KITCHEN 11 32 8 256.0IF 0.23 GA 0 DOORS # Omt DoorType Space Stones U-Value Width Height Area Ft In R In 1 E=>N Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation shown isthe entered orientation => changed to Worst Case. _ / Wall Overhang �/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 WaS 2 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 1 It 0 in 1 It in Drapes/blinds Exterior5 2 S=>E 3 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 1`12 1 It 0 in 1 ft 4 in None None 3 E=>N 5 Metal Low-ESingle Yes 1.02 027 Y 32.4 ft2 1 It in 1 It in None None 4 N=>W 10 Metal Low-ESingle Yes 1.02 0.27 Y 18A IF 1 It 0 in 1 It 4 in None None 5 W=>S 11 Metal Low-ESingle Yes 1.11 0.27 Y 40.0 ft2 10ft0in 1It4 in None None 6 N=>W 12 Metal Low-ESingle Yes 1.02 027 Y 6.9 fP 1 It 0 in 1 It 4 in None None 7 W=>S 15 Metal Low-ESingle Yes 1.02 027 Y 18.4 112 1 ft0 in 1 It in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height ExposedWalllnsulation 1 320 ft- 320 IF 32 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholefmuse PmposedACH(50) .000254 1226 67.26 126.28 .0902 5 1 /13/2021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart# CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125W Attic 40 ft- Defaulti-eakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat N Ceiling Fans: Cooling ( ) Jan f ] Feb [ ) Mar Heating [[Xll Jan [IXl] Feb Mar [ ) Apr r Apr MayfX1 00 [XI Jun [ j May Jun Jul [[JC]] Aug [�XJj Sep Oct Oct Nov Nov Dec Dec H l[XXI] Venting Jan Feb Mar liXll E May E I] Jun [ j Jul [ ] Aug L 1 Sep OctSe X Nov Dec ThermstatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.fL 0 ft2 0 ft 0.3 BEDROOM DefaulglI lbs/sq.ft. ft' ft 0.3 WIC Default(8lbs/sq.f . ft' ft 0.3 M. BATH Default(8lbs)sq.fL ft. ft 0.3 KITCHEN Default(8lbs/sq.fL ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(81bs/sq.ft. ft' ft 0.3 GREAT/DINING 1/13/2021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.fL fP ft 0.3 CLOSET2 Default(B Ibs/sq.ft. ft' ft 0.3 BATH 2 Default(8lbs/sq.ft. ft2 ft 0.3 POWDER Default 8lbs/s .fL ft• ft 0.3 SITTING ROOM 1/13/2021 7:44 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GEMINI IMPACT Builder Name: WYNNE BUILDING CORP. Street Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an droppedg ceiling/soffit /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fireqnrinkler cover Hates and walls or ceilincs isyccrwi i vi ivy waus snap ve in accorcance w¢n me provisions or juL; cuu. 1/13/2021 7:45 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" Description a. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.27 b. U-Factor: Sgl, U=1.11 SHGC: SHGC=0.27 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A , FT. PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1507.80 ft- b. Frame - Wood, Adjacent R=11.0 256.00 W 1 c. N/A R= ft- 2 d. N/A R= ft2 Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1839.00 ft2 1839 b. N/A R= ft2 Area c. N/A R= ft2 12. Ducts, location & insulation level R ft2 115.28 ft� a. Sup: Attic, Ret: Attic, AH: Attic 6 125 40.