HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM Florida Building Code Online Page 1 of 2
Business & Professional Regulation
BCIS Home1 Log In I User Registration ! Hot Topics Submit Surcharge I Stats&Facts f Pubkcatio,is C-"Ia�t Us BC[S Site Map 11 Links Search
FI rda
a
Product ApprovalUSER-Public User
Prod ct Aopraval Menu>Product or Application Search>Application List>Application Vetail
FL# FL1654-R27
Application Type Revision
Code version 2020
Application Status Approved
Comments
Archived -
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext242
ma(pert@po lygl ass.com
Authorized Signature Maury Alpert
ma pert@polyglass.cum
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)8D2-8017
uspclyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email II II West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical(P polygl ass.cam
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/07/2022
Validated By Sohn W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL1654 R27 COI 2020 01 COI NIEMINEN. df
Referenced Standard and Year(of Standard) Standard Year
ASTM D4601 2012
ASTM D4897 2009
ASTM D6162 2015
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
ASTM G155 2013
FM 4470 2016
https://Www.floridabuilding-org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bn... 1/12/2021
Florida Building Code Online Page 2 of 2
FM 4474 2011
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Sunmitted 10/02/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
Summary of products
FL# Mode[,Number or Name Description
1654.1 Polyglass Modified Bitumen Roof SBS and APP modified bitumen roof systems
Systems
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL1654 R27 II 2020 09 30 FINAL Al ER PG MODBIT FL1654-
Approved for use outside HVHZ:Yes 2R 7.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure I-N/A(-622.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure in this application Evaluation Reports
relates to one particular assembly over concrete deck. FL1654 R27 AE 2020 09 30 FINAL ER PG MODBIT FL1654-
Refer to the ER Appendix for other systems and deck R27,Ddf
types. 2.) Refer to ER,Section 5 for other Limits of Use. Created by Independent Third Party:Yes
3.) Refer to FL16717 for HVHZ jurisdictions.
Back Ne-t
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:$50-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida ::Privacy Statement::Ar gssibllity Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity,instead,contact the office by phone or by traditional mai€.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,r.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record,if you do not wish to supply a personal address,
please provide the Department with an email address which ran be made available to the public.To determine if you are a licensee under Chapter 455,P.S.,please
click here,
Product Approval Accepts:
®®gi�E
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgvgqu?w`/o2bn... 1/12/2021
APPENDtX 1:ATTACHMENT RKII)TREMENTS FOR WIND UPLIFT RESISTANCE ONEMO[etc.
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood Newor Reroof(Tear-Off) A-1 Bonded insulation,Bonded Root Cover 5
1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-12
iC Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Banded Insulation,Bonded Roof Cover 12-14
1D Wood New,Reroof(Tear Off)or Recover 9-1 Mech.Attached Base Insulation,Bonded Top Insu€atioo,Bonded Roof Cover 14-15
1E Wood New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Roof Cover 15-19
1F Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 19-23
1G Woad New or Reroof{Tear-Off) E-2 Non-insulated,Mech.Attached Base Sheet(nails),Bonded RoofCover 23-29
1H Wood New,Reroof(Tear-Off)or Recover E-2 Nan-insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 29-36
11 Wood Newmriteroof{Tirar-Off) F 37
2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover 8-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 38-43
2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mech.Attached Insulation,Bonded Root Cover 44-50
2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Banded Roof Cover 51-53
2D Steel or Structural concrete New,Reroof(Tear-Off)cr Recover D-2 Insulated,Mech.Attached Vefociflex,Bonded Roof Cover 53-55
3A Structural concrete New or Reroof(fear-Off) A-1 Bonded Insulation,Bonded Rouf Cover 56-68
3B Structural concrete New or Reroof(Tear-Off) F Non-insulated,Bonded Roof Cover 68
4A Lightweight concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 69-73
4B Lightweight concrete New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Banded Insulation,Banded Roof Cover 73-47
4C Lightweight concrete New or Reroof(Tear-Oft) E-2 Nan-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 74-7B
5A Cementitious wood fiber Reroof(Tear-Off) A-1 Banded insulation,Bonded Roof Cover 79-80
5B Cementitious wood fiber Reroot{Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Banded Roof Cover 80-82
5C Cementitious wood fiber Reroof{Tear-Off)or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 82
SD Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mech,Attached Insulation,Bonded Roof Cover 83
5E Cementitious wood fiber Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 83
6A Existing gypsum Rercof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover
84-8$
68 Existing gypsum Reroof(Tear-Cff)or Recover A Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 88
6C Fxisting gypsum Reroof(7ear-0ff)or Recover C-1 Mech.Attached Insulation,Banded Roof Cover 88
6D Existing gypsum Reroof(Tear-Off)or Recover E-2 Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 88
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 89-94
7B Various Recover F Non-Insulated,Bonded Roof Cover 94
NEMO ETC,LLC Evaluation Report 1`9290.02.06-R25 for FL1650-R27
Certificate of Authorization 432455 7^'EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:09/3 0120 2 0
02018 NEMO ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 1 of 94
ON Emo I etc.
