Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM Florida Building Code Online Page 1 of 2 Business & Professional Regulation BCIS Home1 Log In I User Registration ! Hot Topics Submit Surcharge I Stats&Facts f Pubkcatio,is C-"Ia�t Us BC[S Site Map 11 Links Search FI rda a Product ApprovalUSER-Public User Prod ct Aopraval Menu>Product or Application Search>Application List>Application Vetail FL# FL1654-R27 Application Type Revision Code version 2020 Application Status Approved Comments Archived - Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach,FL 33442 (954)233-1330 Ext242 ma(pert@po lygl ass.com Authorized Signature Maury Alpert ma pert@polyglass.cum Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)8D2-8017 uspclyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email II II West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechnical(P polygl ass.cam Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/07/2022 Validated By Sohn W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL1654 R27 COI 2020 01 COI NIEMINEN. df Referenced Standard and Year(of Standard) Standard Year ASTM D4601 2012 ASTM D4897 2009 ASTM D6162 2015 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 https://Www.floridabuilding-org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bn... 1/12/2021 Florida Building Code Online Page 2 of 2 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Sunmitted 10/02/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/12/2020 Date Approved 12/15/2020 Summary of products FL# Mode[,Number or Name Description 1654.1 Polyglass Modified Bitumen Roof SBS and APP modified bitumen roof systems Systems Limits of Use Installation Instructions Approved for use in HVHZ:No FL1654 R27 II 2020 09 30 FINAL Al ER PG MODBIT FL1654- Approved for use outside HVHZ:Yes 2R 7.pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure I-N/A(-622.5 Created by Independent Third Party:Yes Other: 1.)The design pressure in this application Evaluation Reports relates to one particular assembly over concrete deck. FL1654 R27 AE 2020 09 30 FINAL ER PG MODBIT FL1654- Refer to the ER Appendix for other systems and deck R27,Ddf types. 2.) Refer to ER,Section 5 for other Limits of Use. Created by Independent Third Party:Yes 3.) Refer to FL16717 for HVHZ jurisdictions. Back Ne-t Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:$50-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::Ar gssibllity Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity,instead,contact the office by phone or by traditional mai€.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,r.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record,if you do not wish to supply a personal address, please provide the Department with an email address which ran be made available to the public.To determine if you are a licensee under Chapter 455,P.S.,please click here, Product Approval Accepts: ®®gi�E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgvgqu?w`/o2bn... 1/12/2021 APPENDtX 1:ATTACHMENT RKII)TREMENTS FOR WIND UPLIFT RESISTANCE ONEMO[etc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood Newor Reroof(Tear-Off) A-1 Bonded insulation,Bonded Root Cover 5 1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-12 iC Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Banded Insulation,Bonded Roof Cover 12-14 1D Wood New,Reroof(Tear Off)or Recover 9-1 Mech.Attached Base Insulation,Bonded Top Insu€atioo,Bonded Roof Cover 14-15 1E Wood New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 15-19 1F Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19-23 1G Woad New or Reroof{Tear-Off) E-2 Non-insulated,Mech.Attached Base Sheet(nails),Bonded RoofCover 