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 3.318 ft. 0.270 Area ft� 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature _ \ Builder Signature, Date: Address of New Home:��A �� ! � City/FL Zip: � p kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.95 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 7:45 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoft® Project Summary o: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE UN., Fr. PIERCE, FL 34946 Phone: 772-4666799 FaX 772-0566796 Email: OUICKCALCS@AOL.COM Project• • For. THEGEMINI WYNNE DEV., FT. PIERCE, FL Notes: Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 Inside db 70 OF Inside db 75 °F Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21011 Btuh Structure 19448 Btuh Duds 6289 Btuh Central vent (0 cfm) 0 Btuh Duds Central vent (0 cfin) 9502 0 Btuh Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27300 Btuh Use manufacturer's data n Infiltration Rate/swing ltiplier 0.95 Equipment senmus ble load 27502 Btuh Method Simplified Construction quality Averag Latent Cooling Equipment Load Sizing Fireplaces 0e Structure 2170 Btuh Duds 2599 Btuh Central vent (0 cfm) 0 Btuh Area (th) He,tB'1n3g Coolin3g (none) Equipment latent load 4768 Btuh Volume (fP) 155822 15582 Airchangeslhour 0.38 0.20 Equiv.AVF (dm) 99 Equipment Total Load (Sen+Lat) 32271 Btuh 52 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536MO30 AHRI ref 7914585 Coil FX4DN(B,F)037 Efficiency 85 HSPF . AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Heating input Heating output 34600 Btuh@47-F Sensible000ling Latent000ling 24360 10440 Btuh Stuh Temperature rise 27 OF Actual air flow 1160 cfm Total cooling Actual air flow 34800 1160 Btuh dm Airflowfador 0.042 dm/Btuh Static pressure 0.50 in H2O Airflowfador Static 0.040 cfrdBtuh Space thermostat pressure Load sensible heat ratio 0.50 0.86 in H2O Capacity balance point = 36 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrghtsoft- Ri9FtSute@Urivemal 201919.021 RSU08101 2021-Jarv1307:44:09 A ...UICKIDow &\WngHmft WAQWYNNE-GEMINinp Calc=MI6 Frortl)oorfaces N Paget r{a wrghtsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUGE LN., FT. PIERCE, F 34946 Phore: 772-466-6799 Fax 712466-6796 Emil: QUICKCALCS@.OL.COM 1 Room name Entire House M4STER BEDROOM 2 Etposadwll 2120 ft 43.0 ft 3 Room height 8S ft d 8.0 ft heaYmol 4 5 Room dimensions Room area 1839.0 fF 1.0 x 343.0 ft 343.0 iF Ty Construction U-value Or HTM Area Load Area number (BWhW-'g Pump) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 t7/ 13A-0as 7A lw 4A5-20m 0.143 1270 0.770 n n n 4.00 3556 2156 2.55 34.77 19.31 628 7 19 602 0 0 2412 247 407 1533 241 365 0 0 0 0 0 0 0 0 0. - 0 0 0 11 13A4ots 1Actan 0.143 1270 a a 4.00 3556 255 8729 152 33 98 2 394 1162 250 2853 0 0 0 0 0 0 0 0 W 11DO 13A-4= 0.390 0.143 a 5 10.92 4.00 11.31 2.55 21 473 21 466 229 1868 238 1187 0 232 0 232 0 929 0 591 1Aciom 1270 s 3556 34.77 7 7 247 241 0 0 0 0 13A4os IA-dom 4A5-20m 4A5-2oW 12C-Ow 0.143 1270 0.770 0.470 OD91 w w w w - 4.00 3556 2156 13.16 2.55 2.55 5525 44.72 35.61 128 295 33 19 41 224 203 2 2 2 224 813 1162 407 537 571 517 1806 845 1453 287 112 33 0 0 0 79 2 0 0 0 318 1162 0 0 0 202 1806 0 0 0 P C F 16A-30md 22A-tpl 0A32 0.989 - - 0.90 2T69 2.32 0.00 1839 1839 1839 212 1648 5871 4256 0 343 343 343 43 307 1191 796 0 6 c)AED exwrsion 508 618 Ernelope loss/gain 17975 16592 3907 4012 12 a) Wilration b) Roomlentilabon 3037 0 896 0 674 0 190 0 13 Intenialga. Oavpan5@ 230 0 0 0 0 Applianoesodler 2000 0 Subtotal (lines6to 13) 21011 