MEMBRANE ADHESIVE COMBINATIONS
REFERENCE LAYER MATERIAL APPLICATION
Self-adhering (followed
565-SA-H Base Ply Elastobase SA
Isns,selPntlhedng Rrbrfd sntems} by torch applied sheet]
Base Ply One or more plies Elastollmr SAV,Elastaflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR,Elastoflex SA Base HD
SBS-SA Cap?IV EtalsbaffexSk P,Elastoflex SA P FR,Polyreflect Self Adhering
(SEIS,Self-Adhanng) Note: Unless otherwise noted,permissible membrane substrates for SBS-SA we limited to the SBS-SA Base Ply options herein,
Elastobose(poly/sand)or E(ostobase(poly/poly).
PG350 at 1.5-2.0
APP-CA1 Cap Ply Polyflex G FR gal/square
APP-TA Base Ply or Ply One or more plies Polygfass Base,PolVflex,Polybond Torch-Applied
(APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR
APP-SA-H Base PlyPolyflex SA Base by torchering(followeddsh )
Yf by torch-applied sheet]
(APP,5eFAtlhefiAg,Hybrid Systems)
Cap Ply Polyflex SA P,PolVflex SA P FR,PolyfreskD G SA,Polyfresko G SA FR,Polykool
APP-SA Note: Unless otherwise noted,permissible membrane substrates for APP SA are limited to the 585-SA Base Plyoptions herein, Self-Adhering
(APP,Self-Adhering) Efastobose(polyfsandj or Elnstobase(polyfpoly)-
16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations.The iesser ofthe MOP listings below v5,those in Table 3A applies,
VAPOR BARRIER OPTIONS;STRUCTURALCoNCRFTE DEcR;FOLLOWED BYADHESIVE-APPUED INSUUOTON PER TARLF 3A:
OPTION VAPOR BARRIER INSULATION ADHESIVE MDP
S PRIMER TYPE(NOTE 15) APPLICATION (P )
0-VB-1. 7G1OD Elastoflex SA V Plus Self-Adhering D-I5 or CR-20,12-inch o.c. -60.0
C-VB-2. PG100 Polyglass ease Torch-applied 0-15 or CR-20,12-inch o.c. -75.0
C-VB-3. PG100 Elastoflex SAP Self-Adhering D-AS,12-incho.c. -75.0
C-VB-4. PG1OU Elastoflex SAP Self-Adhering M-05FA,12-inch o.c. -157.5
C-VAS. PC100 Elastoflex SAP Self-Adhering CR-20,1.-inch o.c. -270.0
C-V&6. PG10D Elastoflex SA V,Elastoflex SA V FR,Elastoflex SA V Plus,Elastoflex SA V Plus FR Self-Adhering M-0SFA,M-PG-1,05500 or CR-20,12-Inch o.c. -290.0
C-VB-7. PG200 SBS-TA(with sanded-top-surface) Torch-applied M-OSFA,M-PG-S,OBSOO or CR-2D,finch o_c. -290.0
17 The folowing surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings rocfcoatings
for applloation itmitations and a Roofing Materials Directory for fire ratings associated with coating usage.