23-29 1H Wood New,Reroof(Tear-Off)or Recover E-2 Nan-insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 29-36 11 Wood Newmriteroof{Tirar-Off) F 37 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover 8-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 38-43 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Root Cover 44-50 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Banded Roof Cover 51-53 2D Steel or Structural concrete New,Reroof(Tear-Off)cr Recover D-2 Insulated,Mech.Attached Vefociflex,Bonded Roof Cover 53-55 3A Structural concrete New or Reroof(fear-Off) A-1 Bonded Insulation,Bonded Rouf Cover 56-68 3B Structural concrete New or Reroof(Tear-Off) F Non-insulated,Bonded Roof Cover 68 4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 69-73 4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Banded Insulation,Banded Roof Cover 73-47 4C Lightweight concrete New or Reroof(Tear-Oft) E-2 Nan-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 74-7B 5A Cementitious wood fiber Reroof(Tear-Off) A-1 Banded insulation,Bonded Roof Cover 79-80 5B Cementitious wood fiber Reroot{Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Banded Roof Cover 80-82 5C Cementitious wood fiber Reroof{Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 82 SD Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mech,Attached Insulation,Bonded Roof Cover 83 5E Cementitious wood fiber Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 83 6A Existing gypsum Rercof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 84-8$ 68 Existing gypsum Reroof(Tear-Cff)or Recover A Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 88 6C Fxisting gypsum Reroof(7ear-0ff)or Recover C-1 Mech.Attached Insulation,Banded Roof Cover 88 6D Existing gypsum Reroof(Tear-Off)or Recover E-2 Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 88 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 89-94 7B Various Recover F Non-Insulated,Bonded Roof Cover 94 NEMO ETC,LLC Evaluation Report 1`9290.02.06-R25 for FL1650-R27 Certificate of Authorization 432455 7^'EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/3 0120 2 0 02018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 1 of 94 ON Emo I etc. MEMBRANE ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Self-adhering (followed 565-SA-H Base Ply Elastobase SA Isns,selPntlhedng Rrbrfd sntems} by torch applied sheet] Base Ply One or more plies Elastollmr SAV,Elastaflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR,Elastoflex SA Base HD SBS-SA Cap?IV EtalsbaffexSk P,Elastoflex SA P FR,Polyreflect Self Adhering (SEIS,Self-Adhanng) Note: Unless otherwise noted,permissible membrane substrates for SBS-SA we limited to the SBS-SA Base Ply options herein, Elastobose(poly/sand)or E(ostobase(poly/poly). PG350 at 1.5-2.0 APP-CA1 Cap Ply Polyflex G FR gal/square APP-TA Base Ply or Ply One or more plies Polygfass Base,PolVflex,Polybond Torch-Applied (APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR APP-SA-H Base PlyPolyflex SA Base by torchering(followeddsh ) Yf by torch-applied sheet] (APP,5eFAtlhefiAg,Hybrid Systems) Cap Ply Polyflex SA P,PolVflex SA P FR,PolyfreskD G SA,Polyfresko G SA FR,Polykool APP-SA Note: Unless otherwise noted,permissible membrane substrates for APP SA are limited to the 585-SA Base Plyoptions herein, Self-Adhering (APP,Self-Adhering) Efastobose(polyfsandj or Elnstobase(polyfpoly)- 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations.The iesser ofthe MOP listings below v5,those in Table 3A applies, VAPOR BARRIER OPTIONS;STRUCTURALCoNCRFTE DEcR;FOLLOWED BYADHESIVE-APPUED INSUUOTON PER TARLF 3A: OPTION VAPOR BARRIER INSULATION ADHESIVE MDP S PRIMER TYPE(NOTE 15) APPLICATION (P ) 0-VB-1. 