19448 4581 4202 14 15 LesselA;mal load Lesstiansler Redistibuton Subtotal Dud loads 30% 49% 0 0 0 21011 6289 0 0 0 19448 9502 30% 49% 0 0 0 4581 1371 0 0 0 4202 2053 Total room load Airrequired(dm) 27300 1160 28950 1160 5952 253 6255 251 Calculations approved byACCAto meet all requirements of Manual J 8th Ed - wr�9htsoTt' 2021 Jart1307:4499 RgltSute®Uriwrsal201919.021 RSU08101 Page 1 ...UICMDo rLs Wdglcnft WAMWYNNE-GEMINInp Calc=M18 Frord Doorfaoes: N wrightsofi Right-M Worksheet Aix Entire House Data: QUICK CALCS, INC. By. 317 ST. LUCIE UL, Fr.. PIERCE, FL 34946 Plore: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MBATH 2 Bposedwall 0 It 8.0 It 3 Room height 8.0 ft heaV000l 8.0 It healb3ol 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room area 63.0 fF 56.0 fF Ty Conshuction U-value Or HTM Area Load number (Btuhdk-q (BWh4l0 or perimeter (ft) (Bfuh) or�perim� (it) (BWh) Heat Cool Gros; NIPS Heat Cool G. NAPS Heat Cool 6 13A-4= 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-d= 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21-% 19.31 0 0 0 0 0 0 0 0 V�/ 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 I—G 1Ac1om 1270 a 3556 8729 0 0 0 0 0 0 0 0 �D 11D0 0.3W a 10.92 11.31 0 0 0 0 0 0 0 0 t13AA= 0.143 s 4A0 2.55 0 0 0 0 -64 57 228 145 —G 1A-c1= 1270 s 3556 34.77 0 0 0 0 7 7 247 241 y! 13A-4as w 2S5 0 0 0 0 0 0 0 0 1270 1270 w 5M 5525 0 0 0 0 0 0 0 0 4A5-2= 4PS2om 0.470 w 2156 2156 0 0 0 0 0 0 0 0 ���GCG, 4Ai2ovd 0.470 w 13.16 35.61 35.61 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2S5 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 56 66 50 130 F 22A-tpi 0.9m - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AEDe=rston -12 .47 Envelope loss/gain 56 134 747 469 12 a) IMltation 0 0 125 35 b) Rcomverltlafion 0 0 0 0 13 Intemalgaim C=pants@ 230 0 0 0 0 Applianresbtw 0 0 Subtotal (Iinesft 13) 56 134 872 505 L.essexerral load 0 0 0 0 L.es;tansfer 0 0 Redistibu5on 0 0 0 0 14 Subtotal 56 134 872 505 15 Ductloads 30% 49% 17 65 30% 499/6 261 247 Total room load 73 199 1 1133 751 Airrequired (c1m) 3 8 48 30 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -4j e 2021Jar-1307:4409 .9 A Right-SU1LOLMversa1201919.021 RSU08101 Paget ...UICIODoamertslWdgMnllHVAQWYNNE-GEMNI.np Calc=M78 Frort Doorfams: N wrightsoft• Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317SLLUGE LN.,FC PIERCE, FL34946Ptore:772-466-6799 Fax772-46"796 EmaiI:OUrKCALCS4@40LCOM 1 Room name IGTCHEN ROSTER BEDROOM2 2 Eosedwall 8.0 ft 510 ft 3 Room heght 8.0 ft heatlmol 8.0 ft heatlm01 4 Rcom dimenscas 10 x 1720 ft 1.0 x 256D ft 5 Room area 1720 IF 256D R Ty Conoxion U-value Or HTM Arm Load Am (meter mmw (BWW*n (BWh" or pedm� (1t) @Wh) or peri(A) (BWh) Heat Cod Gros NtPS Heat Cool Cross NrPS Heat Cool 6 Yy 13A4= 0.143 n 4.00 2S5 0 0 0 0 192 -192 769 489 �C 1Aatan 1270 n 3556 34.T/ 0 0 0 0 0 0 0 -0 �C 4A5-2wn a770 n 21.56 1931 0 0 0 0 0 0 0- . 