SUMMING OPTIONS FOR POLYGIASS MODIFIED BITUMEN ROOF SYSTEMS
OPTlONX SURFACING FLORIDA PRODUCT APPROVAL
SURFl. PG 300 FL10291
SURF-2. PG 600 FL10291
SURF-3. PG 550 FL10291
—TURF-4. PG 70C PL10291
SURF-S, PG 700 QS FL10291
SURF6. PG 800 FL70291
SURF-7. Polyplus60 FL1D291
MEMO ETC,LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127
Certificate of Authorization 43245-S 701 EDITION(2020)FBC NON-HVHZ EVALUAT40N Revision 25:09/30/2020
©2018 NEW ETC,LLC Polyglass Modified Bitumen Roof Systems;(954)233-1330 Appendix 1,Page 4 of 94
OMEMO I etc.
BONDEDTABLEII:WOOD DECKS-NEW CONSTRUCTION oR R EROOF(TEAR-Orl')
SYSTEM TYPE F:NON-INSULATED, ROOF COVER
System Roof Cover(Note 15) MDP(psf1
Na deck(Note 11 Primer _-Treatment Base Ply Ply Cap Ply
SELF-ADHERING BASE PLY:
APA rated, Elastoflex SA V Plus
7/16 CAT, 05B Joints are covered with 4-inch wide strips of Elastoflex SA V,rolled into {Optional)585-SA,SBS- SOS SA,APP-SA,
None 52 S
W-208 0.419 in., place to create continuous bond. or Elastoflex SA V TA APPTA SBS-TA,APP-TA
Plus FR
Exposure 1 OSB
Miff,15/3Y 535-SA (O;rtion�F)SBS-SA,SBS- 565=5A,APRSA, -90.0
inehl*,Vao& None
Vd-294 Narre TA,APPTA SBS T TAA,APP-
W 2,10 Min.IS(32- PG100 None SBS-SA (Optional)SBS-SA,S85- SBS-SA,APP-SA, g75
inch plywood TA,APP-TA SBS-TA,APP-TA
Min,15/32- Plywood joints are covered with flinch wide strips of Fiastoflex SA V Plus,rolled Elastoflex$A V or (Optional}SSS-SA,SBS- SBS-SA,APP-SA, -97.5
W-211 inch plywood (Optional)PG 100 into place to create continuous bond. Elastoflex SA V FR TA,APP TA SBS-TA,APP-TA
W-212 Min,15/32- POLYBRITE 745 None SBSSA (Optional{SOS SA,SBS- SBS-SA,APP-SA,TA SBS-TA APP-TA -105.0
inch plywood or WB3000 TA,APP- ,
Elastoflex SA V Plus
Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled or Elastoflex SA V (Option l)SBS-SA,SBS- SBS-5A,APP-SA, -135.0
W-213 inch pl {Optional)PG100 into place to create continuous bond. TA,APP-TA 565-TA,APP TA
ywo od
Plus FR
HYBRID SYSTEMs WITH SELF-ADHERING APP BASE PLY:
W-214 Min.15132- (Optional)PG100 None APP-SA-H (Optional)APP-TA APP-TA -90.0
inch plywood
W-215 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled APP-SA-H (Optional)APP-TA APP-TA -135.0
inch plywood into place to create continuous bond.
HYBRID SYSTEMS Wall SELF-ASHERING SBS BASE PLY:
E
Min.15132- None None SBS-SA-H (Optional)SBS-TA 565-TA -90.0
inch plywood Min,15/32- PG100 None SBSSA-H (Optional)SBS-TA SBS-TA -97.5
nch plywood
Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled SBS-5A-H (Optional)SBS-TA SBS-TA -97.5
inch plywood into place to create continuous bond.
W-219 Min.15/32- POLYHRITE 745 None SBSSA-H (Optional)SBS-TA 565TA -105.0
inch plywood Or WB3000
NEMO tiTC,11C Evaluation Report P9290.02.08-R25 for FL1654-R27
Certificate of Authorization#32455 7-EDITION(2070)fBC NON-HVHZ EVALUATION Revision 25:09/30/2020
V2018 NEM{S ETC,LLC Polyglass ModiRed Bitumen Roof System5,14541 233-1330 Appendix 1,Page 37 of 94