7G1OD Elastoflex SA V Plus Self-Adhering D-I5 or CR-20,12-inch o.c. -60.0 C-VB-2. PG100 Polyglass ease Torch-applied 0-15 or CR-20,12-inch o.c. -75.0 C-VB-3. PG100 Elastoflex SAP Self-Adhering D-AS,12-incho.c. -75.0 C-VB-4. PG1OU Elastoflex SAP Self-Adhering M-05FA,12-inch o.c. -157.5 C-VAS. PC100 Elastoflex SAP Self-Adhering CR-20,1.-inch o.c. -270.0 C-V&6. PG10D Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR Self-Adhering M-0SFA,M-PG-1,05500 or CR-20,12-Inch o.c. -290.0 C-VB-7. PG200 SBS-TA(with sanded-top-surface) Torch-applied M-OSFA,M-PG-S,OBSOO or CR-2D,finch o_c. -290.0 17 The folowing surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings rocfcoatings for applloation itmitations and a Roofing Materials Directory for fire ratings associated with coating usage. SUMMING OPTIONS FOR POLYGIASS MODIFIED BITUMEN ROOF SYSTEMS OPTlONX SURFACING FLORIDA PRODUCT APPROVAL SURFl. PG 300 FL10291 SURF-2. PG 600 FL10291 SURF-3. PG 550 FL10291 —TURF-4. PG 70C PL10291 SURF-S, PG 700 QS FL10291 SURF6. PG 800 FL70291 SURF-7. Polyplus60 FL1D291 MEMO ETC,LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127 Certificate of Authorization 43245-S 701 EDITION(2020)FBC NON-HVHZ EVALUAT40N Revision 25:09/30/2020 ©2018 NEW ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 4 of 94 OMEMO I etc. BONDEDTABLEII:WOOD DECKS-NEW CONSTRUCTION oR R EROOF(TEAR-Orl') SYSTEM TYPE F:NON-INSULATED, ROOF COVER System Roof Cover(Note 15) MDP(psf1 Na deck(Note 11 Primer _-Treatment Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: APA rated, Elastoflex SA V Plus 7/16 CAT, 05B Joints are covered with 4-inch wide strips of Elastoflex SA V,rolled into {Optional)585-SA,SBS- SOS SA,APP-SA, None 52 S W-208 0.419 in., place to create continuous bond. or Elastoflex SA V TA APPTA SBS-TA,APP-TA Plus FR Exposure 1 OSB Miff,15/3Y 535-SA (O;rtion�F)SBS-SA,SBS- 565=5A,APRSA, -90.0 inehl*,Vao& None Vd-294 Narre TA,APPTA SBS T TAA,APP- W 2,10 Min.IS(32- PG100 None SBS-SA (Optional)SBS-SA,S85- SBS-SA,APP-SA, g75 inch plywood TA,APP-TA SBS-TA,APP-TA Min,15/32- Plywood joints are covered with flinch wide strips of Fiastoflex SA V Plus,rolled Elastoflex$A V or (Optional}SSS-SA,SBS- SBS-SA,APP-SA, -97.5 W-211 inch plywood (Optional)PG 100 into place to create continuous bond. Elastoflex SA V FR TA,APP TA SBS-TA,APP-TA W-212 Min,15/32- POLYBRITE 745 None SBSSA (Optional{SOS SA,SBS- SBS-SA,APP-SA,TA SBS-TA APP-TA -105.0 inch plywood or WB3000 TA,APP- , Elastoflex SA V Plus Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled or Elastoflex SA V (Option l)SBS-SA,SBS- SBS-5A,APP-SA, -135.0 W-213 inch pl {Optional)PG100 into place to create continuous bond. TA,APP-TA 565-TA,APP TA ywo od Plus FR HYBRID SYSTEMs WITH SELF-ADHERING APP BASE PLY: W-214 Min.15132- (Optional)PG100 None APP-SA-H (Optional)APP-TA APP-TA -90.0 inch plywood W-215 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled APP-SA-H (Optional)APP-TA APP-TA -135.0 inch plywood into place to create continuous bond. HYBRID SYSTEMS Wall SELF-ASHERING SBS BASE PLY: E Min.15132- None None SBS-SA-H (Optional)SBS-TA 565-TA -90.0 inch plywood Min,15/32- PG100 None SBSSA-H (Optional)SBS-TA SBS-TA -97.5 nch plywood Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled SBS-5A-H (Optional)SBS-TA SBS-TA -97.5 inch plywood into place to create continuous bond. W-219 Min.15/32- POLYHRITE 745 None SBSSA-H (Optional)SBS-TA 565TA -105.0 inch plywood Or WB3000 NEMO tiTC,11C Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization#32455 7-EDITION(2070)fBC NON-HVHZ EVALUATION Revision 25:09/30/2020 V2018 NEM{S ETC,LLC Polyglass ModiRed Bitumen Roof System5,14541 233-1330 Appendix 1,Page 37 of 94