0. �1 13A-4ors 0.143 a 400 2S5 0 0 0 0 104 71 286 182 11 1—G �D IA-dm 1.2n a 351% 8729 0 0 0 0 33 2 1162 21353 11DO 0.390 a 1092 1131 0 0 0 0 0 0 0 0 W 13A4ars 0.143 s 400 2.55 - 0 0 - 0 0 112 - 112 448 285 LG 1A-d m - 12M s 35.56 34.77 0 0 0 0 0 - 0 0 0 1344o s 0.143 w 400 2.55 0 0 0 0 0 0 0 0 IAIorn 1270 w 3556 5525 0 0 0 0 0 0 0 0 4As` tom 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-2o1d 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 P 12C-056V 0.091 - 255 128 64 64 163 82 0 0 - 0 0 C 16A30md OD32 - 0.90 232 172 172 154 399 256 256 229 Sm F 22A1pl 0989 - 27.69 0.00 172 a 222 - 0 256 - 51 1412 - -0 6 c)AEDemnsion -211 -176 Emebpelossrgain 539 270 4307 4227 12 a) Mtrabon 0 0 800 226 b) RcomwnAla#w 0 0 0 0 13 4lternal gains O=pants@ 230 0 0 0 0 Applianos/oft�er 2000 0 Subto6l(lmes6to13) 639 2270 6106 4452 Lesexbmalload 0 0 0 0 Lesstarder 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 539 2270 5106 4452 15 Ductloads 30-A 49% 161 1109 30%1 499% 1528 2175 Total room load 70030 33B0135 em 627 6266 Airmquimd(dm) 282 Calculations approved byACCAto meet all requirements of Manual J 8th Ed c - wr--off 2021-Jan1307A4A9 .9G�LA fZgtYNNE-GEMINLrtp C lc=MIB1 Rort Doo81 1 Page ...UICI(�airer�\Wd9tl=oR HVAG\WMPJE-GEMINInp CaIc=MB Frortpaor�ces N I wrightsoft° Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Pfore: 772A66-6799 Fax:772-465-6796 Erreil: OUICKCALCS@AOL.COM 1 Room mrrme ENTRY LAUNDRY 2 Bposedwall 20.0 It 13.0 ft 3 Room height 8.0 ft heal/000l 8.0 it heatlmol 4 Room dimensions ID x 83.0 it 7.0 x 6A It 5 Room area 83.0 fF 42.0 fF Ty Consh;cion U-value Or HTM Area Load Area (in Load number (BblhfiF-°FF) (BWhW) or penm� (ft) (Bluh) or perimeter (it) (Byh) Heat Cool Gross NP/S Heat Cool Gros N/PS Heat Cool 6 13AAM 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 �C :G tAclom 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A&2om 0.770 n 21M 19.31 0 0 0 0 0 0 0 0 13A-0as 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 11 1Ac1om 1270 a 3556 8729 0 0 0 0 0 0 0 0 D 1100 0.390 a 1092 1131 21 21 229 238 0 0 0 0 V,J �!- 13AAocs 0.143 s 4A0 2.55 8 8 32 20 48 48 192 - 122 1Actom 1270 s 3556 3477 0 0 0 0 0 0 0 0 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 N13AAocs 1Aclom 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A5.2o(d 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 P 120-0sx 0.091 - 2,55 128 104 104 265 133 56 56 143 72 C 16A-30md 0.032 - 0.90 2.32 83 33 74 193 42 42 38 97 F 22A-ptl 0.989 - 27.69 0.00 83 20 554 0 42 13 360 0 6 c)AEDemusion -% -27 Envelope loss/gain 1263 595 733 264 12 a) Infiltration 110 31 94 27 b) Room ventilation 0 0 0 0 13 Internal gains Occupants@ 230 0 0 0 0 Applianoas/olher 0 0 Subtotsl(lines6to13) 1372 625 827 291 Lesextsmalload 0 0 0 0 Lestransrer 0 0 0 0 Redistribution cn 0 0 0 0 14 Subtotal 1372 625291 827 15 Duct loads 30% 49% 411 306 30% 49% 247 142 142 Tod 1783 931 1 1074 433Airare� 76 37 46 17 Calculations approved byACCAto meet all requirements of Manual J 8th Ed -r Id- wri9ft>< ft- 2021-Jar1307:44.09 AAA fd9ttSufe@Uriversal201919.021 RSU08101 Page4 -.UICK10oamerts\WdgtbDft HVACWYNNE-GEMINInp Calc=M78 Frort Doorfares: N wrightsoft, Right-M Worksheet Job: Entire House pal QUICK CALCS, INC. By. 317ST. LUCIE LN.,Fr. PIERCE, FL34946 PIane:772-4666799 Fac772-0 667% Emil: QUICKCALCS@40LC0M 1 Room name GREATIDINING CLOSET2 2 Eposedwall 39.0 It 0 ft 3 Room height 8.9 1t heaVmol 9.4 It heaf/owl 4 Room dimensions 10 x 568A it 7.0 x 8.0 it 5 Room area 568.0 W 56.0 fP Ty Construction U-value or HTM Area (1P) Load Area (fl` Load number (BbhAk-F) (BWhAF) or perimeter (ft) (Bbh) or perimeter (t) (Bbh) Heat Cool Gross N/RS Heat Cool Gross NrP/S Heat Cool 6 Vj/ 13A� 0.143 n 