Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 2 JACARANDA
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type41442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Adjacent R=11.0 192.00 ft' 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 2 d.NIA R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1504.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1474.00 ft2 6. Conditioned Floor area above grade(ft2) 1474 b.Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 G.NIA R= ft2 7. Windows(141.3 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl,U=1.04 101.25 ft' a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15,00 c. U-Factor: NIA ft2 SHGC: 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 3.832 ft.Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-FactoC(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap:50 gallons 9. Floor Types (1473.5 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1473.50 f12 b. Conservation features b.NIA R= ft2 None a NIA R= ft2 16.Credits None Glass/Floor Area: 0.096 Total Proposed Modified Loads: 44.66 PASS Total Baseline Loads: 45.56 I hereby certify that the plans and specifications covered by Review of the plans and 09-11JE$T,g this calculation are in compliance with the Florida Energy specifications covered by this r�. p Code. calculation indicates compliance �i, ;s s',�` *6. with the Florida Energy Code, PREPARED BY: Before construction is completed DATE: - - this building will be inspected for compliance with Section 553.908 „ I hereby certify that this building,as designed_,is in compliance Florida Statutes. with the Florida Energy Code. _ - ,p '0 WF OWNER G BUILDING OFFICIAL: DATE: -" - , DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/13/2021 8:02 AM EnergyGauge@ USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories; 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlalSook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfillD Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ____ 0 1 0 3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft' ___ 0 1 0 4&ab-On-Grade Edge Insulatio KITCHEN i ft 0 192 ft' ____ 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' ____ 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ____ 0 1 0 7 Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ____ 0 1 0 1/13/2021 8:02 AM EnergyGauge®USA 7.0,00-FlaRes202O FBC 7th Edition(2020) Compflant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---_ 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18.4 / ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREATIDINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall(Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below W. Ft In Ft in Area -lue 0 1 NE=>SW Exterior Concrete Block-Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=-NE Exterior Concrete Block-Int InsLd35DR00M 4.1 28 0 8 0 224.0 ft2 O 0 0.4 0 3 NW=>SE Exterior Concrete Block-Int InsuBEDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 6 NE=>SW Exterior Concrete Block-Int InsEXEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block-Int Ins fEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block-Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0A 0 9 SW=>NE Exterior Concrete Block-Int Ins@EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block-Int InsULAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block-Int InsLGREATIDINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block-Int InstORE=ATIDINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/13/2021 8:02 AM EnergyGauge@ USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space R Pi In A- Absor Grade �15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 a 20.6 ftZ WINDOWS Orientation shown is the entered orientation => chancied to Worst Case. / Wall Overhang 1/ # Ornt ID Frame Panes NPRC U-Factor SHGC Imp Area Depth