4.00 255 267 248 993 632 0 0 0 0 1Aatom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 L�CG 4A5-2om 0.770 n 2156 19.31 19 0 407 365 0 0 0 0 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 tAclom 1270 a 3556 8729 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 1344oc8 0.143 s 4.00 255 0 0 0 0 0 0 0- 0 1Actom 1270 s 3556 34.77 0 0 0 0 0 0 0 -0 13AA= 0-143 w 4.00 2.55 so 39 167 100 0 0 0 0 1A-ctom 1270 w 35.56 5525 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-2M 0.470 w 13.16 35.61 41 2 537 1453 0 0 0 0 P 12C-0av OD91 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 568 568 509 1318 56 56 50 130 F 22A-tpl 0.989 - 27.69 0.00 568 39 1080 0 56 0 0 - 0 6 c)AEDe=rsion 256 -11 F_melope lossfgain Sw 4123 50 119 12 a) WIMon 680 192 0 0 b) Roomventilation 0 0 0 0 13 Internal gain Omrpants@ 230 0 0 0 0 Appliancesbfier 0 0 Subtotal (lines6to 13) 4364 4315 50 119 Less aternal load 0 0 0 0 Lesstran4er 0 0 0 0 Redissibuton 0 0 0 0 14 Subb61 4364 4315 50 119 15 Duct loads 30A 49% 1306 2108 30% 49% 15 58 Total Ipom load 5671 6423 s3 177 Airrequired (dm) 241 257 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wNgFrtsot'!- A FZgft6ute®Urivefsa1201919.021 RSU08101 2021-Jarv1307:44t19 ��-Zc ...UICKIDoamertsiWdgttsoft HVAQVVYNNE-GEMINIxW Calc=MI8 Fror¢Doorfaw& N PageS wrightsoft RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, Fr. PIERCE. FL 34946 Prune: 772a66-6799 Fax: 7724666796 Email: QUICKCALCS@A.OL.COM 1 Room name BATH 2 POWDER 2 EVOSedwall 8.0 It 0 ft 3 Room height 9.4 ft heaVoDol 9.4 It heatbool 4 Room dimensions 6.0 x 8.0 It 7.0 x 6.0 It 5 Room area 48.0 IF 42.0 IF Ty Construction U-value Or HTM Area Load ea Load number (&uhfiF-*n (BWh/F) or perim� (ft) (Bhih) orpedmeees (ft) (Btuh) Heat Cool Gross NUPS Heat Cool Grins NIPS Heat Cool 6 Vtl 13A-0as 0.143 n 4.00 Z55 75 68 273 174 0 0 0 0 �1Ac'1om 1270 n 3556 34.77 7 0 247 241 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 a. 13A-0as 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 1Aclom 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 13A4ors 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 s 3556 34.77 0 0 0 0 0 0 0 0 VVVjjtlll 13Avh4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclorn 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-2oW 0.470 w 13.16 35.61 0 0 0 0 0 0 0 0 P 12C-0av 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0-M - 0.90 2.32 48 48 43 111 42 42 38 97 F 22A-Ipl 0289 - 27.69 0.00 48 8 222 0 42 0 0 0. 6 c)AED exvrson -08 -8 Envelopelo-dgain 784 478 38 89 12 a) Infltraton 147 42 0 0 b) Room ventilation 0 0 0 0 13 Intanal gains Occupants@ 230 0 0 0 1 0 Applianoes(other 0 0 SubtoW(linesfito13) 932 520 38 89 Lesse)demlload 0 0 0 0 Lesstransfer 0 0 0 0 Redisbibution 0 0 0 0 14 Sublotzl 932 520 38 89 15 Dudloads 30% 49% 279 254 30% 49% 11 44 Total room load 1211 773 49 133 Air required (dim) 51 31 2 5 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wrtoft oR- 2021-Ja 1307:44.09 9911SUte®thtWe 1201919.021 RSU08101 Page _.UICKtDownertslWngttsoft HJACIWYNNE-GEMINI.np Calc=92 Frond Doorfaom N wrightsoft, Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, Fr. PIERCE, FL 34946 Phore: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCSOAOL.COM 1 Room name DEN 2 E.Voced wall 22D ft 3 Room height 9.4 it hwV=l 4 Room