Separation lnt Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.04 0.29 N 32.9 W 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 f12 1 ft 0 in 1 ft 5 in None None 3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5 in None None 4 NE=>SW 13 Metal Low-E Single Yes 1.04 0.29 N 37.5 112 1 ft 0 in 1 ft 5 in None None 5 NW=>SE 14 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in Drapeslblinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315ft2 315W 24ft Eft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.48 141.7 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UnIV Split Singl SEER: 15 34.8 kBtulhr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS / ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: CoolingJan Feb Mar Apr Ma Jun Jul rj Au Se Oct Nov Dec Heatin Jan Feb Mar Apr Ma l Jun Jui AuSeP OctX Nov lX]Oec Ventin Jan Feb Mar A r Ma [ Jun Jul Aug Se Oct XX]]Nov [ ))Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WO) PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 Ibs/sq.ft. ftz ft 0.3 WIC Detault(8lbs/sq.ft. ft' ft 0.3 M.BATH Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 lbs/sq.ft, ft' ft 0.3 BATH ❑efault(8lbs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY Default(8 Ibs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s .ft. ftZ ft 0.3 GREAVDINING 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: U Owner: Jurisdiction: W Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceilinglsoffit shall be aligned with The insulation in any dropped ceilingisoffiit Ceilinglattic the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between windowldoorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall e2aprid behind p0pjag_=d wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shalE be in accordance wiih the provisions of[CC-400. 1/13/2021 8:02 AM EnergyGauge@ USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index,the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 2 d.NIA R= ft2 5. Is this a worst case? 11.Ceiling Type and insulation level Insulation Area Yes a.Under Attic(Vented) R=30.0 1474.00 ftZ 6. Conditioned floor area(ft2) 1474 b.Knee Wall(Vented) R=19.0 30.00 ft2 2 7. Windows`" Description Area o.NIA 12.Ducts,location&insulation level R- R ft2 a. U-Factor: Sgl,U=1.04 101.25 ft2a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems k8tulhr Efficiency c. U-Factor: NIA ft2 a.Central Unit 34.8 SEERA5.00 SHGC: d. U-Factor: NIA ft2 14.Heating systems kStulhr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15. Hot water systems Cap:50 gallons a. U-Factor(AVG): NIA ft2 a.Electric EF:0.97 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1473,50 ft2 Credits(Performance method) None b. NIA R= ft2 c.NIA R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building t'TAE s�A� Construction through the above energy saving features which will be installed (or exceeded) ,y0 = C in this home before final inspection. Otherwise, a new EPL Display Card will be completed � ',� ��' ?aa`Or based on installed Code compliant features 1rr„> �; r O Builder Signature: �.� . �� \ 4 Date: � - - Address of New Home: C7`C-Cl City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 ® Project Summary Job: Wrightsoft Date: Jan 13,2021 Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Ptnm:772-466-6799 Fax 772466-6796 Ernail:QUICKCALCS al(A0L.COM Project Information For: WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 OF Inside clb 70 °F Inside db 75 OF Design TD 28 °F Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18852 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humtidification 0 Btuh Blower r;) 0 Btuh Piping 0 Btuh Equipment load 24506 Stuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ft�) 1474 147'4 Equipment latent load 5277 Btuh %fume(ft) 12227 12227 Airchan es/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 30370 Btuh