dimensions 11,0 x 10.0 ft 5 Room area 110.0 ft' Ty Construction U-value Or HTM Area (fly Load Area Load number (Bluhfit;°F) (Btaw) or perimeter It (Btuh) or perimeter Heat Cool Gros NP,S Heat Cool Gross N,P5 Heat Cool 6 V[13A40M 0.143 n 4.00 255 94 94 376 239 I�—(C 1Ac1om 1270 n 3556 34.77 0 0 0 0 4A5-2om 0.770 n 21M 19.31 0 0 0 0 13A-0as 0.143 a 4.00 2.55 0 0 0 0 1t 1Ac1cm 1270 a 3556 8729 0 0 0 0 11DO OM% a 1022 11.31 0 0 0 0 13A-0ocs 0.143 s 4.00 255 9 9 38 24 1Ac1am 1270 s 35.56 34.77 0 0 0 0 13AAors 0.143 w 4.00 255 103 84 338 215 IAclom 1270 w 35.56 5525 0 0 0 0 4AS2am 0.770 w 2156 44.72 19 2 407 845 4A5-2M 0.470 w 13.16 35.61 0 0 0 0 P 12C-0sx 0.091 - 2S5 128 0 0 0 0 C 16A-Mmd 0.032 - 0.90 2.32 110 110 99 255 F 22A-Ipl 0.989 - 27.69 OAO 110 22 609 0 6 c)AED exarson 1T'233 Ernelope los/gain 1868 12 a) Infiltration 405b) Roomwnfilafion 013 Intemal gairs Occupants@ 230 0 Appliancesother Sub4rtal(lines64r 13) 2273Lessextemalload 0Lesstransfer 0Rediistribution 014 Subtotal 227315 Dud loads 30% 49% 680 Total room load 2953 2867 Air required (dm) 125 115 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed ' .e.righe�oft- zozl-aa.,lao7:44os i4C A RWYNN -GEMI I.rLp 01919.021 RSUOSt01 Page7 ...UICKIDoamer6\Wdgtfmft HVAC\WYNNE-GEMINI.np CaIc=MI6 FrorApoorfa�s: N - wrightsoft® Duct System Summary o; Entire House By. QUICK CALCS, INC. 317 ST. LUCIE UN., Fr. PIERCE, FL $4946 Phone: 772-466-6799 17 z 772-466-6796 Emil: QUICKCALCS AOLCOM Project Information For. THEGEMINI WYNNE DEV., FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0250 / 0.250 in H2O 0.286 in/100ft 1160 cfm 175 I Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.286 in/100ft 1160 dm Name Design (Btuh) Htg (cfm) Cig (cfin) Design FR Diam (in) H x W (in) Dud Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1211 51 31 0.368 4.0 OxO VIFx 21.0 115.0 st1 CLOSET2 c 177 3 7 0.363 4.0 OxO VIFx 22.6 115.0 st1 DEN h 2953 125 115 0.289 7.0 Ox0 VIFx 38.1 135.0 st2 ENTRY h 1783 76 37 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAVDINING-A c 3211 120 129 0.300 6.0 OxO VIFx 31.7 135.0 st2 GREAT/DINING-B c 3211 120 129 0.308 6.0 Ox0 VIFx 27.3 135.0 s12 KITCHEN C 3380 30 135 0.376 7.0 OxO VIFx 18.1 115.0 st1 LAUNDRY h 1074 46 17 0.369 6.0 OxO VIFx 20A 115.0 st1 A. BATH h 1133 48 30 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 MASTER BEDROOM h 2976 126 125 0.286 6.0 OxO VIFx 40.1 135.0 st2 MASTERBEDROOM2 h 6635 282 266 0.352 7.0 OxO VIFx 27.2 115.0 st1 MASTERBEDR00%A h 2976 126 125 0.297 6.0 OxO VIFx 33.1 135.0 st2 POWDER c 133 2 5 0.379 4.0 OxO VIFx 17.1 115.0 st1 WIC c 199 3 8 0.309 4.0 OxO VIFx 26.6 135.0 s2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Dud Name Type (cim) (CIm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 622 631 0.286 803 12.0 0 x 0 VnlFlx st1 st1 PeakAVF 1084 1123 0.286 804 16.0 0 x 0 VinlFlx ' wrightsof' 2021Ja 1307:44:09 Righ-SUL-SUrivarsal 201919,021 RSU08101 Pagel ...UICK1CowrerlslWrigitnt HVAQWYNNE-GEMINinp Caic=MlB Fror¢Doorfaces: N Name Grille Size(in) Htg (dm) cig (dm) TEL (ft) Design FR Uemc (ipm) Diam (in) HxW (in) Sud/Joist Opening(in) Dud MaU Trunk rb1 Ox0 1 1160 1160 0 0 0 0 Ox 0 MR wrightsofV 2021-Jarv1307:64:09 A—.��.., RigitSO� UtUriW=1201919.027 RSU08101 _.UIC(00a riS\W69gtoftHVAQWVNNE-GEMINInp Calc=MM FmftDoorfaces:N Paga2