Equiv.AVF(Cfm) 92 47 Req.total capaaty at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 Cond 25HBC536KO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @47°F Latentcooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 dm Air flow factor 0.047 dmlBtuh Airflowfactor 0.044 dmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=33°F Backup: Input=7 kW, Output=23009 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual 3 8th Ed. wri ht Ir 2021-Jar0308:11:06 .emu• WR Rigit-Sute®Urrversa1201919.021 RSU08101 Page 1 owrerLs\WdghtoftFIVACOYNNE-TVIC STERLING.rLr CaIc=MJ8 FrortDoorMoes:N - -w6ghtsoft• Right-J®Worksheet Entire House Date: Jan 13,2021 QUICK CALCS, INC. 317 ST.LUVE LN.,Fr.PIERCE,FL 34946 Phone:772-466-6799 Fax.772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E1posedwall 1802 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heatl000l 4 Room dimensions 1A x 329.0 ft 5 Room area 1473.5 fF 329.0 ft' Ty Construc0on U-value Or HTM Area (fF) Load number (Btuhlft�°F) (Btuh/P) or perimeter (ft) Load Area (fF) (ft) (B h) Heat Cool Gross N/P!S Heat Cool Gross NOS Heat Cool fi VE 13A4ors 0,143 ne 4.00 2.55 479 442 1768 1124 80 80 320 204 1A-c1om 1270 ne 35.56 70.43 38 0 1344 2662 0 0 0 0 13A-4ocs 0.143 se 4.00 2.65 128 83 331 210 0 0 0 0 1A-c1om 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11D0 0.390 se 10,92 11.31 22 22 236 244 0 0 0 0 w 13A-4o s 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 i3A-4ocs 0.143 sH 4.00 2.56 360 353 1414 899 224 224 897 570 T—G 1Aclom 1.270 sv 35.56 42.91 7 5 247 298 0 0 0 0 i 3A-4ocs 0.143 nw 4.00 2,55 290 217 867 551 112 79 318 202 1A-c1om 1270 nw 35.56 4524 33 0 1162 1478 33 0 1162 1478 4P5-2om 0.770 nw 21M 27.54 41 0 880 1124 0 0 0 0 P 12C-Osw 0.091 2.55 128 192 192 489 246 0 0 0 0 C 16A30md 0.032 0.90 2.32 1474 1474 1320 3419 329 329 295 763 F 22A-tol 0,989 27.69 0.00 1474 180 4989 0 329 52 1440 0 6 c)AED ex_ursion 784 680 Envelopelosslgain 16030 13954 4432 3897 12 a) Infil7ation 2822 T73 909 249 b) Room ventllation 0 0 0 0 13 Intemalgahs: Occupants@ 230 5 1150 2 460 Applianoeslother 2000 0 Subtotal(lines6to 13) 18852 178-a 5341 46M Lesse lemal load 0 cil 0 0 Lem transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18852 17877 5341 4606 15 Dudloads 130% 48% 5654 8536 30% 48%1 16021 2199 Total room load 24506 26413 6943 6805 Afrrequired(dm) 1160 1160 329 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � f�F wrlgf7t�a1"i' r "•14 A ^^ RigFk-Sate®Uriversal201919-021 RSU08101 Page 1 ...owneriAWdgi�t tHVAC1WVNNE-THESTERLING.rrp Calc=W8 FrortDoorfaces;N 2021-Jarr1308:11:06 - wrightsoW Right-J®Worksheet Jcb: Entire House Date: ,fan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN,,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC M BATH 2 E)posedmll 0 ft 8.0 ft 3 Room height 8.0 ft heatl0001 8.0 ft heaV000f 4 Room dimensions 7.0 x 9.0 R 7.0 x 8.0 ft 5 Room area 63.0 fF 56,0 fF Ty Construction iJ-value Or HTM Area W) Load number (Bb.Ih/F--°F) (Bhlh4F) or perimeter �r (ft) (Bbih) orperimebr (ft) (B1yh) Heat Cool Gross NIPIS Heat Cool Gross NIP1S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1270 ne 35.66 70.43 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 se 35,56 34.77 0 0 0 0 0 0 0 0 1 1 D 11 DO 0,390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 G 1Aclom 1270 sw 35.56 42.91 0 0 0 0 7 6i 247 298 Vj! 13A-0as 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 ��GG 1A-clan 1270 nw 35.56 46,24 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-OVN 0.091 2,55 1.28 0 0 0 0 0 0 0 0 C 16A-30md 0.032 0.90 2.32 63 63 56 146 56 56 50 130 F 22A-tpl 0.989 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AEDewxarsion -2 226 Envelope loselgain 56 145 747 798 12 a) I4"Eon 0 0 140 38 b) RoomvenTabon O 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancesrother 0 0 Subtotal(lines 6 to 13) 56 145 887 836 Less ex0emalload 0 0 0 0 Lessfransler 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Ductloads 30% 48% 17 69 30% 48% 266 3% Total room load 73 214 1w 1235 AJr required(dm) 3 9 55 54 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wtiv - 2021-Jan-13 08:11:06 Aft Rgtt-Sute®Uriversal 201919.0 21 RSU08101 page 2 ocmerrslWrighNoftHVAQWYNNE-THESTERLING.mp Calc=MJS Frort Door faces:N - wrightsoft- Right-J®Worksheet Job: Entire House Date. Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phore:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 Exposedvall 8.0 t 6.0 ft 3 Room height 8.0 It heaV000l 8.0 11 heaVcool 4 Room d1mensions 1.0 x 192.0 8 9.0 x 5.0 ft 5 Room area 192.0 ff 45.0 ft2 Ty Construction U-value Cr HTM Area Wad s (fly Load number (BWhd-'F) (BWhM2) or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross NIP15 Heat Cool Grass NIPS Heat Cool & �! 13A-4ocs 0.143 ne 4.00 2,65 0 0 0 0 40 40 160 102 6 VE-G 1A•clom 1270 ne 35.56 70A3 0 0 0 0 0 0 0 0 13A-4om 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 se 35-% 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13AAocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A-4ots 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 G 1A-Glom 1270 sw 36.66 42.91 0 0 0 0 0 0 0 0 13A4os 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-Glom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4A5.2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-09N 0.091 2,55 128 64 64 163 82 0 0 0 0 C 16A-30md 0.032 0.90 2.32 192 192 172 445 45 45 40 104 F 22A-tnl 0.989 27.69 0.00 192 8 222 0 45 5 138 0 6 c)AED excursion -27 .2 Envelope loss/gain 557 501 339 204 12 a) rnfiltration 0 0 87 24 b) Room+rentilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Appiianoesrother 2000 0 Subtottal(lines61a13) 557 2501 426 228 Less eArnal load 0 0 0 0 Lessbansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 557 2501 426 228 15 Ducdloads 30% 48%1 167 1194 30% 48% 128 109 Total room load 724 3695 554 336 Air required(cfm) 134 162 28 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wNghtsol't^ 2021-Jan-13 08:11:06 Right•Sutc�Uriver5ar201919A21 RSU08101 Page3 oamerlslWrightsoftWAC1WYNNE-THESTERLING.rp Cale=MJ8 Front Door faces:N -�-wrightsoft- Right-J®Worksheet Job: Entire House pate: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN„FT.PIERCE,FL 34946 Phorn:772-466-6799 Fax:772A66-6796 Email:QUICKCALCS@AOL,COM 1 Room name BEDROOM2 ENTRY 2 Exposed wall 322 ft 16.0 It 3 Room height 8.0 fl hwVeool 8.0 t heatl000l 4 Room dimensions 1.0 x 203.5 ft 1.0 x 55.0 It 5 Room area 203.5 fig 55.0 f6 Ty Constucton U-vatue Or HTM Area (ft') Load Area (ft-) Load number (BtuWF) (BtuhtF) or perimeter (ft) (Bfuh) or perimeter (ft) (Bfuh) Heat Cool Gross NA'!S Heat Cool Gross NIP/5 Heat Cool 6 4q! 13A-4- 0.143 ne 4.00 2,55 128 128 513 326 0 0 0 0 -� G 1A-c1om 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 VL 13A-4ocs 0.143 se 4.00 2.55 80 56 225 143 48 26 106 67 1A-clom 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0,390 se 10.92 11.31 0 0 0 0 22 22 236 244 W 13A-4ocs 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 13A-4ors 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 IA-clom 1270 sw $5,56 42.91 0 0 0 0 0 0 0 0 ILI13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 05-2am 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 72 72 183 92 C 16A-30md 0.032 0.90 2.32 204 204 182 472 55 55 49 128 F 22A-tpl 0.989 27.69 0.00 204 32 891 0 55 16 443 0 6 c)AED excursion -24 -6 Envelope IoWgain 2859 1873 1049 545 12 a) Infiltration 564 154 122 34 b) Room venfttion 0 0 0 0 13 Intemalgains: O=Wnts@ 230 1 230 0 0 ApplianoWother 0 0 Subtotal(lines 6 to 13) 13422 2257 1172 579 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 3422 2257 1172 579 751 Dud loads 30% 48% 1026 1078 30% 48% 351 276 Total room bad 4449 3335 1523 855 A1rrequired(crm) 211 146 721 38 Calculadons approved bvACCAto meet all requirements of Manual J 8th Ed. fI'F-�ry��yhtsdfC" •"• 2021-Jarr1308:11:06 Aft fZgiYScile®UYIVerSa1201919.021 RSW8101 Page9 oamertslWdgMsotHVAQWYNNE-THESTERLING.rLp Calc=MJ8 FrortDoorfaces:N + wrightil Right-J®Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. eY 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Ptnre:772-466-6799 Fa)c 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREATMINING 2 Exaosedwall 13.0 8 46.0 ft 3 Room height &0 ft heatkool 8.9 ft head000l 4 Room dimensions 7.0 x 6.0 It 1.0 x 488.0 It 5 Room area 42.0 fP 488.0 ft Ty Construction U-value Or HTM Area Load Area (flz) Load number (Btuhr--'F) (Btuh/P) or perimeter (1t) (Btuh) or perimeter (fl) ($huh) Heat Cool Gross N!P/S Heat Cool Gross N/PIS Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 231 194 775 493 "A-Glom 1270 ne 36.56 70.43 0 0 0 0 38 0 1344 2662 13A-4as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 3A-4' 0.143 sw 4.00 2.55 48 48 192 122 0 0 0 0 1 G 1Aa1om 1270 sry 35.56 42.91 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.56 0 0 0 0 178 137 549 349 G 1A-clom 1270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2om 0.770 nw 21.56 27.54 0 0 0 0 41 0 880 1124 P 12C-Ow 0.091 2.55 128 56 56 143 72 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 42 42 38 97 488 488 437 1132 F 22A-tpl 0.989 2T69 0.00 42 13 360 0 488 46 1274 0 6 c)AED emersion -3 S6 Envelope loWgain 733 288 5259 5704 12 a) InfilhIon 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: oocupants@ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines6to13) 837 $17 6154 6409 Less ekemalload 0 0 0 0 Lesstranster 0 0 0 0 RedistribWon 0 0 0 0 14 Subtotal 837 317 6154 6409 15 Dud loads 30% 480/ 251 151 30% 48% 1846 3060 Total room load 1089 468 8000 9469 Air required(cfm) I 1 1 52 21 1 3791 418 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -p}+F wrtgFr,tsolt 2021-JarA308:11:06 Rig F4S6LQUriversal 20l9 i9.021 RSUD8101 Page 5 ...oarnertslWdgtrsoftHVAMWYNNE-THESTERLING.rLp Calc=MJB FroriDoorfaces:N Duct System Summary Job: wrightsoft y rY Date: Jan 13,2021 Entire House By. QUICK CALCS, INC. 317 ST LUCIE LN,Fr..PIERCE,FL 34946 PhDr e:772.466-6799 Fax 772-466-6796 Email:QUiCKCALCS@AOL.COM Project • • For: WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.25010.250 in H2O 0.25010.250 in H2O Lowestfridon rate 0.284 in/100ft 0.284 in1100ft Actual airflow 1160 cfm 1160 cfm Total effective length(TEL) 176 ft SupplyDetail Table Ali Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (dim) (dm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH h 554 26 15 0.376 4.0 Ox 0 VIFx 18.1 115.0 st1 BEDRooM2 h 4449 211 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 ENTRY h 1523 72 38 0.510 5.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 189 208 0.318 7.0 Ox 0 VIFx 22.4 135.0 st2 GREATIDINING-B c 4735 189 208 0.307 7.0 Ox 0 MFx 28.1 135.0 st2 KITCHEN C 3695 34 162 0.375 7.0 Ox 0 MFx 18.3 115.0 st1 LAUNDRY h 1089 52 21 0.366 6.0 Ox0 MFx 21.6 115.0 stl M.BATH h 1153 55 54 0.366 4.0 Ox 0 VI Fx 21.6 115.0 st1 MASTERBEDROOM-A h 3471 164 149 0.297 6.0 Ox0 MFx 33.1 135.0 st2 MASTER BEDROOM-3 h 3471 164 149 0.284 6.0 OxO MFx 41.1 135.0 st2 WIG C 214 3 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfrrl) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 711 724 0.284 922 12.0 0 x 0 VinIFIX st1 st1 PeakAVF 1088 1122 0.284 1050 14.0 0 x 0 VinIFIX 1 wrightso t® 2021-Jen-13 08:11:06 RigR-Sdts6Uriversa1201919.021 RSU08101 Page 1 ..,ownerfslWrighlsoftHVAC1WYNNE•THESTERLING.np Calc=MJ8 Front Door face&N Return Branch Detail Table Grille Htg Cig TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfi l) ($) FIR (fpm) (in) (in) Opening(in) Mat Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx - -wrightsoft® 2021-Jarr1308:11:06 RgFt-SuI�Q]Uriversa12D1919.021 RSU081Q1.uus-ro..aaw Page oarner*Mrigitot VACIWYNNE-THE5TERLING.np Calc=MJ8 Front Door faces:N